ELDOM INVEST 7-15 Multi Household Electric Water Heaters Instruction Manual
- June 6, 2024
- ELDOM INVEST
Table of Contents
- KEY REQUIREMENTS FOR SAFETY
- ENVIRONMENTAL PROTECTION
- TECHNICAL DESCRIPTION
- INSTALLATION OF THE WATER HEATER ON THE WALL OF THE PREMISES
- CONNECTION OF THE WATER HEATER TO THE WATER SUPPLY NETWORK
- USAGE OF THE APPLIANCE
- CORROSION PROTECTION, PREVENTION MAINTENANCE
- SERVICE, PREVENTION, MAINTENANCE
- FAILURES
- WARRANTY, WARRANTY PERIOD, AND WARRANTY CONDITIONS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
HOUSEHOLD ELECTRIC WATER HEATERS
TECHNICAL DESCRIPTION, MANUAL FOR INSTALLATION, OPERATION AND
MAINTENANCE, WARRANTY, AND WARRANTY CONDITIONS
Installation | For installation above the sink | For installation under sink |
---|---|---|
Fig. | ||
Operation principle | Open-outlet (with free-flow) | Under pressure (closed) |
Under pressure (dosed)
I Model number| 72324NMB| 72325NMB| 72326NMB| 72324NMP| 72325NMP| 72326NMP|
72324PMP| 72325PMP| 72326PMP
Capacity group| 7| 10| 15| 7| 10| 15| 7| 10| 15
Voltage| 230 V∼
Power| 1.5| 1.5| 2| 1.5| 2
Rated pressure /| 0| 0.7| 0.7
Overall dimensions| A [min]| 285| 285| 285| 285| 285| 285| 285| 285| 285
B 1mm]| 288| 288| 288| 288| 288| 288| 288| 288| 288
H [mm]| 340| 430| 520| 340| 430| 520| 340| 430| 520
h [mm]| 390±5| 495±5| 580±5| | | | | |
The parameters amount in the table above are approximate.
For water pressure in the mains above 0,5 MPa.
1 | Water heater |
---|---|
2 | Water inlet |
3 | Water outlet |
4 | Stop cock |
5 | Combined valve |
6 | Reducing valve |
7 | Coldwater |
8 | Hot water |
WARNING! Before installation and operation with the appliance, read carefully the present manual!
KEY REQUIREMENTS FOR SAFETY
Before starting the installation of your appliance and its operation it is compulsory to read carefully the text of the instructions booklet. You must respect its requirements and recommendations in order to help you use the appliance, as well as the authorized persons who shall install and eventually repair the unit in case of malfunction. Compliance with the rules helps for the safe use of the appliance and is one of the warranty terms and conditions. ATTENTION! Installation of the water heater and connection to the water main system should be performed only by qualified persons. Installation of safety and other components provided by the manufacturer is COMPULSORY!
ATTENTION! Connection of the water heater to electrical installation
should be performed only by qualified persons. It must be performed in
accordance with the instructions in the present guide. Moreover, it is
mandatory to meet all requirements of the specific project for installing,
connecting the appliance to heat source and the use and managing of the entire
system. Such a project must be produced by a specialized company that carried
out design and eventually assembling operations.
ATTENTION! It is compulsory to connect the water heater to the
protective earth circuit of the building in which it is installed. This
precaution is necessary because to the water heater are fitted with other
electrical devices used for controlling the entire system.
WARNING! When using the appliance there is a risk of hot water scalding,
especially when the water in the water heater is heated to temperatures closer
the thermostat’s higher limit.
WARNING! It is forbidden to allow circulation of the heating element
through the heat exchanger of the appliance before filling its water tank up
with water!
WARNING! This appliance may be used by children of age over eight years
old and persons with reduced physical, sensory or mental capabilities, or lack
of experience and knowledge, where they are under supervision or instructed
about the safe use of the appliance and understand the dangers. Children must
not be allowed to play with the unit! It is absolutely forbidden that children
undertake cleaning or servicing of this appliance!
ENVIRONMENTAL PROTECTION
This appliance is marked according to the REGULATION concerning waste electric
and electronic equipment (WEEE). By ensuring this product is disposed of
correctly, you will help prevent potential negative consequences for the
environment and human health, which could otherwise be caused by inappropriate
waste handling of this product.
The symbol on the product, or on the accompanying documents indicates that
this appliance may not be treated as household waste. Instead, it should be
handed over to the applicable collection point for the recycling of electrical
and electronic equipment. Disposal must be carried out in accordance with
local environmental regulations for waste disposal. For more detailed
information about the treatment, recovery and recycling of this product,
please contact your local city office, your household waste disposal service
or the shop where you purchased the product.
TECHNICAL DESCRIPTION
The water heater is intended for use only for domestic purposes in the
household and is used to heat water from common water
supply network, which composition and features comply with the specified
values in water quality legislation, such as its chlorides
the composition should be less than 250 mg/l and its electric conductivity
should be more than 100 µS/cm, while its pH within the limits of 6.5-8 for the
water heaters with enameled water tanks, and electric conductivity less than
200 µS/cm for the water heaters with chrome-nickel steel water tanks.
Water heaters are divided into two main groups – working with contained
therein under pressure water and freely flowing water pressurized water
heaters are equipped with a combined return valve, which prevents runtime
water pressure to exceed exposure limits. Water heaters with a free flow of
water on only one consumer (sink) are equipped with a special mixer and can
only be installed over the sink.
Water heaters are manufactured with two types of corrosion protection of the
water container – steel with durable enamel coating and additional cathodic
protection of anodes with special alloy or water containers, high chrome-
nickel stee(marked with the letter “H” in the number of modifications). In
production are as well modifications with the anode status indicator – anode
tester ( “A”).
The thermal insulation of the water container is of foamed polyurethane.
Heaters with free-flow are shown in Fig. 1, under pressure for mounting over
the sink – in Fig. 2, a pressure to be mounted under
the sink – in Fig. 3.
The parameters of basic water heaters with enameled water tanks are recorded
in the table.
INSTALLATION OF THE WATER HEATER ON THE WALL OF THE PREMISES
The water heater can be installed only in normal fire safeguarded premises and
where temperature cannot fall under 0°C. For water heaters under pressure, the
availability of a siphon on the installation for wastewaters or another system
of the same purpose is needed, as during normal usage water may leak from the
safety valve aperture. At the same time the siphon will facilitate the water
tank maintenance, prevention and servicing operations when water needs to be
drained out of the water tank. When choosing a place of installation the
dimensions of the device, its security from dripping water, method of
attachment and connection to water and electricity installations are taken
into account.
WARNING! The water heater is equipped with a power cord with plug and can
be installed in a room for bathing! In the water, heater packaging is placed a
suspension plate (Fig. 4) and 3 pcs. screws and dowels for concrete. With two
of the dowels and screws fasten the hanging plate securely to the wall of the
room. The location of the plate is selected so as to provide sufficient space
for the device and the fittings thereof, and its water and electrical
connections. For water heaters with free flow of water mounted over a sink,
the distance between the outlet of the water supply pipe for cold water from
the wall in which is located the mixing tap and the dowel holes that must be
drilled in the wall are shown in the table. Attention! These distances are
approximate – the exact dimensions are determined by fitting the specific
device! The wall must be of sound and dense material (such as concrete). It is
unacceptable for hanging the unit on decorative walls or make of hollow
material. Once the plate suspension is mounted, then the tank is hung on it.
For this purpose on the device’s rear side, there are provided holes. After
the suspension of the appliance using the third set dowel and screw fix the
unit rigidly to the wall through the opening of the ear of its hull, located
to the side of the cover with the management bodies – see Figures 1-3.
WARNING! Failure to comply with these requirements may result in damage
to the device, other devices and the room in which the appliance is installed.
In these cases, such damages are not covered by the warranty obligations of
the manufacturer and the seller.
CONNECTION OF THE WATER HEATER TO THE WATER SUPPLY NETWORK
Connecting water heater with a free flow The connection of the water heater with free flow over a sink is carried out in accordance with Fig. 1. IT IS COMPULSORY TO USE the mixer and flexible pipes (hoses) placed in the original package. The mixer is a special type and is intended to serve for both hot and cold water from the appliance and to ensure free and constant connection to the outlet pipe device (pipe for hot water) with the atmosphere. The mixer is screwed in the wall to the conduit for cold water. The connection of the hoses to the mixer and heater are carried out in accordance with Fig. 1. Connect the outlet from the mixer top on the side of the knob with red markings to the pipe of the tank marked with a blue insert and arrow to the pipe. The outlet from the upper side of the mixer on side of the knob with a blue insert is connected with the tank pipe marked with a red insert and arrow to the pipe. The hoses should not be crossed! Such connection is a prerequisite for the water heater’s proper and safe operation. The water tank of the appliance is filled with water by the knob with red marking and waiting until the output of the mixer flows out water. With this knob is regulated the flow of cold water in the water tank. Warm water flows freely from the water tank through its exhaust pipe, hose and mixer output. After closing the knob with red marking, the water in the outlet pipe of the appliance and the hose for hot water flows out – this is not a defect and to avoid damage to the mixer the knob with red marking should not be tightened too much. Connecting water heaters under pressure With an arrow towards the pipe and blue color is marked the cold water pipe and with an arrow from the pipe and red color insert – the hot water pipe.
WARNING! IT IS MANDATORY in the cold water to the unit to be mounted the supplied combined return valve and to keep the arrow on the valve body indicating the direction of flow through water flow. IT IS PROHIBITED to mount any valve between the combined valve and the water heater! It is absolutely forbidden to block the side hole of the combined valve! The connection of the water heater under pressure above sink is carried out in accordance with Fig. 5. The connection of the water heater under pressure under sink is carried out in accordance with Fig. 6. IT IS FORBIDDEN to install the combined valve in the space above the unit!
Where the plumbing pipes are copper or of another metal, other than that of
the water tank, or where brass fasteners are used, it is obligatory to install
on the water tank inlet and outlet non-metallic couplings (dielectric
fittings).
Filling the water tank of the unit under pressure is carried out in the
following sequence: open the shut-off valve in the cold water pipe; open the
shut-off valve of the hot water mixing battery; wait until the water flow is
strong and solid; close the tap and hot water; lift the lever of the combined
valve and wait 30-60 seconds of the lateral opening of the valve to flow thick
and strong jet of water; then relax the valve lever.
WARNING! If no water is coming out of the opening of the combined valve
or the flow is weak (during normal water pressure), this should be considered
as a malfunction indicating that impurities from the plumbing or caused by
sewage connections have blocked the safety valve of the combined valve. IT IS
FORBIDDEN to proceed with appliance electric connection before eliminating the
reason for malfunction. If necessary you may make a system for draining
dripping water from the combined valve side hole. The drain pipe must have a
constant downward slope and locate in an anti-freezing environment with
extremities in the atmosphere.
WARNING! Failure to comply with the requirements for connection to the
water supply system may cause partial filling up of the water tank and
malfunction of the heating element, or when the combined valve is not
installed at all or has been improperly installed this may even cause
destruction of the water tank. Such consequences are not within the scope of
manufacturer or seller warranty liabilities and shall be at the expense of the
party, which has not observed the present manual instructions.
Draining the water from the water tank (performed when possible
temperature drop below 0°C in the room where the water heater is, as well as
before eventual repairs) Water heater with free flow Remove the power cord
plug of the heater outlet. Open the knob for hot water and wait until the
outcome him starts to run cold water. Close the knob for hot water. Provide a
vessel that can absorb the water from the water tank. Unscrew from the nipple
of the battery the end of the hose connecting the battery with the water
heater inlet pipe and use the vessel for water collection. Wait until water
stops leaking from the hose. Water heater under pressure for mounting over
the sink
Stop the cold water flow to the tank by closing the cold water tap – pos. 4 of
Fig. 5. Remove the power cord plug of the heater outlet. Open the hot water
tap of the closes mixer in order to free the pressure within the unit.
Disconnect the unit hot water pipe from the water mains in the premises.
Release the combined valve lever. Wait unit from the side edge of the combined
valve stops running of water. Attention! The escaping water may be hot –
beware of burns!
Water heater under pressure for mounting under the sink
Stop the cold water flow to the tank by closing the cold water tap – pos. 4 of
Fig. 6. Remove the power cord plug of the heater outlet. Open the hot water
tap of the closes mixer in order to free the pressure within the unit. Release
the connections of the water mains in the room from the unit pipes for cold
and hot water. Unhook the tank fastening screw and suspension plate and place
it lying on the rear over a sink or a vessel that can accommodate the water
flowing out of the tank. Wait until draining. Attention! The escaping water
may be hot – beware of burns!
WARNING! When draining the water out of the water tank all necessary
precautions must be taken to prevent damages from flowing out water.
WARNING! IT IS ABSOLUTELY PROHIBITED TO SWITCH ON THE POWER SUPPLY TO THE
SYSTEM WHEN THE WATER TANK IS PARTIALLY FILLED OR EMPTY OF ITS WATER CONTENT!
Do not forget to fill the tank with water before putting it back into
operation.
The water heater connected to the water supply system must be performed only
by qualified persons.
WARNING! Do not proceed to connect the water heater to the power supply network unless you have made sure that its water tank is full with water! Check! The water heater competes with a protection degree for electrocution – Class I. Connecting the water heater to the power supply 230 V ~ is carried out rotating the knob for the unit temperature anti-clockwise until it stops and the Illuminated key switches in OFF position (pressed the end marked “0”), has joined the plug on power his cord to the upright and properly connected with protective contact terminals type F or E (Schucco, French type). The wires from the electrical 2 circuit of the contact should be with section 2,5 mm each, and fuse in the phase line is 10 A. The socket must be positioned so that it is easily accessible after installation of the water heater to the wall and connecting it to the water installation. The electric installation to which the heater will be connected must be built in accordance with the requirements of the applicable statutes and local regulations in force. Once the appliance is connected to the power supply grid check its functionality. WARNING! Failure to comply with the requirements concerning connection to the mains shall impede the appliance safety, in which it is prohibited to use. Such consequences are not within the scope of manufacturer or seller warranty liabilities and shall be at the expense of the party, which has not observed the present manual instructions. Only qualified persons are entitled to connect the water heater to the mains and to check its functionality.
USAGE OF THE APPLIANCE
Your water heater is switched on in operating mode by pressing the glowing key
on its end marked “I” and rotating the knob for the temperature clockwise. You
may switch off the appliance by pressing the end of the button of the glowing
key marked “0”. A complete shutdown is done by subtracting the plug on the
power cord from the outlet.
The lighting of the key when in switched on position indicates that the water
heater is operating and water is heating, while when the light is off it
indicates that the water has reached adjusted temperature and the heater is
switched off.
Using the knob the temperature to which it will heat the water may be
adjusted. The chart around the thermostat knob has a distinct sector marked
ECO. When the cursor of the knob is in the sector, the water is warmed to an
optimum temperature at which the heat losses of the device are reduced and the
reduced use of electric energy. At the same time, warm water is sufficient for
normal households. When a need for a large amount of mixed water is required
the thermostat knob is rotated in the direction of travel counterclockwise to
its maximum position, to reach the higher temperature of the water in the
tank. We recommend keeping the knob in the sector ECO when the heater is left
on for long periods without use of hot water and only to store heated water.
The appliance built-in thermostat unit has an antifreeze function. When the
thermostat knob is to the extreme left, at the scale beginning, the heater
shall switch on at ambient temperature around 8-10°C and shall switch off at
about 12-15°C. Thus in case of air temperature fall in the room, the water in
the tank will be protected from freezing. ATTENTION! This feature shall
not prevent the water in the room plumbing from freezing! Within the combined
valve of the water heaters under pressure is built a special controller which
during water heater normal operation allows the expanded during heating water
not to leak through the valve side hole, but to pass into cold water plumbing.
The quantity of this water is negligible and usually is with low temperature.
During normal operation of the water heater, as well as in presence of an
additional return valve, it is possible that through the valve side opening
leak some water drops. This should not be perceived as a defect and the side
hole of the combined valve should not be blocked because it shall cause
destruction of the tank. The built-in controller in the valve prevents, in
case of cutting water supply, the water in the water tank to return to the
cold water pipeline. During the water warming in the water heaters with free
outflow, the water expanded by temperature leaks from the fitting outlet. This
is not a defect! Do not try to stop the drip, as tightening the mixer knobs –
you can damage them!
WARNING! Do never switch the appliance if there is a chance that the
water in the water tank is frozen! This shall damage both heater and the tank.
When the appliance is used in areas with soft water-rich in limestone it is
possible to hear some noises during water heating. The noise is due to the
limestone stitching on the heater contained within the tank. The quantity of
limestone contained depends of the type of water and its heating temperature.
When the latter is higher than 60°С the number of separate limestone
increases. Accumulated limestone impedes the heater efficiency and may even
cause its failure while increasing the time for water heating.
When using the appliance it is possible to hear some weak noise due to the
water flow through the pipelines and the appliance, as well as to the natural
process of expanding and heating. When the heater is regularly used to heat
water to a lower temperature, it is recommended to turn the thermostat knob at
least once monthly to its maximum position, then to heat the water to maximum
degrees and keep it at least for 24 hours in order to prevent bacteria
formation.
CORROSION PROTECTION, PREVENTION MAINTENANCE
Enameled water heater tanks In each water heater with the enameled tank is installed additional corrosion protection. It consists of an anode protector (anode) of special alloy operating only when the water tank is full. The anode is a consumable (i.e. a device with normal wear during the appliance operation) and its average operational life is up to 3(three) years. This period depends on the type of operation the appliance and the characteristics of the heated water. After this period, a manufacturer authorized specialist or dealer service company must check the conditions of the anode. Where necessary it should be replaced with a new one. Compliance with the inspection deadline and timely replacement of the anode is important for the effective protection of the tank from corrosion.
Water heater with enamel tank and anode tester
The availability of this information device (Fig. 7) it is essential for the
operation of the heater. It consists of an arrow-indicating system with a
scale and switch (button). The scale has two sections – red and green. In-tank
normal operating conditions the tester pointer is in the red section – the
tester is not switched on and the anode is working properly. Checking the
anode efficiency is carried out when the water is fully heated (the thermostat
is in position OFF, i.e. the key is not lit) by pressing for few seconds the
button on the tester. The arrow shall depart in the direction of the scale
green sector. The magnitude of the variation is strongly affected by the
parameters of the water and its temperature, as the boundary between the two
sectors corresponds to the water average values. The anode efficiency
criterion is its arrow deflection. When at the time of pressing the tester
button, the arrow does not divert or is held at the beginning of the red
section, you should contact the specialists at your nearest manufacturer or
vendor-authorized service company. They will review the corrosion protection
and repair it if necessary. The timely replacement of the anode protector is a
prerequisite for extending the life of the enameled water tank.
Water tanks of high-quality chrome-nickel alloy steel
Corrosion protection and guaranteed long life are secured by correct choice of
steel, adequate design, and engineering construction during tank manufacture
process.
SERVICE, PREVENTION, MAINTENANCE
In order to secure reliable operation of the water tank in areas with highly calcareous water, it is recommended to clean the limestone accumulated within. This operation should take place at least once every two years, while in areas with higher limestone content even more frequently. The depositions on the enamel coating should not be removed otherwise than wiped with dry cotton cloth and without using hard tools. Regular limestone removal and cleaning is particularly important for appliance reliable operation. It is recommended that during this maintenance operation you carry out a review of the enameled tank anode condition. These services are not subject to warranty coverage and must be performed only by a qualified person. WARNING! To ensure safe and trouble-free operation of pressurized water heater must be checked if it is not reduced permeability of its combined valve. This is done by lifting the lever and wait for 30-60 seconds from the side opening the valve to flow a thick and strong jet of water. This operation must be carried out after connecting the heater to the plumbing and when filling of the tank with water in the process of using the heater not less than once every two weeks, as well as eventually after stop and start of water supply. When at full tank by opening the valve does not leak or water flow is weak, there is a failure and probably the valve is clogged by impurities in the sewage. Using a water heater combined with a defective valve is strictly prohibited. Switch off immediately the appliance from the power supply and contact the nearest authorized by the manufacturer service company. Otherwise, it will cause damage to the water tank and could cause tangible and intangible damages in the room where the water heater is located. The water heater outer shell and plastic parts can be cleaned using only a slightly damp soft cotton cloth and never with invasive and/or abrasive substances and preparations. Before cleaning the appliance, it MUST be disconnected from the power supply by unplugging the plug on the power cord. IT IS FORBIDDEN to clean the appliance with a steam generator. Particular attention should be paid to prevent wetting of the appliance light switch on its control panel. The plug of the cord can be plugged into the socket only after the complete removal of moisture. The rules for checking the anode protection and anode replacement (please refer to the previous section), as well as the removal of the accumulated limestone, must be strictly observed both during and after the appliance warranty period. During the appliance usage and maintenance do not damage the metal plate with its technical data and serial number. Should you take it off, keep it with the warranty form because it is the document serving to identify the water heater.
FAILURES
When the heater does not heat the water, check if the power cord plug is
plugged, if the lighting key is switched off and if the thermostat knob is not
turned to the lowest position. If the power supply is in order, the lighting
key is switched on and the thermostat knob is turned to its highest position,
but the water in the appliance is still not warming (it is possible that the
lighting key or the signal lamp are lighted or not), using the external
disconnecting device unplug the heater plug from the power cord and contact
the nearest authorized service company. In case when from the mixer at the
completely open tap for hot water there is no leakage or water flow is weaker
than normal, check that the inlet mixer nozzle of the instruments with free
flow is not clogged, or if the filter at the mixer outlet is not clogged, or
whether the shut-off valve before the heater is not fully or partially closed
(4 of Fig. 11), or if the water supply is not stopped. If all listed above
causes are not the cause of failure, unplug the plug on the power cord or
using the external disconnecting device unplug the heater, and contact the
nearest authorized service company.
Failure of the mixer of a water heater leak-free and requires replacement with
a new one, it must be of the same type or of a type approved by the
manufacturer of the tank. It is imperative to contact a competent specialist
in this field, as we recommend it to be representative of the manufacturer or
its authorized service company. The installation of an improper and/or
unapproved mixer is a danger! It is forbidden to use the device with such a
mixer! In case of failure of the power cord and plug of contact, the nearest
authorized by the manufacturer service company as the cord with plug must be
replaced by the manufacturer, its service agent, or a person with similar
qualifications in order to avoid danger.
WARRANTY, WARRANTY PERIOD, AND WARRANTY CONDITIONS
The warranty, warranty conditions, warranty period, warranty validity for purchased appliance and service-related manufacturer or vendor liabilities during the appliance warranty period are listed in the appliance warranty form. When buying the appliance the warranty form must be filled and signed both by the seller and buyer. Keep the warranty form in a secure place. In all instances shall be in force the applicable laws, regulations and other legislation dealing with the rights and obligations of consumer, seller and manufacturer, and their relationships related to the purchased water heater, its installation, use, servicing and maintenance.
Warranty term is determined by seller and is in force only for the geographical territory of the country. Warranty is valid only if the appliance:
- Is installed according to the requirements for installation and operation.
- Is used only as per designed purpose and in accordance with the installation and operation manual.
Warranty consists of free-of-charge repair of all factory defects, which may arise during the warranty term. Repair is performed by service specialists, authorized by the seller. Warranty is not valid for damages, caused by:
- Improper transportation
- Improper storage
- Improper usage
- Parameters of water, different from the admissible norms for quality of drinking water, and particularly if: the composition of chlorides is more than 250 mg/l; the electrical conductivity is less than 100 μS/cm and pH is outside of 6,5-8 for water heaters with enameled water tanks; the electrical conductivity is more than 200 μS/cm for water heaters with water tanks made of chrome-nickel steel.
- Supply voltage is different than the unit’s rated voltage.
- Damages due to freezing of water.
- Elemental perils, disasters and other force majeure circumstances.
- Nonobservance of the installation and operation manual.
- In cases, when a nonauthorized person has tried to repair any kind of defect.
In the above cases, the defect will be repaired against relative payment. Warranty shall not apply to normal wear parts and components of the device, parts that are removed during normal use, lighting and signal lamps and the like, re-painting color of external surfaces, change of shape, size and location of parts and components that are exposed to impact and conditions that are not considered normal use. Lost profits, tangible and intangible damages caused by temporary inability to use the device during its prevention and repair shall not by covered by the warranty.
COMPLIANCE WITH THE REQUIREMENTS OF THIS INSTRUCTION MANUAL IS A PREREQUISITE FOR THE SAFE OPERATION OF YOUR PURCHASED PRODUCT AND IS ONE OF THE WARRANTY TERMS AND CONDITIONS. IT IS ABSOLUTELY PROHIBITED TO THE USER OR ANY AUTHORIZED BY HIM PERSON TO UNDERTAKE ANY C H A N G E S I N T H E P R O D U C T D E S I G N A N D STRUCTURE. ANY FINDING OF SUCH ACTIONS OR ATTEMPTS SHALL AUTOMATICALLY RENDER VOID ALL WARRANTY LIABILITIES OF SELLER OR PRODUCER. IN CASE OF NECESSITY FOR SERVICE SEEK ONLY MANUFACTURER AUTHORIZED SERVICE COMPANIES LISTED IN THE ANNEXED FORM. THE MANUFACTURER PRESERVED HIS RIGHT TO STRUCTURAL CHANGES WITHOUT NOTICE WHERE SUCH SHALL NOT AFFECT PRODUCT SAFETY.
http://eldominvest.com/bg/services.html
References
- Бойлери, готварски печки, конвектори и плотове за вграждане | Елдоминвест ООД
- Бойлери, готварски печки, конвектори и плотове за вграждане | Елдоминвест ООД
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>