maxspect GF308 Gyre Flow Pump User Manual

August 28, 2024
maxspect

User Manual

GF308 Gyre Flow Pump

Dear Customer,
Thank you for purchasing this product.
For optimum performance and safety, please read these instructions carefully.
User Memo:……………..
Date of purchase:……………….
Dealer name:………………..
Dealer address:………………
Dealer website:……………….
Dealer email:…………………….
Dealer phone no.:…………………………
Please visit us on our Official website, Facebook and Instagram!

Official Website Facebook Instagram
https://maxspect.com/en/ https://www.facebook.com/Maxspect

https://www.instagram.com/maxspect_ig/

Package Contents

Please check the content in the package.

No. Component QTY
1. 1 pc
2. 1 pc
3. 1 pc
4. 2 pcs
5. 4 pcs
6. 2 pcs
7. 2 pcs (Spare Parts)
8. 2 pcs (Spare Parts)
9. 2 pcs (Spare Parts)
10. 2 pcs (Spare Parts)
11. 4 pcs (Spare Parts, for 308 only)
12. 1 pc (for 308 only)

Precautions

Before using this Maxspect™ Jump Series Gyre Flow Pump please read these operating instructions carefully. Take special care to follow the safety suggestions listed below. Afterwards keep this manual handy for future reference.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS

  1. DANGER – To avoid possible electric shock, special care should be taken since water is employed in the use of aquarium equipment. For each of the following situations, DO NOT attempt to repair by yourself; return the appliance to an authorized service facility for service or discard the appliance.
    a) If the appliance shows any sign of abnormal water leakage, immediately unplug it from the power source.
    b) Carefully examine the appliance after installation. It should not be plugged in if there is water on parts not intended to be wet.
    ¢) OO NOT operate any appliance if it has a damaged cord or plug, or if it is malfunctioning or has been dropped or damaged in any manner.
    d) Toavoid the possibility of the appliance’s plug or receptacle getting wet, position aquarium stands and tank to one side of a wall-mounted receptacle to prevent water from dripping onto the receptacle or plug. A “drip-loop” shown in the figure, should be arranged by the user for each cord connecting an aquarium appliance to a receptacle. The “drip-loop” is that part of the cord below the level of the receptacle, or the connector if an extension cord is used, to prevent water traveling along the cord and coming in contact with the receptacle. If the plug or socket does get wet, DO NOT unplug the cord. Disconnect the fuse or circuit breaker that supplies power to the appliance. Then unplug and examine for presence of water in the receptacle.

  2. Close supervision is necessary when any appliance is used by or near children.

  3. To avoid injury, DO NOT contact moving parts or hot parts such as heaters, reflectors, lamp bulbs, and the like.

  4. Always unplug an appliance from an outlet when not in use, before putting on or taking off parts, and before cleaning. Never yank cord to pull plug from outlet. Grasp the plug and pull to disconnect.

  5. DO NOT use an appliance for other than intended use. The use of attachments not fecommended or sold by the appliance manufacturer may cause an unsafe condition.

  6. DO NOT install or store the appliances where it will be exposed to the weather or to temperatures below freezing.

  7. Make sure an appliance mounted on a tank is securely installed before operating it.

  8. Read and observe all the important notices on the appliance.

  9. if an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less amperes or watts than the appliance rating may overheat.

Safety on Power Supply

  1. Power Source – DO NOT defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
  2. Power Cord Protection – The power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them. Never take hold of the plug or cord if your hand is wet, and always grasp the plug body when connecting or disconnecting it.
  3. Installation – Install indoor only, and use the attachments and accessories provided and specified by the manufacturer.

Safety on Magnet Mount

  1. CAUTION – Very strong magnetic mount included in the package.
  2. CAUTION – keep the magnet mount out of reach of children, as there is risk of severe personal injury otherwise!
  3. Handle the magnet mount with their proper handle, and DO NOT bring the both sides together directly. DO NOT put your fingers between the magnet mounts.
  4. Magnet mount can attract metal objects, keep clear of metal objects when handling the magnetic mount to avoid injuries.
  5. Magnet mount can also damage electronic and magnetic storage devices such as USB storage devices, pacemakers, credit cards, etc. Keep clear of these devices when handling the magnetic mount to avoid damaging them.

Safety on Pulsing Motion generated by the Jump System

  1. Making pulses and waves with the Jump System can place additional stress on the aquarium glass/acrylic and its joints. Not all aquariums are able or designed to withstand this stress and failure of the glass/acrylic and/or joints could result. Please consult with your aquarium Manufacturer to determine if the aquarium construction is adequate to withstand the additional stress generated by the pulses and waves motion. Please also check to assure that your aquarium stands or furniture is property leveled, which will help reduce the additional stress resulting from wave generation.
  2. Maxspect DISCLAIMS AND WILL NOT BE LIABLE FOR, damage to any aquarium or their surroundings, water damage, or any other consequential damages resulting from wave generation. MAKE PULSES AND WAVES AT YOUR OWN RISK.

Controller Unit

  1. Operation – Always follow the operation instructions set forth in this manual when using this controller unit.
  2. Heat – The controller unit should be situated away from heat sources such as radiators, and DO NOT expose to excessive heat such as sunshine, fire or the like.
  3. Moisture – To reduce the risk of fire or electric shock, DO NOT expose the controller unit to tain, moisture, dripping or splashing.
  4. Water Damage – DO NOT immerse in water. If the controller unit falls into the water, DO NOT reach for it! First unplug it and then retrieve it. If electrical components of the appliance get wet, unplug the appliance immediately.

Jump Pump

  1. Placement – The pump creates high levels of flow within your aquarium. Please place the pump in an area where corals are not too close to the output flow of the pump.
  2. Stall – Inthe event of a motor stall, the pump may have stopped for a few possible reasons. You should first check that there is not something blocking the rotors from spinning.
  3. Overheating – The pump is designed to run underwater. DO NOT run the pump when it is not submerged in water. Doing so will cause the pump module to overheat and could damage the Pump component.
  4. Cleaning – Please follow the instruction in this manual to clean the pump regularly.

Controller Introduction

Front   Back

Working Mode
Each pump can work in one of three Working Modes: Standalone, Group Leader and Group Member. The grouping mode is only suitable for users who own at least two pumps.
Standatone : Each pump works independently and does not affect each other.
Group Leader : Group leader controls the water movement mode and its working frequency of the group member(s) through wireless signal. The signal range is about 10m(30ft) without obstacles. It can be set at most 10 groups within the same signal range, each group works independently and does not affect each other. There can be only one group leader in each group.
Group Member : The water movement mode and its working speed and frequency of the group member(s) are controlled by its group leader. Its worth noting that the working frequency of the Random Mode is not synchronized by the Group Leader.

Operation

Water Movement Mode Setting

  1. Press button to switch among 5 water movement modes;
  2. After selecting a water movement, press the control dial to enter speed setting, starts to flash;
  3. Rotate the control dial to set the working speed (Constant Speed Mode can be set zero);
  4. Press again the control dial to enter frequency setting, starts to flash;
  5. Rotate the control dial to set the working frequency (invalid for Constant Speed and Random Mode);
  6. Press again the control dial to save all the settings.

Feeding Mode Setting

  1. Press button to activate the Feeding Mode;
  2. After activating the Feeding Mode, press the control dial can enter duration setting;
  3. Rotate the control dial to set the feeding duration (One indicator equals to 6 minutes);
  4. Press again the control dial to save the setting and activate the Feeding Mode;
  5. Press again button can exit the Feeding Mode.

Turn ON/OFF the Device
In all working modes, press and hold button for about 3s can turn ON/OFF the device.
Multiple Pumps Link-up Method
There are two link-up methods for a group to work collaboratively. Once the group member sets up a method, it will work accordingly. Within the same group, each group member can set a different link-up method. Group Leader Setting

  1. Pressand hold ****button for about 3s to enter Grouping setting, logo indicator starts to flash;
  2. Press  button to turn the logo indicator into BLUE;
  3. Press the control dial to enter channel setting, channel indicator starts to flash;
  4. Rotate the control dial to select a channel number (1-10);
  5. Press again the control dial to save the channel setting;
  6. Press and hold  button again for 3s to save all the settings, the logo indicator is back on constant.

Group Member Setting

  1. Press and hold button for about 3s to enter Grouping setting, logo indicator starts to flash;
  2. Press button to turn the logo indicator into VIOLET;
  3. Press the control dial to enter the channel setting, and the channel indicator starts to flash;
  4. Rotate the control dial to set the same channel number which you set for the Group Leader;
  5. Press again the control dial to save the channel setting;
  6. Press and hold  button again for 3s to save all the settings, the logo indicator is back on constant.

Water Movement Mode and Link-up Method Setting for Grouping Mode

  1. Do the setting fotlowing the Water Movement Setting depicted above for the Group Leader;
  2. The working speed and frequency of the Group Member(s) cannot be set independently, they are controlled by the Group Leader;
  3. Press DW button to select a Link-up Method for the Group Member, the indicator is YELLOW for synchronized method, while it is LIGHT GREEN   foranti-synchronized method;
  4. The Feeding Made of the Group Member(s} is(are) controlled by the Group Leader.

Installation & Operation
Please visit Maxspect Official YouTube channel for detailed installation and operation videos.https://qr06.cn/DIbpEZ
Maintenance of the Appliance
Your Jump flow Pump is designed to operate optimally with little attention after initial setup. However, due to the harsh conditions of a saltwater aquarium and resulting buildup of algae and other organic matter, it is advisable to clean the pump to ensure the longevity of appliance. Maxspect recommends doing a cleaning every 6 months or as necessary. This can be accomplished by opening the impeller housing and gently brushing the impeller and inside of impeller housing with a soft brush under running water. If there is calcium buildup, it may be necessary to soak these parts in a mild acid solution such as vinegar. DO NOT use strong acids, because these may damage the components. After cleaning, reassemble the appliance.
Specifications
For the latest specifications of the product, please visit: www.maxspect.comhttps://www.maxspect.com/en/

Limited Warranty

Maxspect (Hong Kong) Limited warrants all Maxspect Jump Series Pump products against defects in workmanship for a period of 12-months from the date of purchase. If a defect exists during the warranty period, Maxspect (Hong Kong) Limited at its option will either repair (using new or remanufactured parts) or replace (with a new or remanufactured unit) the product at no charge.
THE WARRANTY WILL NOT APPLY TO THE PRODUCT IF IT HAS BEEN DAMAGED BY MISUSE, ALTERATION, ACCIDENT, IMPROPER HANDLING OR OPERATION, OR IF UNAUTHORIZED REPAIRS ARE ATTEMPTED OR MADE. SOME EXAMPLES OF DAMAGES NOT COVERED BY WARRANTY INCLUDE, BUT ARE NOT LIMITED TO, USING AFTER-MARKET LED BULBS AND MODIFICATION OF THE CIRCUITRY, WHICH ARE PRESUMED TO BE DAMAGES RESULTING FROM MISUSE OR ABUSE.
DISCLAIMER OF CONSEQUENTIAL AND INCIDENTAL DAMAGES:
You and any other user of Maxspect (Hong Kong) Limited products shall not be entitled to any consequential or incidental damages, including without limitation, loss of use of the unit, inconvenience, damage to personal property, phone calls, lost income or earnings. This warranty gives you specific legal rights and you may also have other rights, which vary from state to state.
MAXSPECT LTD. MAKES NO WARRANTY OR REPRESENTATION, EITHER EXPRESS OR IMPLIED, WITH RESPECT TO THE PRODUCT’S QUALITY, PERFORMANCE, MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE. AS A RESULT, THIS PRODUCT, IS SOLD “AS IS: AND YOU THE PURCHASER ASSUME THE ENTIRE RISK AS TO ITS QUALITY AND PERFORMANCE. IN NO EVENT WILL MAXSPECT LTD BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY DEFECT IN THE PRODUCT OR ITS DOCUMENTATION.
The warranty, disclaimer, and remedies set forth above are exclusive and replace all others, oral or written, expressed or implied. At no time will any Maxspect (Hong Kong) Limited dealers, agents, or employees be authorized to make any modifications, extension, or addition to this warranty.
Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you.

Maxspect Jump Series Gyre Flow Pump User Manual Version 3.1
➢ Products, packaging, features and specifications are subject to change without notice.
➢ All screen images are simulated.
➢ © 2009-2024 Maxspect Limited. Reproduction in whole or in part without written permission is prohibited.
➢ All rights reserved. Maxspect is a trademark of Maxspect Limited.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals