This document describes the following products: ZT35H80K
DECLARATION
Thank you for choosing Core Tomorrow (CoreMorrow for short) products! This
user manual is applicable to ZT35H80K Phase Phase Shifter, for your smooth and
correct use of this product, please read this manual carefully before using
it. Please follow the instructions in the installation and use process.
Improper operation may cause injury to the operator and/or damage to the
product, so it is required that the entire installation and operation process
should be completed by professionals with a certain foundation and a certain
understanding of product principles, or under the guidance of a professional.
If you disassemble or transform the product without permission, our company
will not be responsible for any consequences arising therefrom. To change the
product model and other false sales of our company’s products are illegal,
users should be vigilant. Once found, you should actively report or contact
our company, jointly crack down on illegal acts, and prevent fraud and
economic losses. CoreMorrow will investigate for the legal responsibility of
the illegal subject and related party. With the continuous development and
innovation of technology, CoreMorrow will timely add the latest information to
the manual as required. If you need, please contact us, or to our website
www.coremorrow.com for download, we apologize for
any inconvenience caused to you.
Introduction
1.1 Purpose and Content
- This manual is mainly for your smooth and correct use of ZT35H80K.
- The manual contains all the necessary information for ZT35H80K Piezo Phase Shifter.
- Introduction of the precautions during installation and use.
1.2 Symbols and Meanings
DANGER: Improper handling may could cause injury to the operator.
Attention: Improper handling can cause damage to the equipment.
No order between items.
1. Please operating in order.
1.3 Users of This Manual
The default user of this manual has knowledge of piezoelectric products and
controllers, and has a certain basis for their installation and use.
1.4 Manual Lost and Reissued
If this manual is lost, please contact CoreMorrow. We will send you the latest
version of the user manual.
Safety Guide
ZT35H80K Piezo Phase Shifter is designed with the most advanced technology and
safety standards for your own safety and the correct use of the product,
please observe the following points when in use.
**** A change in temperature and pressure will charge the piezoelectric
actuator, and the actuator will remain charged for a period of time when it is
disconnected from the controller, so the operator should pay attention to when
in use:
- Do not disassemble ZT35H80K Piezo Phase Shifter.
- Discharge ZT35H80K before installation, which can be done by connecting to the controller.
- Do not unplug the wire connecting with controller during operation.
- Before use, check whether the connection wire of the product is in good condition and whether the product and the controller are effectively grounded. During operation, strictly standardize the operation.
- Do not touch the product (up to 150V voltage) with your hand when power on, in case of danger.
****In order to prevent damage to the product caused by improper operation, the following points should be paid attention to when in use.
- ZT35H80K Piezo Phase Shifter should be used in a dust-free, oil-free and lubricantfree environment.
- As the product is designed with flexible structure, it is recommended that the load should not exceed load capacity of product.
- When loading, DO NOT apply torque force and DO NOT pry or twist the load surface, so as not to damage the structure.
- Recommended voltage range is 0~120V for long-term use and lifetime.
- Do not disassemble the product to avoid damage. Avoid stretching and bending the cable interface to prevent damage to the cable.
- Use the dedicated cable provided by CoreMorrow to connect ZT35H80K Piezo Phase Shifter to controller.
- Do not connect via an extension cable casually, if you need a longer cable, please contact CoreMorrow.
Product Overview
3.1 Product Introduction
ZT35H80K Phase Phase Shifter has the following advantages:
High performance piezo ceramic:
ZT35H80K Phase Phase Shifters is driven by a highly reliable ceramic actuator
with a fully insulated structure, so its performance and service life are far
better than the traditional actuator. The insulating layer can effectively
prevent the piezoelectric ceramic from being damaged when exposed to moisture.
Therefore, the stability of piezoelectric ceramics can be guaranteed under
extreme circumstances. Compared with traditional driving mechanism, there are
no transmission parts and friction. Therefore, ceramic actuator has the
characteristics of no rebound, no maintenance, and no wear, etc.
Flexible hinge structure:
ZT35H80K Phase Phase Shifter adopting flexible hinge mechanism has advantages
of no friction, high positioning accuracy. Flexible hinge is an element not
affected by static and dynamic friction, based on the elastic deformation of
metal material (e.g., steel) , there is no rolling and sliding parts. Flexible
unit has very high load capacity and stiffness. Hinge guide needs no
maintenance and no wear and tear. Suitable for a wide range of temperatures,
no lubricating oil is required.
3.2 Product Features
- The phase shift stroke is about 0.9 µm@150V.
- The upper limit of phase shift stroke can reach 4.82 µm@800V.
- You can manually adjust the deflection Angle of x y Adjustment Angle range in x y is 0~±4°
- The standard loadable mirror has a diameter of 35mm and can be customized.
3.3 Motion Direction
Operating environment
- Operating temperature: -20~80
- Environment free of dust, clean, and non-corrosive substances
- Relative humidity: <60%
- Recommended voltage between 0 and 120V for long-term and high-reliability operation.
Installation and operation
Safety check should be carried out before installation, such as whether the
connection wire is damaged or broken, whether the drive power supply is
grounded, etc.
5.1 Installation and Precautions
-
Ensure that the installation plane is relatively flat;
-
Fix the platform with M6 screw and tighten it;
N50 Installation diagram is as follows: -
Install a mirror at the dotted line as shown in FIG 4. Properly tighten the lens mounting screws to ensure positioning accuracy;
-
Connect the product connection line with the corresponding interface of the controller according to the identification on the connector head.
Note: Do not misconnect the positive and negative terminals of
piezoelectric actuator.
Too long screws selected in the fastening and connection process will lead to
failure of mounting or part of bolts will be exposed, which will scratch the
product and affect the motion accuracy of the product. If the bolt is too
short, the connection will be weak, and it is easy to be loosened. Loosening
during operation will damage the internal structure of the product.
We recommend using the connection method shown in the figure below.
Please do not connect in this way as shown in the following figure.
Notice:
- When mounting the load, tighten the load slowly. The torque should not be too large to prevent damage to the mechanism.
- Avoid stretching and bending cables.
- Use the dedicated cable provided by CoreMorrow to connect ZT35H80K and the controller.
- Do not connect via an extension cable casually, if you need a longer cable, please contact CoreMorrow.
5.2 Operation
Please reconfirm the following information before turning on the power:
- The operating environment meets the operating environment requirements of ZT35H80K.
- Connect the wire correctly
- Fixed screws must be tightened.
After the above information is confirmed, relevant controller operations can be carried out:
- Please read the user manual of the controller carefully before operation, and then start the controller.
- Set the controller’ output voltage to zero first.
- Check no abnormal phenomenon, then input voltage value (via keyboard or analog control) according to specified input voltage range.
- Operating normally within the rated voltage range of piezoelectric ceramics (0~120V, maximum 150V).
- After use, please carry out voltage reset operation.
Please take light steps when ZT35H80K in operation, do not knock the product,
so as not to affect the use of the product or even damage the product. The
resolution of the product itself is unlimited, and the resolution depends on
the performance of the controller. In order to achieve better motion precision
of ZT35H80K, it is recommended to use our company’s supporting controller.
Please refer to the user manual of the controller for the specific operation
to ensure correct operation before relevant operation.
Notice: The driving voltage shall not exceed the voltage range of
ZT35H80K(800V). If any abnormal noise or oscillation occurs during use, turn
off the power immediately
and check the parameter setting.
Transportation and inspection
6.1 Transportation
This product is packed in cartons. Transportation is carried out under the
packaging conditions. This product can be transported by various means of
transport under normal circumstances. In the process of transportation, direct
rain and snow, corrosive substances, strong collision, extrusion, irregular
placement and other improper behaviors should be avoided as far as possible.
6.2 Open-Box Inspection
Inspection content:
- Before opening the package, please check the outer packing carefully to see if there is any breakage, wetting, dampness, deformation, etc.
- Please check the completeness of package contents one by one according to the supply contract and packing list.
- Check whether the surface of the product has obvious damage.
- Check whether the product identification is clear and complete.
- Check whether the connector is loose and the connector wire is broken or damaged.
- In case of any of the above, please make a detailed record and take a photo of it.
Meanwhile, please contact us for processing immediately.
Attention:
- Please handle with care when opening the package, so as not to knock against the product and cause permanent damage to it.
- Please do not use heavy tools or rough way to open.
- Please do not discard all the packaging materials which are needed for repair and return.
Maintenance and Treatment
7.1 Problem Handling
FAQ are shown in the table below.
Problem description | Possible reason | Solution |
---|---|---|
No displacement or less displacement | The connection wire is not connected | |
properly or poor contact | Check the connection wire | |
Excessive load | Load according to the product’ s load capacity | |
Sensor zero drift | Check the sensor | |
Low accuracy | Mountingsurface unevenness | Mount the platform on a flat surface |
Loose connection | Fasten connection | |
Wrong connection | Check if the wiring is correct | |
Vibration or inaccurate positioning at startup | Incorrect input control | |
parameters | Stop immediately and check the parameter Settings | |
Resonance occurs | Make drive frequency less than resonance frequency |
If the user cannot solve the problem by himself in the process of using,
please record the problem in detail and contact CoreMorrow, and professional
technical personnel will help to solve. Problems caused by improper operation
are not covered by the warranty. CoreMorrow is not responsible for any
problems caused by dismantling products without permission.
7.2 Daily maintenance
If the product is not used for a long time, please store it in a dust-free,
well-ventilated, clean and non-corrosive indoor environment after packaging.
In the daily maintenance, please do not loosen the bolts on the product
structure, so as not to affect the movement accuracy of the product.
Daily cleaning:
Please disconnect the product from the controller before cleaning the surface
of the product.
When cleaning, gently wipe the surface of the product with a towel dipped in a
small amount of detergent, and then clean it with alcohol. Please do not use
ultrasonic cleaner. When cleaning the surface, try not to pick up the product.
If you have to pick up the product, it is better to put the sponge under the
product for protection. The product should not be too high from the sponge, in
case the product falls off.
7.3 Disposal
Waste products should be disposed according to national and local rules and
regulations. In order to fulfill our responsibility as a product manufacturer,
we will dispose all old equipments on the market in an environmentally
friendly manner.
If you have equipment that cannot be disposed, you can ship it to CoreMorrow.
Address: Building I2, No.191 Xuefu Road, Nangang District, Harbin, HLJ, China
Tel: +86-451-86268790
Customer Service
If you have questions about the products you are currently using, please let
us know the following information:
Product model and relevant number The controller model Software driver version
Computer operating system that installs supporting software
Contact us
Harbin Core Tomorrow Science & Technology Co., Ltd.
Tel: +86-451-86268790
Email: info@coremorrow.com
Website: www.coremorrow.com
Address: Building I2, No.191 Xuefu Road, Nangang
District, Harbin, HLJ, China CoreMorrow Official and CTO WeChat are below:
http://weixin.qq.com/r/PEzawqnEyfS2re2h9xku
https://u.wechat.com/EAOWfcTPsTfQdVIeK41V9hg
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>