Dettson Supreme ECM Motor ENG User Guide

June 5, 2024
Dettson

Supreme ECM Motor ENG

The Supreme electric furnace with variable speed ECM motor.
The only furnace offering both 2 wires 208/240V models and 3 wires 120 ­ 240/208V models for a direct installation of accessories.
· Multi-position installation · Sequential operation of electrical elements · Approved for line voltage wiring in copper or aluminum · Approved for zero clearance and mobile-home
installations · Separately framed elements allowing quick and
easy replacement · 20” x 20” supply air outlet · Baked painted cabinet · Breakers in front panel

SUPREME
ECM Motor

ADVANTAGE SERIES
· Continuous ventilation selector switch in front panel
· Low/High power selector switch in front panel
· LED indicator for heating demand

MODULATING SERIES

· Semi-conductor modulation on the entire range (0-100%)

for increased comfort and quiet operation

· Control board enabling total command of the unit and

easy configuration · Compatible with the Smart Duct System®

· Allows for our Right-Sized System ®, in combination with

our

heat pump

SUPREME ECM Motor

ARRANT

W S

Y

927 mm 36 1/2″

Right Side View

B

KOE

Identical on the 2 sides

A

Identical on the 2 sides, the back and below.
RETURN 483 mm x 483 mm
19″ x 19″

451 mm 17 3/4″

451 mm 17 3/4″

Top View
559 mm 22″ 25 mm 1″
SUPPLY

25 mm 1″
559 mm 22″

O N PART

508 mm x 508 mm 20″ x 20″
KOE A = 35 mm @ 44 mm
1 3/8″ & 1 3/4″ B = 29 mm
7/8″

Side pannels pre-punched for ease of return-air
installation

Weight: 105 lb (48kg)

ADVANTAGE SERIES

Model #
SUP10-A240V12 SUP15-A240V12 SUP18-A240V12 SUP20-A240V12 SUP23-A240V12 SUP25-A240V12 SUP20-A240V20 SUP23-A240V20 SUP25-A240V20 SUP27-A240V20 SUP30-A240V20

Volts (1 ph*) 2 wires¹
240/208

Input kW (BTU/hr) 10 (34 100) 15 (51 200) 18 (61 400) 20 (68 200) 23 (78 500) 25 (85 400) 20 (68 200) 23 (78 500) 25 (85 400) 27 (92 100) 30 (102 400)

Motor HP 1/2 1/2 1/2 1/2 1/2 1/2 1 1 1 1 1

¹ Can be wired with 3 conductors for 120 ­ 208/240V supply, to allow direct installation of accessories such as humidifiers. ² Static Pressure at 0.5″ W.C. ³ CFM adjustable in heating and cooling

  • 3 phases model available, see with your distributor for more information.

Air flow² Max cfm³
1200 1200 1200 1200 1200 1200 2000 2000 2000 2000 2000

Max cooling (tons) 3 3 3 3 3 3 5 5 5 5 5

MODULATING SERIES

Model #
SUP10-M240V12 SUP15-M240V12 SUP18-M240V12 SUP20-M240V12 SUP23-M240V12 SUP20-M240V20 SUP23-M240V20 SUP25-M240V20 SUP27-M240V20 SUP30-M240V20

Volts (1 ph) 2 wires¹
240/208

Input kW (BTU/hr)
10 (34 100) 15 (51 200) 18 (61 400) 20 (68 200) 23 (78 500) 20 (68 200) 23 (78 500) 25 (85 400) 27 (92 100) 30 (102 400)

Motor HP
1/2 1/2 1/2 1/2 1/2 1 1 1 1 1

Traditionnal Ducts²

Airflow Max (cfm)

Max cooling (tons)

1400

3.5

1400

3.5

1400

3.5

1400

3.5

1400

3.5

2200

5.5

2200

5.5

2200

5.5

2200

5.5

2200

5.5

¹ Can be wired with 3 conductors for 120 ­ 208/240V supply, to allow direct installation of accessories such as humidifiers. ² Static Pressure at 0.5″ W.C.

Smart Ducts®

Airflow Max (cfm)

Max cooling (tons)

1000

2.5

1000

2.5

1000

2.5

1000

2.5

1000

2.5

1600

4

1600

4

1600

4

1600

4

1600

4

3400, boulevard Industriel Sherbrooke, Québec J1L 1V8 Canada

T 1.819.346.8493 TF 1.800.567.2733 F 1.819.822.4227 info@dettson.ca www.dettson.com

Specifications subject to change without notice.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals