NAKAYAMA NP2015 Surface Electric Pumps Instruction Manual
- September 17, 2024
- NAKAYAMA
Table of Contents
NAKAYAMA NP2015 Surface Electric Pumps
Product Usage Instructions
Installation:
The pipe must always be fitted using the related brackets to avoid transmitting stress to the pump body. Take care not to damage any part by over-tightening the pipes when fitting them.
Frequently Asked Questions
-
Q: Can children operate the equipment?
- A: No, children and youths are not permitted to operate the equipment for safety reasons.
-
Q: What are the conditions of proper use for the pump?
- A: The pump may maintain normal and continuous operation under the following conditions:
- Maximum Ambient Temperature: +40°C
- Maximum Water Temperature: +60°C
- Maximum Operating Pressure: 8 bar
- Maximum Altitude: +1000m
-
Q: What are the different types of water pumps available?
- A: The product offers various types of water pumps including Automatic Self-Priming Water Pump, Self-Priming Water Pump, Centrifugal Water Pump, Peripheral Water Pump, and Multilevel Water Pump, each with specific features and applications.
WARNING! READ THROUGH THE INSTRUCTIONS FOR USE BEFORE STARTING UP THE EQUIPMENT. Failure to follow all instructions listed below, may result in electric shock, fire and /or serious personal injury. Persons, who are not familiar with the instructions, may not operate the equipment. Keep the instructions for use in safe custody. Children and youths are not permitted to operate the equipment.
GENERAL SAFETY RULES
-
In order to operate the equipment safely, the users shall carefully read and understand the instructions before the first application. The users shall obey all safety instructions. Otherwise, you and others may suffer from injury.
-
You shall preserve all application and safety instructions for the further reference. The equipment shall be used when it has normal functions.
-
Please use the equipment according to the safety and technical requirements as specified in the instructions.
-
The equipment shall be used within its performance range. Please don’t use the equipment which has abnormal switch.
-
Please don’t use the equipment in the room which contains the inflammable and combustible liquid or gas.
-
When the components which fail to be tested and recognized by manufacturers are improperly used, the equipment is likely to suffer from the unforeseen damage.
-
Any application which deviates from the intended purpose as specified in the instructions will be considered as the unauthorized application, as a result, the
generated problems are independent of the manufacturers. -
The equipment shall be connected to the socket which has correct installation and grounding.
-
Please ensure that the power supply can satisfy the connection regulations before the equipment connection.
-
Please don’t bend, extrude, pull or drive the power wire to avoid the related dangers caused by line breakage.
-
Please check the plug and power cable before application. When the power cable has been damaged, please disconnect the plug immediately. Please don’t use the equipment which has damaged power line.
-
When the equipment is idle, please ensure that the plug has been pulled out. Meanwhile, the equipment has been closed, then, unplug the power supply.
Electical connections
- The installer is responsible for making the electrical connections to the main power supply in compliance with the relevant regulations in force.
- Note that international regulations demand that fixed installations incorporate a device ensuring Omni polar disconnection from the main power supply.
- Make sure that the specifications on the pump rating plate and the rated line values are the same (Fig.D).
- Connect the pump to an effective earth circuit and then connect up the phases following the diagram on the terminal block cover rating plate.
- Check that three phase pumps stage clockwise when looking at the pump from the motor fan side, swapping over two of the phase connections if they do not.
CONDITIONS OF PROPER USE
The pump may maintain normal and continuous operation in the following conditions:
- Maximum Ambient Temperature : + 40 oC
- Maximum Water Temperature: + 60 oC
- Maximum Operating Pressure: 8 bar
- Maximum Altitude + 1000m
- The pump must be earthed safely.
- The pump must be set on a dry base.
- Do not operate the pump without water.
- The pump only use for pumping clean water or liquids similar to water without sands.
OVERVIEW OF PUMPS
-
A. AUTOMATIC SELF-PRIMING WATER PUMP:
These pumps are equipped with automatic functions. It means that when the output valve opens, the pump operates and vice versa. -
B. SELF-PRIMING WATER PUMP:
These pumps have a monolithic structure and self-priming function with high hydraulic performance and a considerable pressure capacity. -
C. CENTRIFUGAL WATER PUMP:
These pumps with large output flow, can provide stable operation and low noise; Most of the pumps use for irrigation purposes. -
D. PERIPHERAL WATER PUMP:
These pumps with feature of a simple structure but with high heads its efficiency is low. -
E. MULTILEVEL WATER PUMP:
These pumps with several impellers which to be able to develop high pressure and highwater lift but with low power consumption.
SPECIFICATIONS
Technical Data
Model| NP2015| NP2025| NP2108| NP2065| NP2045
Description
| ****
Volumetric Water Pump
| ****
Volumetric Water Pump
| Automatic Self Priming
Jet Pump
| Centrifugal Pump 2 stages| Jet Surface Water Pump
Rated Power| 370 Watt| 750 Watt| 750 Watt| 1500 Watt| 800 Watt
Max. Head| 40 m| 70 m| 50 m| 50 m| 50 m
Max. Conveying Amount| 2100 L/h| 2700 L/h| 3000 L/h| 8400 L/h| 3000 L/h
Diameter of inlet & outlet| 1”x 1”| 1”x 1”| 1’’x 1”| 1.25″x1″| 1’’x 1”
- The manufacturer reserves the right to make minor changes to product design and technical specifications without prior notice unless these changes significantly affect the performance and safety of the products. The parts described/illustrated in the pages of the manual that you hold in your hands may also concern other models of the manufacturer’s product line with similar features and may not be included in the product you just acquired.
- To ensure the safety and reliability of the product and the warranty validity, all repair, inspection, repair or replacement work, including maintenance and special adjustments, must only be carried out by technicians of the authorized service department of the manufacturer.
- Always use the product with the supplied equipment. Operation of the product with non-provided equipment may cause malfunctions or even serious injury or death. The manufacturer and the importer shall not be liable for injuries and damages resulting from the use of non-conforming equipment
INSTALLATION
The pumps must be installed in a dry well-ventilated place with an ambient temperature of not more than 40oC (Fig.A). Fix the pump in place on a solid flat surface using suitable bolts to avoid vibration. The pump must be installed in a horizontal position to ensure that the bearings operate correctly. The diameter of the intake pipe must not be smaller than that of the intake month. If the intake height exceeds 4 meters, use a pipe with larger diameter. The diameter of the delivery pipe must be chosen to suit the flow rate and pressure required at the take off points. The intake pipe must be slight angled up towards the intake mouth to avoid the formation of air locks (Fig.B). Make sure that the intake pipe is completely airtight and immersed in the water by at least half a meter to avoid the formation of vortexes. Always fit a foot valve at the end of the intake pipe. It is advisable to fit a non-return valve between the delivery mouth and flow rate adjustment gate valve to avoid dangerous water hammering in the event of the pump suddenly stopping. This measure is compulsory if the delivery water column is over 20 meters. The pipe muse always be fitted using the related brackets (Fig.C) to avoid transmitting stress to the pump body. Take care not to damage any part by over-tightening the pipes when fitting them. Fill the pump completely with clean water before switching it on. The water should be poured in through the priming plug (Fig.F). When you have completed the operation screw the plug back in again and start the pump. The pump should be primed again whenever it has not been used for a long period of time or when air has made its way into the system.
MAINTENANCE
NEVER CARRY OUT ANY WORK ON THE PUMP WITHOUT HAVING FIRST DISCONNECTED IT FROM THE MAIN POWER SUPPLY. FAILURE TO TAKE THE FOLLOWING PRECAUTIONS COULD DAMAGE YOUR PUMP AND INVALIDATE THE GUARANTEE.
- Our pumps do not require any maintenance provide one takes the following precautions: When there is a risk of freezing empty the pump through the drain plug on the bottom of the pump body. Make sure your prime it when subsequently starting it again.
- Check that the foot valve is clean at regular intervals.
- If the pump is to remain unused a long period of time (e.g. in the water ) (Fig.G), it is advisable to empty it completely rinse it with clean water and store it in a dry place.
- If the shaft does not turn freely, release it using a screwdriver inserting it in the special slot (Fig.H). If this is nor sufficient to solve the problem, remove the pump body, undo the relevant mounting bolts, and clean it thoroughly to remove any encrustation.
ΤROUBLESHOOTING
ΤROUBLESHOOTING
FAULTS| CAUSES| REMEDY
Failure to start.| Thermal protector acting. Thermal protector damaged. Faulty
cord connection.
Cord disconnected. Defective motor. Impeller stuck.
Too low voltage.
| If the motor is overheated, it does not operate.
Then, wait till getting cold (20 minutes). Replace with a new one.
Insert the plug securely. Connect the cord again. Replace the new cord. Repair or replace the motor. Clean the impeller.
Consult with the power supply company.
Motor runs without pumping water.| The water level of well is lower than the standard level or suction lift too high.
Trouble in non-return valve.
Filter apparatus or foot valve blocked. Air drawn into suction pipe.
Air is drawn into pump from the mechanical seal.
| Check the water level of well.
Move the pump closer to water intake level.
Take off the non-return valve cover, then clean the valve, the valve seat and the valve hole. Clean both of them.
After checking the joints of piping, tighten them perfectly. Make sure the foot valve is immersed by at least 50cm. Replace the new mechanical seal.
Thermal protector for motor works too often.| oo low or high power supply voltage. The impeller is in contact with another part. Impeller blocked.
Short open circuit of the capacitor.
| Consult with the power supply company. Check and repair the defects.
Clean the impeller. Repair the capacitor.
Water does not come out from pump at
the first few minutes after switch on.
| Air is drawn in suction pipe.| Repair the defects of piping. (To prevent air
leaking)
Pump starts though no water is being
used.
| Water leaks at piping or pump. Water leaks at the mechanic seal.| Repair
piping, pump parts and faucets etc. Replace the mechanical seal.
Flow rate insufficient.| The suction lift reached the limit.
Filter apparatus or foot valve blocked partially
dogged.
Impeller blocked.
| Check the suction lift.
Check valve or filter apparatus and check the whole suction piping if necessary.
Disassemble pump and carefully clean pump body and
impeller.
Models
WARRAΝΤΥ
The power tools have been manufactured according to strict standards, set by our company, which are aligned with the respective European quality standards. The power tools of our company are provided with a warranty period of 24 months for non-professional use, 12 months for professional use and 12 months for chargers and batteries. The warranty is valid from the date of purchase of the product. Proof of the warranty right is the purchase document of the tool (retail receipt or invoice). Under no circumstances shall the company cover the relevant cost of spare parts and respective required working hours unless a copy of the purchase document is presented. In case the repair has to be done by our service department the cost of transportation (to and from) is entirely borne by the sender (client). The tools must be sent for repair to the company or to an authorized workshop in the appropriate way and means of transport.
WARRANTY EXEMPTIONS AND RESTRICTIONS:
- Spare parts that wear out naturally as a consequence of being used (brushes, cables, switches, chargers, chokes etc.).
- Tools damaged as a result of non-compliance with the instructions of the manufacturer.
- Tools poorly maintained.
- Use of improper lubricants or accessories.
- Tools given to third entities free of charge.
- Damage due to an electrical connection at a voltage other than that indicated on the appliance plate.
- Connection to a non-earthed power supply.
- Change in current voltage.
- Damage resulting from the use of salty water (e.g., washing machines, pumps).
- Damage or malfunction resulting from improper cleaning procedure of the tool.
- Contact of the tool with chemicals, or damage as a result of moisture or corrosion.
- Tools that have been modified or opened by unauthorized personnel.
- Tools used for rent.
The warranty covers only the free of charge replacement of the component that presents a manufacturing defect or material failure. In case of lack of a specific spare part the company reserves the right to replace the tool with another corresponding model. After all warranty procedures have been concluded, the warranty period of the tool shall not be extended or renewed. Replacement of a spare part with repair charge is covered by a 1 year warranty of good operation, subject to compliance with the warranty terms. The spare parts or tools that are replaced remain in the possession of our company. Requirements, other than those mentioned in this warranty form, regarding power tools repair or damage thereof, do not apply. Greek law and relative regulations apply to this warranty.
The instructions manual is also available in digital format on our website www.nikolaoutools.com. Find it by entering the product code in the Search field.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>