Ruijie RG-RAP2260 Reyee Access Point User Guide

June 4, 2024
RuiJie

Table of Contents

Ruijie RG-RAP2260 Reyee Access Point

Ruijie RG-RAP2260 Reyee Access Point featured

Copyright statement
Ruijie Networks2021
Ruijie Networks reserves all copyrights of this document. Any reproduction, excerption, backup, modification, transmission, translation or commercial use of this document or any portion of this document, in any form or by any means, without the prior written consent of Ruijie Networks is prohibited.

Exemption statement
This document is provided “as is”. The contents of this document are subject to change without any notice. Please obtain the latest information through the Ruijie Networks website. Ruijie Networks endeavors to ensure content accuracy and will not shoulder any responsibility for losses and damages caused due to content omissions, inaccuracies or errors.

Obtaining Technical Assistance

Related Documents

Documents Description

Configuration Guide

| Describes network protocols and related mechanisms that supported by the product, with configuration examples.


Command Reference

| Describes the related configuration commands, including command modes, parameter descriptions, usage guides, and related examples.

Documentation Conventions

The symbols used in this document are described as below

This symbol brings your attention to some helpful suggestions and references. This symbol means that you must be extremely careful not to do some things that may damage the device or cause data loss

Product Overview

Featuring leading 802.11ax and MU-MIMO, Ruijie RG-RAP2260(G) supports 2 spatial streams and delivers up to 574Mbps at 2.4G and 1201Mbps at 5G. The overall dual-radio dual-band performance speeds up to 1.775Gbps per device, totally eliminating Gigabit wireless bottlenecks. RG-RAP2260(G) adopts either local power supply or PoE+ power supply, and can be ceiling-mounted in indoor Wi-Fi coverage scenarios with large areas. RG-RAP2260(G) provides two Gigabit Ethernet ports, making it possible to connect a camera or switch device to adapt to challenges in a wide variety of deployment scenarios.

Technical Specifications

RG-RAP2260(G) Technical Specifications
Model RG-RAP2260(G)
RF Dual-band and dual-radio

Transmission

Protocol

|

Support concurrent 802.11ax, 802.11ac wave2/wave1 and 802.11a/b/g/n.

Operating Bands

| 802.11b/g/n/ax: 2.4 GHz to 2.4835 GHz

802.11a/n/ac/ax: 5.15 GHz to 5.35 GHz, 5.725 GHz to 5.85 GHz

Antenna| Array antenna 2.4G: 3dBi, 5G: 3dBi
Spatial Streams| 2.4G: 2 x 2 MIMO

5G: 2 x 2 MIMO

Max Throughput| 2.4G: up to 574 Mbps 5G: up to 1201 Mbps

Up to 1.775 Gbps per AP

Modulation| OFDM: BPSK6/9Mbps, QPSK12/18Mbps, 16QAM24Mbps, 64QAM48/54Mbps DSSS: DBPSK1Mbps, DQPSK2Mbps, CCK5.5/11Mbps

MIMO-OFDM: BPSK, QPSK, 16QAM, 64QAM, 256QAM, 1024QAM

OFDMA

Receive Sensitivity| 11b: -96dBm(1Mbps), -93dBm(5Mbps), 89dBm(11Mbps)

11a/g: -91dBm(6Mbps), -85dBm(24Mbps), 80dBm(36Mbps), -74dBm(54Mbps) 11n: 90dBm(MCS0), -70dBm(MCS7), -89dBm(MCS8), 68dBm(MCS15)

11ac: 20MHz: 88dBm(MCS0), 63dBm(MCS9)

11ac: 40MHz: 85dBm(MCS0), 60dBm(MCS9)

11ac: 80MHz: 85dBm(MCS0), 60dBm(MCS9)

11ax: 80MHz: -82dBm(MCS0), -57dBm(MCS9), -52dBm(MCS11)

Transmit Power| ≤100mw (20 dBm) (adjustable)
Transmit Power

Adjustment

|

1 dBm

Dimensions

W x D x H

|

194 mm x 194 mm x 35 mm 7.6 in. x 7.6 in. x 1.4 in excluding brackets

Weight| 0.56 kg excluding brackets
Service Ports|

Management Ports N/A
LED 1 LED green
Power Supply Adapter: DC 12 V/1.5 A optional

PoE: IEEE 802.3at

compliant (compatible).

Power Consumption| < 15.3W
Bluetooth 5.0| Support

Temperature

| Operating: 0°C to 40°C (32°F to 104°F)
Storage: –40°C to 70°C –40°F to 158°F

Humidity

| Operating: 5% to 95% RH

non

condensing

Storage: 5% to 95% RH (non-condensing)
Installation| Ceiling/wall mounting

Safety Standards

| GB4943

IEC 60950-1

EMC Standards

| GB9254 EN301 489 EN50155

EN50121

Mechanical

Vibration

|

IEC61373

Radio

| China Radio Transmission Equipment Type Approval Certificate EN300 328

EN301 893

MTBF| > 400,000 H

Hardware Installation and Reference Guide

Weight refers to the weight of host.

Product Image

The AP provides two 10/100/1000Base-T Ethernet ports (LAN1/PoE port is PoE+-capable), one power port for an external power supply and one reset button.

Appearance of RG-RAP2260(G)

Ruijie RG-RAP2260 Reyee Access Point featured

LED Indicator and Button

LED Indicator

and Button

| State| Frequency| Meaning
---|---|---|---






LED Indicator

| Off| N/A| The AP is NOT receiving power.
Blinking| 0.5Hz| Normal operation, but there are alarms.
Fast blinking| 10Hz| Possible cases:

Restoring the factory settings

Upgrading the firmware

Restoring the image file

Initializing the device

Solid green| N/A| Normal operation.


Reset Button

| Press for less than 2 seconds| Restart the device.
Press for more than 5 seconds| Restore the factory settings.

Power Sources

The AP can be powered either with a power adapter or through Power over Ethernet (PoE).

  • Use DC power adapters with specifications recommended by Ruijie.
  • The power adapter is customer-supplied.
  • To use a PoE device, make sure that it supports the IEEE 802.3at standard.

Cooling Solution

The AP features a fanless design

Leave sufficient space surrounding the AP when installing the AP to permit proper airflow for ventilation.

Preparing for Installation

  • To prevent device damage and physical injury.
  • Recommendations do not cover all possible hazardous situations.

Installation

The AP must be installed indoors. To ensure normal operation, the installation site must meet the following requirements.

  • Install the AP in a well-ventilated environment. If it is installed in a closed room, make sure there is a good cooling system.
  • Make sure the site is sturdy enough to support the AP and its accessories.
  • Make sure the site has enough space for installing the AP and leave sufficient room around the AP for ventilation.
  • Do not expose the AP to high temperature, dust, or harmful gases.
  • Do not install the AP in an area prone to fire or explosions.
  • Keep the AP away from EMI sources such as large radar stations, radio stations, and substations.
  • Do not subject the AP to unstable voltage, vibration, and noises.
  • Keep the AP at least 500 meters away from the ocean and do not face it towards the sea breeze.
  • The installation site should be free from water including possible flooding, seepage, dripping, or condensation.
  • The installation site should be selected according to network planning and communications equipment features, and considerations such as climate, hydrology, geology, earthquake, electrical power, and transportation.

Movement

  • Avoid frequently moving the device.
  • Turn off all power supplies and unplug all power cables before you remove the device.

EMI

  • Please observe local regulations and specifications when performing electrical operations.
  • Relevant operators must be qualified.
  • Carefully check for any potential hazards in the working area such as damp/wet ground or floors.
  • Find the location of the emergency power supply switch in the room before installation.
  • Cut off the power supply first in case of an accident.
  • Be sure to make a careful check before shutting down the power supply.
  • Do not place the device in a damp/wet location. Do not let any liquid enter the chassis.
  • Keep the AP far away from grounding or lightning protection devices for power equipment.
  • Keep the AP away from radio stations, radar stations, high-frequency high-current devices, and microwave ovens.
  • Any nonstandard and inaccurate electrical operation can cause an accident such as fire or electric shock, thus causing severe even fatal damages to humans and devices.
  • Direct or indirect contact with a wet object (or your finger) on the high voltage and power line can be fatal.

Ventilation

For proper ventilation, leave sufficient space around the AP.

Temperature and Humidity

To ensure the normal operation and equipment service life, maintain appropriate temperature and humidity levels in the equipment room. Improper room temperature and humidity can cause damage to the device.

  • High relative humidity may affect insulation materials, resulting in poor insulation and even electrical leakage.
  • Sometimes it may lead to changes in the mechanical properties of materials and corrosion of metal parts.
  • Low relative humidity can dry and shrink insulation sheets and cause static electricity that can damage the circuitry.
  • High temperatures greatly reduce device reliability and shorten service life.
Required Temperature and Humidity for the RG-RAP2260(G)
Temperature Relative Humidity
0ºC to 40ºC 32°F to 104°F 5% to 95%

Cleanness

Maximum diameter μm 0.5 1 3 5

Maximum concentration

Particles/m 3

|

1.4×107

|

7×105

|

2.4×105

|

1.3×105

Dust poses a serious threat to device operation. Dust on the surface of the device can be absorbed onto metal contact points by static electricity causing poor contact. Electrostatic absorption of dust occurs more easily when the relative humidity is low, and might shorten the equipment service life and cause communication failures the maximum concentration and diameter of dust allowed in the equipment room.

Gas Average mg/m 3 Maximum mg/m 3
SO2 0.2 1.5
H2S 0.006 0.03
NO2 0.04 0.15
NH3 0.05 0.15
Cl2 0.01 0.3

The amount of salt, acids and sulfides in the air are also strictly limited for the equipment room. These substances can accelerate metal corrosion and aging of some parts. Table 2-3 describes the limits of some hazardous gases such as SO2, H2S, NO2 and Cl2 in the equipment room.

Power Supply

  • DC power adapter:
  • Input voltage: 12V
  • Rated current: 1.5A
  • PoE+ injector: IEEE 802.3at compliant

Inner Diameter

|

Outer Diameter

|

Insertion Depth

|

Conductor Impedance

|

Voltage

endu rance Impedance

| Voltage endu rance Insulator and

Conductor

|

Polarity

---|---|---|---|---|---|---

2.10+/-0.05mm

|

5.50+/-0.05mm

|

9mm

|

|

100MΩ

|

1000V

| Inner                 pole: positive

Outer                 pole:

negative

Technical Specifications of the DC Connector

The DC input power should be greater than the power actually consumed by the system. Use DC power adapters with specifications recommended by Ruijie. Please use Ruijie certified PoE injectors.

Installation Tools

Common Tools| Phillips (crosshead) screwdriver, copper and fiber cables, bolts, diagonal pliers, cable ties
---|---
Special Tools| Wire stripper, crimping pliers, RJ-45 crimping pliers, punch down tool
Meter| Multimeter, bit error rate tester BERT

The tools listed above are customer supplied.

Unpacking the Access Point

Package Contents



Items

| Verify that all parts are installed and debugged. Screws

Mounting brackets

Product quick installation guide

Q.C. certificate

---|---

The above listed items are for general situations, and contents may vary in the actual shipment. The purchasing order shall prevail iacn any case. Please check each item carefully according to the packing list or purchasing order. If any item is damaged or missing, notify your sales representative.

Installing the Access Point

The RG-RAP2260(G) series must be fixed and installed indoors.

Installation Flowchart

Before You Begin

Before installing the AP, verify that:

  • The installation site provides sufficient ventilation for the AP.
  • The installation site meets temperature and humidity requirements.
  • The installation site is equipped with a proper power supply.
  • Network cables are in place.
  • The installation site meets all described requirements.
  • The custom AP meets customer requirements.

Precautions

To avoid damage to the AP, observe the following safety precautions:

  • Do not power on the device during installation.
  • Install the device in a well ventilated location.
  • Do not subject the device to high temperatures.
  • Keep away from high voltage cables.
  • Install the device indoors.
  • Do not expose the device in a thunderstorm or strong electric field.
  • Keep the device clean and dust free.
  • Disconnect the device before cleaning it.
  • Do not wipe the device with a damp cloth.
  • Do not wash the device with liquid.
  • Do not open the enclosure when the AP is working.
  • Fasten the device tightly.

Installing the Access Point

Ceiling Mount

Attach the mounting bracket on the ceiling or wall.

Attaching the Mounting Bracket on the Ceiling/Wall

Connect the Ethernet cable to the LAN port on the rear of AP

Connecting the Ethernet Cable to the LAN Port

Align the square feet on the rear of the AP over the mounting holes on the bracket. Slide the AP into the holes until it clicks into place.

Fastening the AP

  • Install the Ethernet cables before mounting the AP on the bracket.
  • The AP can be installed in any of four directions on the mounting bracket depending on how you route the Ethernet cable.
  • The square feet should fit easily into the mounting slots.
  • Do not forcibly push the AP into the slots.
  • After installation, verify that the AP is securely fastened.

Removing the Access Point

Hold the AP in your hands and push it upward and away from the bracket in the arrow direction.

Connecting Cables

Connect the UTP/STP to the LAN1/PoE port on the AP. See Appendix A for the supported wiring for twisted pairs.

  • Avoid bending the cable in a small radius close to the connector.
  • Ruijie recommends that you do not use Ethernet cables with protective sleeves as they could make installation of Ethernet cables more difficult.

Bundling Cables

Precautions

  • Make sure the cable bundles are neat and orderly.
  • Bend twisted pairs naturally or in a large radius close to the connector.
  • Do not over tighten a cable bundle as it may reduce cable life and performance.
Bundling Steps
  1. Bundle the drop UTP/STP cables and route them to the LAN/PoE port.
  2. Attach the cables in the cable tray of the rack.
  3. Extend the cables under the AP and run in a straight line.

Checking after Installation

Checking the Cabinet
  • Make sure the external power supply matches the patch panel specifications for the cabinet.
  • After installation, make sure that the front and rear cabinet doors easily close.
  • Make sure the cabinet is stable and level.
  • Make sure the device and all cables are securely fastened in the rack.
Checking Cable Connection
  • Make sure the UTP/STP cable matches the interface type.
  • Make sure cables are properly bundled.
Checking the Power Supply
  • Make sure all power cables are properly connected and safe.
  • Make sure the AP is operational after powering on.

System Debugging

Setting up a Debugging Environment

Use a power adapter or PoE to power the AP.

Setting up the Environment
  • Verify that the AP is properly connected to the power source.
  • Connect the AP to a wireless controller through a twisted pair cable.
  • When the AP is connected to a PC for debugging, verify that the PC and PoE switch are properly grounded.

Powering up the AP

Checking before power-up
  • Verify that the power supply is properly connected.
  • Verify that the input voltage matches the specification of the AP.
Checking after power up recommended

After powering up, it is recommended that you check the following to ensure normal operation of the AP.

  • Check if any message is displayed on the Web-based configuration interface for the wireless controller.
  • Check if the LED works normally.

Monitoring and Maintenance

Monitoring

When RG-RAP2260(G) is operating, you can monitor its status by observing the LED indicator.

Hardware Maintenance

If the hardware is faulty, please contact our Technical Assistance Center (TAC) for help.

Troubleshooting

Troubleshooting Flowchart

Ruijie RG-RAP2260 Reyee Access Point 7

LED does not light up after the AP is powered on
  • If you use PoE power supply, verify that the power source is IEEE 802.11at compliant; then verify that the cable is properly connected.
  • If you use a power adapter, verify that the power adapter is connected to an active power outlet; then verify that the power adapter works properly.
Ethernet port is not working after the Ethernet port is connected
  • Verify that the device at the other end of the Ethernet cable is working properly.
  • And then verify that the Ethernet cable is capable of providing the required data rate and is properly connected.
Wireless client cannot find the AP
  • First, follow the two steps above.
  • Verify that the AP is correctly configured.
  • Adjust the angle of the antennas.
  • Move the client device to adjust the distance between the client and the AP.

Appendix A Connectors and Media

1000BASE-T/100BASE-TX/10BASE-T

The 1000BASE-T/100BASE-TX/10BASE-T is a 10/100/1000 Mbps auto-negotiation port that supports auto MDI/MDIX. Compliant with IEEE 802.3ab, 1000BASE-T requires Category 5e 100-ohm UTP or STP STP is recommended) with a maximum distance of 100 meters (328 feet). 1000BASE-T requires all four pairs of wires be connected for data transmission.

1000BASE-T Connection

Ruijie RG-RAP2260 Reyee Access Point 810BASE-T uses Category 3, 4, 5 100-ohm UTP/STP and 1000BASE-T uses Category 5 100-ohm UTP/STP for connections. Both support a maximum length of 100 meters. Table A-1 shows 100BASE-TX/10BASE-T pin assignments.

100BASE-TX/10BASE-T Pin Assignments
Wiring of straight-through and crossover cables for 100BASE-TX/10BASE-T

A-2 100BASE-TX/10BASE-T Connection

Ruijie RG-RAP2260 Reyee Access Point 9

Appendix B Cabling Recommendations

During installation, route cable bundles upward or downward along the sides of the rack depending on the actual situation in the equipment room. All cable connectors should be placed at the bottom of the cabinet rather than be exposed outside of the cabinet. Power cords should be routed upward or downward beside the cabinet close to the location of the DC power distribution cabinet, AC power outlet, or lightning protection box.

Required Minimum Cable Bend Radius

  • The minimum bend radius of a power, communication or flat cable should be 5 times the overall diameter of the cable. If the cable is constantly bent, plugged or unplugged, the bend radius should be 7 times the overall diameter.
  • The minimum bend radius of a coaxial cable should be 7 times the overall diameter of the cable.
  • If the cable is constantly bent, plugged or unplugged, the bend radius should be 10 times the overall diameter.
  • The minimum bend radius of a high-speed cable, such as an SFP+ cable should be 5 times the overall diameter of the cable.
  • If the cable is constantly bent, plugged or unplugged, the bend radius should be 10 times the overall diameter.
Precautions for Cable Bundling

Before bundling cables, correctly mark labels and stick the labels to cables where appropriate. Cables should be neatly and properly bundled.

Ruijie RG-RAP2260 Reyee Access Point 10

  • Route and bundle power, signal, ground cables separately. When the cables are close to each other, cross them.
  • When power cables run parallel to signal cables, the distance between them must be greater than 30 mm.
  • All cable trays and their accessories shall be smooth and free from sharp edges.
  • Holes in metal, through which cables pass shall have smooth, well-rounded surfaces or be protected with insulating bushings.
  • Use proper cable ties to bind cables together.
  • Do not tie two or more cable ties to bind cables.
  • Cut off excess cable tie cleanly with no sharp edges after bundling cables.

Cutting off Excess Cable Tie

Ruijie RG-RAP2260 Reyee Access Point 11

If cables are to be bent, bind them first but do not tie cable ties within the bend to avoid stress on the cables, which may otherwise cause the wires inside to break.

Do Not Tie Cable Ties within the Bend

Ruijie RG-RAP2260 Reyee Access Point 12

  • Wrap up unnecessary or excess cables and bind them to the appropriate rack position, where device operation is not affected and no damages occur to the device and cables during debugging.
  • Do not bind power cords to the rails for moving parts.
  • Leave a certain length of the cable connecting moving parts, such as the ground wire of the cabinet door, to avoid stress on the cable.
  • When moving parts are in place, ensure the excess cable length shall not contact heat sources, sharp corners or edges.
  • If heat sources are unavoidable, use high temperature cables instead.
  • When using screws to fasten cable lugs, the bolts or nuts shall be tightened and prevented from loosening.

Fastening Cable Lugs

  1. Flat washer
  2. Nut
  3. Spring washer
  4. Flat washer
  • When using a stiff cable, fix it near the cable lug to avoid stress on the lug and cable.
  • Do not use self-tapping screws to fasten terminals.
  • Bundle cables of the same type and running in the same direction into groups.
  • Keep cables clean and straight.
  • Cables shall be tied according to the following table.
Diameter of Cable Bundle mm Space between Bundles mm
10 80 to 150
10 to 30 150 to 200
30 200 to 300

Do not tie knots for cables or cable bundles. The metal parts of the cold- pressed terminal blocks, such as air circuit breakers, shall not be exposed outside of the blocks.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals