Megger Lamp Adaptor Kit User Guide
- August 30, 2024
- Megger
Table of Contents
Megger Lamp Adaptor Kit
Specifications
- Product Name: Megger LA-KIT Lamp Adaptor Kit
- Manufacturer: Megger Limited
FAQ
Q: Can I use the lamp adaptors with any type of electrical test equipment?
A: The lamp adaptors are designed to work with electrical test equipment that can be connected via industry standard 4 mm sockets. Ensure compatibility before use.
Q: Is it necessary to follow the safety warnings provided in the user manual?
A: Yes, it is crucial to read and adhere to all safety warnings and instructions to ensure safe operation and prevent any potential risks.
This document is copyright of:
Megger Limited, Archcliffe Road, Dover, Kent CT17 9EN. ENGLAND T +44 (0)1304
502101 F +44 (0)1304 207342 www.megger.com
Megger Ltd reserves the right to alter the specification of its products from
time to time without notice. Although every effort is made to ensure the
accuracy of the information contained within this document it is not warranted
or represented by Megger Ltd. to be a complete and up – to – date description.
For Patent information about this instrument refer to the following web site:
megger.com/patents
This manual supersedes all previous issues of this manual. Please ensure that you are using the most recent issue of this document. Destroy any copies that are of an older issue.
Declaration of Conformity
Hereby, Megger Instruments Limited declares that radio equipment manufactured
by Megger Instruments Limited described in this user guide is in compliance
with Directive 2014/53/EU. Other equipment manufactured by Megger Instruments
Limited described in this user guide is in compliance with Directives
2014/30/EU and 2014/35/EU where they apply.
The full text of Megger Instruments EU declarations of conformity are
available at the following internet address: megger.com/company/about-us/eu-
dofc
Introduction
This instruction manual contains information regarding the correct use and
handling of the Megger LA-KIT Lamp Adaptors. Please ensure to consult the
section “Safety warnings and standards” that contains information regarding
your personal safety when using the product.
Read the ensuing safety regulations attentively before using this device.
Product description
The Megger LA-KIT provides the user with 5 separate lamp socket adaptors, to allow electrical test equipment to be connected to the circuit via industry standard 4 mm sockets, for measurement and test purposes, without the need to disturb the circuit wiring or lamp housing.
Product contents
- B22 Lamp Adaptor
- B14 Lamp adaptor
- E27 Lamp adaptor
- E14 Lamp adaptor
- GU10 Lamp adaptor
- 2 Wire lead set
- Protective carry case
- User guide
Company web site
Occasionally an information bulletin may be issued via the Megger web site.
This may concern new accessories, new usage instructions or a software update.
Please occasionally check on the Megger web site for anything applicable to
your Megger instruments.
www.megger.com
Safety Warnings and Standards
These safety warnings must be read and understood before the instrument is used. Retain for future reference. To ensure safe operation and service of the lamp adaptors, follow these instructions. Failure to observe warnings can result in severe INJURY or DEATH.
Warnings, Cautions and Notes
This user guide follows the internationally recognised definition. These
instructions must be adhered to at all times.
Description
- WARNING: Indicates a potentially dangerous situation which, if ignored, could lead to death, serious injury or health problems.
- ATTENTION: Indicates a dangerous situation which, if ignored, could lead to injuries or health problems.
- CAUTION: Indicates a situation which could lead to damage of the equipment or environment
- NOTE: Indicates important instructions to be followed to perform the relevant process safely and efficiently.
Safety warnings
- The adaptors must be in good order, clean and dry, with no broken or cracked insulation. Verify the integrity of the adaptors and any test leads before use
- The adaptors MUST NOT be used if any part of it is damaged.
- DO NOT use in wet conditions.
- This product is not intrinsically safe. DO NOT use in an explosive atmosphere.
- Take precautions to ensure that terminals will not be short-circuited.
- Connect only suitably rated leads and test equipment to the adaptors..
- These adaptors are to provide measurement connections for test equipment only. They MUST NOT be used as a mains adaptor to provide power for other equipment
- DO NOT use the adaptors for mains load testing.
- DO NOT leave any adaptor connected to the lamp socket when testing is complete.
- The protection provided by the adaptors may be impaired if they are not used in a manner specified by the manufacturer.
- DO NOT dismantle the adaptors – there are no serviceable parts inside. Refer all servicing to Megger.
- Use caution with voltages above 30 Vac rms, 42 Vac peak, or 60 Vdc. These voltages pose a shock hazard.
- DO NOT USE the test leads if they appear damaged or the internal white insulation layer is exposed
ATTENTION: DO NOT USE the test leads in any environment above their maximum category rating
Installation category definitions:
- CAT IV – Measurement category IV: Equipment connected between the origin of the low-voltage mains supply and distribution panel.
- CAT III -Measurement category III: Equipment connected between the distribution panel and electrical outlets.
- CAT II – Measurement category II: Equipment connected between the electrical outlets and user’s equipment.
- Measurement equipment may be safely connected to circuits at the marked rating or lower. The connection rating is that of the lowest rated component in the measurement circuit.
- CAUTION : Phase and neutral (Red and Black) cannot be marked on the B22, B15 and GU10 adaptors due to geometry of these sockets. Phase and neutral can be identified by using a suitable tester.
NOTE : The adaptors must only be used by suitable trained and competent persons
Safety, Hazard and Warning symbols on the instrument
This paragraph details the various safety and hazard icons on the instrument’s
outer case.
Operation
-
Isolate the supply to the circuit to be tested.
-
Remove the lamp from the socket
-
Select the appropriate lamp adaptor and insert into the socket
-
Phase and neutral are only identified on the E27 and E14 adaptors
CAUTION: Phase and neutral (Red and Black) cannot be marked on the B22, B15 and GU10 adaptors due to geometry of these sockets. Phase and neutral can be identified by using a suitable tester. -
Connect the test leads to the test equipment being used BEFORE connecting to the lamp adaptor. Ensure phase and neutral connection is correct on the E27 and E14 adaptors.
-
Re-energise the circuit, if applicable and execute the test. De-energise the circuit once testing is complete.
-
Remove the test leads from the adaptor before the test equipment
-
Remove the adaptor from the socket
-
Replace the lamp
-
Turn the supply back on.
Specifications
Specification | Detail |
---|---|
Voltage range: | 0 V – 253 V AC |
Frequency range: | 50/60 Hz |
Maximum current: | 2 A |
Operating time: | Continuous |
Single adaptor dimensions (Max): | 80 mm x 42 mm x 34 mm |
Single adaptor weight (Max): | 32 g |
Kit dimensions (inc. case): | 190 mm x 100 mm x 75 mm |
Kit weight (inc. case): | 295 g |
Environmental Specification | Detail |
--- | --- |
Operating temperature: | 0°C to 40°C |
Maximum humidity: | 80% R.H. |
Storage temperature: | -20°C to 70°C |
IP Rating: | IP40 |
Maximum altitude: | 2000 m |
Pollution degree: | 2 |
Safety Specification | Detail |
--- | --- |
Safety standards | IEC/EN 61010-1 |
Electromagnetic compatibility standards (EMC) | EN 61326-1:2013 |
Maintenance
Do not attempt to repair the lamp adaptors. They are sealed units and have no user serviceable parts.
Cleaning
- Disconnect the adaptors from any socket and remove all test leads before cleaning.
- Wipe the surface on the adaptors with a damp cloth and mild detergent. DO NOT use abrasives or solvents.
- Ensure the adaptors are dry and free of any moisture before use
Calibration, Repair and Warranty
Megger operate fully traceable calibration and repair facilities to make sure your instrument continues to provide the high standard of performance and workmanship that is expected. These facilities are complemented by a worldwide network of approved repair and calibration companies, which offer excellent in-service care for your Megger products.
3 year warranty.
For service requirements for Megger instruments contact:
Megger Limited
Archcliffe Road Dover Kent CT17 9EN U. K.
Tel: +44 (0) 1304 502 243 Fax: +44 (0) 1304 207 342
OR
Megger
Valley Forge Corporate Centre 2621 Van Buren Avenue Norristown PA 19403 U. S.
A.
Tel: +1 610 676 8579
Fax: +1 610 676 8625
Return procedure
WARNING: Remove the battery cells before shipping.
UK and USA Service Centres
- When an instrument requires recalibration, or in the event of a repair being necessary, a Returns Authorisation (RA) number must first be obtained from one of the addresses shown above. The following information is to be provided to enable the Service Department to prepare in advance for receipt of your instrument and to provide the best possible service to you:
- Model (for example, LA KIT).
- Serial number (found on the display under settings, device information, or on the rear cover and by the batteries or on the calibration certificate).
- Reason for return (for example, calibration required, or repair).
- Details of the fault if the instrument is to be repaired.
- Make a note of the RA number. A returns label can be emailed or faxed to you if required.
- Pack the instrument carefully to prevent damage in transit.
- Before the instrument is sent to Megger, freight paid, make sure that the returns label is attached or that the RA number is clearly marked on the outside of the package and on any correspondence. Copies of the original purchase invoice and packing note should be sent simultaneously by airmail to expedite clearance through customs. In the case of instruments which require repair outside the warranty period, an immediate quotation can be provided when obtaining the RA number.
- Track the progress on line at www.megger.com.
Decommissioning
WEEE Directive
The crossed out wheeled bin symbol placed on Megger products is a reminder not
to dispose of the product at the end of its life with general waste.
Megger is registered in the UK as a Producer of Electrical and Electronic
Equipment. The Registration No is WEE/ HE0146QT.
For further information about disposal of the product consult your local
Megger company or distributor or visit your local Megger website.
Battery disposal
- The crossed out wheeled bin symbol placed on a battery is a reminder not to dispose of batteries with general waste when they reach the end of their usable life.
- For disposal of batteries in other parts of the EU contact your local Megger branch or distributor.
- Megger is registered in the UK as a producer of batteries (registration No.: BPRN00142).
- For further information see www.megger.com
Local Sales office
Megger Limited Archcliffe Road Dover Kent CT17 9EN ENGLAND
T. +44 (0)1 304 502101
F. +44 (0)1 304 207342
Manufacturing sites
-
Megger Limited
Archcliffe Road Dover Kent CT17 9EN ENGLAND
T. +44 (0)1 304 502101
F. +44 (0)1 304 207342 -
Megger USA – Dallas
4545 West Davis Street Dallas TX 75237 USA
T. 800 723 2861 (USA only)
T. +1 214 333 3201
F. +1 214 331 7399
E. USsales@megger.com -
Megger GmbH
Weststraße 59 52074 Aachen GERMAN
T. +49 (0) 241 91380 500
E. info@megger.de -
Megger AB
Rinkebyvägen 19, Box 724, SE-182 17 DANDERYD
T. +46 08 510 195 00
E. seinfo@megger.com -
Megger USA – Valley Forge
400 Opportunity Way Phoenixville, PA 19460 USA
T. +1 610 676 8500
F. +1 610 676 8610 -
Megger USA – Fort Collins
4812 McMurry Avenue Suite 100 Fort Collins CO 80525 USA
T. +1 970 282 1200
This instrument is manufactured in the United Kingdom.
The company reserves the right to change the specification or design without
prior notice. Megger is a registered trademark
The Bluetooth® word mark and logos are registered trademarks owned by
Bluetooth SIG, Inc and is used under licence.
LAKIT_UG_en_V01 06 2022
© Megger Limited 2022
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>