ELDOM INVEST 150 Household Electric Water Heaters Installation Guide
- August 22, 2024
- ELDOM INVEST
Table of Contents
- 150 Household Electric Water Heaters
- KEY REQUIREMENTS FOR SAFETY
- ENVIRONMENTAL PROTECTION
- TECHNICAL DESCRIPTION
- WATER HEATER INSTALLATION ON THE FLOOR OF THE PREMISE
- WATER HEATER CONNECTION TO THE POWER SUPPLY NETWORK
- HOW TO USE THE APPLIANCE
- CORROSION PROTECTION
- SERVICE, PREVENTION, MAINTENANCE
- FAILURES
- WARRANTY, WARRANTY PER I OD AND WARRANTY CONDITIONS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
www.eldominvest.com HOUSEHOLD ELECTRIC WATER
HEATERS
designed for floor installation (standing water heaters)
150 Household Electric Water Heaters
MANUAL FOR INSTALLATION, OPERATION AND MAINTENANCE, WARRANTY ELEKTRO-
WARMWASSERSPEICHER FÜR DEN HAUSGEBRAUCH
Water heaters without, with one (S) and two (S2) heat exchangers. Water
heaters with two parallel water heaters (S21)
Table № 1
FIG 1 / 2
I| 150| 200| 300| 500| 750| 1000| 1500| 2000
II| ●| ●| ●| —| —| —| —| —
III| 0.67
0.94| 0.90
1.20| 1.12
1.28| 1.85
2.35| 2.03
2.78| 3.04
3.59| 3.04
3.80| 4.25
5.78
IV| 0.30
0.44| 0.38
0.56| 0.86
0.82| 1.15
1.39| 1.22
1.68| 2.03
2.49| 2.03
2.78| 2.73
3.33
V
| 0.67+
0.44
1.20+
0.82| 0.89+
0.67
1.59+
1.20| 1.33+
1.07
2.35+
1.89| 1.71+
1.28
2.35+
1.78| —| —| —| —
VI
1| ¾”| ¾”| ¾”| 1″| 1½”| 1½”| 2″| 2″
2| ¾”| ¾”| ¾”| 1″| 1½”| 1½”| 2″| 2″
3| ¾”| ¾”| ¾”| 1″| 1″| 1″| 1″| 1″
4| ¾”| ¾”| ¾”| 1″| 1″| 1″| 1″| 1″
5| ¾”| ¾”| ¾”| ¾”| ¾”| ¾”| 2″| 2″
6| ½”| ½”| ½”| ½”| ½”| ½”| ½”| ½”
7| 1½”| 1½”| 1½”| 1½”| 1½”| 1½”| 1½”| 1½”
8| —| —| —| —| —| —| ●| ●
9| ●| ●| ●| ●| ●| ●| ●| ●
10| ●| ●| ●| ●| ●| ●| ●| ●
11| ¾”| ¾”| ¾”| 1″| —| —| —| —
12| ¾”| ¾”| ¾”| 1″| —| —| —| —
13| ¾”| ¾”| ¾”| 1¼”| 1¼”| 1¼”| 2″| 2″
VII
D| 600| 600| 670| 800| 1100
(1010)| 1100
(1010)| (1250)| (1400)
H| 1150| 1430| 1605| 1765| 1675
(1655)| 2020
(2000)| (2210)| (2255)
A| 210| 210| 210| 265| 330| 330| 395| 415
B| 260| 260| 265| 320| 420| 420| 445| 465
C| 660| 855| 840| 1000| 950| 1110| 1215| 1255
E| 705| 900| 885| 1045| 990| 1150| 1265| 1285
I| 355| 550| 530| 630| 470| 630| 730| 730
J| 160| 230| 400| 380| 290| 470| 470| 470
P| 890| 1155| 1315| 1425| 1280| 1620| 1755| 1775
K| 260| 260| 265| 320| —| —| —| —
M| 630| 910| 1050| 1105| —| —| —| —
Q| 365| 365| 370| 455| —| —| —| —
R| 420| 700| 840| 835| —| —| —| —
I| CAPACITY RANGE
---|---
II| Without heat exchangers
2
III [m ]| Lower heat exchanger (enamelled/Cr-Ni steel)
IV [m2 ]| Upper heat exchanger (enamelled/Cr-Ni steel)
V [m2 ] (S21) Фиг./ Fig. / Afb. / Рис. / Rys. / Sl. 2| Two parallel heat
exchangers (big+small; enamel/Cr-Ni)
VI [Gxx”,F]| OUTLETS
1 [Gxx”,F]| Inlet pipe
2 / 2* [Gxx”,F]| Outlet pipe
3 [Gxx”,F]| Lower heat exchanger
4 [Gxx”,F]| Upper heat exchanger
5 [Gxx”,F]| Circulation
VI [Gxx”,F]| OUTLETS
6 [Gxx”,F]| Thermostat coupling
7 [Gxx”,F]| Additional coupling
8 [Gxx”,F]| Additional couplings (2 pcs.)
9 [Gxx”,F]| Flange
10 [Gxx”,F]| Thermometer
VI [Gxx”,F]| OUTLETS
11 [Gxx”,F] (S21) Fig. 2| Big heat exchanger
12 [Gxx”,F] (S21) Fig. 2| Small heat exchanger
13 [Gxx”,F]| Outlet pipe
VII [mm]| DIMENSIONS (thermal insulation EPS)
Dimensions in the tables are only approximate.
REMARKS:
- The water heaters are provided with temperature indicator.
- The water heaters without heat exchangers do not have additional couplings.
- With thermostats couplings are provided only water heaters with heat exchangers. Their number depends of the number of heat exchangers.
Table № 1а
Fig. | 1a | 1b | 2a |
---|---|---|---|
I | 150 | 200 | 300 |
III / IV | 0.90 | 1.34 | 1.99 |
1.63 | 1.19+ | ||
2.37 | 2.03+ |
3.80
VI
1| ¾| ¾| ¾| 1| ¾| ¾| 1| ¾| ¾| 1
2| ¾| ¾| ¾| 1| ¾| ¾| 1| ¾| ¾| 1
**2*| ¾| ¾| ¾| 1¼| –| –| –| –| –| –
3, 4| ¾| ¾| ¾| 1| 1| 1| 1¼| 1| 1| 1¼
5| ¾| ¾| ¾| ¾| ¾| ¾| ¾| ¾| ¾| ¾
6| ½| ½| ½| ½| ½| ½| ½| ½| ½| ½
7| –| –| –| –| –| –| –| 1½| 1½| 1½
9| v| v| v| v| v| v| v| v| v| v
10| v| v| v| v| v| v| v| v| v| v
VII**
A| 210| 210| 210| 265| 190| 190| 230| 190| 190| 230
B| 260| 260| 265| 320| 200| 200| 240| 200| 200| 240
D| 600| 600| 670| 800| 670| 670| 800| 670| 670| 800
H| 1150| 1430| 1605| 1765| 1215| 1605| 1765| 1215| 1605| 1765
I| 550| 840| 945| 970| 560| 830| 890| 200| 315| 350
M| 690| 690| 760| 890| 760| 760| 890| 760| 760| 890
P| 890| 1155| 1315| 1425| 950| 1330| 1455| 950| 1330| 1455
E| –| –| –| –| –| –| –| 490| 605| 700
J| –| –| –| –| –| –| –| 440| 640| 675
C| –| –| –| –| –| –| –| 445| 560| 645
for water pressure in the mains above 0,5 MPa
1 | Water supply mains outlet |
---|---|
2 | Stop cock |
3 | Pressure regulator (pressure reducing valve) |
4 | Combined valve |
5 | Pipe diverting water from the combined valve safety valve |
1 | Water supply mains outlet |
---|---|
2 | Stop cock |
3 | Pressure regulator (pressure reducing valve) |
4 | Back flow stop (non-return valve) |
5 | Safety valve |
6 | Pipe diverting water from the safety valve |
7 | Expansion vessel |
8 | Drain cock |
1 | Terminal |
---|---|
2 | Thermal cut-out |
3 | Thermostat |
4 | Switch |
5 | Heating element |
6 | Anode (optional) |
1 | Terminal |
---|---|
2 | Combined the rmostat with thermal cut-out |
3 | Heating element |
4 | LED |
5 | Anode (optional) |
Example: Connecting heat exchangers against increased pressure of the coolant in them.
1 | Air vent valve |
---|---|
2 | Non-return valve |
3 | Stopcock |
4 | MANDATORY! Safety valve |
WARNING! Before installation and operation with the appliance, read carefully the present manual!
KEY REQUIREMENTS FOR SAFETY
Before starting the installation of your appliance and its operation it is
compulsory to read carefully the text of the instructions booklet.
It is designed to familiarize you with the unit, with the rules for its proper
and safe use and the minimum activities necessary to maintain and service it.
Furthermore, you will need to provide this guide for use by qualified persons
who will install and repair the unit in case of failure. Installation and
commissioning of the unit is not a warranty obligation of the seller and/or
manufacturer.
Keep this guide in a suitable place for future reference.
Compliance with the rules helps for safety use of the appliance and is one of
the warranty terms and conditions.
ATTENTION! Installation of the water heater and connection to the water
main system should be performed only by qualified persons in accordance with
the instructions in present manual and local regulations in force.
Installation of safety and other components provided by the manufacturer is
COMPULSORY!
ATTENTION! Connection of the water heater to the water main system should
be performed only by qualified persons in accordance with the instructions in
present manual and local regulations in force. The appliance should be
properly connected to the currentcarrying wires and the protection grid! Do
not connect the appliance to the electrical installation before filling its
water tank up with water! Failure to comply shall make the appliance dangerous
and in such state its use is strictly forbidden!
ATTENTION! Connecting the tank with integrated heat exchangers to a local
heating system (solar and/or other water heating systems using water or water
solution as coolant) must be carried out by qualified and competent persons in
accordance with their design. The way of use of such water heater when heating
the water in its tank from an alternative electric coolant, as well as
compliance with safety measures must be carried out as described in the
supplementary instructions, regulations and requirements for use, servicing
and maintenance.
Such additional instruction booklet is provided by the company responsible for
the design and installation works for connecting the tank to alternative
heating sources.
WARNING! When using the appliance there is a risk of hot water scalding!
WARNING! Do not touch the appliance and its control panel with wet hands
or if you are barefoot or standing on a wet spot!
WARNING! This appliance may be used by children of age over eight years
old and persons with reduced physical, sensory or mental capabilities, or lack
of experience and knowledge, where they are under supervision or instructed
about the safe use of the appliance and understand the dangers. Children must
not be allowed to play with the unit! It is absolutely forbidden that children
undertake cleaning or servicing of this appliance!
ENVIRONMENTAL PROTECTION
This appliance is marked according the REGULATION concerning waste electric
and electronic equipment (WEEE). By ensuring this product is disposed of
correctly, you will help prevent potential negative consequences for the
environment and human health,
which could otherwise be caused by inappropriate waste handling of this
product.
The symbol on the product, or on the accompanying documents indicates that
this appliance may not be treated as household waste. Instead it should be
handed over to the applicable collection point for the recycling of electrical
and electronic equipment. Disposal must be carried out in accordance with
local environmental regulations for waste disposal. For more detailed
information about treatment, recovery and recycling of this product, please
contact your local city office, your household waste disposal service or the
shop where you purchased the product.
TECHNICAL DESCRIPTION
Water heaters are designed for room floor installation to provide hot water
for large family homes.
The heated water should correspond to the normative documents for domestic
water and, in particular its composition of chlorides should be less than 250
mg/l, and the electrical conductivity should be more than 100 µS/cm with pH
within limits of 6.5-9,5 for the water heaters with enameled water tanks
(containers), and less than 200 µS/cm for the water heaters with chrome-nickel
steel water tanks. The water pressure in the water supply system should be
higher than 0.1 MPa and lower than 0.5 MPa. If the water
pressure is higher than 0.5 MPa – please refer to the instructions in the
section for connection to the water supply network. Special water heater
models are in production (for regions where local regulations require) with
design to work in plumbing pressure up to 1 MPa.
The water containers of the appliances are properly protected against
corrosion by using high quality enameled coating, or are made of high-range
alloy chrome-nickel (corrosion resistant) steel. Water tanks with enameled
coating are equipped with built-in anodes made of special alloy providing
additional protection.
The heat isolation is hard (molded) polyurethane or polyester with an outer
shell.
The basic models and modifications are shown on Fig. 1 and 2, while their
specifications are listed in Table 1. Please refer to all figures and tables
in this manual.
The water heater models and their modifications are marked with letters and
numbers as follow:
The first two letters and following five digits indicate the device base
model.
- „F“ – installation on the floor.
- „V“ – mounting position – vertical .
- xxx – the first three digits after the letter “V”, are code of the water heater tank’s capacity range.
- yy – the next two digits are code of the device diameter.
- Letters after the base model are:
- „I“ – the water container of the appliance is made of chrome-nickel steel alloy.
- „F“ – The thermal insulation of the appliance is made of polyester.
- „S“, „S2“, „S21“, „SМ“, „D1“, „D2“ – the water container is equipped with built-in one or two heat exchangers for water heating from an alternative heat source (local water heating, solar collector and any other similar sources). Fig. 1 for “S” and “S2“, Fig. 2 for „S21“, Fig. 1a for “SM”, Fig. 1b for “D1”, Fig. 2a for „D2“.
- „E“ – digital control unit for the heater or for both – the heater and the devices for heat transfer fluid flow control. These appliances are accompanied by additional instructions describing how to use the digital control unit.
- The power for water heaters for ranges up to 200 is up to 3 kW, for ranges 300-500 – up to 9 kW and up to 12 kW for the rest. Produced as well are water heaters with heat exchangers which do not have electric heaters.
- The exact and complete model number, nominal operating parameters and serial number of purchased water heater are marked on its plate affixed on its body.
- In order to ease transportation the water heaters are attached to individual transport pallets.
WATER HEATER INSTALLATION ON THE FLOOR OF THE PREMISE
The water heater can be installed only in normal fire safeguarded premises and
where temperature cannot fall under 0 °C. The availability of a siphon of the
installation for waste waters is necessary on the floor of the premse because
during normal usage of the water heater, water may leak from the combined
valve. At the same time the siphon will facilitate the water tank maintenance,
prevention and servicing operations when water needs to be drained out of the
water tank.
The installation location of the water heater must comply with the outline
dimensions, the location of its pipes, and the degree of protection against
water penetration. The latter is marked on the appliance production plate with
its serial number. The appliance must be protected from water dripping or
spraying. The location of the water heater instalment must be levelled. A
distance between the unit and surrounding walls and ceiling must be allowed in
order to complete the necessary electric and water connections, but not less
than 100 mm.
Before the installation of the appliance if it has been supplied with
transport pallet, start with removing the pallet. Water heaters by ranges up
to 500 are equipped with 3 pcs. feets (supports). If the supports are not in
place they have to be screwed in the apertures which the device was attached
to the transport pallet. The screwed part allows additional appliance
levelling. Larger water heaters must be attached to the room floor through the
same openings that serve for its attachment to the transport pallet.
WARNING! Non observance of the requirements for fixing the water heater
may cause damages to the appliance, to other appliances and the premises,
where the device is located, as well as corrosion of the casing or even more
serious failures and damages. In such cases eventual failures and damages are
not a subject to manufacturer and seller warranty liabilities and will be at
the expense of the party which has not observed the present instructions
manual.
The removal from the transport pallet and the installation of the water heater
on the room floor must be carried out by qualified persons who are due to take
all necessary precautions to prevent accidents.
WATER HEATER CONNECTION TO THE WATER SUPPLY NETWORK
The water heater connection to the water supply network must be performed only
by a qualified service company.
The plumbing (water supply network) to which the water heater will be
connected, as well as any other of its elements shall have to withstand
sustained water temperatures above 80 °C and for short periods – above 100 °C,
as well as to pressure at least twice higher then the appliance work pressure.
The pipes for cold (inlet) and warm (outlet) water of the water heater are
identified by labels with the appropriate inscriptions.
Where the plumbing pipes are copper or of another metal, other than that of
the water tank, or where brass fasteners are used, it is obligatory to install
on the water heater inlet and outlet non-metallic couplings (dielectric
fittings).
Water heaters by ranges up to 500 are equipped with a combined valve – safety
valve and non-return valve located in a common body. The combined valve must
be fitted onto the inlet pipe of the tank, in keeping with the arrow on the
body showing direction of the water passing through it.
The water heaters by ranges 750 and more are equipped with separate safety and
non-return valves.
Water heater connection to the water supply network is shown on Fig 3.
There water heater works at the water supply network pressure and that of the
safety valve. If the water mains pressure is greater than 0,5 MPa a reduce
valve (pressure-reducing valve) have to be installed.
When the water heater is part of a system providing hot water it usually works
at a lower pressure that the pressure in the water supply network, and for its
connection additional fittings are installed. We recommend these connections
to be completed in accordance with Fig. 4. The competent installation company
shall identify and provide the necessary additional fittings. This is not a
manufacturer and/or seller liability, and is not subject to warranty service.
WARNING! It is FORBIDDEN to install any kind of shut-off fittings between
the combined valve and the water heater! It is absolutely forbidden to
obstruct the side opening of the combined valve and/or to block its lever!
It is recommended to set up a draining system for any dripping water from the
combined valve side opening. The draining pipe must have a constant downward
slope and located in frost secure environment and its ends to be constantly
kept open to the atmosphere.
ATTENTION! For appliances with heat exchangers. It is compulsory that all
additional tube outlets (except the outlets of the heat exchangers), which
will not be connected to the plumbing, as well as the outlets for additional
thermostats and/or thermomanometer must be closed with the equipment from the
package, or other suitable equipment for this purpose. The compounds (closed
outlets) should be sealed for water pressure at least 1,6 MPa and temperatures
above 100 °C.
In order to maintain the appliance efficiency, we recommend that to coat /
cover additionally with suitable heat-insulating material that meets the
applicable requirements all its pipe fittings and associated elements.
The water tank shall be filled with water as follows:
- Open completely the turn-cock for hot water of the most distant mixing tap;
- Open the cold water stop cock located before the water heater.
- Wait for the in air the system to come out and then for over a half to one minute from the mixing tap should run full and powerful water jet.
- Close the turn-cock of the mixing tap
- Turn (lift) the combined valve lever or the safety valve cap and wait for about 30 to 60 seconds to run a strong jet of water from the side opening.
WARNING! If no water is coming out of the opening of the combined valve
or the flow is weak (during normal water pressure), this should be considered
as a malfunction indicating that impurities from the plumbing or caused by
sewage connections have blocked the safety valve of the combined valve. IT IS
FORBIDDEN to proceed with appliance electric connection before eliminating the
reason for malfunction.
WARNING! Failure to comply with the requirements for connection to the
water supply system may cause partial filling up of the water tank and
malfunction of the heating element, or when the combined/safety valve is not
installed at all or has been improperly installed this may even cause
destruction of the water tank, the room and/or other damages to tangible and
intangible property. Such consequences are not within the scope of
manufacturer or seller warranty liabilities and shall be at the expense of the
party, which has not observed the present manual instructions.
WARNING! The combined/safety valve is one of the unit safety components
ensuring security for water heater users. It is specifically FORB I DDEN to
use the water heater with adefectiveor removed/unmounted combined safety
valve!
When necessary to drain the water from the water tank proceed as follow:
- Disconnect the heater from the power supply network with the external disconnecting device and for greater security disconnect the fuse(s) in the heater phase circuit.
- Cut the cold water access to the appliance – close the stop cock
- Open the hot water cock on the tap or disconnect the tank hot water pipe (outlet pipe) connection.
- Open the drain cock or lift the combined valve lever and wait until water stops flowing out of it.
These steps do not still secure the complete draining of the water out of the
tank. It is completed only by a qualified person because it requires complete
disconnection of the appliance electric circuit and dismantling the water tank
flange.
WARNING! When draining the water out of the water tank all necessary
precautions must be taken to prevent damages from flowing out water.
WARNING! IT IS STRICTLY PROHIBITED to turn on the heater power while the
water tank is partially or completely emptied of water! Do not forget to fill
the tank with water before putting the appliance back into operation.
WARNING! Heat transfer fluid circulation through the heat exchanger(s) of
a water heater equipped with such device(s) is PROHIBITED when the water tank
is partially or completely emptied of water.
CONNECTING THE HEAT EXCHANGER OF WATER HEATER TO THE ALTERNATIVE HEAT
SOURCE CIRCUIT
The heat exchanger terminals are identified by labels with the appropriate
inscriptions. Only technicians who have designed and implemented the project
for tank water warming from alternative heat source shall connect the
appliance to the alternative heat source installation. The heat transfer fluid
must be driven by circulating pump. As a heat transfer fluid can be used water
with composition and index values within the levels laid down in the
regulations related to water or a dedicated aqueous solution which is not
aggressive to heat exchanger material. The heat transfer fluid must be with
temperature not higher than 85 °С and in its circuit must be installed a
control device set at a temperature not to allow switch on (activation) of the
thermal cut-out of the electrical heating elements during normal operation.
The heat transfer fluid pressure in the heat exchangers should not exceed the
rated pressure of the water heater.
WARNING! It is PROHIBITED to install stop valves on heat exchanger both
ends (inlet and outlet) simultaneously, unless a safety valve is fitted – Fig.
7. In cases where the water heater heat exchanger shall not be used and is not
connected to the heat source circuit, it must be filled with propylene glycol
solution suitable for heating systems. IT IS FORBIDDEN to allow heat transfer
fluid circulation through the heat exchanger when the appliance water tank is
empty.
Connecting the heat exchanger of the water heater to an alternative heat
source circuit must be completed only by qualified technicians, from a company
specializing in such services and in accordance with the requirements in the
design.
WATER HEATER CONNECTION TO THE POWER SUPPLY NETWORK
WARNING! Do not proceed to connect the water heater to the power supply
network unless you have made sure that its water tank is full with water!
Check!
The water heater is completed with degree of protection against electric shock
– Class I.
The single-phase water heaters are connected to 230 V~, three-wires electric
installation in according the electric schema on Fig. 5.
The three-phase water heaters are connected to 400V 3N~, five-wires electric
installation in according the electric schema on Fig. 6.
All ends of wires for the appliance electrical circuit must be properly
connected in the main power switchboard and in the water heater connection
point to the power supply grid. The installation protective conductor must not
be interrupted at no place on its route from the appliance to the main power
switchboard. The cross section of each power cable conductor (3 phase, neutral
and protected) must be not less than 2.5 mm at electric power up to 3 kW/phase
and from 4 to 6 mm 2 at power of 4 kW/phase. The protective conductor MUST be
connected to the terminal or to the stud marked with the sign of protective
grounding. In each circuit, each phase must be installed with 16 A fuse for
power of 9 kW, and 25 A for power of 12 kW. The electric installation to which
the heater will be connected must be built in accordance with the requirements
of the applicable statutes and local regulations in force.
Protective grounding is mandatory for water heaters without electric parts
because these are fitted with electric devices controlling the heat transfer
fluid flow through the coils.
In order to install the power cord to the electric heater input terminals the
plastic cover must be taken off. Once connection is completed it must be
returned on place. During electric connection particular attention must be
paid so that the internal electric wires connectors and the water heater
secure connections be kept together, as well as thermostats and thermal cut-
outs capillary tubes not to be bended or broken.
WARNING! IT IS COMPULSORY that in the electric circuit feeding the heater
is installed such a device which in the conditions of over voltage category
III provides full disconnection of all poles. The conductors between the
circuit and the device incoming electrical terminals must not be interrupted
by any circuit breaker or fuse.
WARNING! Failure to comply with the requirements concerning connection to
the power supply network shall impede the appliance safety, in which it is
prohibited to use. Such consequences are not within the scope of manufacturer
or seller warranty liabilities and shall be at the expense of the party,
which has not observed the present manual instructions.
Only qualified persons are entitled to connect the water heater to the power
supply network and to check its functionality.
HOW TO USE THE APPLIANCE
Once the water heater is installed and connected properly with water and
electric supply networks it should be put into operation and tested for
functionality. The water heater connection and functionality check are not
manufacturer or dealer warranty obligations and are not covered by warranty
service.
Before switching the water heater into operation you must be sure that the
water tank is filled with water. CHECK!
WARNING! Do never switch the appliance if there is a chance that the
water in the water tank is frozen! This shall damage the appliance.
The single-phase water heaters are switched on by pressing the LED key button
end marked ‘I’. With the knob you may adjust to desired water temperature.
Lighting of the key when in switched on position indicates that the water
heater is operating and water is heating, while when the light is off it
indicates that the water has reached adjusted temperature and the heater is
switched off. You may switch off the appliance by pressing the end of the
button of the glowing key marked with “0”. The appliance built-in thermostat
unit has antifreeze function. When the thermostat knob is to the extreme left,
at the scale beginning, the heater shall switch on at ambient temperature
around 8-10°C and shall switch off at about 12-15°C. Thus in case of
airtemperature fall in the room, the water in the tank will be protected from
freezing.
ATTENTION! This feature shall not prevent the water in the room plumbing
from freezing!
There is a sector marked ECO on the graphics around thermostat knob. When the
knob mark is in the ECO sector area the water is heated to optimal temperature
with redused thermal losses and with lower electrical energy consumption. At
the same time the heated water is enough for domestic use. When greater volume
of mixed water is needed the thermostat knob should be set to maximum setting
for reaching higher temperature of the water in the water heater. We recommend
the knob to be set to ECO when the water heater is being switched on for
extended periods of time with no warm water consumption only for storing the
heated water.
The three-phase water heater commissioning and switching in operation is
carried out by switching the external device in position ON when the control
light located on the plastic cover lights on, then the heater is switched on
and starts warming water. When the water temperature reaches the values set on
the thermostat, the control lamp switches off and lights on again after the
water is cooled below a certain degree. The water heater is turned off with
the external device button. The appliance built-in thermostat unit has
Antifreeze function.
The temperature indicator installed on the appliance external coating
indicates the process of water heating. It is not a measurement device and
indicates only the approximate temperature and quantity of hot water within
the water tank.
Using the built-in heater exchangers (for appliances equipped with) to heat
the water in the tank must take place in accordance with the instruction
provided for by the persons who carried out the design and installation of the
system for heating water from alternative electric sources. The technicians
who carried out the design and installation services shall be responsible for
the water heater performance when powered with alternative sources of energy.
CORROSION PROTECTION
Enamelled water heater tanks
In each water heater with enameled tank is installed additional corrosion
protection. It consists of an anode protector (anode) of special alloy
operating only when the water tank is full. The anode is a consumable (i.e. a
device with normal wear during the appliance operation) and its average
operational life is up to 3 years. This period depends much of the type of
operating the appliance and the characteristics of the heated water. After the
period of operational life, a manufacturer authorized specialist or dealer
service company must check the condition of the anode(s). Where necessary it
should be replaced with new one. Compliance with the inspection deadline and
timely replacement of the anode is important for the effective protection of
the tank from corrosion. Both the assessment and replacement of the anode are
not subject of manufacturer and seller warranty liabilities.
Water tanks of high quality chrome-nickel alloy steel Corrosion protection and
guaranteed long life are secured by correct choice of steel, adequate design
and engineering construction during tank manufacture process.
SERVICE, PREVENTION, MAINTENANCE
In order to secure reliable operation of the water tank in areas with highly
calcareous water it is recommended to clean the limestone accumulated within.
This operation should take place at least once every two years, while in areas
with higher limestone content even more frequently. The depositions on the
enamel coating should not be removed otherwise than wiped with dry cotton
cloth and without using hard tools. Regular limestone removal and cleaning is
particularly important for appliance reliable operation. It is recommended
that during this maintenance operation you carry out a review of the enamelled
tank anode condition. These services are not subject to warranty coverage and
must be performed only by qualified person.
WARNING! In order to secure water heater safe and trouble-free operation, the
combined valve should be checked regularly for reduced permeability. This is
carried out by lifting the lever and waiting 30 to 60 seconds from the valve
side edge to run thick and plenty water. This operation must be carried out
after connecting the water heater to the water supply network and when filling
of the tank with water, in the process of using the water heater not less than
once every two weeks, as well as eventually after stop and start of water
supply. If at full tank by opening the valve does not leak water or its flow
is weak, there is a failure and probably the valve is clogged by impurities in
the sewage. Using water heater combined with a defective valve is strictly
prohibited.
Switch off immediately the appliance from the power supply network and contact
the nearest authorized by manufacturer or seller service company. Otherwise,
it will cause damage to the water tank, and could cause tangible and
intangible damages in the room where the water heater is located.
When you are not certain about the temperature in the room where the water
heater is installed, i.e. that it may fall below 0 °C, the water from the
water tank MUST be drained – please refer to section „WATER HEATER CONNECTION
TO THE WATER SUPPLY NETWORK“
The water heater outer shell and plastic parts can be cleaned using only a
slightly damp soft cotton cloth and never with invasive and/or abrasive
substances and preparations. Before cleaning the appliance, it MUST be
disconnected from the power supply network with the additional disconnection
device. IT IS FORBIDDEN to clean the appliance with steam generator. The water
heater may be switched on in operation only after complete removal of
moisture.
The rules for checking the anode and its replacement (please refer to previous
section), as well as removal of the accumulated limestone, must be strictly
observed both during and after the appliance warranty period.
During the appliance usage and maintenance do not damage the metal plate with
its technical data and serial number. Should you take it off, keep it with the
warranty form because it is the document serving to identify the water heater.
FAILURES
If the water heater fails to heat water, check the external device for
disconnection, and for single-phase devices if the switch key is off and / or
the thermostat knob is in minimum position setting.
If the power supply is in order, the circuit breakers are on and the
thermostat knob is in maximum position, but the water in the appliance is
still not warming (it is possible that the lighting key or the signal lamp are
lighted or not), using the external disconnecting device unplug the water
heater and contact the nearest authorized service company.
In case where from the any mixing tap when the hot water cocks are fully open
no water is flowing or the water flow is too weak, check whether the stopcock
before the water heater is not partially or completely closed; if the mains
water supply has not stopped, or if the output filters of the mixers are not
clogged. If all listed above causes are not the cause of failure, using the
external disconnecting device unplug the heater and contact the nearest
authorized service company.
When the water heater is equipped with electronic control board, in the
additional instruction manual there are listed error messages appearing on the
display in case of failure and what measures to take for each case. In any
other general case of failure, using the external disconnecting device unplug
the heater and contact the nearest authorized service company.
WARRANTY, WARRANTY PER I OD AND WARRANTY CONDITIONS
The warranty, warranty conditions, warranty period, warranty validity for
purchased appliance and service related manufacturer or vendor liabilities
during the appliance warranty period are listed in the appliance warranty
form. When buying the appliance the warranty form must be filled and signed
both by seller and buyer. Keep the warranty form in a secure place. In all
instances shall be in force the applicable laws, regulations and other
legislation dealing with the rights and obligations of consumer, seller and
manufacturer, and their relationships related to purchased water heater, its
installation, use, servicing and maintenance.
Warranty term is determined by seller and is in force only for the
geographical territory of the country.
Warranty is valid only if the appliance:
- Is installed according to the requirements for installation and operation.
- Is used only as per designed purpose and in accordance with the installation and operation manual.
Warranty consists of free of charge repair of all factory defects, which may
arise during the warranty term. Repair is performed by service specialists,
authorized by seller.
Warranty is not valid for damages, caused by:
- Improper transportation
- Improper storage
- Improper usage
- Parameters of water, different from the admissible norms for quality of drinking water, and particularly if: the composition of chlorides is morethan 250 mg/l; the electrical conductivity is less than 100 μS/cm and pH is outside of 6,5-9,5 for water heaters with enameled water tanks; the electrical conductivity is more than 200 μS/cm for water heaters with water tanks made of chrome-nickel steel.
- Supply voltage, different than the unit’s rated voltage.
- Damages due to freezing of water.
- Elemental perils, disasters and other force majeure circumstances.
- Non observance of the installation and operation manual.
- In cases, when a non authorized person has tried to repair any kind of a defect.
In the above cases the defect will be repaired against relative payment.
Warranty shall not apply to normal wear parts and components of the device,
parts that are removed during normal use, lighting and signal lamps and the
like, , change of shape, size changing the color of external surfaces and
location of parts and components that are exposed to impact and conditions
that are not considered normal use.
Lost profits, tangible and intangible damages caused by temporary inability to
use the device during its prevention and repair shall not by covered by the
warranty.
COMPLIANCE WITH THE REQUIREMENTS OF THIS INSTRUCTION MANUAL IS A PREREQUISITE
FOR SAFE OPERATION OF YOUR PURCHASED PRODUCT AND IS ONE OF THE WARRANTY TERMS
AND CONDITIONS. IT IS ABSOLUTELY PROHIBITED TO THE USER OR ANY AUTHORIZED BY
HIM PERSON TO UNDERTAKE ANY CHANGES IN THE PRODUCT DESIGN AND STRUCTURE. ANY
FINDING OF SUCH ACTIONS OR ATTEMPTS SHALL AUTOMATICALLY RENDER VOID ALL
WARRANTY LIABILITIES OF SELLER OR PRODUCER.
IN CASE OF NECESSITY FOR SERVICE SEEK ONLY AUTHORIZED SERVICE COMPANIES.
THE MANUFACTURER PRESERVED HISRIGHT TO STRUCTURAL CHANGES WITHOUT NOTICE WHERE
SUCH SHALL NOT AFFECT PRODUCT SAFETY.
Manufacturer:
ELDOMINVEST Ltd.
275A Vl. Varnenchik blvd., Varna, 9009, Bulgaria
www.eldominvest.com
References
- Бойлери, готварски печки, конвектори и плотове за вграждане | Елдоминвест ООД
- Бойлери, готварски печки, конвектори и плотове за вграждане | Елдоминвест ООД
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>