ELDOM INVEST 150-2000 Household Electric Water Heaters Instruction Manual
- June 6, 2024
- ELDOM INVEST
Table of Contents
INVEST Ltd.
www.eldominvest.com.
HOUSEHOLD ELECTRIC WATER HEATERS
designed for floor installation (standing water heaters)
TECHNICAL DESCRIPTION
MANUAL FOR INSTALLATION, OPERATION, AND MAINTENANCE
WARRANTY AND WARRANTY CONDITIONS
– Water heaters without, with one (S) and two (S2) heat exchangers
– Water heaters with two parallel water heaters (S21)
Table 1
CAPACITY RANGE | 150 | 200 | 300 | 500 | 750 | 1000 | 1500 | 2000 |
---|---|---|---|---|---|---|---|---|
Without heat exchangers | • | • | – | – | – | – | – | – |
Lower heat exchanger
(enameled/Cr-Ni steel| 0.67
0.94
[m2]| 0.90
1.20
[ml| 1.12
1.28
[ml| 1.85
2.35
[m2]| 2.03
2.78
[m2]| 3.04
3.59
[m2]| 3.04
3.80
[m2]| 4.25
5.78
[m2]
An upper heat exchanger (enameled/Cr-Ni steel)| 0.30
0.44
[ml| 0.38
0.56
[ml| 0.86
0.82
[ml| 1.15
1.39
[ml| 1.22
1.68
Im21| 2.03
2.49
[ml| 2.03
2.78
[ml| 2.73
3.33
[ml
Two parallel heat exchangers (S21)
(big+small; enamel/Cr-Ni); Fig. 2| 0.67+
0.44
1.20+
0.82
r,21
LI” i| 0.89+
0.67
1.59+
1.20
[nil| 1.33+
1.07
2.35+
1.89
[m2]| 1.71+
1.28
2.35+
1.78
[m2]| –| –| –| –
SCHLUSSFOLGERUNG
1-Inlet pipe | 3/4″ | w | 3%4.,” | 1″ | 1 1/2″ | 1 1/2″ | 2″ | 2″ |
---|---|---|---|---|---|---|---|---|
2 -Outlet pipe | 3/4.,” | 3/: | 3/4.,” | 1″ | 11/2″ | 11/2″ | 2″ | 2″ |
3 – Lower heat exchanger | 3/4.,, | „3/4. | 3%4.,” | 1″ | 1″ | 1″ | 1″ | 1″ |
4 – Upper heat exchanger | 3/4., | 3/4., | 3/4.,” | 1″ | 1″ | 1″ | 1″ | 1″ |
5 – Circulation | 3/4.,., | 3/4., | 3/4.,,. | 3/4. | 3/4. | 3/4. | 2″ | 2″ |
6 – Thermostat coupling | 1/2″ | 1/2″ | 1/2″ | 1/2″ | 1/2″ | 1/2″ | 1/2″ | 1/2″ |
7 – Additional coupling | 11/2″ | 1Y2″ | 11/2″ | 11/2″ | 11/2″ | 11/2″ | 11/2″ | 11/2″ |
8 – Additional couplings (2 pcs.) | — | — | — | — | — | — | • | • |
9 – Flange | • | • | • | • | • | • | • | • |
10 – Thermometer | • | • | • | • | • | • | • | • |
11 – Big heat exchanger | 3/4., | 3/4., | 3/4., | 1″ | — | — | — | — |
12 – Small heat exchanger | 3/4., | 3/4., | 3/4., | 1″ | — | — | — | — |
13 – Outlet pipe | 3/4″ | 3/4., | 3/4″ | 3/4.,” | 11/4″ | 11/4″ | 2″ | 2″ |
Dimensions in the tables are only approximate.
Table 1
| CAPACITY RANGE| 150| 200| 300| 500| 750| 1000| 1500| 2000
---|---|---|---|---|---|---|---|---|---
DIMENSIONS mm
D| | 600| 600| 670| 800| 1100| 1100| 1250| 1400
H| | 1150| 1430| 1605| 1765| 1675| 2020| 2210| 2255
A| | 210| 210| 210| 265| 330| 330| 395| 415
B| | 260| 260| 265| 320| 420| 420| 445| 465
C| | 660| 855| 840| 1000| 950| 1110| 1215| 1255
E| | 705| 900| 885| 1045| 990| 1150| 1265| 1285
I| | 355| 550| 530| 630| 470| 630| 730| 730
J| | 160| 230| 400| 380| 290| 470| 470| 470
P| 890| 1155| 1315| 1425| 1280| 1620| 1755| 1775
K for Fig 2| 260| 260| 265| 320| —| —| —| —
M for Fig 2| 630| 910| 1050| 1105| —| —| —| —
Q for Fig 2| 365| 365| 370| 455| —| —| —| —
R for Fig 2| 420| 700| 840| 835| —| —| —| —
REMARKS:
- The water heaters are provided with temperature indicators.
- The water heaters without heat exchangers do not have additional couplings.
- With thermostats couplings are provided only with water heaters with heat exchangers. Their number depends of the number of heat exchangers.
Dimensions in the tables are only approximate.
Table 1a
Fig., | 1a | l b | (.2a.) |
---|---|---|---|
CAPACITY RANGE | 150 | 200 | 300 |
Heat exchanger | 0.90 | 1. | 2. |
OUTLETS
1.-Inlet pipe| 3/4| 3/4| 3/4| 1| 3/4| 3/4| 1| 3/4| 3/4| 1
2 —Outlet pipe| 3/4| 3/4| 3/4| 1| 3/4| 3/4| 1| 3/4| 3/4| 1
3 —Outlet pipe| 3/4| 3/4| 3/4| 31/4| –| –| –| –| –| –
4, 5 — Heat exchanger| 3/4| 3/4| 3/4| 1| 1| 1| 11/4| 1| 1| 11/4
6 — Circulation| 3/4| 3/4| 3/4| 3/4| 3/4| 3/4| 3/4| 3/4| 3/4| 3/4
7 — Thermostat coupling| IA| IA| IA| IA| IA| IA| IA| IA| IA| IA
8 — Flansch| v| v| v| v| v| v| v| v| v| v
9 — Thermometer| v| v| v| v| v| v| v| v| v| v
10 — Additional coupling| | | –| –| –| –| –| 11/2| 11/2| 11/2
A| | | | 265| | | 230| | | 230
DIMENSIONS| 260
2 0| 260
2 0| 265
265| 320| 200200| 200
200| 240| 200200| 200
200| 240
D| 600| 600| 670| 800| 670| 670| 800| 670| 670| 800
H| 1150| 1430| 1605| 1765| 1215| 1605| 1765| 1215| 1605| 1765
I
[mm]| 550| 840| 945| 970| 560| 830| 890| 200| 315| 350
M| 690| 690| 760| 890| 760| 760| 890| 760| 760| 890
P| 890| 1155| 1315| 1425| 950| 1330| 1455| 950| 1330| 1455
E| –| –| –| –| –| –| –| 490| 605| 700
J| –| –| –| –| –| –| –| 440| 640| 675
C| –| –| –| –| –| –| –| 445| 560| 645
Dimensions in the tables are only approximate
for water pressure in the mains above 0,5 MPa
|
---|---
Stop cock
Pressure regulator
(pressure reducing valve)
Combined valve
Pipe diverting water from the
combined valve safety valve| Water supply mains outlet Stop cock
Pressure regulator (pressure reducing valve)
Back flow stop (non-return valve) Safety valve
Pipe diverting water from the safety valve
Expansion vessel
Drain cock
---|---
Terminal
Thermal cut-out
Thermostat
Switch
Heating element
Anode (optional)
Terminal
Combined thermostat with
thermal cut-out
Heating element
LED
Anode (optional)
WARNING! Before installation and operation with the appliance, read carefully the present manual!
KEY REQUIREMENTS FOR SAFETY
Before starting the installation of your appliance and its operation it is
compulsory to read carefully the text of the instructions booklet. It is
designed to familiarize you with the unit, with the rules for its proper and
safe use and the minimum activities necessary to maintain and service it.
Furthermore, you will need to provide this guide for use by qualified persons
who will install and repair the unit in case of failure. Installation and
commissioning of the unit is not a warranty obligation of the seller and/or
manufacturer. Keep this guide in a suitable place for future reference.
Compliance with the rules helps for safe use of the appliance and is one of
the warranty terms and conditions.
ATTENTION! Installation of the water heater and connection to the water
main system should be performed only by qualified persons in accordance with
the instructions in the present manual and local regulations in force.
Installation of safety and other components provided by the manufacturer is
COMPULSORY!
ATTENTION! Connection of the water heater to the water main system should
be performed only by qualified persons in accordance with the instructions in
the present manual and local regulations in force. The appliance should be
properly connected to the current carrying wires and the protection grid! Do
not connect the appliance to the electrical installation before filling its
water tank up with water! Failure to comply shall make the appliance dangerous
and in such state, its use is strictly forbidden!
ATTENTION! Connecting the tank with integrated heat exchangers to a local
heating system (solar and/or other water heating systems using water or water
solution as coolant) must be carried out by qualified and competent persons in
accordance with their design. The way of use of such water heater when heating
the water in its tank from an alternative electric coolant, as well as
compliance with safety measures, must be carried out as described in the
supplementary instructions, regulations and requirements for use, servicing
and maintenance. Such an additional instruction booklet is provided by the
company responsible for the design and installation works for connecting the
tank to alternative heating sources.
WARNING! When using the appliance there is a risk of hot water scalding!
WARNING! Do not touch the appliance and its control panel with wet hands
or if you are barefoot or standing on a wet spot!
WARNING! This appliance may be used by children of age over eight years
old and persons with reduced physical, sensory or mental capabilities, or lack
of experience and knowledge, where they are under supervision or instructed
about the safe use of the appliance and understand the dangers. Children must
not be allowed to play with the unit! It is absolutely forbidden that children
undertake cleaning or servicing of this appliance!
ENVIRONMENTAL PROTECTION
This appliance is marked according to the REGULATION concerning waste electric
and electronic equipment (WEEE). By ensuring this product is disposed of
correctly, you will help prevent potential negative consequences for the
environment and human health, which could otherwise be caused by inappropriate
waste handling of this product. The symbol on the product, or on the
accompanying documents indicates that this appliance may not be treated as
household waste. Instead, it should be handed over to the applicable
collection point for the recycling of electrical and electronic equipment.
Disposal must be carried out in accordance with local environmental
regulations for waste disposal. For more detailed information about the
treatment, recovery, and recycling of this product, please contact your local
city office, your household waste disposal service or the shop where you
purchased the product.
TECHNICAL DESCRIPTION
Water heaters are designed for room floor installation to provide hot water
for large family homes. The heated water should correspond to the normative
documents for domestic water and, in particular, its composition of chlorides
should be less than 250 mg/l, and the electrical conductivity should be more
than 100 µS/cm with pH within limits of 6.5-8 for the water heaters with
enameled water tanks (containers), and less than 200 µS/cm for the water
heaters with chrome-nickel steel water tanks. The water pressure in the water
supply system should be higher than 0.1 MPa and lower than 0.5 MPa. If the
water pressure is higher than 0.5 MPa – please refer to the instructions in
the section for connection to the water supply network. Special water heater
models are in production (for regions where local regulations require) with
design to work in plumbing pressure up to 1 MPa. The water containers of the
appliances are properly protected against corrosion by using high-quality
enameled coating or are made of high-range alloy chrome-nickel (corrosion
resistant) steel. Water tanks with enameled coating are equipped with built-in
anodes made of special alloy providing additional protection. The heat
isolation is hard (molded) polyurethane or polyester with an outer shell. The
basic models and modifications are shown on Fig. 1 and 2, while their
specifications are listed in Table 1. Please refer to all figures and tables
in this manual. The water heater models and their modifications are marked
with letters and numbers as follows: The first two letters and the following
five digits indicate the device base model.
- „F“ – installation on the floor.
- „V“ – mounting position – vertical.
- xxx – the first three digits after the letter “V”, is the code of the water heater tank’s capacity range.
- yy – the next two digits are code of the device diameter. !Letters after the base model are:
- „I“ – the water container of the appliance is made of chrome-nickel steel alloy.
- „F“ – The thermal insulation of the appliance is made of polyester.
- „S“, „S2“, „S21“, „SМ“, „D1“, „D2“ – the water container is equipped with built-in one or two heat exchangers for water heating from an alternative heat source (local water heating, solar collector and any other similar sources). Fig. 1 for “S” and “S2“, Fig. 2 for „S21“, Fig. 1a for “SM”, Fig. 1b for “D1”, Fig. 2a for „D2“.
- „E“ – digital control unit for the heater or for both – the heater and the devices for heat transfer fluid flow control. These appliances are accompanied by additional instructions describing how to use the digital control unit.
!The power for water heaters for ranges up to 200 is up to 3 kW, for ranges 300-500 – up to 9 kW and up to 12 kW for the rest. Produced as well are water heaters with heat exchangers which do not have electric heaters. !The exact and complete model number, nominal operating parameters, and a serial number of the purchased water heater are marked on its plate affixed on its body. !In order to ease transportation, the water heaters are attached to individual transport pallets.
WATER HEATER INSTALLATION ON THE FLOOR OF THE PREMISE
The water heater can be installed only in normal fire safeguarded premises and
where temperature cannot fall under 0 °C. The availability of a siphon of the
installation for wastewaters is necessary on the floor of the premise because,
during normal usage of the water heater, water may leak from the combined
valve. At the same time, the siphon will facilitate the water tank
maintenance, prevention, and servicing operations when water needs to be
drained out of the water tank. The installation location of the water heater
must comply with the outline dimensions, the location of its pipes, and the
degree of protection against water penetration. The latter is marked on the
appliance production plate with its serial number. The appliance must be
protected from water dripping or spraying. The location of the water heater
installment must be leveled. A distance between the unit and surrounding walls
and ceiling must be allowed in order to complete the necessary electric and
water connections, but not less than 100 mm. Before the installation of the
appliance if it has been supplied with a transport pallet, start with removing
the pallet. Water heaters by ranges up to 500 are equipped with 3 pcs. feet
(supports). If the supports are not in the place they have to be screwed in
the apertures which the device was attached to the transport pallet. The
screwed part allows additional appliance leveling. Larger water heaters must
be attached to the room floor through the same openings that serve for its
attachment to the transport pallet. WARNING! Nonobservance of the
requirements for fixing the water heater may cause damages to the appliance,
to other appliances, and the premises, where the device is located, as well as
corrosion of the casing or even more serious failures and damages. In such
cases, eventual failures and damages are not subject to manufacturer and
seller warranty liabilities and will be at the expense of the party which has
not observed the present instructions manual. The removal from the transport
pallet and the installation of the water heater on the room floor must be
carried out by qualified persons who are due to take all necessary precautions
to prevent accidents.
WATER HEATER CONNECTION TO THE WATER SUPPLY NETWORK
The water heater connected to the water supply network must be performed only
by a qualified service company. The plumbing (water supply network) to which
the water heater will be connected, as well as any other of its elements,
shall have to withstand sustained water temperatures above 80 °C and for short
periods – above 100 °C, as well as to pressure at least twice higher than the
appliance work pressure. The pipes for cold (inlet) and warm (outlet) water of
the water heater are identified by labels with the appropriate inscriptions.
Where the plumbing pipes are copper or of another metal, other than that of
the water tank, or where brass fasteners are used, it is obligatory to install
on the water heater inlet and outlet non-metallic couplings (dielectric
fittings). Water heaters by ranges up to 500 are equipped with a combined
valve – safety valve and non-return valve located in a common body. The
combined valve must be fitted onto the inlet pipe of the tank, in keeping with
the arrow on the body showing the direction of the water passing through it.
The water heaters by ranges 750 and more are equipped with separate safety and
non-return valves. The water heater connected to the water supply network is
shown on Fig 3. Their water heater works at the water supply network pressure
and that of the safety valve. If the water mains pressure is greater than 0,5
MPa a reduced valve (pressure-reducing valve) has to be installed. When the
water heater is part of a system providing hot water it usually works at a
lower pressure than the pressure in the water supply network, and for its
connection, additional fittings are installed. We recommend these connections
to be completed in accordance with Fig. 4. The competent installation company
shall identify and provide the necessary additional fittings. This is not a
manufacturer and/or seller liability, and is not subject to warranty service.
WARNING! It is FORBIDDEN to install any kind of shut-off fittings between
the combined valve and the water heater! It is absolutely forbidden to
obstruct the side opening of the combined valve and/or to block its lever! It
is recommended to set up a draining system for any dripping water from the
combined valve side opening. The draining pipe must have a constant downward
slope and locate in a frost secure environment and its ends to be constantly
kept open to the atmosphere.
ATTENTION! For appliances with heat exchangers. It is compulsory that all
additional tube outlets (except the outlets of the heat exchangers), which
will not be connected to the plumbing, as well as the outlets for additional
thermostats and/or thermomanometer must be closed with the equipment from the
package, or other suitable equipment for this purpose. The compounds (closed
outlets) should be sealed for water pressure at least 1,6 MPa and temperatures
above 100 °C In order to maintain the appliance efficiency, we recommend that
to coat/cover additionally with suitable heat-insulating material that meets
the applicable requirements of all its pipe fittings and associated elements.
The water tank shall be filled with water as follows: џ Open completely the
turn-cock for hot water of the most distant mixing tap; џ Open the cold water
stop cock located before the water heater. џ Wait for the in-air system to
come out and then for over a half to one minute from the mixing tap should run
a full and powerful water jet. џ Close the turn-cock of the mixing tap џ Turn
(lift) the combined valve lever or the safety valve cap and wait for about 30
to 60 seconds to run a strong jet of water from the side opening. WARNING!
If no water is coming out of the opening of the combined valve or the flow is
weak (during normal water pressure), this should be considered as a
malfunction indicating that impurities from the plumbing or caused by sewage
connections have blocked the safety valve of the combined valve. IT IS
FORBIDDEN to proceed with appliance electric connection before eliminating the
reason for malfunction.
WARNING! Failure to comply with the requirements for connection to the
water supply system may cause partial filling up of the water tank and
malfunction of the heating element, or when the combined/safety valve is not
installed at all or has been improperly installed this may even cause
destruction of the water tank, the room and/or other damages to tangible and
intangible property. Such consequences are not within the scope of
manufacturer or seller warranty liabilities and shall be at the expense of the
party, which has not observed the present manual instructions.
WARNING! The combined/safety valve is one of the unit safety components
ensuring security for water heater users. It is specifically FORBIDDEN to use
the water heater with a defective or removed/unmounted combined safety valve!
hen necessary to drain the water from the water tank proceeds as follows: џ
Disconnect the heater from the power supply network with the external
disconnecting device and for greater security disconnect the fuse(s) in the
heater phase circuit. џ Cut the cold water access to the appliance – close the
stop cock џ Open the hot water cock on the tap or disconnect the tank hot
water pipe (outlet pipe) connection. џ Open the drain cock or lift the
combined valve lever and wait until water stops flowing out of it. hese steps
do not still secure the complete draining of the water out of the tank. It is
completed only by a qualified person because it requires complete
disconnection of the appliance electric circuit and dismantling the water tank
flange.
WARNING! When draining the water out of the water tank all necessary
precautions must be taken to prevent damages from flowing out water.
WARNING! IT IS STRICTLY PROHIBITED to turn on the heater power while the
water tank is partially or completely emptied of water! Do not forget to fill
the tank with water before putting the appliance back into operation.
WARNING! Heat transfer fluid circulation through the heat exchanger(s) of
a water heater equipped with such device(s) is PROHIBITED when the water tank
is partially or completely emptied of water.
CONNECTING THE HEAT EXCHANGER OF THE WATER HEATER TO THE ALTERNATIVE HEAT
SOURCE CIRCUIT
The heat exchanger terminals are identified by labels with the appropriate
inscriptions. Only technicians who have designed and implemented the project
for tank water warming from an alternative heat source shall connect the
appliance to the alternative heat source installation. The heat transfer fluid
must be driven by a circulating pump. As a heat transfer fluid can be used
water with composition and index values within the levels laid down in the
regulations related to water or a dedicated aqueous solution that is not
aggressive to heat exchanger material. The heat transfer fluid must be with a
temperature not higher than 85 °С and in its circuit must be installed a
control device set at a temperature not to allow switch on (activation) of the
thermal cut-out of the electrical heating elements during normal operation.
The heat transfer fluid pressure in the heat exchangers should not exceed the
rated pressure of the water heater.
WARNING! It is PROHIBITED to install stop valves on the heat exchanger on
both ends (inlet and outlet) simultaneously. In cases where the water heater
heat exchanger shall not be used and is not connected to the heat source
circuit, it must be filled with propylene glycol solution suitable for heating
systems. IT IS FORBIDDEN to allow heat transfer fluid circulation through the
heat exchanger when the appliance water tank is empty. Connecting the heat
exchanger of the water heater to an alternative heat source circuit must be
completed only by qualified technicians, from a company specializing in such
services and in accordance with the requirements in the design.
WATER HEATER CONNECTION TO THE POWER SUPPLY NETWORK
WARNING!
Do not proceed to connect the water heater to the power supply network unless
you have made sure that its water tank is full of water! Check! The water
heater is completed with a degree of protection against electric shock – Class
I. The single-phase water heaters are connected to 230 V~, three wires
electric installation in according the electric schema on Fig. 5. The three-
phase water heaters are connected to 400V 3N~, five wires electric
installation in according to the electric schema on Fig. 6. All ends of wires
for the appliance electrical circuit must be properly connected in the main
power switchboard and in the water heater connection point to the power supply
grid. The installation protective conductor must not be interrupted at any
place on its route from the appliance to the main power switchboard. The
cross-section of each power cable conductor (3 phase, neutral and protected)
must be not less than 2.5 mm2 at electric power up to 3 kW/phase and from 4 to
6 mm2 at the power of 4 kW/phase. The protective conductor MUST be connected
to the terminal or to the stud marked with the sign of protective grounding.
In each circuit, each phase must be installed with 16 A fuse for the power of
9 kW, and 25 A for the power of 12 kW. The electric installation to which the
heater will be connected must be built in accordance with the requirements of
the applicable statutes and local regulations in force. Protective grounding
is mandatory for water heaters without electric parts because these are fitted
with electric devices controlling the heat transfer fluid flow through the
coils. In order to install the power cord to the electric heater input
terminals, the plastic cover must be taken off. Once the connection is
completed it must be returned on the place. During electric connection,
particular attention must be paid so that the internal electric wires
connectors and the water heater secure connections be kept together, as well
as thermostats and thermal cut-outs capillary tubes not to be bent or broken.
WARNING! IT IS COMPULSORY that in the electric circuit feeding the heater
is installed such a device which in the conditions of overvoltage category III
provides full disconnection of all poles. The conductors between the circuit
and the device’s incoming electrical terminals must not be interrupted by any
circuit breaker or fuse.
WARNING! Failure to comply with the requirements concerning connection to
the power supply network shall impede the appliance safety, in which it is
prohibited to use. Such consequences are not within the scope of manufacturer
or seller warranty liabilities and shall be at the expense of the party, which
has not observed the present manual instructions. Only qualified persons are
entitled to connect the water heater to the power supply network and to check
its functionality.
HOW TO USE THE APPLIANCE
Once the water heater is installed and connected properly with water and
electric supply networks it should be put into operation and tested for
functionality. The water heater connection and functionality check are not
manufacturer or dealer warranty obligations and are not covered by warranty
service. Before switching the water heater into operation you must be sure 18
that the water tank is filled with water. CHECK!
WARNING! Do never switch the appliance if there is a chance that the
water in the water tank is frozen! This shall damage the appliance. The
single-phase water heaters are switched on by pressing the LED key button end
marked ‘I’. With the knob, you may adjust to desired water temperature. The
lighting of the key when in switched on position indicates that the water
heater is operating and water is heating, while when the light is off it
indicates that the water has reached adjusted temperature and the heater is
switched off. You may switch off the appliance by pressing the end of the
button of the glowing key marked with “0”. The appliance built-in thermostat
unit has an antifreeze function. When the thermostat knob is to the extreme
left, at the scale beginning, the heater shall switch on at ambient
temperature around 8-10°C and shall switch off at about 12-15°C. Thus in case
of air temperature fall in the room, the water in the tank will be protected
from freezing.
ATTENTION! This feature shall not prevent the water in the room plumbing
from freezing! There is a sector marked ECO on the graphics around the
thermostat knob. When the knob mark is in the ECO sector area the water is
heated to an optimal temperature with reduced thermal losses and with lower
electrical energy consumption. At the same time the heated water is enough for
domestic use. When a greater volume of mixed water is needed the thermostat
knob should be set to maximum setting for reaching higher temperature of the
water in the water heater. We recommend the knob to be set to ECO when the
water heater is being switched on for extended periods of time with no warm
water consumption only for storing the heated water.
The three-phase water heater commissioning and switching in operation is
carried out by switching the external device in position ON when the control
light located on the plastic cover lights on, then the heater is switched on
and starts warming water. When the water temperature reaches the values set on
the thermostat, the control lamp switches off and lights on again after the
water is cooled below a certain degree. The water heater is turned off with
the external device button. The appliance built-in thermostat unit has an
Antifreeze function. The temperature indicator installed on the appliance
external coating indicates the process of water heating. It is not a
measurement device and indicates only the approximate temperature and quantity
of hot water within the water tank. Using the built-in heater exchangers (for
appliances equipped with) to heat the water in the tank must take place in
accordance with the instruction provided for by the persons who carried out
the design and installation of the system for heating water from alternative
electric sources. The technicians who carried out the design and installation
services shall be responsible for the water heater performance when powered
with alternative sources of energy.
CORROSION PROTECTION
Enamelled water heater tanks
In each water heater with the enameled tank is installed additional corrosion
protection. It consists of an anode protector (anode) of special alloy
operating only when the water tank is full. The anode is a consumable (i.e. a
device with normal wear during the appliance operation) and its average
operational life is up to 3 years. This period depends on the type of
operation of the appliance and the characteristics of the heated water. After
the period of operational life, a manufacturer authorized specialist or dealer
service company must check the condition of the anode(s). Where necessary it
should be replaced with a new one. Compliance with the inspection deadline and
timely replacement of the anode is important for the effective protection of
the tank from corrosion. Both the assessment and replacement of the anode are
not subject of manufacturer and seller warranty liabilities.
Water tanks of high-quality chrome-nickel alloy steel
Corrosion protection and guaranteed long life are secured by the correct
choice of steel, adequate design, and engineering construction during the tank
manufacture process.
SERVICE, PREVENTION, MAINTENANCE
In order to secure reliable operation of the water tank in areas with highly
calcareous water, it is recommended to clean the limestone accumulated within.
This operation should take place at least once every two years, while in areas
with higher limestone content even more frequently. The depositions on the
enamel coating should not be removed otherwise than wiped with a dry cotton
cloth and without using hand tools. Regular limestone removal and cleaning is
particularly important for appliance reliable operation. It is recommended
that during this maintenance operation you carry out a review of the enameled
tank anode condition. These services are not subject to warranty coverage and
must be performed only by a qualified person.
WARNING! In order to secure the water heater safe and troublefree
operation, the combined valve should be checked regularly for reduced
permeability. This is carried out by lifting the lever and waiting 30 to 60
seconds from the valve side edge to run thick and with plenty of water. This
operation must be carried out after connecting the water heater to the water
supply network and when filling of the tank with water, in the process of
using the water heater not less than once every two weeks, as well as
eventually after stop and start of water supply. If at full tank by opening
the valve does not leak water or its flow is weak, there is a failure and
probably the valve is clogged by impurities in the sewage. Using a water
heater combined with a defective valve is strictly prohibited. Switch off
immediately the appliance from the power supply network and contact the
nearest authorized by manufacturer or seller service company. Otherwise, it
will cause damage to the water tank and could cause tangible and intangible
damages in the room where the water heater is located. When you are not
certain about the temperature in the room where the water heater is installed,
i.e. that it may fall below 0 °C, the water from the water tank MUST be
drained – please refer to section „WATER HEATER CONNECTION TO THE WATER SUPPLY
NETWORK“ The water heater outer shell and plastic parts can be cleaned using
only a slightly damp soft cotton cloth and never with invasive and/or abrasive
substances and preparations. Before cleaning the appliance, it MUST be
disconnected from the power supply network with the additional disconnection
device. IT IS FORBIDDEN to clean the appliance with a steam generator. The
water heater may be switched on in operation only after the complete removal
of moisture. The rules for checking the anode and its replacement (please
refer to the previous section), as well as the removal of the accumulated
limestone, must be strictly observed both during and after the appliance
warranty period. During the appliance usage and maintenance do not damage the
metal plate with its technical data and serial number. Should you take it off,
keep it with the warranty form because it is the document serving to identify
the water heater.
FAILURES
If the water heater fails to heat water, check the external device for disconnection, and for single-phase devices if the switch key is off and/or the thermostat knob is in minimum position setting. If the power supply is in order, the circuit breakers are on and the thermostat knob is in maximum position, but the water in the appliance is still not warming (it is possible that the lighting key or the signal lamp are lighted or not), using the external disconnecting device unplug the water heater and contact the nearest authorized service company. In the case where from any mixing tap when the hot water cocks are fully open no water is flowing or the water flow is too weak, check whether the stopcock before the water heater is not partially or completely closed; if the mains water supply has not stopped, or if the output filters of the mixers are not clogged. If all listed above causes are not the cause of failure, use the external disconnecting device to unplug the heater, and contact the nearest authorized service company. When the water heater is equipped with an electronic control board, in the additional instruction manual there are listed error messages appearing on the display in case of failure and what measures to take for each case. In any other general case of failure, using the external disconnecting device unplug the heater and contact the nearest authorized service company.
WARRANTY, WARRANTY PERIOD, AND WARRANTY CONDITIONS
The warranty, warranty conditions, warranty period, warranty validity for the purchased appliance, and service-related manufacturer or vendor liabilities during the appliance warranty period are listed in the appliance warranty form. When buying the appliance the warranty form must be filled out and signed both by the seller and buyer. Keep the warranty form in a secure place. In all instances shall be in force the applicable laws, regulations, and other legislation dealing with the rights and obligations of consumer, seller, and manufacturer, and their relationships related to the purchased water heater, its installation, use, servicing, and maintenance. The warranty term is determined by the seller and is in force only for the geographical territory of the country. Warranty is valid only if the appliance:
- Is installed according to the requirements for installation and operation.
- Is used only as per designed purpose and in accordance with the installation and operation manual. Warranty consists of free-of-charge repair of all factory defects, which may arise during the warranty term. Repair is performed by service specialists, authorized by the seller. Warranty is not valid for damages, caused by:
- Improper transportation џ Improper storage
- Improper usage
- Parameters of water, are different from the admissible norms for quality of drinking water, particularly if: the composition of chlorides is more than 250 mg/l; the electrical conductivity is less than 100
- S/cm and pH is outside of 6,5-8 for water heaters with enameled water tanks; the electrical conductivity is more than 200
- S/cm for water heaters with water tanks made of chrome-nickel steel.
- The supply voltage is different than the unit’s rated voltage.
- Damages due to freezing of water.
- Elemental perils, disasters, and other force majeure circumstances.
- Nonobservance of the installation and operation manual.
- In cases, when a nonauthorized person has tried to repair any kind of defect.
In the above cases, the defect will be repaired against relative payment. Warranty shall not apply to normal wear parts and components of the device, parts that are removed during normal use, lighting and signal lamps and the like, changing the color of external surfaces, change of shape, size, and location of parts and components that are exposed to impact and conditions that are not considered normal use. Lost profits, tangible and intangible damages caused by temporary inability to use the device during its prevention and repair shall not be covered by the warranty.
COMPLIANCE WITH THE REQUIREMENTS OF THIS INSTRUCTION MANUAL IS A PREREQUISITE FOR THE SAFE OPERATION OF YOUR PURCHASED PRODUCT AND IS ONE OF THE WARRANTY TERMS AND CONDITIONS. IT IS ABSOLUTELY PROHIBITED TO THE USER OR ANY AUTHORIZED BY HIM PERSON TO UNDERTAKE ANY C H A N G E S I N T H E P R O D U C T D E S I G N A N D STRUCTURE. ANY FINDING OF SUCH ACTIONS OR ATTEMPTS SHALL AUTOMATICALLY RENDER VOID ALL WARRANTY LIABILITIES OF SELLER OR PRODUCER. IN CASE OF NECESSITY FOR SERVICE SEEK ONLY AUTHORIZED SERVICE COMPANIES. THE MANUFACTURER PRESERVED HIS RIGHT TO STRUCTURAL CHANGES WITHOUT NOTICE WHERE SUCH SHALL NOT AFFECT PRODUCT SAFETY.
Manufacturer:
ELDOMINVEST Ltd.
275A Vl. Varnenchik blvd., Varna, 9009, Bulgaria
www.eldominvest.com