VIVOSUN 480GPH Fountain Pump User Manual

August 13, 2024
VIVOSUN

VIVOSUN 480GPH Fountain Pump

INTRODUCTION

Our pumps undergo careful inspection and testing to ensure both safety and optimal performance. However, failing to follow the instructions and warnings in this manual may result in damage to the pump or serious injury. Please read this entire instruction manual thoroughly before operating the appliance, and keep it handy for future reference.

Key Safety Points:

  • Completely submerge the pump in water before turning it on.
  • Always unplug the pump before handling it.

Warning

  • Only connect the pump to the voltage specified on its rating label.
  • Do not attempt to pump flammable liquids.
  • The maximum operating depth of this pump is 1.Sm.
  • The power cord cannot be replaced. If the cord is damaged, the appliance should be scrapped immediately.
  • To eliminate the risk of electric shock, do not immerse the plug in water or any other liquid.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.

INSTALLATION

Insert the suction cups or rubber feet into the proper housing in the impeller chamber and motor body, then completely submerge the pump to install.

USE

  • The flow rate can be adjusted with the control valve; the pump will start operating as soon as you plug it in, and will stop operating as soon as you unplug it.

CLEANING

  • Unplug and remove the impeller chamber to separate it from the motor body; take out the impeller and shaft.
  • Then clean all parts with a soft brush.
  • If there are any limestone deposits on any parts, soak them in vinegar for several hours to clean them.
  • Next, reassemble all the parts according to the parts list on the following page; follow the instructions carefully so that the pump can be reassembled in the appropriate order

MAINTENANCE

  • With extended use over time, the plastic bearing, ceramic shaft, and shaft sleeve will naturally wear down.
  • This can result in some ambient noise.
  • When these parts become worn and noisy, they need replacement.
  • To change them out: Unplug the pump’s power cord.
  • Open the impeller chamber. Remove each worn part.
  • Replace with new plastic bearing, ceramic shaft, and/or shaft sleeve as needed.

PARTS LIST

  1. Pump Body
  2. Nozzles x3 (13/16/19mm)
  3. Shaft
  4. Rotor
  5. Impeller Cover
  6. Front Cover
  7. Flow Control Valve
  8. Suction Cups x2

CAUTION

  • The pump should always be completely submerged in water.
  • Do not let the pump run dry.
  • Always disconnect from the electrical outlet before cleaning, performing maintenance, or handling the pump.
  • Do not lift the pump by the power cord.
  • Do not use the pump in liquids exceeding 35°C (95°F).
  • Do not use in salt water.
  • If the plug or receptacle gets wet, do not unplug the cord; instead, disconnect the fuse or circuit breaker that supplies power to the appliance and then unplug and examine the device for presence of water in the receptacle.

PERFORMANCE

  • A clogged or dirty intake screen will greatly reduce performance.
  • If the pump is used on a dirty surface, raise it slightly to reduce the amount of debris in contact with the intake. If less flow is desired, adjust the regulator on the seal cover to restrict the flow.
  • Do not run the pump when it is not submerged in water as it may be damaged.
  • Always submerge the pump first and then plug it into an electrical outlet. The first time the pump is used, it may appear not to be functioning properly because there is still air within the pump. Do not worry – restart the device a few times by unplugging and plugging it in again until all air has been expelled and the unit is operating normally.

IF PUMP STOPS WORKING

  • Double-check the outlet being used, and try another outlet to ensure it is receiving power.
    Note Always unplug the pump before handling it.

  • Check the pump outlet and tubing for kinks and obstructions. Algae can block both, so use a garden hose to flush out any algae.

  • Check the inlet to ensure it is not clogged with debris.

  • Remove the pump inlet to access the impeller area. Turn the rotor to ensure it is not broken or jammed.

  • Performing monthly maintenance on your pump will greatly prolong its lifespan.

Note Ensure that the power cord loops under the outlet to form a “Drip Loop”. This will prevent water from running down the cord and into the outlet.

DISPOSAL

Do not dispose of this product as unsorted municipal waste. Such waste must be collected separately for special treatment.

FREQUENTLY ASKED QUESTIONS

What is the price of the VIVOSUN 480GPH Fountain Pump?

The VIVOSUN 480GPH Fountain Pump is priced at $16.99.

How does the VIVOSUN 480GPH handle water flow?

The VIVOSUN 480GPH Fountain Pump can handle a maximum flow rate of 1800 liters per hour (480 gallons per hour), making it suitable for small to medium-sized fountains and water features.

What is the maximum lifting height of the VIVOSUN 480GPH Fountain Pump?

The VIVOSUN 480GPH Fountain Pump can lift water up to a maximum height of 7.2 feet.

What power source does the VIVOSUN 480GPH Fountain Pump use?

The VIVOSUN 480GPH Fountain Pump operates on AC power, specifically 110 volts.

What are the dimensions of the VIVOSUN 480GPH Fountain Pump?

The VIVOSUN 480GPH Fountain Pump has dimensions of 3.5 inches in length, 2.3 inches in width, and 2.7 inches in height.

What is the wattage of the VIVOSUN 480GPH Fountain Pump?

The VIVOSUN 480GPH Fountain Pump consumes 25 watts of power.

What is the working temperature range for the VIVOSUN 480GPH Fountain Pump?

The VIVOSUN 480GPH Fountain Pump operates within a temperature range of 39℉ to 95℉.

What is the flow rate of the VIVOSUN 480GPH Fountain Pump in gallons per hour?

The VIVOSUN 480GPH Fountain Pump has a maximum flow rate of 480 gallons per hour.

What is the flow rate of the VIVOSUN 480GPH Fountain Pump in liters per hour?

The VIVOSUN 480GPH Fountain Pump has a maximum flow rate of 1800 liters per hour.

How do you maintain the VIVOSUN 480GPH Fountain Pump?

Regular maintenance involves cleaning the pump to prevent clogging, checking for any signs of wear, and ensuring the power source and connections are secure.

Why isn't my VIVOSUN 480GPH Fountain Pump turning on?

Ensure that the VIVOSUN 480GPH Fountain Pump is properly connected to a functioning power outlet. Check the power cord for any visible damage and confirm that the circuit breaker or fuse has not been tripped.

What should I do if the VIVOSUN 480GPH Fountain Pump is not pumping water?

First, inspect the intake of the VIVOSUN 480GPH Fountain Pump for blockages. Clean the intake screen and ensure that the water level is sufficient to fully submerge the pump. Additionally, check the impeller for debris or damage.

Why is the water flow from my VIVOSUN 480GPH Fountain Pump weaker than expected?

A reduced flow rate from the VIVOSUN 480GPH Fountain Pump could be due to a clogged intake or impeller. Clean the intake and impeller, and make sure the pump is fully submerged and free of obstructions.

How can I fix the VIVOSUN 480GPH Fountain Pump if it's making unusual noises?

Unusual noises from the VIVOSUN 480GPH Fountain Pump may indicate trapped air, debris in the impeller, or improper submersion. Ensure the pump is fully submerged, and clean the impeller to remove any debris.

What should I do if the VIVOSUN 480GPH Fountain Pump overheats?

Overheating in the VIVOSUN 480GPH Fountain Pump can occur if the pump is running dry, there is a blockage in the intake, or the water level is too low. Turn off the pump, allow it to cool, and then clean the intake and impeller before restarting.

VIDEO – PRODUCT OVERVIEW

DOWNLOAD THE PDF LINK: VIVOSUN 480GPH Fountain Pump User Manual

REFERENCE:VIVOSUN 480GPH Fountain Pump User Manual- Device.Report

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals