REDODO 200A BMS 12.8V200Ah PLUS Lithium Battery Instruction Manual
- June 10, 2024
- REDODO
Table of Contents
**REDODO 200A BMS 12.8V200Ah PLUS Lithium Battery Instruction Manual
**
PRODUCT OVERVIEW
12.8V 200Ah Battery
Operating Voltage : 12.8V
Charging Voltage : 14.410.2V
Recommend Charge Current : 40A (0.2C)
Max Continuous Discharge Current : 200A
Max Continuous Load Power : 2560W
M8*1.25mm Negative Terminal-
M8*1.25mm Positive Terminal –
Additional Components
8-5/8″ (16mm) Terminal Bolts
The terminal bolts are used to secure multiple cable lugs to a single battery
terminal. The bolts can be replaced with M8 bolts of other lengths based on
actual needs.
Insulating Caps for Bolts
BATTERY-PACK MAIN PARAMETERS
Item | Parameter |
---|---|
Cell Type | LiFePO 4 |
Nominal Voltage | 12. 8 v |
Rated Capacity | 200 Ah |
Energy | 2560Wh |
Internal Resistance | 40m Q |
Cycle Life | 4000 times |
Battery Management System (BMS)Board | 200 A |
Charge Method | cc/cv |
Charge Voltage | 14.4£0.2V |
Recommend Charge Current | 40 A (0.2C) |
Max. Continuous | 200 A |
Max. Continuous Discharge Current | 200A |
Max. Discharge Current One Second | 600A |
Max. Continuous Output Power | 2560W |
Dimension | L21W8.2H8.5inch 1532 W207 H215 mm |
Housing Material | ABS (Flame Retardant Plastic) |
Protection Class | 1P65 |
Temperature Range | Charge: 0°C to 50°C / 32°F to 122°F |
Discharge: -20°C to 60°C / -4°F to 140°F
Storage: -10°C to 50°C / 14°F to 122°F
HOW TO ESTIMATE THE BATTERY CAPACITY
STATE OF CHARGE (SOC)
The battery capacity could be roughly estimated by its resting voltage (not
charging/discharging voltage)®.
Since the voltage of each battery is slightly different, and the voltage
measurement is affected by the measuring instrument, ambient temperature,
etc., the following parameters are for reference only.
The actual SOC of the battery is based on the discharge capacity under load.
Resting Voltage : The voltage is measured after the battery has been
disconnected from the charger and loads with zero current, and left alone for
3 hours.
SOC (%) | VOLTAGE (V) |
---|---|
0 | 10 to 12 |
25 | 13 t0 13.15 |
50 | 13.15t013.2 |
75 | 13.3t013.33 |
100 | 1333 |
- Based on the characteristics of LiFePO4 batteries, the voltage measured by all LiFePO4 batteries during charging/discharging is not the real voltage of the battery. Therefore, after charging/discharging and disconnecting the battery from the power source, the voltage of the battery will gradually drop/increase to its real voltage.
SERIES / PARALLEL CONNECTION
THE PREMISE OF CONNECTION
To connect in series or /and parallel, batteries should meet the below
conditions:
a. identical batteries with the same battery capacity (Ah) and BMS (A);
b. from the same brand (as lithium battery from different brands has
their special BMS);
c. purchased in near time (within one month).
LIMITATION FOR SERIES/PARALLEL CONNECTION
Support connecting up to 16 identical batteries for up to:
4 in series as 48 V (51.2V) battery system/
4 in parallel as 800 Ah battery system.
Series Connection
48V(51.2V) 200Ah
Parallel Connection
12V(12.8V) 800Ah
WHAT TO DO WHEN THE BATTERY STOPS WORKING ?
When the battery
It has 85% chances that BMS has shut it off for protection, and you could try
one of below ways to activate the battery.
General Steps
If the BMS has cut off the battery for protection, follow the below steps to
activate it.
Cut off all the connections from the battery
Leave the battery aside for 30 mins
Then the battery will automatically recover itself to normalvoltage (>10V) and
can be used after fully charged.
If the battery is unable to recover itself after the above steps, please try
activating by ONE OF BELOW TWO METHODS.
After activated (voltage > 10V) and fully charged by the normal
chargingmethod, it can be used normally.
Method 1
Use a charger with lithium battery activation function to fully
charge the battery.
Method 2
Connect a_controller that supports 12V LiFePO4 battery charging tocharge the
battery for 3~10s in sunny daytime.