RuiJie RG-ES126S-LP V2 Router Switch Installation Guide
- August 12, 2024
- RuiJie
Table of Contents
RuiJie RG-ES126S-LP V2 Router Switch
Product Information
Specifications
- Product Name: RG-ES126S-LP V2 Switch
- Manufacturer: Ruijie Networks
- Hardware Installation and Reference Guide Version: 2
Product Usage Instructions
Product Overview
The RG-ES126S-LP V2 Switch is a networking device designed for network
engineers, technical support and servicing engineers, and network
administrators. It provides efficient network connectivity and management.
Package Contents
The package includes the RG-ES126S-LP V2 Switch, power adapter,
installation guide, and any other relevant accessories.
Product Appearance
The switch features a sleek and compact design with indicator lights for
power, connectivity, and activity. It has multiple ports for connecting
network devices.
Hardware Installation
Follow these steps for hardware installation
- Choose a suitable location for the switch with proper ventilation.
- Connect the power adapter to the switch and plug it into a power source.
- Connect network devices to the switch using Ethernet cables.
- Power on the switch and ensure all indicator lights are functioning correctly
Troubleshooting
If you encounter any issues with the switch, refer to the hardware
troubleshooting section in the manual or contact technical support for
assistance.
Technical Support
For technical support, visit the official Ruijie Networks website or
contact the technical support team via email or the case portal.
FAQ
-
Q: What should I do if the indicator lights on the switch are not turning on?
- A: Check the power connection and ensure that the switch is receiving power. If the issue persists, contact technical support for further assistance.
-
Q: Can I use the RG-ES126S-LP V2 Switch in a rack-mounted setup?
- A: Yes, the switch can be installed in a standard network equipment rack for centralized management and organization.
RG-ES126S-LP V2 Switch
Hardware Installation and Reference Guide
- Document Version: V1.2
- Date: 2024.01.22
- Copyright © 2024 Ruijie Networks
Copyright
- Copyright © 2024 Ruijie Networks
- All rights are reserved in this document and this statement.
- Any reproduction, excerption, backup, modification, transmission, translation or commercial use of this document or any portion of this document, in any form or by any means, without the prior written consent of Ruijie Networks is prohibited.
- Trademarks including , are owned by Ruijie Networks.
- All other trademarks or registered trademarks mentioned in this document are owned by their respective owners.
Disclaimer
- The products, services, or features you purchase are subject to commercial contracts and terms. Some or all of the products, services or features described in this document may not be within the scope of your purchase or use. Unless otherwise agreed in the contract, Ruijie Networks does not make any express or implied statement or guarantee for the content of this document.
- Due to product version upgrades or other reasons, the content of this document will be updated from time to time. Ruijie Networks reserves the right to modify the content of the document without any notice or prompt.
- This manual is for reference only. Ruijie Networks endeavors to ensure content accuracy and will not shoulder any responsibility for losses and damages caused due to content omissions, inaccuracies or errors.
Preface
Intended Audience
This document is intended for
- Network engineers
- Technical support and servicing engineers
- Network administrators
Technical Support
- Official website of Ruijie Reyee: https://www.ruijienetworks.com/products/reyee
- Technical Support Website: https://ruijienetworks.com/support
- Case Portal : https://caseportal.ruijienetworks.com
- Community : https://community.ruijienetworks.com
- Technical Support Email : service_rj@ruijienetworks.com
Conventions
Signs
The signs used in this document are described as follows:
Danger
An alert that calls attention to safety operation instructions that if not
understood or followed when operating the device can result in physical
injury.
Warning
An alert that calls attention to important rules and information that if not
understood or followed can result in data loss or equipment damage.
Caution
An alert that calls attention to essential information that if not
understood or followed can result in function failure or performance
degradation.
Note
An alert that contains additional or supplementary information that if not
understood or followed will not lead to serious consequences.
Specification
An alert that contains a description of product or version support.
Note
This manual provides the device installation steps, hardware troubleshooting,
module technical specifications, and specifications and usage guidelines for
cables and connectors. It is intended for the users who have some experience
in installing and maintaining network hardware. At the same time, it is
assumed that the users are already familiar with the related terms and
concepts.
Product Overview
- RG-ES126S-LP V2 is a PoE switch with high performance and multiple working modes. The switch provides 24 10/100 Mbps self-adaptive Ethernet RJ45 ports, one 10/100/1000 Mbps self-adaptive Ethernet RJ45 port, and one GE combo port. All ports have line-rate forwarding performance, contributing to greater network flexibility. Featuring highly-integrated design and easy operation, the device is applicable for security monitoring and Wi-Fi hotspots arrangement. RG-ES126S-LP V2 offers a simple, economical, standard, and high-performance network solution to improve work efficiency. The LEDs on the front panel help you to check the operating status of the switch and diagnose the network faults.
- Compliant with IEEE 802.3at and backward compatible with IEEE 802.3af, the 24 100M Ethernet RJ45 ports support PoE power supply. Serving as a PoE device, the switch can automatically identify the powered devices compliant with the standard and supply power for such devices through Ethernet cables. The switch works in standard mode, flow control off mode or VLAN mode. You can switch the working mode by toggling the DIP switch on the front panel. The multiple modes of the switch allow you to expand the home network and office network without being limited by the electric wiring, meeting the networking requirements of small- and medium-sized enterprises, intelligent community, hotels, offices, and campus.
Package Contents
Table 1-1 Package Contents
Item | Quantity |
---|---|
RG-ES126S-LP V2 Switch | 1 |
Rubber Pad | 4 |
Mounting Bracket | 2 |
Power Cord (1.8 m/5.91 ft) | 1 |
M3 x 6 mm Screw | 8 |
Dust Cap | 1 |
User Manual | 1 |
Note
The package contents are subject to the purchase contract. The actual delivery
prevails. Please check the items carefully against the package contents or
purchase contract. If you have any questions or there are any errors, please
contact your distributor.
Product Appearance
The RG-ES126S-LP V2 switch provides 24 10/100 Base-TX self-adaptive Ethernet
ports, one 10/100/1000 Base-TX SFP port, one 1000 Base-TX combo port, one DIP
switch, one system status LED, and other LEDs on the front panel. On the rear
panel of the switch, there is an AC power plug and a grounding stud.
Figure 1-1 Appearance of a RG-ES126S-LP V2 Switch
Front Panel
Table 1-2 Front Panel Specifications
No. | Item | Description |
---|---|---|
1 | System Status LED |
- Off: The switch is not powered on.
- Solid on : The switch is powered on.
2| 10/100Base-TX Link/Act LED|
- Solid green: The port has made a successful 10/100 Mbps link.
- Flashing green : The port is transmitting and receiving data at 10/100 Mbps.
- Solid orange : A 10/100 Mbps link is established on the port.
No. | Item | Description |
---|---|---|
- Blinking orange: The port is receiving and sending data at 10/100 Mbps.
- Off: The port is not connected.
3| PoE Status LED|
- Solid green: PoE is enabled. Flashing green: PoE overload occurs.
- Off: PoE is disabled.
4| 10/100/1000Base-TX Copper Port LED|
- Solid orange: The port has made a successful 10/100 Mbps link.
- Flashing orange : The port is transmitting and receiving data at 10/100 Mbps.
- Solid green: The port has made a successful 1000 Mbps link up.
- Flashing green: The port is transmitting and receiving data at 1000 Mbps.
- Off: The port is not connected.
5| 10/100/1000Base-TX Combo Port LED|
- Solid orange: The port has made a successful 10/100 Mbps link.
- Flashing orange: The port is transmitting and receiving data at 10/100 Mbps.
- Solid green: The port has made a successful 1000 Mbps link.
- Flashing green: The port is transmitting and receiving data at 1000 Mbps.
- Off: The port is not connected.
6| DIP Switch|
- The DIP switch is used to switch the working mode of the device.
- Standard mode: Flow control is enabled and all ports can communicate with each other.
- Flow Control Off mode : Flow control is disabled and all ports can communicate with each other.
- VLAN mode : Ports 1 to 24 cannot communicate with each other but they can communicate with ports 25 and 26.
7| 10/100Base-TX Self-adaptive Ethernet Ports| 24 10/100 Mbps self-adaptive
Ethernet RJ45 ports (Auto MDI/MDIX) support PoE power supply.
8| 10/100/1000Base-TX Self- adaptive Ethernet Port| One 10/100/1000 Mbps self-
adaptive Ethernet RJ45 port (Auto MDI/MDIX).
No.| Item| Description
---|---|---
9| 10/100/1000Base-X Combo Port| One 10/100/1000Base-T combo port. The SFP
port and the copper port cannot be used at the same time.
Rear Panel
Table 1-3 Rear Panel Specifications
No. | Item | Description |
---|---|---|
1 | Grounding Stud | Connect the grounding stud to the protection ground with |
the grounding cable to provide grounding protection.
2| Nameplate| Nameplate on the bottom of the device
3| AC Input Plug| Connect the power cord to the AC input plug to power on the
switch.
Technical Specifications
Table 1-4 Technical Specifications of a RG-ES126S-LP V2 Switch
Model | RG-ES126S-LP V2 |
---|---|
Service Ports |
- 24 10/100 Mbps self-adaptive Ethernet ports (supporting Auto MDI/MDIX)
- One 10/100/1000 Mbps self-adaptive Ethernet port (supporting Auto MDI/MDIX) One 1000 Mbps combo port
- Ports 1-24 support PoE power supply.
Power Supply| AC input
Rated voltage range: 100 V AC to 240 V AC Maximum voltage range: 90 V AC to
264 V AC Frequency: 50 Hz/60 Hz
| Rated current: 1.5 A
---|---
EEE| Disabled by default
PoE|
- IEEE 802.3af-compliant and 802.3at-compliant Ports 1-24 support PoE power supply.
- Maximum PoE output power per port: 30 W
- Maximum PoE output power per device: 180 W
PoE Power Cable Pairs| Mode A (1-2, 3-6 pairs)
Maximum Power Consumption| 209 W
Working Mode
|
- Standard mode: Flow control is enabled and all ports can communicate with each other.
- Flow Control Off mode: Flow control is disabled and all ports can communicate with each other.
- VLAN mode: Ports 1 to 24 cannot communicate with each other but they can communicate with ports 25 and 26.
Operating Temperature| 0°C to 45°C (32°F to 113°F)
Storage Temperature| –40ºC to 70ºC (–40ºF to 158ºF)
Operating Humidity| 10% to 90% RH (non-condensing)
Storage Humidity| 5% to 90% RH (non-condensing)
Lightning Protection (Port Surge)| 6 KV
Fan| Two fans
Airflow Direction| Left-to-right airflow
Certification| CE
Ground Leakage Current| ≤ 3.5 mA
Dimensions
(W x D x H)
| 440 mm x 208 mm x 44 mm (17.32 in. x 8.19 in. x 1.73 in.)
Weight| 3.35 kg (7.39 lbs, with packaging materials)
Warning
- RG-ES126S-LP V2 switch is a Class A product. The device may cause radio interference in the living environment. You are advised to take proper measures.
- You are advised to keep the device out of the reach of children.
Cooling
The RG-ES126S-LP V2 switch adopts fan cooling design. To ensure the normal
operation of the device, maintain a minimum clearance of 10 cm (3.94 in.)
around the device. Dust the device every three months to avoid blocking the
ventilation openings.
Preparing for Installation
Safety Precautions
Note
- To avoid device damage and physical injury, please read the safety precautions carefully before installing the device.
- The following safety precautions may not cover all possible dangers.
General Safety Precautions
- Install the device in a standard 19-inch cabinet.
- Do not place the device in a wet position, and keep the device away from liquid. Keep the chassis clean and dust-free.
- Place the device away from heat sources.
- Make sure that the cabinet and the power distribution system are properly grounded.
- Do not place the device in walking areas.
- Do not wear loose clothes, ornaments, or other items that may be hooked by the chassis during installation and maintenance.
- Keep the tools and components away from walking areas.
Handling Safety
- Avoid handling the device frequently after installation.
- Cut off all power supplies and unplug all power cords before moving and handling the device.
- Do not handle the device alone. At least two persons are needed. Keep balance and prevent personal injuries when handling the device.
Electric Safety
Warning
-
Improper or incorrect electric operations may cause a fire, electric shock, and other accidents, and lead to severe and fatal personal injury and device damage.
-
Direct or indirect contact with high voltage or mains supply through wet objects may cause fatal dangers.
-
Observe local rules and regulations when performing electric operations. Only personnel with relevant qualifications can perform such operations.
-
Check whether there are potential risks in the work area. For example, check whether the power supply is grounded, whether the grounding is reliable, and whether the ground is wet.
-
Learn about the position of the indoor emergency power switch before installation. Cut off the power switch in case of accidents.
-
Check the device carefully before shutting down the power supply.
-
Select a correct leakage protector (also referred to as “leakage current switch” or “leakage current breaker”) for the power supply system. When there is a risk of leakage and electric shock, the power supply is automatically disconnected. A correct leakage protector should meet the following requirements:
-
The rated leakage action current of each leakage protector is greater than twice of the theoretical maximum leakage current of all the power supplies in the system. For example, if a system is equipped with16 identical power supplies, the leakage current of each power supply is equal to or less than 3.5 mA, and the leakage current of the system totals 56 mA. A leakage protector with 30 mA rated action current supports less than five power supplies (that is, Action current of the leakage protector/2/Maximum leakage current of each power supply = 30/2/3 .5 ≈ 4.28). In other words, the leakage protector with 30 mA rated action current supports no more than four power supplies. In this case, the 16 power supplies in the system require at least four leakage protectors with 30 mA rated action current and each leakage protector supports four power supplies.
If power supplies in a system differ in models, the rated leakage action current of each leakage protector divided by two is greater than the sum of maximum leakage currents of all the power supplies. -
The rated leakage non-action current of a leakage protector shall be 50% of the leakage action current. Take a leakage protector with 30 mA rated leakage action current as an example. The rated leakage non-action current shall be 15 mA. When the leakage current is below 15 mA, the protector shall not act.
-
Caution
To guarantee personal safety, the rated leakage action current of each leakage
protector in the system must be equal to or less than 30 mA (human body safety
current is 30 mA). When twice of the total leakage current of the system is
greater than 30 mA, the system must be equipped with two or more leakage
protectors.
For the leakage current value, see Section 1.3 Technical Specifications.
Electrostatic Discharge Safety
- Ensure that the device is properly grounded.
- Keep the indoor installation environment free of dust.
- Maintain proper humidity conditions in the installation environment.
- Before installing various pluggable modules, please wear an anti-static wrist strap and ensure that the anti-static wrist strip is properly grounded.
Installation Environment Requirements
The device must be installed indoors. To ensure its normal operation and
prolonged service life, the installation site must meet the following
requirements.
Bearing Requirements
Evaluate the weight of the switch and its accessories (for example, the
cabinet, chassis, and power supply modules), and ensure that the ground of the
installation site meets the requirements.
Ventilation Requirements
Maintain a proper clearance around the device for air circulation and normal
heat dissipation. After various cables are connected, bundle the cables or
place them in the cable management bracket to avoid blocking air inlets.
Space Requirements
- It is recommended that the width of the equipment room corridor be greater than 0.8 m (31.50 in.) to ensure enough space for chassis handling and module maintenance.
- Please do not install the device against the wall. Instead, maintain a minimum clearance of 0.4 m (15.75 in.) around the device for heat dissipation and device maintenance.
Temperature/Humidity Requirements
To ensure the normal operation and prolonged service life of the device,
maintain an appropriate temperature and humidity in the equipment room.
The equipment room with too high or too low temperature and humidity for a
long period may cause damage to the device.
- In an environment with high relative humidity, the insulating material may have poor insulation or even leak electricity.
- In an environment with low relative humidity, the insulating strip may dry and shrink, loosening screws.
- In a dry environment, static electricity is prone to occur and damage the internal circuits of the device.
- Too high temperatures can accelerate the aging of insulation materials, greatly reducing the reliability of the device and severely affecting its service life.
Note
The ambient temperature and humidity of the device are measured at the point
that is 1.5 m (59.06 in.) above the floor and 0.4 m (15.75 in.) before the
device rack when there is no protective plate in front or at the back of the
rack.
Cleanliness Requirements
Dust poses a major threat to the device. The indoor dust takes on a positive
or negative static electric charge when falling on the device, causing poor
contact of the metallic joint. Such electrostatic adhesion may occur more
easily when the relative humidity is low, not only affecting the service life
of the device, but also causing communication faults. The following table
describes the requirements for the dust content and granularity in the server
room.
Table 2-1 Requirements for Dust
Dust | Unit | Content |
---|---|---|
Dust particles (diameter ≥ 0.5 μm) | Particles/m3 | ≤ 3.5 × 106 |
Dust particles (diameter ≥ 5 μm) | Particles/m3 | ≤ 3.5 × 104 |
Apart from dust, the salt, acid, and sulfide in the air in the server room must meet strict requirements. These harmful substances will accelerate metal corrosion and component aging. Therefore, the equipment room should be properly protected against the intrusion of harmful gases, such as sulfur dioxide, hydrogen sulfide, nitrogen dioxide, and chlorine gas. The following table lists limit values for harmful gases.
Table 2-2 Requirements for Gases
Gas | Average (mg/m 3 ) | Maximum (mg/m 3 ) |
---|---|---|
Sulfur dioxide (SO2) | 0.3 | 1.0 |
Hydrogen sulfide (H2S) | 0.1 | 0.5 |
Nitrogen dioxide (NO2) | 0.5 | 1.0 |
Chlorine gas (CI2) | 0.1 | 0.3 |
Note
Average refers to the average value of harmful gases measured in one
week. Maximum refers to the upper limit of harmful gases measured in one week,
and the maximum value lasts up to 30 minutes every day.
Grounding Requirements
A proper grounding system is the basis for stable and reliable running and is
indispensable for preventing lightning strikes and interference. Carefully
check the grounding conditions at the installation site according to the
grounding specifications, and complete grounding properly based on the actual
situation.
Safety Grounding
Ensure that the cabinet and power distribution device are properly grounded
when the device uses the AC power supply. Otherwise, electric shock may occur
when the insulation resistance between the power supply inside the device and
the chassis becomes small.
Caution
-
Please adopt protection grounding connections in buildings so that the device can be connected to the protection ground.
-
Check whether the AC socket is reliably connected to the protection ground of the building. If not, a protection ground wire should be used to connect the protection ground lug of the AC socket to the protection ground of the building.
-
The cross-sectional area of the protection ground cable should be at least 0.75 mm2 (18 AWG).
-
Lightning Grounding
The lightning protection system of facilities is standalone, and is composed of a lightning rod, a lower conductor, and a connector connected to the grounding system. The grounding system is usually used for power reference grounding and safety grounding of the cabinet. Lightning grounding is required only for facilities and is not required for the device. -
EMC Grounding
Grounding required for electromagnetic compatibility (EMC) includes shielded grounding, filter grounding, noise and interference suppression, and level reference, which contribute to the overall grounding requirements. The grounding resistance should be less than 1 ohm, and the grounding lugs of the cabinet should be grounded before the running of the device.
Anti-interference Requirements
- Take interference prevention measures for the power supply system.
- Keep the device away from the grounding equipment or lightning and grounding equipment of the power device as much as possible.
- Keep the device far away from high-frequency current devices such as high-power radio transmitting station and radar transmitting station.
- To connect to the network, 100-ohm Cat5 or higher shielded twisted pair (STP) cables with an RJ45 connector are recommended.
Lightning Protection Requirements
The device can guard against lightning strikes. As an electric device, it may
still be damaged by strong lightning strikes. Take the following lightning
protection measures
- Ensure that the grounding cable of the rack is in good contact with the ground.
- Ensure that the neutral point of the AC power socket is in good contact with the ground.
- You are advised to install a power lightning arrester in front of the power input end to enhance the lightning prevention for the power supply.
Installation Site Requirement
Regardless of whether the device is installed into a rack or on a workbench,
the following conditions must be met
- Maintain a proper clearance around the air inlets and ventilation openings for heat dissipation.
- The device is equipped with two cooling fans. Cold air is drawn through the ventilation openings around the chassis and exhausted from the rear of the chassis through the fans. Thus, maintain a minimum clearance of 15 cm (5.90 in.) around the device to ensure normal heat dissipation. You are advised to install the device in a standard 19-inch rack. If not, you can place the device on a clean workbench. If the installation area is hot, air conditioning is recommended.
- Ensure that the rack and workbench have proper ventilation and heat dissipation.
- Ensure that the rack and workbench are sturdy enough to support the weight of the device and its accessories.
- Ensure that the rack and workbench are properly grounded.
Rack Installation Requirements
If you want to install the device into a rack, confirm that the rack meets the
following requirements
- Please use a standard 19-inch rack with four columns.
- The distance between square hole strips on the left and right sides of the standard 19-inch rack is 465 mm (18.31 in.).
- The distance between the square hole strip on the rack column and the outer side of the front cabinet door is greater than 180 mm (7.09 in.) and the thickness of the front cabinet door is less than 25 mm (0.98 in.). Therefore, the available space is greater than 155 mm (6.10 in.). The rack depth (the distance between the front and rear doors) is greater than 1000 mm (39.37 in.).
- The slide rails (or trays) of the rack meet the bearing requirements of the device.
- A grounding lug is installed properly on the rack to ensure that the device is fully grounded.
- The rack is well ventilated and the porosity of the front and rear panels is greater than 50%.
Tools
Table 2-3 Tools
Common Tools| Phillips screwdrivers, power cords, Ethernet cables,
fastening bolts, diagonal pliers, and binding straps
---|---
Special Tools| Antistatic gloves, wire stripper, crimping pliers,
crystal connector crimping pliers, and wire cutter
Meter| Multimeter
Relevant Devices| PC, display, and keyboard
Note
The RG-ES126S-LP V2 switch is delivered without a tool kit. The tool kit is
customer-supplied.
Installing the Switch
Caution
Ensure that requirements in Chapter 2 are all met.
Before You Begin
- The installation site provides sufficient space for heat dissipation.
- The installation site meets the temperature and humidity requirements of the device.
- The power supply and required current are available in the installation site.
- The Ethernet cables have been deployed in the installation site.
- The selected power supply modules meet the system power requirements.
- The position of the indoor emergency power switch is learned before installation. The power switch is cut off first in case of accidents.
Precautions
To ensure the normal operation and prolonged service life of the device,
please observe the following precautions.
- Do not power on the device during installation.
- Install the device in a well-ventilated position.
- Do not subject the device to high temperatures.
- Keep away from high voltage cables.
- Install the device indoors.
- Do not expose the device in a thunderstorm or strong electric field.
- Keep the device clean and dust-free.
- Cut off the power supply before cleaning the device.
- Do not wipe the device with a damp cloth.
- Do not wash the device with liquid.
- Do not open the enclosure when the device is working.
- Fasten the device tightly.
Mounting the Switch
The RG-ES126S-LP V2 switch can be installed in a 19-inch EIA rack. Install
the switch into the rack by using the delivered accessories.
Rack Installation Requirements
- Before installing the rack, plan the available space for the rack. Reserve sufficient space for the front and rear doors of the rack for device maintenance.
- Mount and fasten the rack at the designed location as planned.
- Install the appropriate cable management bracket and cables.
- Install the tray and fiber termination box on the rack according to the number of switches in the rack.
Mounting the Switch in a Rack
- Take out the two L-shaped brackets and eight M3 x 6 mm screws from the packing materials. Secure a bracket to each side of the switch by using four screws.
- Position the mounting brackets at the desired level on the rack and mark the positions. Install cage nuts into the positions. Gently push the switch along the guide rail into the rack and use the provided screws to fasten the mounting brackets to the cage nuts on the square hole strips of the rack.
Mounting the Switch on a Workbench
If a standard 19-inch cabinet is unavailable, you can mount the device on a
clean workbench
- Attach the four rubber pads to the four recessed areas on the bottom of the switch.
- Place the switch on the workbench to ensure adequate airflow around the switch.
Grounding the Switch
Connect the grounding cable to the grounding stud on the back panel of the
device.
Note
The grounding cable is not delivered with the switch and should be purchased
separately.
Connecting the Cables
Warning
Please use the power cord delivered with the device to prevent accidents.
After installing the device in the rack, connect the switch to the external interfaces with Ethernet cables. Please follow the steps.
- Connect one end of the provided power cord to the system power plug.
- Turn off the main power supply and connect the other end of the power cord to the power socket.
- To connect to the network, 100-ohm Cat5 or higher shielded twisted pair (STP) cables with an RJ45 connector are recommended.
Checking after Installation
- Verify that the grounding cable is properly connected.
- Verify that the cables and power cord are properly connected.
- Verify that the cables are routed indoors. If not, check whether the power supply and interfaces are protected from lightning strikes.
- Verify that a minimum clearance of 10 cm (3.94 in.) is maintained around the device for air circulation.
Verifying Operating Status
Powering on the Switch
Checklist before Power-on
- Check whether the switch is properly grounded.
- Check whether the switch is properly installed in the rack.
- Check whether the power cord is properly connected.
- Check whether the power supply voltage meets the requirements.
- Check whether the Ethernet cable is properly connected, whether the client (may be PC) is started, and whether configuration parameters are set.
Checklist after Power-on
- Check whether the fiber-optic cable and Ethernet cable are properly connected.
- Check the LED status.
Appendix
Connectors and Media
1000BASE-T/100BASE-TX/10BASE-T
-
The 1000BASE-T/100BASE-TX/10BASE-T is a 10/100/1000 Mbps self-adaptive Ethernet port that supports auto MDI/MDIX Crossover.
1000BASE-T complies with the IEEE 802.3ab standard. The cable needs to be a 100-ohm Cat 5 or higher shielded twisted pair (STP) cables which support a maximum transmission distance of 100 meters. -
The 1000BASE-T port uses four pairs of wires for data transmission, all of which must be connected. Figure 5-1 shows the connection of twisted pairs used by a 1000 Base-T port.
In addition to the above cables, 10BASE-T uses Category 3, 4, 5 100-ohm UTP/STP and 100BASE-T uses Category 5 100-ohm UTP/STP for connections. Both support a maximum length of 100 meters (328 ft). Figure 5-2 shows 100BASE- TX/10BASE-T pin assignments.
Figure 5-2 100BASE-TX/10BASE-T Pin Assignments
Fiber-Optic Cable Connection
Please choose SMF or MMF optic cables according to the module types.
Mini-GBIC and SFP Modules
We provide GE SFP modules (Mini-GBIC modules) according to the SFP port types.
You can select the module to fit your specific needs. The following models and
technical specifications of some GE SFP modules are listed for your reference.
Table 5-1 Models and Specifications of Mini-GBIC (SFP) Transceiver Module
Mini-GBIC (SFP)| Wave- length (nm)| Fiber Type| Core Size (μm)| Modular Bandwidth (MHz/km)| Cabling Distance| Max Transmit Power (dbm)| MaX Receive
Power (dbm)
| Standard
---|---|---|---|---|---|---|---|---
FE-SFP- LX- MM1310| 1310| MMF| 62.5/
125
| N/A| 2 km| -14| -14|
FE-SFP- LH15-| 1310| SMF| 9/125| N/A| 15 km| -8| -8|
SM1310| | | | | | | |
| | | 62.5| 160| 220 m| | |
Mini-GBIC- SX
| ****
850
| ****
MMF
| 62.5
50.0
| 200
400
| 275 m
500 m
| ****
-4
| ****
-17
|
| | | 50.0| 500| 550 m| | |
Mini-GBIC-| 1310| SMF| 9/10| N/A| 10 km| -3| -20|
LX|
| | | 62.5| 160| 220 m| | | IEEE
SFP-MM850
| 850| MMF| 62.5
50.0
| 200
400
| 275 m
500 m
| -4| -17| 802.3
| | | 50.0| 500| 550 m| | |
SFP-| 1310| SMF| 9/10| N/A| 10 km| -3| -20|
SM1310|
Mini-GBIC-| 1310| SMF| 9/125| N/A| 40 km| 3| -3|
LH40|
Mini-GBIC-| | | | | 50 km| 0| -22|
ZX50| | | | |
Mini-GBIC- ZX80| 1550| SMF| N/A| N/A| 80 km| 4.7| -22|
Mini-GBIC-| | | | | 100 km| 5| -9|
ZX100| | | | |
Mini-GBIC- GT| N/A| CAT 5 UTP| N/A| N/A| 100 m| N/A| N/A|
Lightning Protection
Installing AC Power Arrester (lightning protection cable row)
The AC power port must be connected to an external lightning protection power
strip to prevent the switch from being struck by lightning when the AC power
cord is introduced from the outdoor and directly connected to the power port
of the switch. The lightning protection power strip can be fixed on the
cabinet, workbench, or wall in the equipment room by using cable ties and
screws. AC power enters the lightening protection power strip and then gets to
the switch.
Figure 5-5 Power Arrester
Caution
The power arrester is not delivered with the switch. Please purchase it based
on actual requirements.
Precautions for installation
- Make sure that the PE terminal of the power arrester has been well-grounded;
- After the switch AC power plug is connected to the socket of the power arrester (lightning protection cable row), lightning protection function implements if the RUN LED is Green and the ALARM LED is OFF.
- If the ALARM LED on the power arrester is Red, check whether it is caused by poor grounding connection or by the reversed connection of the Null and Live lines: Use a multimeter to measure the polarity of the power socket for the arrester when the LED is Red, if the N line is on the left and the L line is on the right (facing the socket), the arrester PE terminal is not grounded; if the L line is on the left and the N line is on the right, the polarity of the arrester power cord should be reversed. In this case, open the power arrester and rectify the polarity of the connection. If the LED is still Red, the arrester PE terminal has not been grounded.
Installing the Ethernet Port Arrester
Please connect an Ethernet port arrester to the switch to prevent the damage
by lightning before connecting an outdoor network cable to the switch.
Tools: Phillips screwdrivers or flat-head screwdriver, multimeter, and diagonal pliers
Installation Steps
- Tear one side of the protective paper for the double-sided adhesive tape and paste the tape to the housing of the Ethernet port arrester. Tear the other side of the protective paper for the double-sided adhesive tape and paste the Ethernet port arrester to the switch housing. The paste position for the Ethernet port arrester should be as close to the ground terminal of the switch as possible.
- Based on the distance between the switch grounding stud and the Ethernet port arrester, cut the grounding cable for the Ethernet port arrester and firmly tighten the grounding cable to the grounding stud of the switch.
- Use a multimeter to check whether the grounding cable for the arrester is in good contact with the grounding stud and the housing of the switch.
- Connect the arrester by using an adapter cable (note that the external Ethernet cable is connected to the IN end, while the adapter cable connected to the switch is connected to the OUT end) and observe whether the LED on the borad is normal or not.
- Use a nylon cable tie to bundle the power cords.
Caution
- The Ethernet port arrester is only for the 10/100M copper Ethernet ports with the RJ-45 connector
- The Ethernet port arrester is not delivered with the switch. Please purchase it based on actual requirements.
During the actual installation, pay attention to the following items
- Reversed installation direction of the arrester. Connect the external Ethernet cable to the IN end and connect the Ethernet port of the switch to the OUT end.
- Poor grounding of the arrester. The grounding cable of the arrester should be as short as possible to ensure that it is in good contact with the grounding stud of the switch. Use a multimeter to confirm the contact condition after the grounding.
- Incomplete arrester installation. If there is more than one port connected to the peer device on the switch, arresters need to be installed on all connection ports for the purpose of lightning protection.