condair DL Series In Duct Evaporative Humidifier And Cooler Instruction Manual

September 19, 2024
condair

CONDAIR DL SERIES
In-duct evaporative humidifier and cooler
Selection Guide

Condair DL Series

Two adiabatic humidification methods intelligently combined
The Condair DL hybrid humidifier is based exclusively on the advantages of the two humidification principles of atomization and evaporation. This results in the sustainable resolution of key problems which can emerge when these technologies are used individually. The humidification system is therefore the first choice in terms of hygiene, energy efficiency and cost-effectiveness.


The humidifying water is atomized by stainless steel atomizing nozzles at low pressure. The atomizing nozzles have an adjustable spray output and are optimally distributed over the entire cross-section of the device. A high evaporation efficiency and a uniform humidity distribution are achieved by this layout.
The evaporator unit made of premium ceramic is placed at the end of the humidification distance. It captures the humidifying water and ensures the best possible reevaporation.
The ceramic plates thus allow the most effective utilization of the high-grade humidifying water, while also preventing water accumulation in downstream components.

Why the DL Series?

| Efficient low-pressure systems
The low-pressure mode of operation translates to significant energy savings due to the lesser compression work.
---|---
| Aerosol-free air
Using the patented ceramic evaporator unit, the humidifying water is completely separated from the air current and effectively evaporated.
| Effective degermination
The HygienePlus® concept includes a series of measures for effective germ neutralization. The key element here is the patented silver ionization guaranteeing reliable hygiene and safety.
| Precise control
The unique combination of the spray circuit drive and continuous water quantity control allows precise control accuracy.

2.2 Configure product

Select which options you would like to include. The most common are:

| This inexpensive option is necessary for all DL projects. The clamping brackets hold the rubber sealing in place against the bottom of the drain pan so that it does not lift due to the air velocity. This prevents air bypass under the ceramics, which can lead to lower system efficiency.
---|---
The sterile filter with automatic self-monitoring is installed upstream of the booster pump, extending the life of the booster pump. Provides additional hygiene safety.
The leak detection system provides an additional safety sensor in the central unit. If the sensor detects the presence of water accumulating at the bottom of the central unit, it will shut down the unit and trigger a fault alarm.
| Water temperature value can be processed in the control unit to trigger a two-stage temperature flush. The flushing should prevent the hydraulic system from freezing due to the movement of the water.
Additional fittings and connection points to allow the system to be dried and flushed with  ompressed air. This can be used for summer shut-downs, periodic inspections, or cases
where additional flushing and disinfection is required.
Used to flush the supply pipe from the reverse osmosis to the DL. When flushing, the water in the supply pipe will thereby not flow through the DL but will be guided into the drain. Please consider space conditions.
The external water filter serves as a pre-filter and is installed at the water inlet prior to the central unit.
Germ neutralization can be carried out by H2O2 disinfection rather than silver ions.
A T-connector and check valves are added to the hydraulic system, allowing a disinfectant to be introduced. Not recommended for systems with load > 400 lb/hr due to pressure loss.

Distributors are not required for adiabatic humidification.

This product does not require a distributor configuration. Please proceed to the next step.

4.1 Choose controls

An air proving switch and high limit device are always required, whether supplied by Condair or others.
Please select any common options you would like for this zone. You may edit the quantity where applicable.
Accessories can be selected as desired.
Below is the list of materials for this zone. You can add another zone or go back to the project home page to view your bill of materials and generate documents.

Complete Parts and Humidifiers List

This section displays a summary of the full system selection. One DL consists of several components, all of which are indicated with the “DL_” prefix.

Questions? For help with any of your humidification projects, contact your local Condair representative.

USA 1021 6
Street, Racine, WI 53177
Canada 2740 Fenton Road, Ottawa, Ontario K1T 3T7
Tel 1.866.667.8321 Fax 613.822.7964
Email na.info@condair.com
Websitewww.condair.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

condair User Manuals

Related Manuals