Product Specifications:

  • Model: 14-RTE433T

  • Power Source: AC/DC

  • Battery: CR2032

  • Components: Key Switch Keys, Lock Key, Carriage Bolt (4x), Hex
    Nut (4x), Hole Plug, Screwdriver

  • Features: Exit Button, Key Switch, Pairing Buttons, Relay
    Release Button, Connection Terminals, Power LED, Relay Status LED,
    Status LED, Programming Button, Programming LED

Product Usage Instructions:

1. Unpacking and Assembly:

Ensure all components are present as listed in the manual.

2. Mounting the RTE Unit:

Unlock and remove the faceplate of the RTE unit. Attach the unit
to the pedestal using the provided carriage bolts and hex nuts.

3. Installing the Transceiver:

Securely attach the transceiver to a wall or surface inside the
gate operator using Tek screws or zip ties.

4. Connecting the Transceiver:

Follow the wiring instructions for connecting the transceiver to
the gate operator or door opener based on your specific model.

5. Pairing Process:

a. Remove the transceiver cover and press the Programming Button
on the circuit board for 5 seconds.

b. Remove the faceplate of the RTE unit.

c. Hold down both Pairing Buttons until the Status LED flashes.
Release Button 2 and continue holding Button 1 until the Status LED
flashes again.

d. The relay on the transceiver should click, and the
Programming LED should turn off, indicating successful pairing.

6. Testing:

Press the Exit Button on the RTE unit and confirm that the
gate/door opens. If there are issues, refer to the troubleshooting
section in the manual.

Frequently Asked Questions (FAQ):

Q: What should I do if the gate/door does not open after

pairing?

A: Repeat Step 5 of the pairing process. If the issue persists,
refer to the troubleshooting section on Page 4 of the manual for
further assistance.

“`

INSTALL GUIDE

1 Unpack box and make sure you have everything shown here.

1 of 4
Model 14-RTE433T

RTE Unit

Key Switch Keys

(includes battery) (may look different)

Lock Key

Carriage Bolt ( 4x )

Hex Nut ( 4x )

Hole Plug

Screwdriver

What’s what?
Important components labeled
Lock
For securing interior of RTE Unit
Exit Button
Triggers gate/door to open
Key Switch
For enabling and disabling unit (Unit is disabled as shown)
RTE Unit Faceplate (Front)

BTN 1 BTN 2

RTE Unit Faceplate (Back)
Internal wiring not shown for clarity.

Pairing Buttons
For pairing RTE unit with transceiver
Relay Release Button
For manually releasing relay when active

Connection Terminals
For wiring to compatible AC/DC power source and gate operator or door opener
Power LED
Indicates whether or not unit has power
Relay Status LED
Indicates whether relay is active or inactive (Relay is active when lit)

CR2032 Battery
On underside of circuit board
Status LED
Indicates transmitting status

Programming Button
For pairing transceiver with RTE unit
Programming LED
Indicates status of pairing process

Transceiver (Sold Separately)
Shown with cover removed. Internal wiring not shown for clarity.

INSTALL GUIDE
2 Unlock and remove faceplate of RTE unit; then using included carriage bolts and hex nuts, attach unit to pedestal as shown.

3 Using Tek screws, zip ties, or other means of securing, attach transceiver to inside wall or other surface inside gate operator.

2 of 4
Model 14-RTE433T

CAUTION

The transceiver is not weatherproof and must be mounted inside a weatherproof enclosure. Internal components can be damaged if exposed to the elements.
Failure to comply will VOID WARRANTY.

WARNING

AUTOMATIC GATES CAN CAUSE SERIOUS INJURY OR DEATH! ALWAYS CHECK THAT THE GATE PATH IS CLEAR BEFORE OPERATING! REVERSING OR OTHER SAFETY DEVICES SHOULD ALWAYS BE USED!

4a Connect transceiver

Gate Operator Timer-to-Close
OFF

Ridge Transceiver
12­24 VAC/DC
POWER RELAY

Gate Operator / Door Opener
12­24 VAC/DC
POWER

4b Connect transceiver

Gate Operator Timer-to-Close
ON

Ridge Transceiver
12­24 VAC/DC
POWER RELAY

Gate Operator / Door Opener
12­24 VAC/DC
POWER

OR

NEG. (­) POS. (+)
NC COM
NO POS. (+) NEG. (­)
COM RADIO
COM FREE EXIT
COM REVERSE LOOP
COM OPEN STOP CLOSE NEG. (­) POS. (+)
NC COM
NO POS. (+) NEG. (­)
COM RADIO
COM FREE EXIT
COM REVERSE LOOP
COM OPEN STOP CLOSE

12­24-VAC/DC Power Source (Not Included)
© 2024 Security Brands, Inc. All rights reserved.

Consult gate operator or door opener manual for exact connections.
Terminals vary widely across manufacturers and models.

12­24-VAC/DC Power Source (Not Included)

Consult gate operator or door opener manual for exact connections.
Terminals vary widely across manufacturers and models.

CAUTION
A closing gate can cause injury to persons or damage to property. ALWAYS USE SAFETY DEVICES!
IG-14RTE433T-EN-US Rev. A (8/2024)

INSTALL GUIDE

5a Remove transceiver cover; then hold down Programming Button on circuit board for 5 seconds and let go.
LED will light and stay on

5b Remove RTE unit faceplate.

BTN 1 BTN 2

3 of 4
Model 14-RTE433T
5c Hold down both Pairing Buttons until Status LED flashes. Let go of Button 2, and continue holding Button 1 only until Status LED flashes again.

5d Relay on transceiver should click and Programming LED should go out. Pairing is now complete.
LED will go out

6 Press Exit Button on RTE unit and confirm gate/door opens. (If nothing happens, repeat Step 5. If gate/door is held open, see Troubleshooting section on Page 4.)
CHECK THAT THE GATE PATH IS CLEAR BEFORE COMPLETING THIS STEP AS IT TRIGGERS THE RELAY!

CHECK THAT THE GATE PATH IS CLEAR BEFORE COMPLETING THIS STEP AS IT TRIGGERS THE RELAY!
N
INSTALLATION COMPLETE!
Your system is ready to use.

A The RTE unit can be disabled and re-enabled at any time by taking the key switch keys and using the Key Switch located below the Exit Button.

Unit Enabled
(Exit Button active)

Unit Disabled
(Exit Button inactive)

B Reset Procedure (Transceiver)
IMPORTANT: FOLLOWING THIS PROCEDURE WILL UNPAIR ALL DEVICES (KEYPADS, RTES, AND REMOTES) FROM THIS UNIT! NOTE: Transceiver must have power.
Step 1 – Remove screws and remove transceiver cover. Step 2 – Press and hold Programming Button until Programming LED starts to flash. Button must be held for about 30 seconds. Once flashing stops, all devices have been unpaired from transceiver and reset is complete. Step 3 – Replace transceiver cover and secure screws.

INSTALL GUIDE
C Troubleshooting
Gate/door is being held open
IMPORTANT: GATE/DOOR MUST BE CLOSED BEFORE COMPLETING THIS PROCEDURE! NOTE: Unit must have power. Step 1 – Press Exit Button on RTE unit to close gate/door if it is not already closed. Step 2 – Hold down both Pairing Buttons and pay attention to Status LED. Step 3 – When Status LED flashes twice, continue holding BOTH buttons. Step 4 – When LED flashes twice again, continue holding Button 1 ONLY until Status LED flashes multiple times. Now the RTE unit should only hold the gate/door open momentarily. NOTE: If gate/door is still held open and Relay Status LED is lit on transceiver, press Relay Release Button to release hold. NOTE: If gate/door is still held open, contact a gate/door specialist.
Gate/door is opening/closing without input from RTE unit
Complete Section B to reset transceiver.
RTE unit has limited range
IMPORTANT: DISCONNECT FROM POWER BEFORE COMPLETING THIS PROCEDURE! Step 1 – Check position of blue wire coil on transceiver. It should be secured in the terminal block labeled “ANTENNA” and, if you unscrew and flip the circuit board over, this should correspond to the position above five-hole pattern. Step 2 – If antenna wire coil is in wrong position, unscrew terminal block, move wire coil to next terminal block, and screw down to secure.

© 2024 Security Brands, Inc. All rights reserved.

Call 972-474-6422 Email support@summitcontrol.com
We are available Mon­Fri / 8am­5pm Central

4 of 4
Model 14-RTE433T
Ridge RTE 14-RTE433T
IG-14RTE433T-EN-US Rev. A (8/2024)

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

SECURITY BRANDS User Manuals

Related Manuals