REDODO 100A BMS 12V 100Ah Self-Heating Deep Cycle Battery Instruction Manual

June 11, 2024
REDODO

REDODO 100A BMS 12V 100Ah Self-Heating Deep Cycle Battery

PRODUCT OVERVIEW

12.BV l00Ah Battery

Operating Voltage: 12.8V
Charging Voltage: 14.4±0.2V
Recommend Charge Current: 20A (0.2C}
Required Minimum Charge Current (for Heating Function): lSA
Max Continuous Discharge Current: l00A
Max Continuous Load Power: 1280W

Additional Components

M8- 5/8″ (16mm) Terminal Bolts

The terminal bolts are used to secure multiple cable lugs to a single battery terminal. The bolts can be replaced with MS bolts of other lengths based on actual needs.

Insulating Caps for Bolts

BATTERY-PACK MAIN PARAMETERS

Item Parameter
Cell LiFePO4 Battery
Nominal Voltage 12.8V
Rated Capacity l00Ah
Energy 1280Wh
Internal Resistance 40m
Cycle Life  4000 times
Battery Management System (BMS) Board 100A
Charge Method CC/CV
Charge Voltage 14.4V±0.2V
Recommend Charge Current 20A (0.2C)

Required Minimum Charge Current
for Heating Function 1)|  15A
Max. Continuous Charge Current| 100A
Max. Continuous Discharge Current| 1o0A
Max. Discharge Current ls| 330A
Max. Continuous Output Power| 1280W

The charge current should be greater than ISA to activate the automatic  self- heating function.

Item Parameter
Dimension Ll3 W6.77 H8.43 inch

L329 Wl 72 H214 mm
Housing Material| ABS (Flame Retardant Plastic)
Protection Class| IP65
Temperature Range| Charge: -20 to S0°C / -4 to 122°F
Discharge: -20 to 60°C / -4 to 140°F
Storage: -10 to S0°C / 14 to 122°F
Heating Temperature| Charge: -20°C to S°C / -4°F to 41°F
Approx. Heating Time @lSA| 30-60mins (From -l0°C / l4°F)
70-100mins (From -20°C / -4°F)

HOW TO ESTIMATE  THE BATTERY CAPACITY

STATE OF CHARGE (SOC)

The battery capacity could be roughly estimated by its resting voltage (not charging/discharging voltage)CD.
Since the voltage of each battery is slightly different, and the voltage measurement is affected by the measuring instrument, ambient temperature, etc., the following parameters are for reference only.
The actual SOC of the battery is based on the discharge capacity under load.

Resting Voltage:The voltage is measured after the battery has been disconnected from the charger and loads with zero current, and left alone for 3 hours.

soc(%) VOLTAGE (V)
0 10 to 12
25 13 to 13.15
50 13.15 to 13.2
75 13.3 to 13.33
100 13.33
  1. Based on the characteristics of LiFeP04 batteries, the voltage measured by all LiFeP04 batteries during charging/discharging is not the real voltage of the battery. Therefore, after charging/discharging and disconnecting the battery from the power source, the voltage of the battery will gradually drop/increase to its real voltage.

SERIES/ PARALLEL CONNECTION

THE PREMISE OF CONNECTION

To connect in series or /and parallel, batteries should meet the below conditions:
a. identical batteries with the same battery capacity (Ah) and BMS (A);
b. from the same brand (as lithium battery from different brands has their special BMS);
c. purchased in near time (within one month).

LIMITATION FOR SERIES/PARALLEL CONNECTION

Support connecting up to 16 identical batteries for up to:
4 in series as 48V (51.2V) battery system/ 4 in parallel as 400Ah battery system.

Series Connection 48V(51.2V} 1ooAh

Parallel Connection 12V(12.8V) 400Ah

WHAT TO DO WHEN THE BATTERY STOPS WORKING?

When the battery

Can’t work or Can’t be charged or Voltage < 9v

It has 85% chances that BMS has shut it off for protection, and you could try one of below ways to activate the battery.

General Steps

If the BMS has cut off the battery for protection, follow the below steps to activate it.

Cut off all the connections from the battery
Leave the battery aside for 30mins
Then the battery will automatically recover itself to normal voltage (>l0V) and can be used after fully charged.

If the battery is unable to recover itself after the above steps, please try activating by ONE OF BELOW TWO METHODS.
After activated (voltage> l0V} and fully charged by the normal charging method, it can be used normally.

Method 1)

Use a charger with lithium battery activation function to fully charge the battery.

Method 2)

Connect a controller that supports 12V LiFePO4 battery charging to charge the battery for 3~ 10s in sunny daytime.

Customer Support

PROVIDER
Shenzhen Maicheng Technology Innovation Co., Ltd.
MANUFACTURER CONTACT
service@redodopower.com
technicalsupport@redodopower.com

www.redodopower.com
service@redodopower.com