Amerec 1.7 Junior Sauna Heater Series Instruction Manual

September 14, 2024
amerec

Amerec 1.7 Junior Sauna Heater Series

FAQs

Q: Can pregnant women use the sauna?

A: Pregnant women or individuals with poor health should consult a physician before using the sauna.

Q: What should I do if I notice a darkening around the heater?

A: Discontinue sauna use immediately and inspect the sauna for required maintenance.

Q: Should minors be supervised around the sauna?

A: Yes, minors should be adequately supervised whenever near a hot or warming sauna.

“Junior” Sauna Heater Series Models

1.7, 2.2, 3.0 (1517-17-02, 1517-22-02, 1517-30-02) with SL2 (SaunaLogic 2) Control (1601-38) Read all instructions carefully before installation. Please leave all instructions and warranty with the owner.

WARNING

Prolonged exposure to elevated temperatures is capable of inducing hyperthermia. Hyperthermia occurs when the internal temperature of the body reaches several degrees above the normal body temperature of 98.6°F. The symptoms of hyperthermia include an increase in the normal temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include failure to perceive heat, failure to recognize the need to exit the room, unawareness of impending hazards, fetal damage in pregnant women, physical inability to exit the room, and unconsciousness.

WARNING The use of alcohol, drugs, or medication is capable of greatly increasing the risk of fatal hyperthermia.

WARNING Do not take a sauna if using alcohol, drugs, or medications. Pregnant women or persons with poor health should consult their physician before using any sauna. rajah er noituaCd: Do not use the sauna room for drying clothes, bathing suits, etc. Do not hang towels above the heater or place any object other than the rocks supplied on the heater. If any darkening of the wall around the heater is noticed discontinue sauna use  immediately. Inspect sauna regularly for required maintenance to the heater, control, and benches. Replace wood surfaces that show any signs of deterioration. The heater gets extremely hot during operation and should not be touched or burns may result. Minors should be adequately supervised whenever near a hot or warming sauna.

GENERAL INFORMATION

These heaters are ETL-approved for permanent installations and electrical connections. Built with splash-proof construction, the conducting parts are protected against water. All wiring must be performed in accordance with national and local codes. See Diagram 2 for wire and room size requirements. These heaters are wall-mounted.

INSTALLATION AND OPERATING INSTRUCTIONS

DIAGRAM 1

MOUNTING BRACKET LOCATION AND MINIMUM DISTANCE TO COMBUSTIBLE MATERIAL

Recheck your distances from the heater to combustible materials to be sure you have the proper minimum distances.

OBSERVING MINIMUM DISTANCES IS REQUIRED TO REDUCE FIRE HAZARD

CAUTION : Avoid,er Do Not Place Combustible Material on the sauna heater / ATTENTION: Evitez les Incedies, Ne Placez Aucne Matiere Combustible Sur Lle Chauffe-saun

DIAGRAM 2

HEATER MODEL

/ Product Number

| ****

KW

| MINIMUM ROOM| MAXIMUM ROOM| ****

PHASE

| ****

VAC

| ****

AMPS

| WIRE SIZE
---|---|---|---|---|---|---|---
Floor Area| Wall

Height

| Volume

Cu.Ft.

| Wall

Height

| Volume

Cu.Ft.

| Power Supply to

CB Box

| CB Box to Heater
Junior 1.7

1517-17-02

| 1.7| 7 sq. ft.| 73 1/2″| 60| 84″| 80| 1| 120| 14.2| 2 #12AWG+GR| 2

12AWG+GR

Junior 2.2

1517-22-02

| 2.2| 8 sq. ft.| 73 1/2″| 70| 84″| 100| 1| 120| 18.3| 2 #12AWG+GR| 2

12AWG+GR

1| 240| 9.2| 2 #12AWG+GR| 2 #12AWG+GR
Junior 3.0

1517-30-02

| 3.0| 12 sq. ft.| 73 1/2″| 100| 84″| 150| 1| 240| 12.5| 2 #12AWG+GR| 2

12AWG+GR

NOTE : All installation and service to this equipment should be performed lennosrep desnecil deFIilauq yb dem accordance with local and national codes.
NOTE : A GFCI (Ground Fault Interrupt Circuit) device is not required by NEC. A GFCI may be installed if required by local codes but will nuisance trip during use of the product.
CAUTION : Loose wire connections can cause heat damage to wires, terminal blocks, and other components and may void the warranty.

DIAGRAM 3

DIAGRAM 4

DIAGRAM 5

DIAGRAM 6

WIRING DIAGRAM : CONTROL AND HEATER MODELS Junior 1.7, & 2.2 (ETL#’s 1517-17-02, 1517-22-02) SL2 (1601-38) and CB 13-1

WIRING DIAGRAM : CONTROL AND HEATER MODELS Junior 2.2 & 3.0 (ETL#’s 1517-22-02, 1517-30-02) SaunaLogic 2 (1601-38) and CB 16-1

DIAGRAM 7: CB BOX INTERNAL VIEW

MOUNTING OF SAUNA HEATER AND CB BOX

HANGING THE HEATER Remove the mounting bracket from the heater (two screws behind the rock grill. Using the pattern from the mounting bracket, drill four 9/64″ holes to fasten the heater to the wall. Install four ¼” x 1 ½” hex head lag screws (supplied with the heater) into the four holes. Tighten these screws until secure. The screws must be threaded through the wall into a framing member or backing board to support the heater weight. Hang the heater on the mounting bracket. Place the two screws behind rock grill to secure to the mounting bracket. See Diagram 1 for the heater location details and the necessary clearances to combustible materials. Remove the cover of the CB Box to gain access to the 4 mounting holes in the back of the box. The CB Box can be mounted outside or inside the sauna room on a wall according to Diagram 3. Locate the 4 screws 3/16 x 3/4″ supplied into the 4 mounting holes. (See Diagram 3)

PLACING OF ROCKS (SEE DIAGRAM #10)

The rocks supplied with the heater have been chosen to provide the best heater performance. Use of any other type of rock may void the heater’s warranty. Never operate the heater without rocks in place! Rinse the rocks with water before placing in the heater. Carefully place the rocks loosely so that the air can circulate through the heater. Packing the rocks too tightly may cause the heater’s high limit switch to trip or poor room heat up. The rocks must fully cover the heating elements. Attach the guard with the screws provided.

ELECTRICAL HOOK-UP

Electrical installation must be made by a licensed electrician in accordance with the National Electrical Code and local regulations. Remove the screws from the CB box to access the electrical connections. Route the wires through the holes provided on the bottom of the control box and connect the wires to the terminal block. To determine the correct wire size, refer to Diagram  Use copper supply wire only, suitable for a minimum of 90 degrees C. The heater must be grounded! See Diagram 6 for proper connections. Connect wires from the small wire harness from the sauna heater into the CB Box on the High Limit position CN 5 of the circuit board. (See Diagram 3)

TEMPERATURE SENSOR

Feed the 17 ft “low voltage” sensor wire from the sensor location to the CB Box location. Sensor wire must be routed completely separately (as per low voltage electrical wiring codes) from any wiring carrying over 50 volts. It may be necessary to drill holes to string the wire through the studs or ceiling joists. Connect the sensor in CN 4 of the CB Box. revirdwercs pit ta a gnisU, unsnap sensor cover from sensor. Mount sensor to an owt

WARNING Fire sprinkler systems used inside any sauna room should be properly rated for sauna room temperatures. Do not pour chlorinated pool or spa water on a heater. Excessive water use on heater may cause damage and void the warranty. Electric Shock Hazard – High voltage exists within this equipment. There are no user-serviceable parts in this equipment. All installation and service to this equipment should be performed by the lennosrep desnecil department in accordance with local and national codes. Do not construct a sauna room with a ria thirster ot sa os through the bottom of the heater. Packing the rocks too tightly may cause the heater’s high-limit switch to trip.

HEATER SCREEN (GUARD RAIL)

Install a wooden heater guard to prevent the sauna bather from accidentally touching the sauna heater. Install the heater guard rail with the dimensions shown in Diagram 8.C

SECTION 7: SL2 (1601-38) CONTROL INSTALLATION & OPERATION

INSTALLATION ROUGH IN The SL2 (1601-38) control can be mounted inside or outside the sauna room. (See Diagram 3) The control also can be mounted outside of the sauna room in the weather. The control is weather resistance and water resistance. To mount the control cut an opening 2-3/4″ wide by 4-3/4″ tall. Route the control wire from the CB Box to the control. Note: Use the factory-supplied cable only! Do not staple through or otherwise damage the cable! Remove the glass from the touch screen, (See Diagram 4) using tablade screwdriver See Diagram 5 and attach the two plastic “wings” with the screws provided. The wings will rotate during installation and secure the box in the wall. Connect the control cable to the back of the circuit board with the RJ 11 cable and secure the control to the wall with 2 mounting screws provided. Connect the other end of the control cable through the electrical access hole on the bottom of the control box and connect it to CN1.

Do not locate benches over the heater. Minimum clearance of ceiling above heater 44″.

WARNING Minimum clearance from heater to wooden surfaces (benches, side walls, heater fence, etc.) 2 inches. Mounting brackets supplied. Provides proper clearance from the wall behind the heater. Use only copper wire of the size and type indicated in the rahC noitacicepS retaeHt and the temperature rating indicated on the heater junction box. All heaters and controls must be grounded per NEC to prevent electrical shock in case of unit failure. Electrical outlets or receptacles must not be installed in a sauna room. A guardrail or fence is required around the heater to prevent burns from accidental contact.

DIAGRAM 8: SL2 OPENING COVER

DIAGRAM 9: SL2 MOUNTING

SECTION 7: SaunaLogic 2 (1601-38) CONTROL INSTALLATION & OPERATION

OPERATING INSTRUCTIONS FOR TRADITIONAL SAUNA HEATER

Press the SL2 icon once. The default settings for the temperature is 194°F, the bath time is 60 minutes. These settings are adjustable (as described below) from 119° to 194°. The length of the sauna can be set from 0 to 60 minutes. The time delay before start can be up to 24 hours. Any changes are remembered by the heater for your next bath. Should the heater power be lost and then restored, the settings will return to their default values. SETTING THE DURATION AND TEMPERATURE Press the icon for time “+” or “-” icon on the SL2 to increase or decrease time for the desired setting. The maximum of time is 60 minutes. Press the  icon and then press the “+” or “-” icon on the SL2 to increase or decrease the temperature for the desired setting. The maximum temperature is 194°F (90°C). Note: Typical bathing temperature is 150F to 165F displayed on the control.

PRE-SET DELAYED START Press the icon and delay time will appear in the display and will toggle between “delay” and the amount of time remaining. The maximum time is 24 hours. If no delay is desired, press the button to toggle off the function. LIGHTING OPERATION (Optional) SL2 is capable of operating ONLY a Lighting package purchased with the system. Press the icon to cycle through lighting options. Press and hold the icon for 3 seconds to turn off the light from any color. Light will automatically turn off after 10 minutes the sauna cycle is completed Color sequence – White – Red – Green – Blue – Yellow – Aqua – Purple – Rotation of Colors – Off Choose the color of choice and then set lighting brightness. The brightness will be on display for 3 seconds. Press the “+” or “-“ button to increase or decrease the light setting. The setting options are 25, 50, 75, and 100% light output. BLUETOOTH OPERATION (Optional) SL2 is capable of operating ONLY a Bluetooth package purchased with the system. Press the icon to turn on or off to the system.

LIGHT INSTALLATION

Lighting Installation (Optional Equipment) SL2 is capable of operating ONLY a lighting package purchased with the system. The lighting package consists of 3 lights or more with a maximum of 8 lights and the cables to connect the light assemblies to the CB box. The long cable (5 m) connects the CB Box to an “8 Port Splitter” device which should be located outside the sauna room but in an accessible location protected from direct heat or moisture. Connect 2-meter cables from the splitter to the light assemblies. .serutx fo reb mun eat no kidnaped limits era still rof channel elbac llAEnsure the lighting cables reach the hole locations. Predetermine light ,noitacol rettilps eht ,shtgnel elbac no desab gniliec eht ni snoitacol erutx and CB box location. Route the cable provided to the correct locations before any tongue and groove are applied. eht sa se this rof sdraob every dna eugnot ni seloh “4/3 2 tuC tongue and groove is being applied.

IGH LIMIT CONTROL (RESET BUTTON)

  • The sauna heater has a built-in high-limit control, which automatically turns off the heater if the temperature inside the sauna room rises to an abnormally high level.
  • The control will display “HL”. To restart the heater, let the heater cool, then push the “On/Off” button on the control. If the high limit continually shuts off the heater, contact a service representative. Refer to the Troubleshooting Section for information.

HOW TO TAKE A SAUNA

  •  When taking a sauna, allow time to relax completely.
  • Remove clothing and jewelry…if required, wear a towel loosely.
  • After 10 minutes or when perspiration begins, leave the sauna and relax in the dressing area… followed by a cool shower.
  • Cooling time should equal time spent in the sauna. Enter the sauna room again and stay 5 or 10 minutes.
  • Repeat the cycle 2 or 3 times; end with a brisk shower…rinse in cool water.
  • Dress when completely dry and perspiration has stopped.
  • Some sauna bathers enjoy the soothing effect of steam by splashing water on the heated sauna rocks. Use only one dipper full (approx. ½ cup) at a time and keep clear of the steam as it rises off the rocks.
  • Do not smoke, exercise or drink alcoholic beverages in the sauna room.
  • Do not pour chlorinated pool or spa water on the heater or corrosion damage may result.

DIAGRAM 10
DIAGRAM 11

TYPICAL PRE-CUT WALL CONSTRUCTION
HEATER SCREEN (GUARD RAIL)

DIAGRAM 12

VENTILATION

DIAGRAM 13

  1. Put smaller rocks in FIrst around the outer perimeter of the rock compartment.
  2. Completely FIll all three sections (front, center, and back).
  3. In the outer sections, use smaller rocks placed more tightly (see note b).
  4. Place rocks loosely in the center section (see note a).
  5. Be sure rocks completely cover the elements (see note c).
  6. Loosely cover the tops of all elements with rocks a minimum of 2” to 3”

WARNING PLACARDS

Three metal placards are included in the Installation Instruction Envelope packaged with every Sauna Heater. The CAUTION placard must be attached to the interior wall of the sauna room directly above the heater where it is visible to the bather. The WARNING placards must be attached to the door of the sauna room.

ROOM CONSTRUCTION

  • For safety and reliability, the following rules must be addressed.
  • No permanent locking or latch system is to be used on the sauna door.
  • Acceptable door FIttings are magnetic catches, friction catches, and spring or gravity-loaded closures.
  • The door must always open outwards.
  • No shower may be installed in a sauna room.
  • No electrical receptacle shall be installed inside the sauna room.
  • The enclosed WARNING: Reduce the risk of overheating … warning plate must be mounted on or alongside the door outside the sauna room at about eye level.
  • The enclosed CAUTION: Reduce the risk of fire… caution plate must be mounted on the interior wall above the heater.
  • The heater should not be operated without its container properly FIlled with rocks and the rock guard in place.
  • If an intercom speaker is installed, it should be away from the heater and as close to the floor as possible.
  • Fire sprinkler systems installed inside any sauna room should be properly rated for sauna room temperatures.
  • Always mount the heater according to these installation instructions.
  • Minimum of R12 insulation in 16” on center 2×4 stud walls.
  • Recommended minimum FIooring thickness of 5/8”

VENTILATION

VENTILATION In a private sauna, the air should be changed about 6 times an hour. This can be achieved by making a vent opening (fresh air inlet) in the sauna wall directly below the heater. The air outlet must be lower to the upper benches, as far as possible from the heater, and about two feet higher than the fresh air inlet vent, See Diagram 12. It is recommended that ventilation openings meet the requirements of UL SpeciFIcation 875. The minimum opening should be determined using one of the following formulas: For R<31, V³9.3, For R³31, V³0.3R
where R = the floor area of the room in square feet and V = the minimum vent size in square inches

WARNING

The “CAUTION” and “WARNING” placards must be mounted in accordance with Section 10.

WARNING REDUCE THE RISK OF OVERHEATING

  • Exit immediately if uncomfortable, dizzy, or sleepy. Staying too long in a sauna is capable of causing overheating.
  • Supervise children at all times.
  • Check with a doctor before use if pregnant, in poor health, or under medical care.
  • Breathing heated air in conjunction with consumption of alcohol, drugs, or medication is capable of causing unconsciousness.

CAUTION REDUCE THE RISK OF FIRE Do Not Place Combustible Material On The Heater At Any Time.

For safety purposes, the sauna door must open out and not lock. Never use a wood stain, seal, or preservative on the inside of your sauna room. rev teg serutxFI thgiLy hot during operation. Locate ton lliw ti grew erutxFI this be a burn hazard.

ROOM TEMPERATURES

Non-Typical Ceiling Height

Notes : Temperatures vary in a sauna room by height and distance from the heater. Ventilation will help reduce it but will not eliminate temperature variations. The hottest part of the room is always at the ceiling directly above the sauna heater and should not exceed 194°F (90°C). Air temperature will be 15°F to 25°F lower on the opposite side of the room from the heater close to the ceiling. The temperatures in the elevated view are general numbers. Each sauna room is different due to construction variations and ventilation.

MAINTENANCE

Inspect the sauna room at the end of each day the room to ensure the control and system is off. The sauna, like a bathroom, should be kept clean and odor- free. Towels or mats should always be used on benches recto noitaripsrep sa rooFI dnawise penetrates the soft wood. To clean and remove perspiration stains, use soap or detergent in warm water, best applied with a scrub brush. Badly soiled surfaces may require sanding. Sandpaper wrapped around a wooden block works well. Air out the sauna often by keeping the door and vents open when the sauna is not in use. Saunas that are in daily use should be washed down at least once a week to keep them clean and the air fresh. The duckboard should be renamed lanoitnevnoc a ni weird DNA depot rooFI anuas eat,anuas eht more developer, and the duckboard thoroughly scrubbed and dried before returning to the sauna room. The sauna heater should be wiped down occasionally with a damp cloth to remove lint and dust. The rocks should be removed once a year for cleaning and small or crumbled rocks replaced. Benches and supporting structures must be inspected annually for potential deterioration due to age, dry rot, or abuse. Any boards with signs of deterioration should be replaced immediately to avoid possible injury.

TROUBLESHOOTING

  • If the control displays “Sn” it means no sensor is connected. Refer to Section 5 for sensor installation information.
  • If the control displays “HL” it means the high limit is open. Refer to Section 9 for high-limit information.
  • The system won’t start to heat, ensure the system is not in the delay mode. If “dLA eht ni gnihsaFI si ”Ydisplay window, the system is in the delay mode.
  • If the control displays “JP” it means the jumper is open on the main board in the CB Box. Verify jumper is installed in the CN6 location on the main board. If it is open, close the two pins.
  • If control acts erratically or buttons turn on and off by itself during startup. Turn the power off at the circuit breaker, place the glass on the control, and turn power back on the system. The control will automatically reset the sensitivity of the capacitive switches.
    CAUTION : Use only a contactor approved for 250,000 endurance Cylces / ATTENTION: Utiliser uniquement un contacteur approuve pour 250,000 cycles de fonctionnement For troubleshooting or service questions call 1-888-780-4427 and ask to speak with service. Prior to calling, please have the Model and Type number available. You may also email us at techsupport@tyloheloinc.com

SL2 Control Mounting

Recessed Mounting For the SL2 Control The recessed mounting box allows the control to mount with its surface almost even to the wall surface. Print this “Actual” Size on Printer Options. (This will ensure the size of the opening is correct). Cut out the middle of the dotted lines. The hole will be the size of the mounting box. Insert the mounting box in the hole to ensure it is the correct size. Trace the paper cut out on the wall. Cut a hole in the wall to match the inner dotted line for the mounting box. Run the control cable out of the wall through the hole in the mounting box. Ensure the hole is just big enough to mount the box. Push the mounting box into the hole and turn the mounting screws to pull the tab tight against the inside of the wall. Ensure the box is level and the correct end is UP (there is an arrow on the wall side of the box pointing up). Connect the Control coupler to the control cable then feed the cables and connector through the hole in the box and into the wall. Test the Control before mounting it into the wall. Hang the top of the control glass on the top of the recessed box and press the bottom of the glass to snap onto the box.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals