Specifications:

  • Model: SPS 900 NODE
  • Power: 900 VA / 480 W
  • Topology: Off-Line
  • Input Voltage: 50 / 60 Hz auto detectable
  • Input Connections: 3 (Phase + Neutral and Ground) via a plug-in hose
  • Efficiency: > 98%
  • Battery Runtime: 8 hours at 90% load
  • Overload Protection: Continuous beeping
  • Dimensions: 153 x 438 x 86 mm
  • Weight: 5.0 kg
  • Protection Rating: IP20

Product Usage Instructions

1. Utilizing the Manual:
Visit www.salicru.com for further information. The terms used in the document are interchangeable.

2. Quality Assurance and Regulations:

2.1. Regulations:
The product complies with relevant regulations and environmental standards.

2.2. Environmental Concerns:
The packaging is environmentally friendly.

3. Equipment Overview:
The SPS 900 NODE is a Standby Power Supply with a power rating of 900 VA.

4. Views and Labels:
Refer to Fig. 1 for front and back views of the equipment. Use the power switch to turn the SAI on or off. The EPO port allows for emergency shutdown.

5. Installation and Considerations:

5.1. Placement:
Ensure proper placement of the equipment.

5.2. Considerations:
Connect all devices to the output bases of the equipment and take precautions against direct contact.

6. Operating Instructions:

6.1. Procedure:

  1. Connect the PC, monitor, and sensitive equipment to the output bases of the unit.
  2. Press the ON/OFF button to power on the unit.

Frequently Asked Questions

Q: What should I do if the SAI does not start?
Possible Cause: The circuit breaker has tripped due to overload or a short circuit.

INTRODUCTION

THANK-YOU LETTER.
We would like to thank you for purchasing this product. Read this instruction manual carefully to familiarize yourself with its content, since the more you know and understand the equipment the greater your satisfaction, level of safety, and optimization of its functionalities will be. Please do not hesitate to contact us for any further information or any questions you may have.

Yours sincerely, SALICRU

  • The unit described in this manual can cause serious physical injury if handled incorrectly. Therefore, the unit must only be installed, serviced, and/or repaired by our staff or by qualified personnel.
  • Although every effort has been made to guarantee that the information in this user manual is complete and accurate, we are not responsible for any errors or omissions that may be present. The images included in this document are for illustrative purposes and may not represent exactly the parts of the equipment shown, therefore they are not contractual. However, any differences will be reduced or resolved through the correct labeling on the unit.
  • In line with our policy of continuous development, we reserve the right to modify the specifications, operating principles, or actions described in this document without prior notice.
  • The reproduction, copying, transfer to third parties, modification, or translation in full or in part of this manual or document, in any form or by any means, without prior written consent from our company, is prohibited, with us reserving the full and exclusive right of ownership to it.

SAFETY INFORMATION.

USING THIS MANUAL.
The documentation of any standard unit is available to the customer
on our website for download (www.salicru.com).

  • For units with a “permanent connection”, connection via terminals, including the EK266*08 “Safety instructions”.

Please read these instructions carefully before carrying out any action on the unit in terms of installation or start-up, change of location, configuration, or handling of any type. The purpose of the user manual is to provide information relating to safety, as well as explanations about the unit’s installation and operating procedures. Read them carefully and follow the steps in the corresponding order. Compliance with the “Safety instructions” is mandatory; therefore, the user will be legally responsible for observing and applying them at all times. All units are supplied with the corresponding labels to guarantee the correct identification of each part. In addition, the user can refer to the user manual at any time during installation or start-up, which provides clear, well-organized, and easy-to-understand information.
Finally, once the equipment is installed and operating, it is recommended to save the documentation downloaded from the website in a safe and easy-to- access place, for any future queries or doubts that may arise. The following terms are used interchangeably in the document to refer to:

  • “SPS NODE, SPS, NODE, equipment, unit or UPS”.
    •  Uninterruptible power supply. Depending on the context of the sentence, they may refer interchangeably to the UPS itself or the UPS and the batteries, regardless of whether it is assembled in the same metal enclosure -box- or not.
  • “Batteries or capacitor banks”.- A group or set of elements that stores the flow of electrons by electrochemical means.
  • “T.S.S.”.- Technical Service and Support.
  • “Customer, installer, operator, or user”.- They are used interchangeably and, by extension, to refer to the installer and/or the operator who will carry out the corresponding actions, whereby the responsibility for carrying out the respective actions may be held by the same person when they act on behalf or in the representation of the installer or operator.

Conventions and symbols.
Some symbols may be used and may appear on the unit, batteries, and/or in the user manual. For more information, see section 1.1.1 of the document EK266*08relating to the “Safety Instructions”.

QUALITY ASSURANCE AND STANDARDS.

MANAGEMENT STATEMENT.
We aim to satisfy our customers. Management has established a Quality and Environmental Policy for such purposes. As a result, a Quality and Environmental Management System will be implemented, which will ensure that we are compliant with the requirements of the ISO 9001 and ISO 14001 standards and that we meet all customer and stakeholder requirements. The company management is also committed to the development and improvement of the Quality and Environmental management system, through:

  • Communication to the entire company of the importance of satisfying both the client’s requirements as well as legal and regulatory requirements.
  • Dissemination of the Quality and Environmental Policy and setting of the Quality and Environment targets.
  • Management reviews.
  • Provision of the necessary resources.

STANDARDS.

The SPS.NODE product is designed, manufactured, and marketed by the EN ISO 9001 Quality Assurance standard. The mark indicates conformity with the EEC Directives through application of the following standards:

  • * 2014/35/EU. – Low voltage directive.
    • 2014/30/EU. – Electromagnetic compatibility (EMC).
    • 2011/65/EU. – Restriction of hazardous substances in electrical and electronic equipment (RoHS).
  • According to the specifications of harmonized standards. Reference standards:
    • EN-IEC 62040-1. Uninterruptible Power Supplies -UPS-.
  • Part 1: General and safety requirements for UPS used in user access areas.
    •  EN-IEC 62040-2. Uninterruptible Power Supplies -UPS-.
  • Part 2: Electromagnetic compatibility (EMC) requirements.

The manufacturer shall not be held responsible for any damage caused by the user altering or tampering with the unit in any way.

WARNING!: The SPS.NODE is a C1 category UPS. This unit is not suitable for use in basic life support (BLS) applications, whereby a fault in the unit could prevent the life support machine from working or could significantly affect its safety or effectiveness. Likewise, it is not recommended for medical applications, commercial transport, nuclear installations, or other applications or loads, whereby a fault in the product could lead to personal injury or material damage.

The EC declaration of conformity for the product is available for the customer and can be requested from our head office.

UKCA PRODUCT MARK AND UK

AUTHORIZED REPRESENTATIVE.
UK CA product marking indicates that this UPS has been evaluated by Salicru and is deemed to comply with safety, health, and environmental protection requirements. The UK CA Declaration of Conformity is available upon request. For copies of the UKCA Declaration of Conformity, please contact Salicru or check our website: www.salicru.com. UK Authorised Representative. Indele Limited. 7 Bell Yard. WC2A 2JR. London.

ENVIRONMENT

This product has been designed respecting the Environment and
manufactured in our certified facilities according to ISO 14001
standard.

Recycling the unit at the end of its useful life:
Our company commits to using the services of approved companies that comply with the regulations to process the recovered product at the end of its useful life (please contact your distributor).

Packaging : To recycle the packaging, follow the applicable legal regulations, depending on the particular standards of the country where the unit is installed.

Batteries:
The batteries represent a serious health and environmental risk. They must be disposed of by the applicable laws.

PRESENTATION

VIEWS OF THE EQUIPMENT.

LEGENDS CORRESPONDING TO THE VIEWS.

  • Input multi-function ON/OFF switch: Press the power switch for 2 seconds to turn the UPS on or off.
  • Status mode indicator: the switch will light up in different colors depending on the status of the equipment. (see Tab. 2).
  • Mute setting: The audible alarm can be turned OFF or ON by pressing the power button twice repeatedly, either in normal operation or on battery power. The default setting is for Alarm On.
  • Schuko sockets with autonomy and overvoltage protection: They guarantee power supply to connected equipment during backup time in case of power failure.
  • IEC input socket: Connect the UPS to the mains via the cable supplied.
  • USB-HID port: This port allows connection and communication from the USB port of the computer to the UPS unit.
  • EPO port (option): Enables emergency shutdown of the UPS from a remote location. With the EPO terminal open, the UPS will shut down and the output will disconnect immediately (see section 5.3.2.).
  • Resettable incoming circuit breaker protection: overload protection.

NOMENCLATURE

DESCRIPTION.
The SPS NODE series UPS is an Off-Line UPS designed to be fully adaptable to single-user environments. With the attractive appearance of a rack unit, it has eight output sockets, capable of supplying a more or less extensive backup time depending on the level of load connected to the output. All outlets are equipped with surge protection. The main function of the UPS is to supply the equipment connected to the output sockets for a limited period in the event of a mains failure, using the internal battery it incorporates.  Off-line UPSs do the latter, covering mains failures by supplying a similar voltage for some time. Under normal conditions, the UPS output is the same as the AC mains input. A real-time detection circuit detects main outages, switching to battery quickly, allowing the system to keep loads powered with a modified sine wave. Communication and control of the equipment are available through a USB-HID port and monitoring and management software.

Structural block diagram

Main benefits.

  • Off-Line technology.
  • 900 VA in 2U rack format.
  • Compatibility with APFC type loads.
  • The vast majority of power supplies for electronic equipment are switched-mode power supplies (SMPS) and, increasingly, incorporate an active power factor correction (APFC) to minimize the distortion caused to the power line. SPS NODE UPSs are compatible with all equipment incorporating these features.
  • The pseudo-sine waveform of the output voltage.
  • 6 sockets on the front panel + 2 additional sockets on the rear panel.
  • USB interface with HID protocol.
  • PowerMaster+ software for Windows, Linux, or Mac.
  • Auto-detection of input frequency 50 / 60 Hz.
  • Cold start capability, ColdStart function.
  • Automatic restart after mains failure and end of autonomy.
  • Overload protection using accessible thermal protection.
  • Battery protection by internal fuse.
  • Fanless technology.

INSTALLATION AND OPERATION.

  • Read and observe the Safety Information described in Chapter 2 of this document. Failure to observe any of the instructions described in this document may result in serious or very serious accidents to persons in direct contact or the immediate vicinity, as well as damage to the equipment and/or the loads connected to it.
  • During discharge, the equipment operates in IT (isolated earth) neutral mode. This means that the neutral is not directly connected to the earth, providing an additional layer of safety and stability in critical situations. To ensure optimal and safe operation, follow the guidelines in the user manual and contact your distributor if you have any questions.

RECEPTION OF THE EQUIPMENT.

Reception, unpacking, and contents.

Reception.

  • Check the data on the label affixed to the packaging correspond to those specified in the order. Remove the unit from the packaging and check the above data against the data on the nameplate on the SPS.NODE. If there are any discrepancies, report the non-conformity, quoting the references on the delivery note.
  • Check that it has not suffered any damage during transport.

Unpacking.

  • The packaging consists of a cardboard envelope, printed in four-color process, which illustrates all sides of the packaging, and two molded pieces of expanded polystyrene (EPS) to protect the SPS.NODE.

Content.

List of contents.

Item Description Quantity
1 SPS NODE 1
2 AC mains connection cable. 1
3 USB cable. 1
4 Rack mounting brackets, screws, screw covers, and rubber feet 2 x 8 x 14 x

4
5| Quick guide| 1
6| Guaranty leaflet| 1

  • Once the reception has been completed, it is advisable to put the equipment back in its original packaging as a preventive measure, if you are not going to install it in the next few days.
  • About packaging, when you need to dispose of it, you must do so by the laws in force. We advise you to keep it for at least 1 year.

LOCATION AND CONSIDERATIONS.

Location.

  • Install the unit in a location taking into consideration and respecting the indications of the Safety Instructions of document EK266*08.
  • The UPS can be placed in a rack cabinet or fixed under a table using the brackets provided for this purpose, as shown in the following figure:

Under-table installation.

Considerations

Battery charging.

  • Although the equipment can operate without any inconvenience without charging the battery for the indicated time, the risk of a prolonged outage during the first hours of operation and the backup time or autonomy available by the UPS, which may be uncertain, must be taken into account.

Power connected to the SPS.NODE.

  • Check that the loads connected to the sockets do not exceed the power of the unit, see section 7 of this document. If the rated capacities are exceeded, an overload condition will occur.
  • For optimum performance keep the load connected to the SPS below 80% of rated capacity.

CONNECTION AND START-UP

PROCEDURE.

  • All equipment connections, including control connections, shall be made with all switches at rest and no mains present (UPS power line disconnect switch “Off”).
  • It must never be forgotten that a UPS is a generator of electrical energy, so the user must take the necessary precautions against direct or indirect contact when it is part of the installation.

Procedure to follow.

Observe the following order of operation and instructions:

  • Connect the PC, display, and sensitive equipment to the output sockets
    •  Of the equipment. Do not connect a laser printer, paper shredder, or other power-hungry electrical devices or high current spikes to the output sockets. The power demand of any of these devices will overload the SPS and possibly damage the unit.
  • Take the supplied power cord (see “Tab. 1. List of contents”) and connect the plug at the end to a properly connected AC outlet (socket outlet) with a protective earth connection. The power supply socket of the SPS.NODE shall be protected by a fuse or a circuit breaker. This line must not supply machines with high electrical demands (e.g. air conditioning, refrigerator, etc.). Avoid the use of extension cables, as the SPS itself could be considered a PDU.
  • Press the ON/OFF button
    •  to start the unit. The green power indicator LED will light up It is possible to start up without the mains being present (Cold start function) by pressing the ON/OFFbutton
    •  However, this is not recommended, as if the mains failure is prolonged beyond the available autonomy, it will also be necessary to carry out the forced shutdown.
  • In the event of mains failure and reaching the end of battery autonomy, the equipment will automatically block, leaving the loads without a power supply. In the same way, when the mains voltage is restored, the device will start automatically.
  • In case of storing or keeping the UPS for a long period, protect it against dust, impacts, etc., and keep it with the battery fully charged. Recharge according to the period established in Table 2 of the document EK266*08 corresponding to the Safety Instructions, in correlation to the ambient temperature to which the SPS is.NODE is subjected. In this way, a longer battery life can be guaranteed.

Optical and acoustic indications

Power ON/ OFF button Acoustic alarm Conditions of the SPS NODE
      ‘fixed’ Led Not Active Normal operation of the SPS

‘flashing’ Led

| Slow modulated beep (every 30 sec.)| Mains failure – UPS supplying power to the bases ‚
Fast modulated beep (every 2 sec.)| Mains Failure – The UPS is supplying power from the battery. Rapid beeps indicate that the battery will be depleted shortly.

‘flashing’ Led

|

Fast modulated beep (every 0.5 sec.)

| Moderate overload: occurs when the connected equipment exceeds the rated capacity of the SPS.

Disconnect at least one piece of equipment to return to a normal operating state.

‘fixed’ Led

|

Constant beeping

| Excessive overload: This occurs when the connected equipment exceeds the rated capacity of the SPS.

Disconnect several devices at the same time and switch off the SPS NODE by pressing the ON/OFF switch.

General fault: This occurs when there is a short circuit in the connected load or due to internal faults in the SPS itself. Switch off the SPS by pressing the ON/ OFF switch for more than 2 seconds and press it again to restart it, if the problem persists contact the SST.

EPO terminals (Emergency Power Output)

  • The SPS NODE has two terminals for the installation of an external pushbutton for Emergency Power Off -EPO-.
  • By default, the equipment is shipped from the factory with the EPO circuit type closed -NC-. In other words, the UPS will cut off the output power supply, and emergency shutdown, when the circuit is opened:
    •  Rating the push button external to the equipment owned by the user and installed between the terminals of the connector (see Fig. 4-B).
    • The connection on the push button must be on the normally closed contact -NC-, so it will open the circuit when it is actuated.
  •  To recover the normal operating status of the UPS, it is necessary to insert the connector with the jumper in its receptacle or deactivate the EPO push button. The equipment will be operational

Connector for external EPO.

Communications connection

Connect the communication cable supplied with the equipment to the USB-HID connector of the UPS and the other end to the computer. With the Power Master software installed on the PC, the status of the UPS can be monitored remotely, as well as performing a shutdown/automatic restart, without necessarily being attended in person.

Software

  • Download free Power Master software.
  • Power Master is a UPS monitoring software, which provides a user-friendly monitoring and control interface. This software provides an auto shutdown for a multi-PC system in case of power failure. With this software, users can monitor and control any UPS on the same LAN computer network through the communication port, no matter how far apart they are from each other.
  • Installation procedure:
    • Go to the website: http://support.salicru.com
    • Choose the operating system you need and follow the instructions on the website to download the software.

MAINTENANCE, WARRANTY AND SERVICE.

GUIDE TO PROBLEMS AND SOLUTIONS.

  • If the UPS is not working properly, before calling the S.S.T. try to solve the problem using the information in the table below.

Guide to problems and solutions.

Problem Possible cause Solution

The sockets stop supplying power to the equipment. The circuit breaker button protrudes from the side of the unit.| The circuit breaker has tripped due to an overload or short circuit.| Turn off the UPS and unplug at least one of the connected loads. Reset the circuit breaker by pressing the red button and then start up the UPS.
The UPS does not comply with the expected back-up time.| The battery is not fully charged.| Recharge the battery by leaving the UPS plugged in.
The battery is slightly deteriorated.| Contact the Technical Service (T.S.S.)

UPS does not start

| The on/off switch is designed to prevent damage when turning it off and on quickly.| Switch off the UPS. Wait 10 seconds and then switch on the UPS.
The battery is damaged.| Contact the Technical Service (T.S.S.)
Mechanical problem with the ON/OFF switch.| Contact the Technical Service (T.S.S.)

MAINTENANCE.

  • This product does not require preventive maintenance.

CONDITIONS OF THE GUARANTEE.
Terms of guarantee.
On our website, you will find the warranty conditions for the product you have purchased and you can register it there. It is recommended to do this as soon as possible to include it in the database of our Technical Support Service (T.S.S.). Among other advantages, it will be much quicker to carry out any regulatory procedure for the intervention of the T.S.S. in the event of a hypothetical breakdown.

Exclusions.

Our company shall not be bound by the warranty if it finds that the defect in the product does not exist or was caused by misuse, neglect, improper installation and/or testing, unauthorized attempts at repair or modification, or any other cause beyond the intended use, or by accident, fire, lightning or other hazards. Nor does it in any way cover compensation for damage or injury.

TECHNICAL SERVICES NETWORK.

The coverage, both national and international, of the Service and Technical Support (S.T.S.) points can be found on our website.

ANNEXES

TECHNICAL CHARACTERISTICS.

Models SPS.900.NODE
Power 900 VA / 480 W
Technology Off-Line.

Input
Voltage| 220.. 240 V AC single-phase
Voltage range| 180.. 270 V AC
Frequency| 50 / 60 Hz autodetectable
Number of power cables| 3 (Phase + Neutral and Earth) using hose with a plug at the end
Output
Rated voltage| 230 V AC single-phase
Voltage accuracy| ±7 %
Frequency| 50/60 Hz ±1 Hz
Waveform| Pseudosenoidal
Typical transfer time| 14 ms max.
Compatibility APFC loads| Yes
Electronic protection| Power overload, short-circuit
Line mode overload| > (100 ±10 %), alarm only; > (130 ±10 %), immediate output voltage cut off
Overload in battery mode| > (110 ±10 %), output voltage cut-off after 10 s alarm

(120 ±10 %), output voltage cut-off immediate

Outlets| 8 (for powering critical loads -battery mode-)
Efficiency
Line mode| > 98 %
Battery mode| > 70 %
Battery
Nominal voltage element| 12 V DC (Sealed, maintenance-free lead-acid battery)
Number of elements / Capacity| 1 / 9 Ah
Typical recharge time| 8 hours at 90 % load
Illuminated and acoustic indication
Peripheral to the On-Off button| Using LEDs
Light indications| Normal operating mode, Mains failure, End of autonomy, Overload

Acoustic alarm

| Battery mode: beep every 30 sec. Low battery: beep every 0.5 sec. Overload: continuous beep General fault: continuous beep
Physical
Overall dimensions (Depth x Width x Height)| 153 x 438 x 86 mm.
Weight| 5,0 kg
Degree of protection| IP20
Total outlets| 8
Critical load output sockets + overvoltage protection| 8
Environmental
Working temperature| 0.. 40 ºC
Relative humidity| 0.. 90 % non-condensed
Interface, communication, and management
USB (HID)| Yes
Protector línea telefónica /ADSL| Yes
Software Power Master| Windows 8 / 7 / Vista / XP / 2000 / Server 2003, Linux
Self-charging of batteries.| Yes
Auto start after mains failure.| Yes

Avda. de la Serra 100 08460 Palautordera
BARCELONA
Tel. +34 93 848 24 00
sst@salicru.com
SALICRU.COM

Information about the technical support and service network (TSS), the sales network, and the warranty is available on our website: www.salicru.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals