VIVOSUN WP-0001 Diaphragm Water Pump Strainer User Manual

June 21, 2024
VIVOSUN

VIVOSUN WP-0001 Diaphragm Water Pump Strainer

VIVOSUN-WP-0001-Diaphragm-Water-Pump-Strainer-PRO

Thank you for choosing VIVOSUN. We are committed to product quality and friendly customer service. If you have any questions or suggestions, please don’t hesitate to contact us.

PRODUCT DESCRIPTION

This VIVOSUN F33 pump is a diaphragm pump with 3 chambers and a powerful motor drive. It produces an open flow rate of 4 GPM. The high-quality material and refined design enable it to be an excellent choice. Additionally, the pump comes with a variety of easy-to-install connection accessories and filters.

FEATURES

  • Built-In Thermal Protection
    When the motor is overheating, the pump will automatically stop running until the tempera­ture reduces to an appropriate and safe level. Once it reaches this temperature, it will start operating again.

  • Automatic Pressure Switch Control
    This is an automatic diaphragm pump with a pressure switch. It starts automatically when the faucet is switched on and stops working automatically when the faucet is switched off.

  • Pure Copper Motor
    The pump is equipped with a 100% copper motor that has an overload and overheat protec­tion function. When the motor overheats, it can automatically disconnect the power to the electronic circuits. Compared to other models, it has higher performance, less noise, and higher speed, enabling it to operate safely and reliably.

  • Iron Fixing Plate
    The anti-vibration fixing plate at the base can greatly reduce the motor’s noise output. With the galvanized anti-rust treatment on the surface of the plate, it resists corrosion and will not rust easily even in a humid environment.

  • Standard Accessories
    We use the standard 1/2″ thread for easier operation and quicker installation.

PARAMETERS

VIVOSUN-WP-0001-Diaphragm-Water-Pump-Strainer- \(3\)

Installation Display

VIVOSUN-WP-0001-Diaphragm-Water-Pump-Strainer- \(1\)

WIDE APPLICATION
The F33 series AC diaphragm pump is widely used in yachts, RVs, agricultural irrigation, industrial plants, liquid transfers, water purifier boosters, solar water systems, car washes, and more.

OPERATING INSTRUCTIONS

  1. Please make sure the water pump is connected tightly to the inlet and outlet pipes. Several problems may occur such as low pressure, insufficient water suction, and water leakage, etc.
  2. Install a filter at the inlet end. The optimal density of filtration is above 50 mesh.
  3. Connect the power supply to the water pump. The output parameters of the connected power supply must meet the motor’s input requirements.
  4. Turn on the power. The pump will run water for 5-10s, draining water and driving air out of the pipelines. When the water output is stable, turn off the power temporarily and connect the pump to the water gun, faucet, shower, or other similar devices that can supply water.
  5. Turn off the water faucet when it is not in use. The faucet has an automatic pressure control switch. If you turn on the tap once, it will work automatically the next time.

REPAIR KITS

VIVOSUN-WP-0001-Diaphragm-Water-Pump-Strainer- \(2\)

Letter/Number Description Quantity
A Pump Head Assembly 1
B Valve Assembly 1
C Diaphragm Assembly 1
D Motor Assembly 1
1 Pressure Switch 1
2 Diaphragm of Pressure Switch 1
3 Pump Head 1
4 Diaphragm 1
5 Rubber Feet 1
6 Motor 1
7 F4205 Copper Female Connector 1
8 F4206 Copper Male Connector 1
9 Thread Seal Tape 1
10 Water Pipe Clamp 2

TROUBLESHOOTING

VIVOSUN-WP-0001-Diaphragm-Water-Pump-Strainer- \(4\) VIVOSUN-WP-0001-Diaphragm-Water-Pump-Strainer-
\(5\) VIVOSUN-WP-0001-Diaphragm-Water-Pump-
Strainer- \(6\)

CAUTIONS

  1. When the pump is working, it is necessary to ensure smooth drainage to avoid blocking and causing damage to the pressure switch.
  2. If you hear a strange ticking sound from the switch during operation, please turn off the pump immediately and turn up the pressure appropriately.
  3. The motor is slightly waterproof, so don’t worry too much if a bit of water gets on it. We recommend drying it as soon as possible. It is strictly forbidden to immerse the motor in water. If the motor is used outside, it should be protected with a cover to prevent water from contacting the motor and potentially causing power failure, leakage, or motor damage.
  4. The water inlet must have a filter. Impurities in the liquid may block the pump, resulting in a series of problems like lower pressure, lower flow, pump damage, and failure to pump water. It is strictly forbidden to use this pump without connecting the filter. The optimal filter density is more than 50 mesh.
  5. Warning: Please use the 115V AC motor. The use of 220V is prohibited, as it will burn the motor directly.
  6. The pump can convey water, weak acids, alkalis, salts, and other liquids. It is not allowed to convey liquids with particles, gasoline, and other combustible liquids.
  7. The water pump does not support 24-hour continuous work. Intermittent work will help extend the life of the pump. Please turn off the power to the pump when not using the pump for extended periods.
  8. The water pump features an automatic pressure switch to allow you to adjust the pres­sure freely as needed. Avoid the extremes, as too low pressures will result in frequent starting and stopping and even motor burns, whereas too high pressures will cause the pump to shut down abnormally.
  9. After using this pump during a cold winter please drain any excess water as freezing will cause cracks in the water pipes.
  10. The water pump has been tested for performance. Please do not disassemble it by yourself. Check the power supply before use; the power supply parameters must be consistent with the motor pump input parameters.
  11. Proper installation requires placing the pump head down or flat to avoid water leakage into the rotor.

Read User Manual Online (PDF format)