Amerec 7.0 Himalaya Pure A3 Series Sauna Heaters Instruction Manual

June 13, 2024
amerec

Amerec 7.0 Himalaya Pure A3 Series Sauna Heaters Instruction Manual
Amerec 7.0 Himalaya Pure A3 Series Sauna Heaters

INSTALLATION AND OPERATING INSTRUCTIONS

Himalaya Pure 2.0/Trend/A3 Series Sauna Heaters
Models 7.0, 9.0 (Type #’s 1118-702-1706, 1118-902-1706)
with Pure 2.0 Control (Type # 1601-40 and 1601-40-1).

Read all instructions carefully before installation. Please leave all instructions and warranty with the owner.

WARNING
Prolonged exposure to elevated temperatures is capable of inducing hyperthermia. Hyperthermia occurs when the internal temperature of the body reaches several degrees above the normal body temperature of 98.6°F. The symptoms of hyperthermia include an increase in the normal temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of the hyperthermia include failure to perceive heat, failure to recognize the need to exit the room, unawareness of impending hazard,  fetal damage in pregnant women, physical inability to exit the room and unconsciousness.

WARNING
The use of alcohol, drugs, or medication is capable of greatly increasing the risk of fatal hyperthermia.

SECTION 1: GENERAL INFORMATION

These heaters are ETL approved by Intertek for permanent installations and electrical connections. Built with splash proof construction, the conducting parts are protected against water. All wiring must be performed in accordance with national and local codes. See Diagram 2 for wire and room size requirements. This model of heaters are floor mounted.

WARNING
Do not take a sauna if using alcohol, drugs or medications.

Pregnant women or persons with poor health should consult their physician before using any sauna.

Caution fire hazard: Do not use the sauna room for drying clothes, bathing suits, etc. Do not hang towels above heater or place any object other than the rocks supplied on the heater. If any darkening of the wall around the heater is noticed discontinue sauna use immediately.

Inspect sauna regularly for required maintenance to heater, control and henches.

Replace wood surfaces which show any signs ofdeterioration.

The heater gets extremely hot during operation and should not be touched or burns may result.

Minors should be adequately supervised whenever near a hot or warming sauna.

DIAGRAM 1

MOUNTING BRACKET LOCATION AND MINIMUM DISTANCE TO COMBUSTIBLE MATERIAL
INSTALLATION AND OPERATING INSTRUCTIONS

CAUTION: Avoid fire, Do Not Place Combustible Material on sauna heater / ATTENTION:
Evita les Niceties, Ne Places Acne Mati ere Combustible Sur Lle Chauffer-s aunt

DIAGRAM 2

HEATER MODEL/ Product Number| KW| MINIMUM ROOM| MAXIMUM ROOM| PHASE| VAC| AMPS| WIRE SIZE
---|---|---|---|---|---|---|---
Floor Area| Wall Height| Volume Cu.Ft.| Wall Height| Volume Cu.Ft.| Power Supply to Heater
Himalaya Pure 7.0 1118-702-1706| 6.8| 21 sq. ft.| 75″| 175| 96″| 350| 1| 208| 32.7| 2 #8AWG+N+GR
1| 240| 28.3| 2 #8AWG+N+GR
3| 208| 18.9| 3 #10AWG+N EGR
3| 240| 16.4| 3 #10AWG+N+GR
Himalaya Pure 9.0 1118-902-1706| 9.0| 38 sq. ft.| 75″| 310| 96″| 500| 1| 208| 43.3| 2 #6AWG+N+GR
1| 240| 37.5| 2 #6AWGi N+GR
3| 208| 25.0| 3 #8AWG+N+GR
3| 240| 21.7| 3 #10AWG+N+GR

NOTE 1: Neutral s required for heater and control to operate. Light output from heater is 120 volts at 2 amps maximum.

SECTION 2: MOUNTING OF SAUNA HEATER

  • NOTE: Complete electrical connections and test the heater prior to this step.

Attach wall bracket to any of the mounting holes located on either side of the spine on the rear of the heater shroud (reference diagram 4). Slide heater into position, according todimensions shown in Diagram 1 and mark locations for the two mounting screws. Slide heater forward and screw two 1/4” x 1″ lag bolts into sauna wall at locations marked earlier, leaving approximately 1/8” of bolt shoulder exposed so bracket can easily slide over bolt heads. Re- locate heater into position with key-holes of bracket locking onto lag bolts. Adjust the leveling feet to ensure that the heater is vertical. Use a level on two sides of heater to verify plumb.

It mounting heater in center of room, use same procedure described above but locate
mounting bracket so that it can attach to the bench framing that surrounds the heater.

SECTION 3: PLACING OF ROCKS (SEE DIAGRAMS #10 and 11)

The rocks supplied have been chosen to provide the best heater performance. Use of any other type of rock may void the heaters warranty. Never operate the heater without rocks

in place! Rinse the rocks with water before placing in the heater. Install the BWT (Bio Water Technique) tank between the second and third heating elements resting on the top of the elements. (See diagram 11) The BWT tank has slots in the outer flange that will align with the element loops. Install the BWT cover and the round herb cup.

Start inserting rocks into the heater in even layers so that the 3 heating elements remain as vertical and evenly spaced as possible. Continue to randomly drop rocks into the heater until you are even with the top of the heating coils. Add one more loose layer to cover up the elements and top of the BWT. (Do Not Cover Up the round herb cub on top of the BWT!) The rocks must fully cover the heating elements. Attach the guard with the screws provided. See Diagram #10 & 11 for rock placement.

Packing the rocks too tightly may cause the heater high limit switch to trip.

SECTION 4: ELECTRICAL HOOK-UP

Electrical installation must be made by a licensed electrician in accordance with the National Electrical Code and local regulations.

  • NOTE: A GFCI (Ground Fault Interrupt Circuit) device is not required by ETL. A GFCI may be installed if required by local codes but will nuisance trip during use of the product.
  • CAUTION: Loose wire connections can cause heat damage to wires, terminal blocks and other components and may void the warranty.

Remove the screws from the left and right sides of the electrical box. Remove the painted trim piece from the front of the box. Route the feed wires through the holes provided in the bottom of the heater and connect the wires to the terminal block. To determine the correct wire size, refer to Diagram 2. Use copper supply wire only, suitable for minimum 90 degrees C. The heater must be grounded! See Diagram 6 for proper connections.

SECTION 5: TEMPERATURE SENSOR

Feed the “low voltage” sensor wire from the sensor to the sauna heater location. Sensor wire must be routed completely separate (as per low voltage electrical wiring codes) from any wiring carrying over 50 volts. It may be necessary to drill holes to string the wire through the studs or ceiling joists. Route the wire to bottom of the heater and connect to the sensor connection. Mount sensor to finished wall 3″ from the ceiling directly above the heater using two (2) screws (provided) as shown in diagrams 1, 3 & 5.

If mounting heater in the middle of your sauna room, locate the temperature sensor on the ceiling above the heater at a point directly above one outer edge of the sauna heater shroud. See Diagram 1.

WARNING

Fire sprinkler systems used inside any sauna room should be properly rated for sauna room temperatures.

Do not place head and or arms over the BWT when hot. Steam from BWT may cause severe burns.

Do not pour chlorinated pool or spa water on heater or in the BWT.

Excessive water use on heater may cause damage and void warranty.

Electric Shock Hazard – High voltage exists within this equipment. There are no user serviceable parts in this equipment. All installation and service to this equipment should be performed by qualified licensed personnel in accordance with local and national codes.

Do not construct sauna room s0 as to restrict air flow through the bottom of the heater.

Packing the rocks too tightly may cause the heater high limit switch to trip.

DIAGRAM 3

All wiring for sauna system or accessories should be routed inside the walls or away from the high temperature air from the sauna heater.

Controls CAN NOT be installed above the sauna heater inside the room.
INSTALLATION AND OPERATING INSTRUCTIONS

DIAGRAM 4

Bracket fits in any hexagon opening and then screws to the wall or bench.

DIAGRAM 5

Insert screwdriver tip here to unsnap Sensor cover from sensor. Note vertical orientation of cover before removing.

DIAGRAM 5, continued

3″ from ceiling to En‘ top of sensor and centered above Q0 N the heater

DIAGRAM 6
INSTALLATION AND OPERATING INSTRUCTIONS

SECTION 6: HEATER GUARD RAIL

Install a wooden heater guard to prevent the sauna bather from accidentally touching the sauna heater. Install the heater guard rail with the dimensions shown in Diagram 1.

SECTION 7: CONTROL INSTALLATION & OPERATION

INSTALLATION ROUGH IN: Place the control inside or outside the sauna room. If the control is installed inside a sauna room, the top of the unit cannot be higher than 32 inches above floor and 24 inches from the side or front of the heater. Maximum control cable length is 50 feet.

String the provided low voltage control cable through 1” holes in the wall studs or ceiling joists from the control location to the heater. Do not use staples to secure the low voltage cable, it may damage the cable!

Plug the control cable into the control and TEST the control BEFORE mounting!!

After testing is complete, CLEAN the mounting surface to ensure it is free from dust. Remove the adhesive tape from the back of the control, push any excess cable into wall cavity and press the control to the mounting surface.
INSTALLATION AND OPERATING INSTRUCTIONS

  • A. On/Off Light switch
  • B. Indicators – lights for lighting, door switch (n/a), timer and the heater
  • C. On/Off Sauna Switch and fault alarms
  • D. Sets the desired value
  • E. Functions – Temperature, Delay Timer, Sauna Length and Humidity (n/a)
  • Function buttons
  • G. Temperature Display – Current Temperature

CONTROL OPERATION:

TURN ON LIGHT: Press the “light” icon once to turn on the light and press again to turn off. (Usage of light control is optional)

TEMPERATURE: Select the sauna temperature function by pressing the buttons < or > (F) to indicate under the “thermometer”. Next press the — and + buttons to choose the desired temperature 1-10. (Setting 10 equals highest set point.)

SAUNA LENGTH: Select the sauna length function by pressing the buttons < > (F) to the “hour glass”. Set the desired usage time using the — and + buttons.

Chart below indicates the LED meanings. 24 operation is only an option in commercial applications with attendants on duty.

WARNING

Do not locate benches over heater. Refer to Diagram 1 for minimum clearance of ceiling above heater is required.

Minimum clearance from heater to wooden surfaces (benches, side walls, heater fence etc.) is required. Refer to Diagram 1 for specific information.

Mounting brackets supplied. Provides proper clearance from wall behind heater.

Use only copper wire of the size and type indicated in the Heater Specification Chart and the temperature rating indicated on the heater junction box.

All heaters and controls must be grounded per NEC to prevent electrical shock in case of unit failure.

Electrical outlets or receptacle must not be installed in a sauna room.

A guardrail or fence is required around the heater to prevent burns from accidental contact.

When the desired temperature and time has been set and the heater is switched “On” the set temperature indicator light will remain on and the current temperature indicator LED will flash. When the current temperature reaches the set value the indicator light will stop flashing.

SECTION 7: OPERATION, Continued

FAHRENHEIT or CELSIUS: The temperature will be displayed in Fahrenheit as default. To change the temperature display, apply power to the system for over 5 minutes and the LED temperature indicator must be glowing. Next, press the < button for 5 seconds. After 2 seconds the temperature indicator will start flashing, and a C or F will appear in the temperature display to indicate that the temperature display has been changed.

START HEAT IMMEDIATELY:
Start the heater on by pressing the On/Off button. The latest temperature and usage time settings will remain preset. A green indicator light will come on in area (B) to indicate that the device has been switched on.

You may switch the system off before the usage time ends by pressing the same button again. The indicator light will go out.

TIME DELAY START TIME: The heater or the steam generator may be preset to switch on after a certain amount of time. Select the clock symbol using the function button (F). Use the —and + buttons to select the amount of hours (1-10 hours) after which the device will switch on. Activate a later start by pressing the Start button (C).

The timer symbol light will come on (in field B) and the selected time-lapse indicator light will start flashing. The flashing indicator measures and indicates the time leading up to the device being switched on. When the heater starts, the control panel will automatically show the set temperature.

SECTION 8: HIGH LIMIT CONTROL (RESET BUTTON)

The sauna heater has a built-in high limit control, which automatically turns off the heater if the temperature inside in the sauna room rises to an abnormally high level.

To restart the heater, let the heater cool, then push the reset button on the bottom of the heater, see Diagram 1. If the high limit continually shuts off the heater, contact a service representative. Refer to Troubleshooting Section for information.

SECTION 9: HOW TO TAKE A SAUNA

  • When taking a sauna, allow time to relax completely.
  • Remove clothing and jewelry…if required, wear a towel loosely.
  • Some sauna bathers enjoy the soothing effect of steam by splashing water on the heated sauna rocks. Use only one dipper full (approx. ¥z cup) at a time and keep clear of the steam as it rises off the rocks. This heater has a BWT provided and must be installed in the heater.
  • Water in the BWT will add a continuous humidity to the sauna room. Additional water can be poured onto the hot rocks at any time to boost the steam level.
  • Fill tank with approximately 2 cups of fresh tap water when heater is turned on (never use water from a pool or spa!)
  • Heater can operate with BWT tank empty if user does not want constant steam.
  • You may add fragrance oils to the BWT if desired.
  • Do not pour chlorinated pool or spa water on the heater or corrosion damage may result.
  • After 10 minutes or when perspiration begins, leave sauna and relax in dressing area… follow with a cool shower.
  • Cooling time should equal time spent in sauna. Enter sauna room again and stay 5 or 10 minutes.
  • Repeat the cycle 2 or 3 times; end with a brisk shower…rinse in cool water.
  • Dress when completely dry and perspiration has stopped.
  • Do not smoke, exercise or drink alcoholic beverages in the sauna room.

Shower
Shower

Sauna (10 – 15 min.)

Shower or swim

Rest (10 – 15 min.)

Relax with juice or water

You liked it? Do it once again and you will feel great.

DIAGRAM 7

TYPICAL PRE-CUT WALL CONSTRUCTION
INSTALLATION AND OPERATING INSTRUCTIONS

DIAGRAM 8

**HEATER SCREEN (GUARD RAIL)

**

DIAGRAM 9

VENTILATION
OPERATING INSTRUCTIONS

DIAGRAM 10

  1. Put smaller rocks in first around the outer perimeter of the heating elements in layers.
  2. Fill the middle sections with larger rocks.
  3. Ensure the elements are vertical as filling the heater with rocks.
  4. Place rocks loosely in the center of heater to allow heat to rise easily up in the middle of heater.
  5. Be sure rocks completely cover the elements.
  6. Loosely cover the tops of all elements with rocks.
  7. Place heater grill on heater.
    OPERATING INSTRUCTIONS

DIAGRAM 11

BWT tank hangs on the top of the heating elements.
BWT tank

BWT tank, tank lid, and the vent cover installed and the rocks placed around the tank.

SECTION 10: WARNING PLACARDS

Three metal placards are included in the Installation Instruction Envelope packaged with every Sauna Heater. The CAUTION placard must be attached to the interior wall of the sauna room directly above the heater where it is visible to the bather. The French and English WARNING placards must be attached to the door of the sauna room.

SECTION 11: ROOM CONSTRUCTION

  • For safety and reliability, the following rules must be addressed.
  • No permanent locking or latch system is to be used on the sauna door.
  • Acceptable door fittings are: magnetic catches, friction catches, spring or gravity loaded closures. The door must always open outwards. No shower may be installed in a sauna room. No electrical receptacle shall be installed inside the sauna room. The enclosed WARNING: Reduce the risk of overheating … warning plate must be mounted on or alongside the door outside the sauna room at about eye level.
  • The enclosed CAUTION: Reduce the risk of fire … caution plate must be mounted on the interior wall above the heater.
  • The heater should not be operated without its container properly filled with rocks and the rock guard in place.
  • If an intercom speaker is installed, it should be away from the heater and as close to the floor as possible.
  • Fire sprinkler systems installed inside any sauna room should be properly rated for sauna room temperatures.
  • Always mount the heater according to these installation instructions.
  • Minimum of R12 insulation in 16” on center 2×4 stud walls.
  • Recommended minimum flooring thickness of 5/8”

WARNING

The “CAUTION” and “WARNING” placards must be mounted in accordance with Section 10.

WARNING

REDUCE THE RISK OF OVERHEATING

  • it immediately if uncomic table, dizzy, or sleepy. Staying 0o long ina sauna is capable of causing overeating.
  • Supervise chidden al ll ices * Check with a doctor before use if pregnant, in poor health, or under medical care
  • Breathing heated air in conjunction wih consumption of alcohol, drugs, or mediation is cashable of causing Unconsciousness,

SECTION 12: VENTILATION

VENTILATION In a sauna, the air should be changed about 6 times an hour. This can be achieved by making a vent opening (fresh air inlet) in the sauna wall directly below the heater. The air outlet must be lower than the upper benches, as far as possible from the heater and about two feet higher than the fresh air inlet vent, See Diagram 9. It is recommended that ventilation openings meet the requirements of UL Specification 875. The minimum opening should be determined using one of the following formulas:
For R<31, V=93, For R>31, V=03R
where R = the floor area of the room in square feet and V = the minimum vent size in square inches

SECTION 13: BWT (Bio Water Technique) Technology

The world sauna trend is moving to the higher humidity and lower temperatures. Many find it easier to breathe, the skin feels warm, and the humidity helps induce a sweat. This system will increase the humidity in the room allowing the air temperature to be lower, and still feel hot.

BWT technology provides the ability to increase humidity levels in the sauna room while the heater is warming up and during the sauna session. The continuous soft boil of water during the sauna session increases the humidity in the room to provide a consistent feel. Additional water can be added to the rocks to provide an additional spike of humidity as needed.

How to use BWT: Allow heater to warm up for approximately 20 minutes and add water into the tank through the side of fragrance diffuser with slots. Add approximately 2 cups of fresh water into the tank. Do Not Use Pool or Spa Water.

Fragrance oils can be placed in the side of the fragrance diffuser without the slots. Avoid adding fragrances directly into the water of the BWT. The oils may cause the water to foam and maybe difficult to remove the scent from the tank.

BWT tank and sleeve should always be installed in heater with rocks. Water in the tank is optional and not required if preference is lower humidity.

SECTION 14: MAINTENANCE

Inspect sauna room at the end of each day the room to ensure the control and system is off. The sauna, like a bathroom, should be kept clean and odor free. Towels or mats should always be used on benches and floor as perspiration otherwise penetrates the soft wood.

Air out the sauna often by keeping the door and vents open when the sauna is not in use. Saunas that are in daily use should be washed down at least once a week to keep them clean and the air fresh. Duckboard should be removed from the sauna, the sauna floor mopped and dried in a conventional manner, and the duckboard thoroughly scrubbed and dried before returning to the sauna room. The sauna heater should be wiped down occasionally with a damp cloth to remove lint and dust. The rocks should be removed once a year for cleaning and small or crumbled rocks replaced.

To clean and remove perspiration stains, use soap or detergent in warm water, best applied with a scrub brush. Badly soiled surfaces may require sanding. Sand paper wrapped around a wooden block works well.

Benches and supporting structure must be inspected annually for potential deterioration due to age, dry rot or abuse. Any boards with signs of deteriorations should be replaced immediately to avoid possible injury.

BWT will accumulate hard-water scale inside the tank as the water is evaporated over time. The water scale will not immediately affect performance. It is recommended to remove the tank from the heater and clean it when you notice a heavy accumulation or when the rocks are changed. Simply tap on the sides of the tank to loosen the scale and then dump into a – waste basket. If stubborn scale accumulation remains, you may use any commercially available de-scaling product to remove built-up hard water scale. Follow up with a fresh water rinse before putting BWT back into the heater.

DIAGRAM 12: ROOM TEMPERATURES

Non-Typical Ceiling Height

Notes:
Temperatures vary in a sauna room by height and distance from heater.

ventilation will help reduce it but will not eliminate temperature variations.

The hottest part of the room is always at the ceiling directly above the sauna 125°F heater and should not exceed 194°

Air temperature will be 15°F to 25°F lower on the opposite side of the room

The temperatures in the elevated view are general numbers. Each sauna room is different due to construction variations and ventilation.

**Typical Ceiling Height

**

SECTION 15: REPLACEMENT PARTS

1 8019-517 GUARD,ROCK,HIMALAYA,BLK,SK-ZG 1
2 8221-06 HOLDER,BWT,FRAG CUP,BLACK 1
3 2137-23 COVER,BWT TANK,W/FRAGRANCE HOLDER,HIMALAYA 1
4 N/A Item 4 is combined with Item 3 N/A
5 8100-483 TANK, WATER,BWT,( MF),HI MALAYA HTRS 1
6 3001-768 ELEMENT, HTR,2267W,208V,SEPC 226-1, HI MALAYA 3
6 3001-769 ELEMENT, HTR,2267W,240V,SEPC 226-1, HI MALAYA 3
6 3001-770 ELEMENT, HTR,3000W,208V,SEPC 238-1, HI MALAYA 3
6 3001-771 ELEMENT, HTR,3000W,240V,SEPC 238-1, HI MALAYA 3
7 8250-086 BRKT,HTR,HIMALAYA,70/90,MOUNTING 1
8 8201-115 BRKT,HOLDER,HIGH LIMIT,HIMALAYA HTR 1
9 8012-527 SHROUD,HTR,HIMALAYA,BLK,OUTER 1
10 3119-510 SWITCH,HIGH LI MIT,55.31529.960 1
11 2100-552 TERMINAL,BLOCK,4-POS,WHT 1
12 5304-019 CABLE,ASSY,FLAT,12″,4-COND,RJ10/22 CONNECTORS 1
13 3100-593 FUSE,CIRBRKR,SC,2 AMP,T13-211-2A 1
14 2100-550 TERMINAL,BLOCK,6POS,SPADE,W/3JUMPERS,NLWB,1-1 1
15 8093-001 ENCL,ELECTRICAL CHASSIS,HIMALAYA 1
16 3229-005 PCA,SAUNA,RELAY CARD,240V,LOWIPAL 1
17 3131-517 CONTACTOR,OKTA 5-1,LC7K09004M7 1
18 8026-020 STAN D,ADJ.FEET,H1 MALAYA 1
19 8201-039 BRKT,PCA HIGH MNT,SST,VERT,(Himalaya) (Not Shown) 1
20 8012-477 COVER,ELECTRICAL ACCESS,HIMALAYA (Not Shown) 1

SECTION 15: TROUBLESHOOTING

Control will Run but No Heat – Press the (reset) high limit switch on the bottom of heater.

No Heat – Ensure control in not in delay mode (Hour Glass LED glowing)

Slow Heat Time or High Limit Tripping – Check rock placement, they will break down over time and reduce the air flow in the heater. Refer to Diagram 10 for proper rock installation. Discard all rocks under the size of 2″ pieces. Call the number below to order more rocks if needed.

CAUTION: Use only a contactor approved for 250,000 endurance Cylces / ATTENTION: Utiliser uniquement un contacteur approuve pour 250,000 cycles de fonctionnement

In the event of a fault occurring in the heater system (control panel, temperature sensor, etc.), this will be signaled by the LED indicator light on the control panel. The fault indicator light will be displayed on the 1-10 scale of the control. The fault error code will be displayed with a constant LED light or a flashing LED light. See the list below for fault codes.

Note: The LED indicators do not turn off, some indicators will glow as long as power is applied to system.

stant LED Fault Code (ones marked with “n/a” are not in use):

  1. Temperature sensor not connected or shorted
  2. nja
  3. Heater circuit board overheated
  4. n/a
  5. nfa
  6. Communication lost between control and circuit board in heater.
  7. nja |%| ¢ 0ojo
  8. n/a
  9. n/a
  10. n/a

Flashing LED Fault Code

  1. nfa
  2. na
  3. nja
  4. nfa =
  5. nfa
  6. n/a
  7. n/a
  8. n/a
  9. Door Switch is open for more than 60 seconds while heating or jumper on circuit board in heater is removed.
  10. Door Switch is open for more than 60 seconds in “Delay” Mode or jumper on circuit board in heater is removedConstant LED Fault Code

For troubleshooting or service questions call 1-888-780-4427 and ask to speak with service. Prior to calling, please have the Model and Type number available. You may also email us at techsupport@tyloheloinc.co

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals