WINIX C545 4-Stage Air Purifier User Guide

June 6, 2024
WINIX

AIR PURIFIER

C545 USER MANUAL

MODEL PART DIAGRAM

PACKAGE CONTENTS

  • For a Certified Refurbished Air Purifier, there will be 4 New Carbon Filters and 1 True HEPA Filter included; equivalent to a 1-year supply.

WHERE TO USE

Allow 12 ~ 18 in. of space between TVs, radios, and other electronics. Electromagnetic interference from certain electronics may cause product malfunction.
Place indoors away from direct sunlight. Direct exposure may cause product malfunction or failure.
Only place on hard, flat surfaces. Flimsy or slanted surfaces may result in abnormal noise and vibrations.
Allow at least 12 ~ 18 in. from walls for maximum air flow

4-STAGE AIR PURIFICATION
Air Purification means it removes inanimate particles

1 Pre-Filter
2 Activated Carbon Filter|  3 True HEPA Filter
4 PlasmaWave®
---|---

CONTROL PANEL

  1. Auto Mode Indicator – The LED “Auto” light will indicate when Auto Mode is activated.

  2. Air Quality Indicator – Color coded LED light indicates one of three levels of Air Quality: Red (poor), Amber (fair), and Blue (good).

  3. Fan Speed Indicator – Indicates the current fan speed.

  4. Sleep Mode Indicator – The LED “Sleep” light will indicate when Sleep Mode is on.

  5. Filter Replacement Indicator – LED light indicates when it is time to change the filter.

  6. Filter Reset Button – After replacing the True HEPA Filter, use a small object such as a paper clip, to press and hold the Filter Reset Button for at least 5 seconds until the Filter Replacement Indicator turns off.

  7. Smart Sensor – Detects the amount of odorous gas in the environment. When in Auto mode, the fan speed adjusts according to the detected amount of gas.

  8. Power Button – Turns the unit on or off. During the first 30 seconds of powering up, the Air Quality Indicator will cycle through Blue, Amber, and Red colors.
    • Smart sensor takes approximately 4 minutes to detect the air quality in the environment before normal operation begins.

  9. 1. Fan Speed/Auto/Sleep Buttons – Use the Fan Speed arrow buttons to set the desired fan speed. Fan Speeds cycle over in this sequence: Auto, Low, Medium, High, Turbo, Sleep, Auto.
    Auto Mode: Automatically adjusts fan speeds according to your indoor air quality. The fan speed will adjust to low when air quality is good, medium when fair, and to high when poor.
    Sleep Mode: When Sleep Mode is activated, the Air Quality Indicator LED light is disabled.
    • Fan speed will automatically set to minimum speed (lower than ‘Low’) which will be nearly silent. When Sleep Mode is active, PlasmaWave® will be disabled, but it can be turned back on.
    9-2. PlasmaWave® Button – Press and hold the buttons for 3 seconds Press the Plasmawave® button when the unit is on to enable or disable this feature. By default, PlasmaWave® is enabled whenever the unit is powered on. When the unit is running, you may hear a chirping or buzzing sound. The sound is from large particles passing through PlasmaWave®, it is normal and does not signify product failure.

  10. PlasmaWave® Indicator – Indicates whether PlasmaWave® is enabled or disabled.

  11. Wi-Fi Button – Press for 3 seconds to activate pairing mode. When Wi-Fi is paired, press the button to turn Wi-Fi off or back on.

  12. Wi-Fi Indicator – Enables or disables the WiFi feature. When in the pairing state, the Wi-Fi LED flashes. When paired successfully, the Wi-Fi LED will be a solid white light.

  13. Light Sensor – Detects the amount of ambient light in the environment. When in Auto Mode, the light sensor detects when to put the unit into Sleep Mode.
    Winix Smart Wi-Fi Setup – Refer to the Wi-Fi Guide Guide provided inside the box.

INITIAL OPERATION

  1. Remove the front panel by grasping its upper edge and gently pulling forward.

  2. Remove the Pre-Filter, then the bag of filters behind it.

  3. Remove filters from protective plastic bag.

  4. Install the filters until they fit securely in place.
    03. True HEPA Filter (back)
    02. Activated Carbon Filter (middle)
    01. Pre-Filter (front)

  5. After filters are installed, close the front panel.

  6. Insert the power cord into an electrical outlet.

MAINTENANCE

When to Replace Filters

Filter Indicator Light When to Service When to Replace
Pre-Filter none Every 14 days Permanent
Activated Carbon Filter none CAN’T BE WASHED Every 3 months
True HEPA Filter Check Filter Lasts Approx. 12 months
  1. When the Check Filter Indicator LED is on, it is time to replace the Filter.
  2. Intervals between filter replacement may vary depending on environment.

REPLACING FILTERS

Resetting Filter Life:

****After replacing your True HEPA Filter, place the Pre-Filter back in and close the Front Panel. While the unit is on, hold the Filter Reset Button for at least 5 seconds until you hear the beep. After the beep, the Filter Replacement Indicator will disappear. The True HEPA Filter is now reset.

CLEANING CARE

Cleaning the Filters:

Use a vacuum cleaner or soft brush to clean the Pre-Filter.

  • If it is excessively soiled, rinse in room temperature water. Do not use detergent or soap. Allow the filter to dry for 24 hours or more before using. Intervals between filter cleaning may vary depending on the air quality. Do not use hot water over 104oF or volatile fluids such as paint thinner.

NOTICE

  • When cleaning the unit, always unplug the power cord first and then wait until the unit has cooled down.
  • Never disassemble, repair, or modify this unit yourself.
  • Do not use flammable sprays or liquid detergents.
  • Do not allow children to clean or maintain the unit.
  • Before cleaning or maintaining, ensure unit is unplugged.
  • Do not use benzene, alcohol, or other volatile fluids, which may cause damage or discoloration.

Cleaning the Exterior & Interior:

Wipe with a soft damp cloth using room temperature water.

  • Afterwards, wipe it down with a dry cloth.
    Open the front panel and clean the interior with a vacuum cleaner.

  • For optimal performance, clean every 1 – 2 months.

SPECIFICATIONS

Model C545
Voltage AC 120 V / 60 Hz
Power Rate 65 W
Dimensions 13.7″W × 8.4″D × 20.5″H
Weight 11 lbs
Filter SKU Filter S: 1712-0096-00

Contact Winix for product related inquiries and customer service

To expedite service, please specify the model name and number, the nature of the problem, your contact information, and your address. For Troubleshooting or Frequently Asked Questions, please visit: https://winixamerica.com/faq/

SAFETY AND CAUTIONS

Before operating this equipment, carefully read and follow these safety cautions.

Ensure filters are inserted before running unit.
Running the unit without filters can shorten the lifespan of the unit and cause electric shock or injury.
Be sure foreign objects are NOT inserted into the vents on the unit. Objects can include pins, rods, and coins.
Do not touch any part of the interior of the unit with wet hands. The high voltage may cause electric shock.
Ensure unit intake and outlet vents do not become blocked. Blockage may lead to increased internal termperatures, causing product failure and deformation.
Do not use the unit as a step stool or place heavy objects on the unit. Personal injury may occur or product failure and deformation.

WARNING
Follow these instructions to reduce the risk of serious injury or death and to reduce risk of damaging the unit.

  • If the power cord is damaged, it must be replaced by a special cord. Reassembly is available from the manufacturer or its service agent.
  • This appliance is not intended for use by a person (including children) with reduced physical sensory or mental capabilities, or lack of experience and knowledge of the unit, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.
  • This unit is not intended to be used to preserve documents or art conservation.

Do not place below any electrical outlet.
Do not have the unit facing into wind or drafts.
Do not pull on the power cord when unplugging the unit.
Do not tie or knot the power cord when unit is in operation.
If the unit becomes submerged in water, unplug it and contact customer service.
Do not unplug or move the unit while in operation.
Do not plug additional appliances into the same outlet or power supply.
Do not touch the plug with wet hands.
Unplug the unit when not in operation for extended periods of time.
Do not place around heating elements.
The cord can become damaged by forcefully bending, pulling, twisting, bundling, pinching or placing heavy objects on it.
Do not install in any sort of motor or transport vehicle (trucks, boats, ships, etc.).
Do not place in an area with excessive amounts of noxious gases.
Do not place near any flammable materials (aerosols, fuel, gases, etc.).
Do not place in excessively humid areas where the unit may become wet.
Do not place unit closer than 12 inches from the wall during operation. It may cause condensation on the wall and the surrounding area.
**** Do not use around mist or fumes from industrial oil or around large quantities of metallic dust.

SAFETY INSTRUCTIONS

Thank you for purchasing a Winix air purifier. This product is for household use only.
IMPORTANT CAUTIONS FOR USING YOUR AIR PURIFIER:

WARNING:
Follow the instructions in this manual to reduce the risk of electric shock, short circuit, and/or fire.

  • Do not repair or modify the unit. All repairs should be completed by a qualified technician.
  • The plug for this unit is polarized with one blade wider than the other. Do not force the plug into an electrical outlet. Do not alter the plug in any way. If the plug does not fit into the outlet, reverse the plug. If it still does not fit, contact a qualified technician to install a proper outlet.
  • Do not use if the power cord or plug is damaged or the connection to the wall outlet is loose.
  • Use AC 120V only.
  • Do not damage, break, forcefully bend, pull, twist, bundle, coat, pinch, or place heavy objects on the power cord.
  • Periodically remove dust from the power plug. This will reduce the risk of shock due to humidity build up.
  • Remove the power plug from the outlet before cleaning the unit. When removing the power  plug, grasp by holding the plug itself, never hold by the cord.
  • If the power plug is damaged, it must be replaced by the manufacturer or a qualified technician.
  • Remove the power plug from the outlet when not in use.
  • Do not handle the power plug with wet hands.
  • Do not operate the unit when using indoor smoke-generating insecticides.
  • Do not clean unit with benzene or paint thinner. Do not spray insecticides on the unit.
  • Do not use the unit where it is humid or where the unit may become wet, such as the bathroom.
  • Do not insert fingers or foreign objects into air intake or outlet.
  • Do not use the unit near flammable gases. Do not use near cigarettes, incense, or other sparkcreating items.
  • Unit will not remove carbon monoxide emitted from heating appliances or other sources.
  • Unplugging the product disconnects the remote functions.

IMPORTANT PRECAUTIONS FOR USING YOUR AIR PURIFIER:

  • Do not block the intake or outlet vents.
  • Do not use near hot objects, such as a stove.
  • Do not use where the unit may come into contact with steam.
  • Do not use the unit on its side.
  • Keep away from products that generate oily residue, such as a deep fryer.
  • Do not use detergent to clean the unit.
  • Do not operate without a filter.
  • Do not wash and reuse the True HEPA Filter.
  • Hold the handle on the back of the unit to transport.
  • Do not hold by the front panel.
  • Do not stick any small objects into the air outlet vents or fan.

TWO YEAR WARRANTY

For more warranty information visit: https://winixamerica.com/terms-and- conditions/

The terms of the warranty are as follows:

  1. This product is manufactured under stringent quality control and inspections.
  2. The warranty will be voided if product failure is a result of negligence or misuse by the consumer.
  3. A proof of purchase must be presented upon claiming a Product Warranty.
  4. Store the proof of purchase in a safe place or register your product on winixamerica.com to upload your proof of purchase.
  5. This warranty is valid only in the USA and Canada.
  • Certified Refurbished Air Purifiers come with a 1-year warranty. All Winix Certified Refurbished Air Purifiers go through a detailed inspection and refurbishment process to ensure all quality and performance standards are met.

Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation,
Science and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions:

  • This device may not cause interference.
  • This device must accept any interference, including interference that may cause undesired operation of the device.


The energy efficiency of this ENERGY STAR certified model is measured based on a ratio between the model’s CADR for smoke and the electrical energy it consumes, or CADR/Watt.

  • The product warranty is printed on the back of this guide This product is manufactured for use only in USA / CA. This product is suitable for 120 V only.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals