Installation Instructions
High Voltage and ESD Protection Bipolar Hall-Effect Digital Position Sensor IC: SS41F6
GENERAL INFORMATION
CAUTION
ELECTROSTATIC DISCHARGE DAMAGE
Ensure proper ESD precautions are followed when handling this product. Failure
to comply with these instructions may result in product damage.
SOLDERING AND ASSEMBLY
CAUTION
IMPROPER SOLDERING
- Ensure leads are adequately supported during any forming/shearing operation so that they are not stressed inside the plastic case.
- Limit exposure to high temperatures.
Failure to comply with these instructions may result in product damage
Wave solder at 250°C to 260°C [482°F to 500°F] for a maximum of three
seconds. Burrs are allowed only if full lead length will pass through a 0,68
mm [0.027 in] dia. hole.
CLEANING
CAUTION
IMPROPER CLEANING
Do not use pressure wash. High-pressure stream could force contaminants into
the package.
Failure to comply with these instructions may result in product damage.
Use agitated rinse to clean the sensor.
TABLE 1. PERFORMANCE SPECIFICATIONS
(At V S = **4.5 V to ****60 V, T A = -40ºC to ****150ºC [-40ºF to ****302ºF], I O = 15 mA, ****except where otherwise ****specified.)**
Characteristic| Symbol| Condition| Min.| Typ.| Max.| Unit
Supply voltage
|
VS
| —
-40ºC to 125ºC [-40ºF to 257ºF] 150ºC [302ºF]
| 4.5
4.5
4.5
| —
—
—
| 60.0
60.0
24.0
|
V
Supply current| IS| —| —| 3.6| 10.0| mA
Output voltage (ON)| VSAT| IO = 15 mA| —| 0.215| 0.600| V
Output leakage current| IOH| —| —| —| 10.0| mA
Output current limit 1| IO(SCP)| short circuit protection1| 40| —| —| mA
Output switching time: rise time
fall time
|
tr tf
|
TA = 25ºC [77ºF] TA = 25ºC [77ºF]
|
—
—
|
—
—
|
1.5
1.5
|
ms
ESD (Human Body Model)| VESD| per JEDEC JS-001-2014| -16| —| 16| kV
Operating temperature| TA| —| -40 [-40]| —| 150 [302]| ºC [ºF]
Junction temperature| TJ| —| -40 [-40]| —| 165 [329]| ºC [ºF]
Storage temperature| TS| —| -40 [-40]| —| 150 [302]| ºC [ºF]
Thermal resistance| RSJA| —| —| —| 233| ºC/W
Soldering time and tem- perature|
—
|
3 s max.
|
250 [482]
|
—
|
260 [500]
|
ºC [ºF]
1 Output short circuit protection is enabled when the output load current exceeds the rated load current.
NOTICE
These Hall-effect sensor ICs may have an initial output in either the ON or
OFF state if powered up with an applied magnetic field in the differential
zone (applied magnetic field BRP and <BOP). Honeywell recommends allowing 10
µs after supply voltage has reached 4.5 V for the output voltage to stabilize.
NOTICE
The magnetic field strength (Gauss) required to cause the switch to change
state (operate and release) will be as speci-fied in the magnetic
characteristics (see Table 2). To test the switch against the specified
limits, the switch must be placed in a uniform magnetic field.
TABLE 2. MAGNETIC CHARACTERISTICS
(At **V S = ****4.5 ****V ****to ****60 ****V, ****T A ****= ****-40ºC ****to ****150ºC ****[-40ºF ****to ****302ºF], ****except ****where ****otherwise specified.)**
Characteristic| Symbol| Condition| Min.| Typ.|
Max.| Unit
Operate| BOP| —| —| 25| 115| Gauss
TA = 25ºC [75ºF]| —| 25| 65
Release| BRP| —| -115| -25| —| Gauss
TA = 25ºC [75ºF]| -65| -25| —
Differential| BDIF| —| 30| —| —| Gauss
TABLE 3. ABSOLUTE MAXIMUM SPECIFICATIONS
Characteristic| Symbol| Condition| Min.| Typ.|
Max.| Unit
Supply voltage| Vs| —| -0.5| —| 60.0| V
Output voltage| VO| —| -0.5| —| 60.0| V
Output current| IO| —| —| —| N/A1| mA
Magnetic flux| B| —| —| —| no limit| Gauss
1 Output short circuit protection is enabled when the output load current exceeds the rated load current shown in Table 1.
NOTICE
Absolute maximum ratings are the extreme limits the device will momentarily
withstand without damage to the device. Electrical and mechanical
characteristics are not guaranteed if the rated voltage and/or currents are
exceeded, nor will the device neces-sarily operate at absolute maximum ratings
.
Note: Ensure the minimum hole size in the PCB is 0,68 mm [0.027] dia. based on the IPC 2222 Level B standard.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of defective
materials and faulty workmanship during the applicable warranty period.
Honeywell’s standard product warranty applies unless agreed to otherwise by
Honeywell in writing; please refer to your order acknowledgment or consult
your local sales office for specific warranty details. If warranted goods are
returned to Honeywell during the period of coverage, Honeywell will repair or
replace, at its option, without charge those items that Honeywell, in its sole
discretion, finds defective. The foregoing is buyer’s sole remedy and is in
lieu of all other warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no event shall
Honeywell be liable for consequential, special, or indirect damages.
While Honeywell may provide application assistance personally, through our
literature and the Honeywell web site, it is buyer’s sole responsibility to
determine the suitability of the product in the application. Specifications
may change without notice. The information we supply is believed to be
accurate and reliable as of this writing. However, Honeywell assumes no
responsibility for its use.
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop devices or in any other
application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious
injury.
WARNING
MISUSE OF DOCUMENTATION
- The information presented in this product sheet is for reference only. Do not use this document as a product installation guide.
- Complete installation, operation, and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
FOR MORE INFORMATION
Honeywell Sensing and Safety Technologies services its customers through a
worldwide network of sales offices and distributors. For application
assistance, current specifications, pricing or the nearest Authorized
Distributor, visit sps.honeywell.com/ast or
call:
USA/Canada +1 302 613 4491
Latin America +1 305 805 8188
Europe +44 1344 238258
Japan +81 (0) 3-6730-7152
Singapore +65 6355 2828
Greater China +86 4006396841
AMPSEAL 16™ is a trademark of Tyco Electronics Services GMBH.
Honeywell
Sensing and Safety Technologies
830 East Arapaho Road
Richardson, TX 75081
sps.honeywell.com/ast
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>