Note : The switch model and power supply may be different from  the one shown in the example below. The power supply is sold separately.

Hardware Installation:

  1. Hook the unit over the DIN rail.
  2. Push the bottom of the unit towards the DIN Rail until it snaps into place.

Mounting the Unit:

Ensure the unit is securely mounted according to the hardware installation instructions provided.

Ground Connecting:

The switch must be properly grounded for optimum system performance. Follow the manufacturer’s guidelines for grounding.

Power Connecting:

  1. The DC power should be connected to a well-fused power supply.
  2. Input power should be within the range of 50~57VDC for PoE+ compliant, or 48~57VDC for PoE compliant.

Ethernet Interface Connecting (RJ45 Ethernet):

To connect the Ethernet interface via RJ45:

  • To connect to a PC, use a straight-through or a cross-over Ethernet cable.
  • To connect the switch to an Ethernet device, use UTP (Unshielded Twisted Pair) or STP (Shielded Twisted Pair) Ethernet cables.

LED Indicator:

LED Status Definition
Power Red LED on
Red LED off Power supplying in normal

Power supply abnormal or no powering
RJ45 Indicator| Yellow LED on
Yellow LED flashing Green LED on| Network connection in normal
Link communication in normal PoE feeding in normal
LINK/ACT| Green LED on
Green LED flashing| Optical network Connection in normal
Link connection in normal

Frequently Asked Questions

  • Q: What should I do if the power supply is not working?
    A: If the power supply is not functioning properly, check the connections and ensure it is within the recommended input power range. If issues persist, contact customer support for assistance.

  • Q: How can I troubleshoot network connection issues?
    A: If you are experiencing network connection problems, verify the Ethernet cable connections, ensure proper grounding, and check the LED indicators for any abnormalities. Contact customer support if problems persist.

Quick Reference

Note : The switch model and power supply may be different from the one shown in the example below. The power supply sold separately.cudy-IF1008
-Industrial-Switch-fig- \(1\)

Hardware Installation

  1. Hook the unit over the DIN rail.
  2. Push the bottom of the unit towards the DIN Rail until it snaps into place.cudy-IF1008-Industrial-Switch-fig- \(2\)

Ground Connecting

The switch must be properly grounded for optimum system performance.cudy-
IF1008-Industrial-Switch-fig- \(3\)

Ethernet Interface Connecting

(RJ45 Ethernet)

Connecting the Ethernet interface via RJ45:

  • To connect to a PC, use a straight-through or a cross-over Ethernet cable.
  • To connect the switch to an Ethernet device, use UTP (Unshielded Twisted Pair) or STP (Shielded Twisted Pair) Ethernet cables.
  • The pin assignment of RJ-45 connector is shown in the following figure and table.
    Pin| 1| 2| 3| 6| 4,5,7,8
    ---|---|---|---|---|---
    MDI signal| TX+| TX-| TX+| TX-| –
    MDI-X signal| RX+| RX-| RX+| RX-| –

Power Connecting

The switch can be powered from two power supply (input range 12V – 57V for industrial switch or 48~57V for PoE industrial switch). Insert the positive and negative wires (AWG 14-26) into V+ and V- contact on the terminal block and tighten the wire-clamp screws to prevent the wires from being loosened

NOTE:

  1. The DC power should be connected to a well-fused power supply.
  2. Input power should be within the range of 50~57VDC for PoE+ compliant, or 48~57VDC for PoE compliant.

LED Indicator

LED Status Definition

Power

| Red LED on| Power supplying in normal
Red LED off| Power supply abnormal or no powering

RJ45 indicator

| Yellow LED on| Network connection in normal
Yellow LED flashing| Link communication in normal
Green LED on| PoE feeding in normal
Yellow/Green LED off| No connection at port

LINK/ACT

| Green LED on| Optical network Connection in normal
Green LED flashing| Link connection in normal

Regulatory Statements

Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environ-ment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Non-modification Statement
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

CE Mark Warning
This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

EU declaration of conformity

Cudy hereby declares that this device complies with the essential requirements and other relevant provisions of directives 2014/30/EU, 2014/35/EU, 2009/125/EC and 2011/65/EU.
The original EU Declaration of Conformity may be found at http://www.cudy.com/ce.

Safety Instructions

  • The following general safety guidelines are provided to help ensure your safety and protect your product from potential damage. Remember to consult the product user instructions for more details.
  • Static electricity can be harmful to electronic components.
  • Discharge static electricity from your body (i.e. touching grounded bare metal) before touching the product.
  • Do not attempt to service the product and never disassemble the product. For some products with user-replaceable batteries, please read and follow the instructions in the user manual.
  • Do not spill food or liquid on your product and never push any objects into the openings of your product.
  • Do not use this product near water, or areas with high humidity or condensation unless the product is specifically rated for outdoor application.
  • Keep the product away from radiators and other heat sources.
  • Always unplug the product from mains power before cleaning and use a dry lint-free cloth only