LG AG4AH12BWF01 9K Air Conditioner Dualsplit Owner’s Manual

August 19, 2024
LG

LG AG4AH12BWF01 9K Air Conditioner Dualsplit

Product Information

Specifications

  • Model: LG AG4AH12BWF01(9K)
  • Cooling Capacity: 9,000 BTU
  • Energy Efficiency Ratio : 12.5
  • Room Size : Up to 400 square feet
  • Power Supply: 115V/60Hz

Product Usage Instructions

Installation

  1. Choose a suitable location near a power outlet and with proper ventilation.
  2. Unbox the air conditioner and remove all packaging materials.
  3. Install the mounting plate securely on the window frame or wall.
  4. Place the air conditioner unit on the mounting plate and secure it in place.
  5. Connect the exhaust hose and plug in the power cord.

Operation

  1. Turn on the power using the remote control or the control panel on the unit.
  2. Set the desired temperature and fan speed using the controls.
  3. Ensure proper airflow by adjusting the louvers.
  4. Monitor the filter indicator and clean or replace the filter as needed.
  5. Use the timer function to schedule operation as per your requirements.

Maintenance

  1. Regularly clean the air filter to maintain optimal performance.
  2. Inspect the unit for any visible damage or leaks.
  3. Keep the exterior of the unit clean by wiping it with a damp cloth.
  4. Schedule professional maintenance at least once a year for thorough cleaning and inspection.

Frequently Asked Questions (FAQ)

  • How often should I clean the air filter?
    It is recommended to clean the air filter every 2 weeks for optimal performance.

  • Can I use the air conditioner in a room larger than 400 square feet?
    While the unit is designed for rooms up to 400 square feet, it may still provide cooling in slightly larger rooms, although efficiency may be reduced.

  • Why is water dripping from my air conditioner?
    Condensation is a normal byproduct of cooling. Ensure proper installation and tilt of the unit for water drainage.

The function of main control

Time Delay Safety Control

  • 3 min … The compressor is ceased for 3 minutes to balance the pressure in the refrigeration cycle. (Protection of compressor)
  • 2 sec … The indoor fan is ceased for 2 sec. to prevent relay noise. (Protection of fan relay and micro chip)
  • 30 sec … The 4-way valve is ceased for 30 sec. to prevent the refrigerant-gas abnormal noise when the Heating operation is OFF or switched to the other operation mode.

Airflow Direction Control

  • This function is to swing the louver up and down automatically and to set it at the desired position.
  • The procedure is as the following.
    • 1st ; Press the ON/OFF Button to operate the product.
    • 2nd ; Press the Airflow Direction Control Button to swing the louver up and down automatically.
    • 3rd ; Repress the Airflow Direction Control Button to set the louver as the desired position.
Operating Mode Louver Position
Cooling Start

Auto. Swing

| 2

1-4

Heating| Start

Auto. Swing

| 5

3~6

Cooling Mode Operation
When selecting the Cooling Mode Operation, the unit will operate according to the setting by the remote controller and the operation diagram is as following.

Cooling or Heating Mode with Sleep Mode Auto Operation

When selecting the Cooling or the Heating combined with the Sleep Mode Auto Operation , the operation diagram is as following.

Cooling Mode with the Sleep Mode.

  • The setting temperature will be raised by 1 °C 30 minutes later and by 2°C 1 hour later.
  • The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.

Heating Mode with the Sleep Mode.
The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.

Fuzzy Operation

The operation procedure is as following.

If initial mode is decided, that mode is continued despite of the room temperature changing.

Fuzzy Operation for Cooling

Fuzzy Operation for Soft Dry
The Setting temperature will be set to the same that of the current intake-air temperature.

  • Compressor ON temperature; Setting temperature + 1 “C
  • Compressor OFF temperature; Setting temperature -0.5 “C

Fuzzy Operation for Heating

Intake Air temp. Below 20″C Over 20″C~below 21 “C
Setting temp. 20″C Intake air temperature +0.5″C

Heating Mode Operation
The unit will operate according to the setting by the remote controller and the operation diagram is shown as following.

Hot- Start Control

  • The indoor fan stops until the evaporator piping temperature will be reached at 28″C.(BY TEMPE RATURE)
  • The operation diagram is as following.

Deice Control

  • Deicing operation is controlled by timer and sensing the indoor pipe temperature.
  • Temperature difference ,1 T1 of the indoor pipe temperature and the indoor intake air temperature are checked after 25 minutes passed starting of heating operation.(,1 T1)
  • Temperature difference ,1 T2 of the indoor pipe temperature and the indoor intake air temperature are checked after 60 minutes passed starting of heating operation.(,1 T2)
  • Deicing time is controlled by difference ,1 Td of ,1 T1 and ,1 T2.
  • The deicing time and the operation diagram are as following.
,1T1-,1T2=’1Td Over 3.5″C 3.0~3.S”C 2.5~3.0″C 2.0~2.S”C below 2.0″C
Deicing Time 12 mins 11 mins 10 mins 9 mins Heating Operation

Soft Dry Operation

  • During Soft Dry Operation, the compressor ON temperature is the setting temperature plus 1 “C, the compressor OFF temperature is the setting temperature minus 0.5 “C.
  • When the room temperature rises over the compressor ON temperature, the operation mode is switched to the cooling mode.
  • When the room temperature falls between the compressor ON temperature and OFF temperature, the operation mode is switched to the Soft Dry Operation.
  • In this temperature range, 1 0min. Dry Operation, 5.5min operation OFF, 1.5min. only fan operation repeat.
  • During 1 0min Dry operation, even if the room temperature falls below compressor OFF temperature, 10 min(MAX) Compressor ON from starting of Dry operation which includes 4 min. Compressor ON operation below the compressor OFF temperature.
  • In micom dehumidify mode, control of fan speed is as following.

Forced Operation

  • If you lose wireless remote controller, you can operate the unit with forced operation switch.
  • The standard conditions are as following.
     | Cooling Model|
    ---|---|---
    Room Temp 2: 24’C| 21 ‘C :s: Room Temp< 24’C| Room temp< 21 ‘C
    Operation Mode| Cooling| Cooling| Soft Dry| Heating
    FAN Speed| High| High| Low| High
    Setting Temp.| 24°C| 24°C| Room Temp.| 22°C

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals