REDODO LOWTEMP-200Ah 12V 280Ah Lithium Battery Instruction Manual
- June 12, 2024
- REDODO
Table of Contents
REDODO LOWTEMP-200Ah 12V 280Ah Lithium Battery Instruction Manual
www.redodopower.com
service@redodopower.com
PRODUCT OVERVIEW
Additional Components
BATTERY-PACK MAIN PARAMETERS
(1) The 12V 280Ah LOW-TEMP battery supports Low Temperature Charging Protection (LTCP), where the BMS stops battery charging when the battery temperature falls below 0°C/32°F and resumes charging when the temperature rises above 5°C/41 °F.
HOW TO ESTIMATE THE BATTERY CAPACITY
STATE OF CHARGE (SOC)
The battery capacity could be roughly estimated by its resting voltage (not charging/discharging voltage)CD.
Since the voltage of each battery is slightly different, and the voltage
measurement is affected by the measuring instrument, ambient temperature,
etc., the following parameters are for reference only.
The actual SOC of the battery is based on the discharge capacity under load.
Resting Voltage: The voltage is measured after the battery has been disconnected from the charger and loads with zero current, and left alone for 3 hours.
- Based on the characteristics of LiFeP04 batteries, the voltage measured by all LiFeP04 batteries during charging/discharging is not the real voltage of the battery. Therefore, after charging/discharging and disconnecting the battery from the power source, the voltage of the battery will gradually drop/increase to its real voltage.
- After this battery is protected from overcharge, the tested battery voltage (not the real voltage) will be lower than the real voltage. To calculate the SOC(%}, add 0.SV to 0.7V to the tested battery voltage.
SERIES/ PARALLEL CONNECTION
THE PREMISE OF CONNECTION
To connect in series or /and parallel, batteries should meet the below conditions:
- a. identical batteries with the same battery capacity (Ah) and BMS (A);
- b. from the same brand (as lithium battery from different brands has their special BMS);
- c. purchased in near time (within one month).
LIMITATION FOR SERIES/PARALLEL CONNECTION
Support connecting up to 16 identical batteries for up to:
4 in series as 48V (51.2V) battery system/
4 in parallel as 1120Ah battery system.
WHAT TO DO WHEN THE BATTERY STOPS WORKING?
It has 85% chances that BMS has shut it off for protection, and you could try one of below ways to activate the battery.
General Steps
If the BMS has cut off the battery for protection, follow the below steps to
activate it.
step 1 Cut off all the connections from the battery
step 2 Leave the battery aside for 30mins
Then the battery will automatically recover itself to normal voltage (>l0V)
and can be used after fully charged.
If the battery is unable to recover itself after the above steps, please try
activating by ONE OF BELOW TWO METHODS.
After activated (voltage> l0V) and fully charged by the normal charging
method, it can be used normally.
Method (1)
Use a charger with lithium battery activation function to fully charge the
battery.
Method (2)
Connect a controller that supports 12V LiFePO4 battery charging to charge the
battery for 3~ 10s in sunny daytime.