REDODO 100A BMS 12V 200Ah Low Temp Lithium Battery Instruction Manual

August 23, 2024
REDODO

REDONDO 100A BMS 12V 200Ah Low Temp Lithium Battery

PRODUCT OVERVIEW

12.8V 200Ah Battery

Additional Components

M8- 5/8″‘ (16mm) Terminal Bolts
The terminal bolts are used to secure multiple cable lugs to a single battery terminal. The bolts can be replaced with M8 bolts of other lengths based on actual needs.

Insulating Caps for Bolts

BATTERY-PACK MAIN PARAMETERS

  1. One 12V 200Ah LOW-TEMP battery is suitable for 12V trolling motors up to 70 lbs thrust
  2. identical batteries in series for 24V trolling motors up to 100 lbs thrust
  3. identical batteries in series for 36V trolling motors up to 120 lbs thrust.
  4. The 12V 200Ah LOW-TEMP battery supports Low-Temperature Charging Protection (LTCP), where the BMS stops battery charging when the battery temperature falls below 0°C/32°F and resumes charging when the temperature rises above 5°C/41°F.

HOW TO ESTIMATE THE BATTERY CAPACITY

STATE OF CHARGE (SOC)
The battery capacity could be roughly estimated by its resting voltage (not charging/discharging voltage)®. Since the voltage of each battery is slightly different, and the voltage measurement is affected by the measuring instrument, ambient temperature, etc., the following parameters are for reference only. The actual SOC of the battery is based on the discharge capacity under load.
Resting Voltage: The voltage is measured after the battery has been disconnected from the charger loaded with zero current, and left alone for 3 hours.

Based on the characteristics of LiFePO4 batteries, the voltage measured by all LiFeP04 batteries during charging/discharging is not the real voltage of the battery. Therefore, after charging/discharging and disconnecting the battery from the power source, the voltage of the battery will gradually drop/increase to its real voltage.

THE PREMISE OF CONNECTION
To connect in series or /and parallel, batteries should meet the below conditions:

  • identical batteries with the same battery capacity (Ah) and BMS (A)
  • from the same brand (as lithium batteries from different brands have their special BMS)
  • purchased in near time (within one month).

LIMITATION FOR SERIES/PARALLEL CONNECTION
Support connecting up to 16 identical batteries for up to:

  • in series as 48V (51.2V) battery system
  • in parallel as an 800Ah battery system.

WHAT TO DO WHEN THE BATTERY STOP WORKING?
It has an 85% chance that BMS has shut it off for protection, and you could try one of the below ways to activate the battery.

General Steps
If the BMS has cut off the battery for protection, follow the below steps to activate it.

If the battery is unable to recover itself after the above steps, please try activating by ONE OF BELOW TWO METHODS. After activated (voltage > 10V) and fully charged by the normal charging method, it can be used normally.

Method 1
Use a charger with a lithium battery activation function to fully charge the battery.

Method 2
Connect a controller that supports 12V LiFePO4 battery charging to charge the battery for 3~10s in sunny daytime.

PROVIDER
Shenzhen Maicheng Technology Innovation Co., Ltd.

MANUFACTURER CONTACT
service@redodopower.com
technicalsupport@redodopower.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals