LUXE K IPL Hair Removal Device User Manual

August 31, 2024
LUXE

LUXE K IPL Hair Removal Device

Product introduction:

The instrument adopts photonic beauty IPL technology, which directly irradiate skin with intense pulse light to produce phot biochemistry.

Functions overview:

  1. Long press the power button: turn the instrument on and off.
  2. Short press the power button: switch gears.
  3. Short press the firing key: stimulate the light. Power interface
  4. Long press the firing button when not touching the skin: turn on the automatic firing mode.
  5. Long press the firing button when touching the skin: equivalent to continuous firing.
  6. Simultaneously press the on-offkey and the firing key: tum the ice cold function on and off.

Product Overview:

Instructions :

  1. Plug the adapter power cord into the power supply

  2. Insert the output end of the adapter into the bottom jack of the epilator.

  3. Standard method:
    Press and hold the “On/Of button” for 3 seconds, the instrument will be turned on, and one indicator light will light up. At this time, the instrument is in the first gear state Weak, 5th gear is the strongest, one gear corresponds to one indicator light. At this time, the instrument is in the single-dick mode, the single-click mode light is on, the light head and the skin are fitted at 90 • and the hair removal can be started by clicking.

  4. How to turn on the cold function:
    Click the power button and the firing button at the same time to turn on the cold function, and the cold indicator light is on. If the cold function is not needed, press the power button and the firing button at the same time to turn off.

  5. Turn on the continuous light output mode:
    When not touching the skin, long press the firing button to turn on the automatic light-emitting mode. Without touching the skin, press and hold the firing button to turn off the automatic light-emitting mode. At this time, the continuous light-emitting indicator is off, and the single-click light is on.

Precautions for use:

Do not block the air outlet during use

How to use ice compress function:
After hair removal, you can 1.L’le the ice compress function alone to cool down. Adjust the instrument to single-dick mode, and then turn on the ice application function to apply ice back and forth against the skin. When the temperature of the lamp head decreases, the ice application effect will be better. (Do not press the firing key at this time).

In order to prolong the service life, please avoid lulling this product in a humid environment. The light needs to be close to the skin before it can work.

Skin test:

Before using first or after tanning, perform a skin test on each treatment area. Skin testing is a necessary step to check the skin’s response to the treatment and to determine the appropriate light intensity for a particular area.

  1. Select an area close to the treatment area.
  2. Turn on the power of the instrument, and select the 1st gear by default.
  3. Place the device against the skin and press the fire button to emit a single flash.
  4. After finishing the skin test, please wait 24 hours to check for any skin defects.

Suitable for skin tone:

Scope of application: lip hair, armpit hair, limbs hair, frontal hairline and other effects of beautiful hair; Painless hair removal is suitable for black hair and dark hair, not for white, gray, golden hair, please refer to the comparison card below.

Skin Tone Hair Comparison Card

Precautions:

  1. People with skin perception disorder cannot use it.
  2. People with allergic dermatitis, eczema and other skin diseases cannot use it.
  3. Pregnant women, women who are menstruating and breastfeeding cannot use it.
  4. Those who have been exposed to sunlight in the past 2 weeks cannot use it.

Instructions for use:

  1. Shave the hair.
  2. Clean your skin and make sure it is completely dry and free of any oily substances. Before lolling the photon depilator, it is forbidden to smear products such as colouring agent and aloe gel. Otherwise there will be no light.

Product parameters:

Product name: IPL photorejuvenation hair removal device
Output:DC
Power: 36Vv
Number o f shots: unlimited
Lighting time: 1-3 seconds
Energy gear: 5 gears
Irradiation area: 3.3cm
Product weight: about 200g
Adapter specification: inputAC100-240V
Working temperature: 5 L -30 ·c
Light source technology: pulsed light

Steps for usage:

  1.  Before use, use cotton swabs or clean cloth dipped in medical alcohol to clean the light outlet and filter . Keep the light outlet dry before use,otherwise the light outlet will be affected.

  2. Plug in the power plug, short press the sv.itch button for 3 seconds to turn on the hair removal mode, the default is 1 gear and in manual mode, the cooling fan rotates.

  3. The power switch key is also the gear key, double-click the “gear key” to select the appropriate gear, the display energy gear, the first gear is the smallest, the fifth gear is the largest, and the gears can be adjusted cyclically.

  4. After the tap position is adjusted, the light outlet of the device is completely attached to the skin part for hair removal. At this time, press the light button to light out when the display screen flashes.

  5. Press the light out button for 3 seconds to enter or exit the manual light out mode, and the screen will light up automatically.
    Open the automatic light output mode:
    In step 5 of the cycle, each skin area that needs to be shed is flashed one time and moved slowly. The shed area is illuminated three times at a time, but not three times in a row in the  same area. And so on to take off the whole hair removal area, and then repeat 2 times.6. After using the hair removal device, selectively apply aloe vera gel (or not).

  6. After using the device, short press the “power switch button” for 3 seconds to shut down, and cut off the power in time. After use, the filter of the lamp head may have small black spots attached, jlLt wipe it with alcohol.

Treatment cycle reference table:

1-4weeks| Use 2-3 times a week| Over 75% of the hair begins to fall out naturally
---|---|---
S-6weeks| 2timesaweek| New hair loss and inhibition of growth
7-8weeks| ltimeaweek| Hair becomes thinner and less, no longer bouncing
8+weeks| 1-2 times a week| Use selectively according to hair growth,\When the hair starts to grow, (use i t again until it stops growing.)

Completion of use:

  1. The skin may be slightly red, swollen or tingly or warm. These reactions are completely harmless and quick disappear.
  2. After using the instrument for 2 hours, you can safely apply lotion, cream deodorant, moisturizing product or cosmetics on the treatment site; If the skin is prickly or red after the treatment, please wait for these conditions to disappear before applying any product on the skin. If the skin feels prickly after applying the product, please wash it off with clean water.

Product maintenance:

  1. Please turn off the power supply of the device immediately after use, remove the plug, and let the instrument cool down.
  2.  Wet a soft cleaning cloth with a little water, and then use it to clean the following parts: filter/skin contact sheet.
  3. Store the instrument in a dry place with a temperature between O ·c-60 t: and no dust.

Troubleshooting:

Problem Description There may be a reason Solution
The device/power adapter becomes warm during use that is normal No action

required
I put the epilator on my skin and the (flash ready) light didn’t come on, but the cooling fan started running.| Device needs to be reset| When the overheat protection is activated, the fan still keeps running, please do not turn off the power of the device, please wait for it to cool down for 15 minutes before continuing to use it.
Unpleasant smell when using the device| Accessories or filters are too dirty| Please clean the accessories carefully.
You have not completely removed the hair in the treatment area which may burn and produce an odor| Please remove the hair on the skin surface before discussing the device.
During the treatment, the skin felt more sensitive and the device felt unbearable pain.| The light intensity setting you are lilting is too high.| Please check it. Make sure you select the appropriate lighting intensity setting and lower it if necessary
You have not completely removed the hair from the treatment area| before lilting this instrument. Please remove the hair on the skin surface first.
The UV filter at the light outlet is damaged.| Once the filter of the effective outer line is damaged. Do not continue to 1.L’le this instrument
Not satisfied with the results of the treatment| The light intensity setting you are using is too low| Please select a higher gear setting
You did not shine a second flash around the previously treated area| Fire the flash as close as possible to the previous part.
This device has no effect on your hair color| If your hair is light blonde, gold or red. These treatments won’t work. Remove all hair successfully. To discuss how you follow the recommended course of treatment, you can program shorter treatment intervals. But it should not be treated more than once a day.
Insufficient frequency of instrument use may slow your response to IPL therapy.| Continue using the device for at least 6 months. Becal.L’le during this time the hair regrows but decreases.

Operation Notes:

  1. Do not look directly at the flash or flash directly to the eyes during operation.
  2. Mild redness of skin after operation is a normal phenomenon, which can be applied with ice or cooled by itself.
  3. When cleaning the dirt on the glass plate inside the outlet, do not spray alcohol directly on the outlet.
  4. During the operation of the instrument, it is not allowed to smear any gelatinol.1.’l cosmetics such as gel on the skin, so as not to damage the instrument.
  5. Try not to eat light-sensitive food (such as spinach, rape, mustard, etc.) during operation.
  6. The adjustment of energy gear is from weak to strong. Under the condition of not damaging the skin, the higher the energy, the better the effect.
  7. Darker skin may experience delayed skin reactions and cannot gain energy because the immediate response is not obvious.
  8. Pay attention to skin moisturizing and sunscreen after flash.
  9. Avoid ultraviolet radiation during use, do a good job of shading protection outside, try to avoid computer radiation, apply isolation cream, sunscreen protective layer.
  10. During use, please do not block the air inlet and heat dissipation hole, so as not to affect heat dissipation.
  11. During the use of the instrument, if there are hairs or stains sticking to the plastic edge of the light outlet, the plastic edge of the light outlet will be black or produce black spots, but it does not affect the performance and normal use of the instrument.
  12. The “light tube” inside the light outlet of the instrument, in the later period of the specified life, the inner wall of the tube will show different degrees of blackening phenomenon, which belongs to the normal aging process of the tube during the life of the energy attenuation rate will not exceed the specified range, can be used normally.
  13. The product does not have waterproof function, please do not use it in the bathroom, in the shower and in other places that maybe easily exposed to water.
  14. If the shell or window of the product is damaged or the instrument is soaked carelessly, please send it back to the manufacturer for maintenance to determine whether it can be repaired before use. Ifit is soaked with electricity, please unplug the power supply to the contactor first to ensure your safety.
  15. Avoid storage in places with strong magnetic field and serious humidity and dl.L’lt or places with high temperature.
  16. Do not strongly impact or hit the instrument.
  17. Use of this product for purposes other than designated functions is prohibited.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals