dicio P17 Blue Winged Wire Connectors
To be sold only with installation instructions.
Qty 50 pcs.
INSTRUCTION
- Turn off power before installing or removing connectors.
- Strip wires to a length of 7/8″ (22.2 mm).
- Pre-twisting is unnecessary. Hold stripped wires together with ends even. Slightly lead stranded wires.
- Align any frayed strands or conductors.
- Push wires into the connector and screw on until two twists are visible in the wires.
Copper-To-Copper
For use with copper-to-copper conductors only
- Temperature Rating: 105°C (221°F) max.
- Voltage Rating: 600V max. for building wiring, and 1000V max in fixtures/luminaires and signs.
Listed as a PRESSURE-TYPE wire connector on the following Solid and/or Stranded wire combinations:
Certified
For UL Listed and CQC Certified
- 4#10
- 1#10w/3#12
- 2#10w/1#12
- 2#10w/2#12
- 2#10w/3#12
- 3#10w/1#12
- 3#10w/2#12
- 1#8w/3#10
For CSA and CQC Certified:
- 10r2#6
- 10r2#8w/1to4#14
- 20r3#8
- 3#8w/1#12or#14
- 2to4#10
- 1#10w/2or3#12
- 1#8w/1to3#10
- 2#10w/1to3#14
- lor2#8w/1to3#12
- 3#10w/1#12
- 3#10Solw/2#12Sol
- 3#10 Solw/2 #12 Str
- 3#10 Str w/2 #12 Str