SHOWVEN 20240624 Sparkular Case User Manual
- September 17, 2024
- Showven
Table of Contents
USER MANUAL
SPARKULAR® FALL
V2.2
2024/06/24
Showven Technologies Co., Ltd.
20240624 Sparkular Case
Thanks for choosing SPARKULAR® FALL, we wish it will sparks up your show.
Please read the following manual carefully before operating this product.
Safety Instructions
- Unauthorized repair are prohibited, it may cause serious incident.
- Keep SPARKULAR® FALL dry and do NOT use in rain or snow.
- Make sure lid of feeding hopper are well covered when use SPARKULAR® FALL.
- Accidentally burning of consumable can only use sands to extinguish.
- Consumable should keep away from moisture and stored in a dry sealed environment.
- Check whether there is consumable aggregate in the output nozzle both before and after each show, if any, please clean it up, or it will affect the firing effect, damage machine, even cause serious incident.
- The SPARKULAR® FALL power supply cable maximum allowed cascade of 6pcs (BT04) / 3pcs (BT05), exceed connecting may result in damage or even cause fire.
- For better heat dissipation, block the air intake and air outlet is prohibited.
- Cover the output nozzle of SPARKULAR® FALL is forbidden, inspect the machine before each show, making sure no objects or material will block the output nozzle.
- Never touch the nozzle of SPARKULAR® FALL, danger of getting burnt.
- Never touch the sparks which shooting out from the nozzle.
- Make sure no staff, audience and flammable materials stays under the SPARKULAR® FALL.
Safety Distance
- Keep audience and flammable material at a minimum distance of 3m from SPARKULAR® FALL.
- Make sure sparks shoot out from SPARKULAR® FALL can NOT touch any objects. And keep a clearance with minimum 2m from the setting maximum effect length.
- Human, animal or flammable materials are not allowed to close to the underside area where hanging SPARKULAR® FALL.
- In windy environment, increase the safety distance according to the wind direction and speed.
- The safety zone area shifts accordingly when machine installed in tilt position. Please increase the safety distance in the direction which machine tilt.
- Sparks and consumables from the machine can lead to serious eye injury. Always wear safety goggles when enter the safety zone.
Description
SPARKULAR® FALL is hanging special effects equipment for indoor/outdoor use to generate dazzling silver “waterfall” sparks effects. According to different usage scenarios, operator can self define various types of “spark curtain” effects vary from 2m to 7m by use of different types of HC8200.
Structure of SPARKULAR® FALL
- Safety Loop
- Clamp
- Feeding Hopper Lid
- Air Intake
- DMX IN
- DMX OUT
- Power Switch
- Fuse
- Power IN
- Power OUT
- LCD Screen
- Cooling Fan
Schematic diagram of the top fixing hole
Technical Specifications
- MODEL: BT04/BT05
- DIMENSION: 196×208×192mm
- WEIGHT: 6.0kg
- VOLTAGE: 220V(BT04)/110V(BT05), 50/60Hz
- WORK POWER: 500W
- EFFECT HEIGHT: 2-7m(according to HC8200 type)
- INTERFACE: 3-pin XLR, POWER IN/OUT
- CONTROL: DMX 2 channels, Wireless Remote
- ADAPTABLE TRUSS SIZE: 40-60mm
Operation Panel
1. LED display area: READY: Flash means machine is preparing, LED keeps
on means ready to work
DMX: Flash means DMX signal is connected, light OFF means there is no DMX
signal
FAULT: Light ON when error occurs
HEAT: Light ON when system is heating up
2. Control button area: MENU Press to switch through menu, press and
hold for 3s enter advanced menu
-: Parameters down
+: Parameters up
ENTER: Confirm and save parameters.
3. Bottom Indication Light Off: Preheating not activated or machine is
firing
Quick Flashing: Preheating
Long on : Preheated
Slow Flashing: Error warning
The indication light can be turned off in menu.
4. RFID area Composite Ti with RFID card, swiping cards used to identify
parameters and types of granules.
The RFID card is disposable, one card can only use one time.
Interface
1. Main Interface First line: Display DMX address is “1”
Second line: Display the present inner core temperature and the
temperature progress bar; displays remaining time is 7 minutes and 24 seconds.
2. Error information
Error information | Explanation |
---|---|
E0 System IC | Systematic error |
E2 Temp. Sensor | Temperature sensor is not connected or damage |
E3 P Temp. Over | Chassis over-temperature |
E4 Time Remain | Insufficient granules or remaining time, please swiping time |
card
E5 K Temp. Over| Heating chamber over-temperature
E6 Heat Fail| Heating failed
3. Setting Menu
Press “MENU” to enter the Setting interface, press the “MENU” button to enter
different options until you return to the main interface
Options | Range | Default | Explanation |
---|---|---|---|
Set DMX Address | 1-512 | 1 | Set the DMX address, machine become a wireless host |
and can send out DMX signal when its address is “1++”
Wireless Control| ON/OFF| OFF| Wireless function switch, you can match machine
with remote controller when at “ON” status
Manual Fountain| ON/OFF| OFF| Manual fountain switch, for testing purposes
only
Fountain Height| 1 / 6| 1| 1 is low level, 6 is high level
4. Advanced Menu
Press and hold “MENU” for 3s to enter the advanced setup interface, press MENU
key to enter different options, wait 3 seconds to return to the main
interface.
Options | Range | Default | Explanation |
---|---|---|---|
Set Temperature | 480-620 | 580 | Setup inner Core temperature |
Auto Heat | ON/OFF | OFF | Auto preheat function switch after turn on machine |
Density | 70-100 | 90 | Adjust the sparks density |
Mode Selection | Factory Mode User Mode | User Mode | Factory Mode is factory |
debugging mode, User Mode is using mode
DMX Channel Mode| 2 / 4 / 2+3 DMX Channel| 2 DMX Channel| Don’t change. 4 DMX
Channel and 2+3 DMX Channel are for special use.
Tip Over Error| ON/OFF| OFF| Tip over sensor ON/OFF
Default Parameter| | | Useless
Standby Switch| ON/OFF| OFF| When ON, the machine can firing only when heating
up was finished
Status LED| ON/OFF| ON| Bottom indicate light ON/OFF
5. DMX mode
When using the DMX controller, SPARKULAR® FALL occupy 2 DMX channel.
The First channel | Functions |
---|---|
0-15 | Firing OFF |
16-135 | Low Level Fountain ON |
136-255 | High Level Fountain ON |
The second channel | Functions |
60-80 | Clear Material |
20-40 | Emergency Stop |
0-10 | Pre-heat OFF (Disable in Auto-heat) |
240-255 | Pre-heat ON (Disable in Auto-heat) |
Operation Guide
1. Check output nozzle of SPARKULAR® FALL
Check carefully the output nozzle of each machine, make sure the output nozzle
is in good shape and there is no powder aggregate.
2. Fill SPARKULAR® FALL
a) Open powder bags and fill the feeding hopper. Hopper capacity of SPARKULAR®
FALL is 280g.
b) Choose correct consumable according to the hanging height and safety
distance.
c) Make sure the lid of hopper is locked tight after filling.
HC8200 | Fall length (Low Level) | Fall length (High Level) |
---|---|---|
MEDIUM | 2m | 3m |
LARGE | 3m | 4m |
LARGE-Ⅰ | 4m | 5m |
LARGE-Ⅱ | 5m | 7m |
3. Install SPARKULAR® FALL
a) Vertical hanging installation is preferred for SPARKULAR® FALL. If need to
installed SPARKULAR® FALL in angles, please turn the Tip over to OFF status
first, maximum firing angle is 45 ° and can only be angled to the front side
of the machine as below picture.
b) Make sure the machine is securely hanging on truss to avoid falling. An
extra safety rope is required for extra safety.
4. Connect Power / DMX cable
a) Connect a power cable to the POWER IN socket of SPARKULAR® FALL. Connect
the other end of power cable to the power source. Make sure power supply in
consistent with the rated voltage of the equipment, and the socket must well
grounded.
b) If connect machine in sequence, please connect a power link cable to the
POWER OUT of previous machine, connect the other end of the power link cable
to POWER IN of the next machine.
c) The SPARKULAR® FALL power supply cable maximum allowed cascade of 6pcs
(BT04) / 3pcs (BT05). Do not connect exceed units to a single electrical
circuit.
d) Power ON all SPARKULAR® FALL.
e) Assign DMX address for each unit of SPARKULAR® FALL. If use SHOWVEN host
controller or FXcommander to control the machine please allocate a unique DMX
address for each unit of machine.
If use remote controller to control SPARKULAR® FALL wirelessly, please set
machine to wireless ON status and match machine with remote controller. For
DMX cable control please execute below operations (f to h).
f) Connect a DMX cable to the DMX IN socket of first unit of SPARKULAR® FALL,
connect the male connector end of DMX cable to your DMX controller
(FXcommander, HOST CONTROLLER, light console etc).
g) Connect a DMX cable to the DMX OUT of previous machine, and the other end
of to the DMX IN of next machine. Connect all devices in series in this way.
h) Suggest to plug in a DMX terminator into the DMX OUT in last unit of
machine to improve signal reliability. Signal amplifier is required for long
distance (>200m) DMX signal transmission.
5. Activate SPARKULAR® FALL by swipe RFID card
a) Swipe an RFID card. Read the card as show below. SPARKULAR® FALL shows time
remain if read successfully.
b) SPARKULAR® FALL will report E4 when remaining time is less than 10 minutes.
c) Please note each RFID card come with 200g package HC8200 can increase
single machine 20min working time, the maximum recharge time for SPARKULAR®
FALL is 30min, when time remain reached 30min, it can’t recharge anymore RFID
card. 6. Programming and Firing
a) Programming SPARKULAR® FALL, set the firing height, firing sequences etc.
b) Heating up machine, it takes around 5min. it various according to the
voltage and environment temperature.
c) Make sure the prescribed safety zone is clear.
d) Suggest to clear material before firing.
e) Firing. In order to prevent overheat in the heating chamber and protect
machine, the maximum continuous firing time for SPARKULAR® FALL is 30s.
f) The operator should always have a clear view of the device, so that he/she
can stop the show immediately when there is danger.
g) Clear material for SPARKULAR® FALL for 5s after show, clear material will
remove the remaining particles from heating chamber. For angled installation
please elongate clear material time.
7. Turn off and Clean up
a) Power off SPARKULAR® FALL, allow SPARKULAR® FALL to cool down.
b) Disconnect all POWER and DMX cables. Remove the machine from truss
carefully.
c) Empty the remaining HC8200 in hopper, and store the remaining HC8200 in a
dry sealed bottle for next time use. Never touch the output nozzle of
SPARKULAR® FALL when empty the hopper. DANGER OF GET BURNT!
d) Clean the surroundings to remove powder residues.
Wireless Control Information
1. Wireless remote control mode: When use wireless remote control, please unplug DMX cable connection on machine, set Wireless Control at ON status, match the remote controller with machine, pull out the antenna on remote controller.
1 ON| DMX address “1” ON| 1 OFF| DMX address “1” OFF|
---|---|---|---|---
2 ON| DMX address “3” ON| 2 OFF| DMX address “3” OFF
3 ON| DMX address “5” ON| 3 OFF| DMX address “5” OFF
SET| Match the machine with remote| CLEAR| Clean material for 3
seconds
5 S| All firing 5s| 15 S| All firing 15s
30 S| All firing 30s| OFF| All stop
NOTE:
a) When the indicator light becomes weak on the remote controller, please
replace the battery.
b) When the machine is occasionally not working, may be caused by
interference, please press the start button again.
c) Wireless control is easily influenced by interference, suggests to stay as
close to machine as possible when use remote controller, and machines cannot
use metal shielding
3. Wireless host SPARKULAR® FALL mode (requires communication cables)
a) In occasion of strong interference, using the wireless host can avoid
interference, ensure stable control.
b) Set the first unit of SPARKULAR® FALL DMX address into “1++”, this machine
address is “1”, but it can also output DMX signal and turns into wireless host
SPARKULAR® FALL.
c) Use communication cables to connect all SPARKULAR® FALL, the host
SPARKULAR® FALL will receive the signal from remote controller and transfer to
all other SPARKULAR® FALL via communication cable to realize stable signal
transmission.
Maintenance
a) Empty the feeding hopper before shipment of machine.
b) Empty the feeding hopper if long time not use, for high humidity
environment we suggest to empty feeding hopper after show.
c) Clear material both before and after the show for SPARKULAR® MOBILE.
d) Recommended to wash or replace the air intake filter every two months.
e) Please fully charge SPARKULAR® MOBILE if not use for a period of time.
f) Remember to recharge it at least every two months no matter use it or not.
Warranty Instructions
- Sincere thanks for your choosing our products, you will receive quality service from us
- The warranty period of battery of SPARKULAR® MOBILE is 6months after shipping out from our factory.
- The main part of SPARKULAR® MOBILE warranty period is one year. If there are any quality problems within 7 days after shipping out from our factory, we can exchange a brand new same model machine for you.
- We will offer free of charge maintenance service for machines which with hardware malfunction (except for the instrument damage caused by human factors) in warranty period. Please don’t repair machine without factory permission
Below situations NOT included in warranty service:
- Damage caused by use other type of consumable which is not originally from SHOWVEN®.
- Damage caused by improper transportation, usage, management, and maintenance, or dam- age caused by human factors;
- Disassemble, modify or repair products without permission;
- Damage caused by external reasons (lightning strike, power supply etc.)
- Damage caused by improper installation or use;
For product damage not included in warranty range, we can provide paid
service.
Invoice is necessary when applying for maintenance service from SHOWVEN®.
**https://www.facebook.com/Showven-228026294663699/?modal=admin_todo_tour
Showven Technologies Co., Ltd.
Tel: +86-731-83833068
Web:www.showven.cn E-mail:
info@showven.cn
Add: No.1 Tengda Road, Liuyang Economic & Technical
Development Zone, Changsha, Hunan,
410300, P.R.China**
Documents / Resources
|
SHOWVEN 20240624 Sparkular
Case
[pdf] User Manual
20240624 Sparkular Case, 20240624, Sparkular Case, Case
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>