DECLARATION
Thank you for choosing Core Tomorrow (CoreMorrow for short) products!
This user manual is applicable to XD002 Piezo Clamp, for your smooth and
correct use of this product, please read this manual carefully before using
it. Please follow the instructions in the installation and use process.
Improper operation may cause injury to the operator and/or damage to the
product, so it is required that the entire installation and operation process
should be completed by professionals with a certain foundation and a certain
understanding of product principles, or under the guidance of a professional.
If you disassemble or transform the product without permission, our company
will not be responsible for any consequences arising therefrom.
To change the product model and other false sales of our company’s products
are illegal, users should be vigilant. Once found, you should actively report
or contact our company, jointly crack down on illegal acts, and prevent fraud
and economic losses. CoreMorrow will investigate for the legal responsibility
of the illegal subject and related party.
With the continuous development and innovation of technology, CoreMorrow will
timely add the latest information to the manual as required. If you need,
please contact us, or to our website
www.coremorrow.com for download, we apologize for
any inconvenience caused to you.
Introduction
Purpose and content
- This manual is mainly for your smooth and correct use of XD002 Piezo Clamp.
- The manual contains all the necessary information for the XD002 Piezo Clamp.
- Introduction of the precautions during installation and use.
Symbol and meaning
DANGER: Improper handling may could cause injury to the operator.
Attention: Improper handling can cause damage to the equipment.
No order between items.
Please operating in order.
Users of This Manual
The default user of this manual has knowledge of piezoelectric products and controllers, and has a certain basis for their installation and use.
Manual Lost and Reissued
If this manual is lost, please contact CoreMorrow. We will send you the latest version of the user manual.
Safety Guide
XD002 Piezo Clamp is designed with the most advanced technology and safety standards for your own safety and the correct use of the product, please observe the following points when in use.
A change in temperature and pressure will charge the piezoelectric actuator, and the actuator will remain charged for a period of time when it is disconnected from the controller, so the operator should pay attention to when in use.
- Do not disassemble XD002 Piezo Clamp;
- Discharge XD002 before installation, which can be done by connecting to the controller;
- Do not unplug the wire connecting with controller during operation;
- Before use, check whether the connection wire of the product is in good condition and whether the product and the controller are effectively grounded. During operation, strictly standardize the operation. Do not touch the product (up to 150V voltage) with your hand when power on, in case of danger.
In order to prevent damage to the product caused by improper operation, the following points should be paid attention to when in use
- XD002 Piezo Clamp should be used in a dust-free, oil-free and lubricant-free environment;
- As the product is designed with flexible structure, it is recommended that the load should not exceed load capacity of product. When loading, DO NOT apply torque force and DO NOT pry or twist the load surface, so as not to damage the structure;
- Recommended voltage range is 0~120V for long-term use and lifetime;
- Do not disassemble the product to avoid damage;
- Avoid stretching and bending the cable interface to prevent damage to the cable;
- Use the dedicated cable provided by CoreMorrow to connect XD002 Piezo Clamp to controller;
- Do not connect via an extension cable casually, if you need a longer cable, please contact CoreMorrow.
Product Overview
Product Introduction
XD002 Piezo Clamp has the following advantages:
High performance piezo stack: XD002 Piezo Clamp is driven by a highly
reliable ceramic actuator with a fully insulated structure, so its performance
and service life are far better than the traditional actuator.
The insulating layer can effectively prevent the piezoelectric ceramic from
being damaged when exposed to moisture. Therefore, the stability of
piezoelectric ceramics can be guaranteed under extreme circumstances. Compared
with traditional driving mechanism, there are no transmission parts and
friction. Therefore, ceramic actuator has the characteristics of no rebound,
no maintenance, and no wear, etc.
Flexible hinge structure:
XD002 Piezo Clamp adopting flexible hinge mechanism has advantages of no
friction, high positioning accuracy. Flexible hinge is an element not affected
by static and dynamic friction, based on the elastic deformation of metal
material (e.g., steel) , there is no rolling and sliding parts. Flexible unit
has very high load capacity and stiffness. Hinge guide needs no maintenance
and no wear and tear. Suitable for a wide range of temperatures, no
lubricating oil is required.
XD002 Piezo Clamp can travel up to ±100μm, with no mechanical friction, fast
response speed, high repeat positioning accuracy advantages. This product can
also be customized according to the needs, with high flexibility, easy to
operate, to meet different applications. applications.
This product can also be customized according to the requirements.
Product Features
- Small size and large displacement;
- High positioning accuracy.
Motion direction
Operating environment
- Operating temperature: -20~80℃
- Environment free of dust, clean, and non-corrosive substances
- Relative humidity: <60%
- Recommended voltage between 0 and 120V for long-term and high reliability operation.
Installation and operation
The mounting diagram of XD002 is as follows:
Installation and connection
- Make sure the mounting surface is flat.
- Use M2.5 screws to mount the N60 and tighten.
- Make lead wire through wire hole in the front end of the clamp;
- Connect XD002’s connector to the corresponding interface of the controller according to the identification on the leads.
Notice:
- When mounting the load, tighten the load slowly. The torque should not be too large to prevent damage to the mechanism.
- Avoid stretching and bending cables.
- Use the dedicated cable provided by CoreMorrow to connect XD002 and the controller.
- Do not connect via an extension cable casually, if you need a longer cable, please contact CoreMorrow.
Operating
Please reconfirm the following information before turning on the power:
The operating environment meets the operating environment requirements of XD002.
Fixed screws must be tightened.
After the above information is confirmed, relevant controller operations can be carried out:
- Please read the user manual of the controller carefully before operation, and then start the controller.
- Set the controller’ output voltage to zero first.
- Check no abnormal phenomenon, then input voltage value (via keyboard or analog control) according to specified input voltage range.
- Operating normally within the rated voltage range of piezoelectric ceramics (0~120V, maximum 150V).
- After use, please carry out voltage reset operation.
Please take light steps when N60 in operation, do not knock the product, so as
not to affect the use of the product or even damage the product.
The resolution of the product itself is unlimited, and the resolution depends
on the performance of the controller. In order to achieve better motion
precision of XD002, it is recommended to use our company’s supporting
controller. Please refer to the user manual of the controller for the specific
operation to ensure correct operation before relevant operation.
Notes:
Do not remove the grounding protection during the operation. If you need to
remove it temporarily, please reconnect the grounding protection before
starting it again.
The driving voltage shall not exceed the voltage range of XD-002(150V).
If any abnormal noise or oscillation occurs during use, turn off the power
immediately and check the parameter setting.Notes:
-
Do not remove the grounding protection during the operation. If you need to remove
it temporarily, please reconnect the grounding protection before starting it again. -
The driving voltage shall not exceed the voltage range of N60.
-
If any abnormal noise or oscillation occurs during use, turn off the power immediately and check the parameter setting.
Transportation and inspection
Transportation
This product is packed in cartons. Transportation is carried out under the packaging conditions. This product can be transported by various means of transport under normal circumstances. In the process of transportation, direct rain and snow, corrosive substances, strong collision, extrusion, irregular placement and other improper behaviors should be avoided as far as possible.
Open-Box Inspection
Inspection content:
- Before opening the package, please check the outer packing carefully to see if there is any breakage, wetting, dampness, deformation, etc.
- Please check the completeness of package contents one by one according to the supply contract and packing list.
- Check whether the surface of the product has obvious damage.
- Check whether the product identification is clear and complete.
- Check whether the connector is loose and the connector wire is broken or damaged.
In case of any of the above, please make a detailed record and take a photo of
it.
Meanwhile, please contact us for processing immediately.
Attention:
- Please handle with care when opening the package, so as not to knock against the product and cause permanent damage to it.
- Please do not use heavy tools or rough way to open.
- Please do not discard all the packaging materials which are needed for repair and return.
Maintenance and Treatment
Problem Handling
FAQ are shown in the table below.
Problem description | Possible reason | Solution |
---|---|---|
No displacement or less displacement | The connection wire is not connected | |
properly or poor contact | Check the connection wire | |
Excessive load | Load according to the product’s load capacity | |
Sensor zero drift | Check the sensor | |
Low accuracy | Mounting surface unevenness | Mount the platform on a flat |
surface
Loose connection| Fasten connection
Wrong connection| Check if the wiring is correct
Vibration or inaccurate positioning at startup| Incorrect input control
parameters| Stop immediately and check the parameter Settings
Resonance occurs| Make drive frequency less than resonance frequency
Table 1 FAQ and solutions
If the user cannot solve the problem by himself in the process of using, please record the problem in detail and contact CoreMorrow, and professional technical personnel will help to solve.
Problems caused by improper operation are not covered by the warranty.
CoreMorrow is not responsible for any problems caused by dismantling products without permission.
Daily maintenance
If the product is not used for a long time, please store it in a dust-free,
well-ventilated, clean and non-corrosive indoor environment after packaging.
In the daily maintenance, please do not loosen the bolts on the product
structure, so as not to affect the movement accuracy of the product.
Daily cleaning:
Please disconnect the product from the controller before cleaning the surface
of the product.
When cleaning, gently wipe the surface of the product with a towel dipped in a
small amount of detergent, and then clean it with alcohol. Please do not use
ultrasonic cleaner.
When cleaning the surface, try not to pick up the product. If you have to pick
up the product, it is better to put the sponge under the product for
protection. The product should not be too high from the sponge, in case the
product falls off.
Disposal
Waste products should be disposed according to national and local rules and
regulations.
In order to fulfill our responsibility as a product manufacturer, we will
dispose all old equipments on the market in an environmentally friendly
manner. If you have equipment that cannot be disposed, you can ship it to
CoreMorrow.
Address: Building I2, No.191 Xuefu Road, Nangang District, Harbin, HLJ, China
Tel: +86-451-86268790
Customer Service
If you have questions about the products you are currently using, please let us know the following information:
- Product model and relevant number
- The controller model
- Software driver version
- Computer operating system that installs supporting software
Contact us
Harbin Core Tomorrow Science & Technology Co., Ltd.
Tel: +86-451-86268790
Email: info@coremorrow.com
Website: www.coremorrow.com
Address: Building I2, No.191 Xuefu Road, Nangang District, Harbin, HLJ, China
CoreMorrow Official and CTO WeChat are below:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>