230 V AC Sanela Toilet Flush Control Installation Guide
- September 12, 2024
- SANELA
Table of Contents
230 V AC Sanela Toilet Flush Control
“`html
Specifications
- Power Supply: External
- Location: Control
- Stainless Steel Cover
- Mounting Box
- Operating Voltage: 24V
- Active Range Flush Cycles
- Recommended Pressure Rate of Flow
- Water Inlet Water Outlet
- Warranty: Included
- Product Code: Available
Product Usage Instructions
External Power Supply Installation
Ensure mains power supply is off.
Position mounting box 500mm from the floor considering moisture
ingress and maintenance.
Follow NZ electrical regulations for installation.
Installation Steps
-
Align piping with water inlet/outlet.
-
Insert mounting box and connect power supply from
transformer. -
Securely connect pipework and electronics to solenoid
valve. -
Connect power supply to electronics following correct
polarity. -
Reinstall stainless steel cover securely.
FAQ
Q: Can the Sanela Toilet Flush Control be manually
operated?
A: Yes, there is an optional manual flush operation
available.
Q: What is the warranty period for the product?
A: The product includes a warranty, please refer to the
documentation for specific details.
Q: What is the operating voltage of the sensor?
A: The operating voltage of the sensor is 24V.
“`
TOILET FLUSH
Installation & maintenance instructions.
General Information
· Designed for indoor use only. Do not expose to elements of nature.
· All plumbing and electrical connection must be made in accordance with
AS/NZ3500 and installation with AS/NZ3500.2.
Warnings
· Read all instructions before attempting to install this system. It is
recommended a qualified & registered plumber completes the install.
· Ensure pipe work is thoroughly flushed before installing the flush control
(internal solenoid). Solenoid components are susceptible to debris and require
additional flushing compared to a standard plumbing fixture.
· Consideration should be given to any regulations relating to an air gap, an
air break or double check valve to protect against back flow.
splwashrooms.co.nz
2
Operating Instructions and Parts Manual
Please read carefully before attempting to assemble, install, operate or
maintain the product described. Protect yourself and others by observing all
safety information. Failure to comply with instructions could result in
personal injury and/ or property damage. Retain instructions for future
reference.
Sanela Toilet Flush Control
Sensor operated flush control for single toilet. Non touch infrared system
detects and responds to movement and flushes only after user has left active
range. High quality electronics combined with elegant aesthetics.
Specifications
Power Supply Location Control Stainless Steel Cover Mounting Box Operating
Voltage Active Range
Flush Cycles
Recommended Pressure Rate of Flow Water Inlet Water Outlet Warranty Product
Code
Mains – 230V AC, 50Hz (input) – 24V DC (output) Wall mounted above the toilet Infra-red sensor 170 x 170 x 10mm 145 x 155 x 100mm 24V DC, 7W 0.6- 0.75m – system reacts to user attendance in active range (0.7m) for min stay time of 7.5 – 7.75secs Short Flush: (2s) min stay 7.75 secs, max 45secs Long Flush: (5s) min stay 45 secs (adjustable 0.5 – 15.5 secs) Manual Push Flush: (cleaning) Hygiene Flush: 24hrs after last use 0.15 – 0.6 Mpa (1.5-6 Bar) 70 L/min @ 0.15MPa (inf. Data) Ø min 32mm (PN 16) male thread G 1 Male thread G 1″ 24 months STI01AC
Planning
· Ensure an appropriate piping design (sizing etc). This will eliminate issues
arising from flow, pressure and water hammering.
· Where appropriate install necessary filters, water hammering arrestors and
water pressure reducing valves (recommended pressure 1 to 6 bar). This will
minimise future maintenance.
· Install isolation valve to enable ease of future maintenance.
splwashrooms.co.nz
3
Components Standard Functions
1
Stainless steel cover
2
Mounting box cover
3
Screw (x2)
4
Screw (x4)
5
Allen key
6
Mounting box
Person stays within Water flows after
active range for min person leaves
stay of 7.5secs
active range
Hygiene flush automatically
every 24 hours
Optional manual flush operation
Operating pressure range
splwashrooms.co.nz
4
External Power Supply Installation
Input Output IP rating Operating temperature Rated power
230V / 50 Hz 24 V DC IP 55 5°C – 40°C
10W
Important
230V input
24V output (to sensor)
To be installed in accordance with all NZ electrical regulations. It must be carried out by a qualified professional.
Positioning of the mounting box should be 500mm from the floor and consider:
- Moisture ingress due to plumbing fault
2. Ongoing maintenance and accessibility
The mounting box can be surface mounted or within the service or ceiling cavity.
Ensure mains power supply is off
Mark mounting point(s) on surface
splwashrooms.co.nz
5
Drill and insert appropriate wall anchors if required Remove cover from mounting box
Fix mounting box to wall
Pass mains (230V) power supply into mounting box via grommet and terminate
accordingly
Note: Power supply should be secured via current breaker before the external
supply (not included)
Reinstall cover of mouting box and ensure sealed. Tighten grommet to ensure snug around cables
splwashrooms.co.nz
6
Installation
Ensure mains power supply is off. Align piping arrangement with water inlet/outlet.
Make certain a power supply connection has been allowed for and the correct transformer has been supplied.
Insert mounting box in place. Ensure pipework has been flushed thoroughly.
Pass power supply from transformer into mounting box via grommet. Connect pipework securely.
splwashrooms.co.nz
7
Screw temporary cover in place (if applicable).
Reinstate mounting surface (if applicable).
Remove temporary cover (if applicable).
Using the allen key, remove 2 x security screws from the bottom of stainless steel cover and seperate cover from plate.
Fix plate to mounting box (4 x screws).
splwashrooms.co.nz
Connect electronics to solenoid valve. 8
Connect power supply to electronics, via wago connectors. Note polarity.
Refit stainless steel cover by carefully inserting top mounting points first, followed by tightening of 2 x security screws at the bottom – use allen key.
Turn power supply on. It is necessary, for the proper function, to keep the unit under constant voltage (don´t connect the power supply unit behind the switch into the light circuit)
Once power on, avoid coming within active range for 10 seconds while sensor calibrates.
splwashrooms.co.nz
9
Important
Pipework is required to be flushed thoroughly prior to installation. Foreign
debris may reduce level of flow and in some cases damage the solenoid valve. ·
The sensor of the unit must not be obstructed. · Avoid positioning reflective
objects or surfaces in front of the sensor. This can cause false
activation. · All plumbing and electrical installation must be carried out by
a qualified person and in
accordance with applicable codes and regulations.
Note: If you require to modify any of the factory settings please request the
Sanela remote SLD03.
Maintenance
· It is recommended that the solenoid valve and all filters be inspected for
foreign debris and cleaned annually (more frequently if necessary)
· Clean cover regularly using soapy water and a soft cloth or wet sponge
· DO NOT clean cover with any abrasive material or chlorine/acid based
cleaning product. This may damage the filter of the infrared sensor and/or the
finish.
splwashrooms.co.nz
10
Troubleshooting
Symptom
Possible Cause
Corrective Action
No water flow – a. Water supply
sensor blinked b. Water connections
when within active c. Filter is clogged
range
d. Faulty solenoid
a. Ensure water at source b. Ensure connections c. Clean filter (any valve
and solenoid) d. Replace solenoid
No water flow sensor did not blink when within active range
a. Power supply
a. Ensure power at
b. Power connections to wago source
connectors
b. Check all connections
c. IR sensor damaged or
and polarity
faulty
c. Replace IR sensor
Water doesn’t stop flowing
a. Dirty IR sensor b. Obstruction in detection
zone c. Water drop on sensor eye d. Ghost sensing due to
reflection e. Debris in solenoid
a. Clean IR sensor b. Remove obstruction c. Wipe sensor d. Remove reflective
surface or reposition e. Clean and/or replace
solenoid
Reduced flow rate a. Filter clogged b. Water supply
a. Clean filter b. Check pressure / flow
at source
splwashrooms.co.nz
11
Supreme Comprehensive Warranty
Your Sanela Toilet Flush is fully guaranteed against defective materials and
faulty workmanship commencing from the date of sale (according to SPL’s
records), subject to it being installed and maintained in accordance with the
manufacturer’s instructions.
SPL (2021) Limited warrants that should any part of the fush control fail
within the given warranty period (24 months), it will be remedied by SPL. The
flush control should be returned to SPL (2021) Limited for all warranty
claims. The cost of cartage will be payable by the customer.
Due to the significant variation in tradesmen’s knowledge, experience, and
productivity, labour charges will NOT be accepted unconditionally. We strongly
recommend contacting our office for advice before proceeding with any warranty
repairs.
This warranty excludes:
· Incorrect installation, or installation that does not specifically follow
the installation guidelines supplied
· Defects arising from improper installation, or incorrect electrical supply
where applicable
· Failure to follow manufacturer’s maintenance instructions
· Damage/Failure resulting from: – the use of non-authorised parts –
authorised parts not installed in accordance with the manufacturer’s
instructions – accidental damage, negligent use, misuse, vandalism, neglect –
damage caused either directly or indirectly by external sources (incorrect
power supply, natural disaster, or insect infestation)
· Water ingress caused by property maintenance or flooding
· Negligent cleaning practices (water ingress, harmful chemical etc)
The above includes consequential damage to any other goods, furnishings, or
property.
· Normal wear and tear and consumable parts (batteries etc)
· This warranty does not displace any statutory warranty in relation to the
unit but any liability of SPL (2021) Limited under any statutory warranty will
be limited to a replacement or repair of the unit or payment of the cost of
such replacement or repair at the sole discretion of SPL (2021) Limited
Note: · Warranty only extends to products purchased and installed in New
Zealand. · Contamination or poor water quality is not covered by product
warranty. · Damage to solenoid caused by inadequate flushing or excess water
pressure is not
covered by the product warranty.
SPL Limited Cambridge 3434 New Zealand
p. +64 7 823 5790 e. office@splwashrooms.co.nz
splwashrooms.co.nz
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>