dynamic BIOSENSORS AS-1 Adapter Strand 1 User Manual
- August 28, 2024
- dynamic BIOSENSORS
Table of Contents
dynamic BIOSENSORS AS-1 Adapter Strand 1
Key Features
- Adapter strand 1 – Rc for functionalization of heliX® Adapter Chip Spot 1.
- Compatible with heliX® Adapter Chip.
- Includes Adapter strands for 50 regenerations.
- Ideal for MIX&RUN sample preparation.
- Adapter strand 1 carries a moderately hydrophobic red dye (Rc) with a neutral net charge.
heliX® Adapter Chip Overview
2 spots with 2 different anchor sequences for DNA-encoded addressing.
Product Description
Order Number: AS-1-Rc
Table 1. Contents and Storage Information
Material | Cap | Concentration | Amount | Buffer | Storage |
---|---|---|---|---|---|
Adapter strand 1 – Rc | Black | 400 nM | 5 x 100 µL | TE40 [1] | -20°C |
For research use only.
This product has a limited shelf life, please see expiry date on label..
To avoid many freeze thaw cycles please aliquot the nanolever.
Preparation | MIX&RUN
In-solution hybridization of adapter and ligand strands:
- Mix Adapter strand 1 – Rc (400 nM) and conjugated Ligand strand (500 nM) at 1:1 ratio (v/v).
- Incubate the solution of step 1 at RT at 600 rpm for 30 min to ensure complete hybridization.
- Mix solution of step 2 and Adapter strand 1 – Rc – lfs (200 nM) at 1:1 ratio (v/v).
Solution is ready to use for biochip functionalization.
Stability of the solution is related to the stability of the ligand molecule.
Table 2. Additional material for functionalization of spot 1 and reference spot 2.
Material | Concentration | Buffer | Related Product Name | Order No |
---|
Ligand strand
carrying the conjugated ligand
| 500 nM| 2P] E40 [| heliX® Amine Coupling Kit 1| HK-NHS-1
Adapter strand 1 – Rc – lfs| 200/250 nM| TE40 [1]| Adapter
strand 2 with red dye Rc
prehybridized with ligand-free strand
| AS-2-Rc-lfs
Example
Required volume for 3 functionalizations: 100 μL with a final concentration of
100 nM.
Vial 1 | Vial 2 |
---|
Adapter strand 1 – Rc
(400 nM)
| Conjugated Ligand strand
(500 nM)
| Adapter strand 1 – Rc – lfs
(200/250 nM)
25 µL| 25 µL| 50 µL
After incubation time, mix vial 1 and vial 2 to obtain 100 μL of ready-to-use DNA solution.
Contact
Dynamic Biosensors GmbH
Perchtinger Str. 8/10
81379 Munich
Germany
Dynamic Biosensors, Inc.
300 Trade Center, Suite 1400
Woburn, MA 01801
USA
Order Information order@dynamic-biosensors.com
Technical Support support@dynamic-biosensors.com
www.dynamic-biosensors.com
Instruments and chips are engineered and manufactured in Germany.
©2024 Dynamic Biosensors GmbH | Dynamic Biosensors, Inc. All rights reserved.
- TE40: 10 mM Tris, 40 mM NaCl, 0.05 % Tween20, 50 μM EDTA, 50 μM EGTA
- If the protein is not stable in PE40 (TE40, HE40), please check buffer compatibility with the switchSENSE® compatibility sheet.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>