Specifications
- Model: PRO PAR
- Model No.: PAR5x12, PAR12x12
- Power Supply: 100~240 VAC, 50/60 Hz
- Maximum Power Consumption: 8A
For safety, please read this user manual carefully before initial use.
Event Lighting reserves the right to revise the manual at any time.
Information and specifications within this manual are subject to change
without notice. Event Lighting assumes no liability or responsibility for any
errors or omissions. Please consult Event Lighting for any clarification or
information regarding this item.
Safety Instructions
WARNING
- Do not open this device, there are no user-serviceable parts inside. Risk of electric shock.
- Do not look at the light source when the device is on.
- CAUTION: This unit’s housing may be hot during and after operation.
- Install this device in a location with adequate ventilation, at least 20 inches (50 cm) from adjacent surfaces.
- Do not leave any flammable material within 50 cm of this unit while operating or connected to power.
- Use a safety chain when mounting this device overhead.
- Do not operate this device outdoors or in any location where dust, excessive heat, water, or humidity may affect it.
- Do not operate this device if the housing, lenses, or cables appear damaged.
- Do not connect this device to a dimmer or rheostat.
- ONLY connect this device to a grounded and protected circuit.
- ONLY use the hanging bracket to carry this device.
- In case of a serious operating problem, stop using it immediately.
- The maximum ambient temperature is 104° F (40° C). Do not operate this device at higher temperatures.
Power Input & Power Linking
- This device has an auto-switching power supply work with an input voltage range of 100~240 VAC, 50/60 Hz.
- Link up to the maximum 8A. DO NOT exceed this number.
Product Installation
- This device can be mounted in many orientations provided each device is secured by the use of the correct mounting bracket.
- Use a safety chain when mounting this device overhead.
Fuse Replacement
- If the fine-wire fuse of the device fuses, only replace the fuse with a fuse of the same type and rating.
- Before replacing the fuse, unplug the main lead.
Procedure:
- Step 1 : Unscrew the fuse holder on the rear panel with a fitting screwdriver from the housing (anticlockwise).
- Step 2: Remove the old fuse from the fuse holder.
- Step 3: Install the new fuse in the fuse holder.
- Step 4 : Replace the fuse holder in the housing and fix it.
Lux Chart
Dimensions
CONTROL BOARD OPERATION
Display | Function |
---|---|
DMX Add | To set the DMX address |
DMX Cha
| To set DMX channel modes
Ch12, CH08, CH06, CH03, CH02
Dimmer
| ****
To set dimmer curve: 01, 02, 03, 04, 05
Sound| To set sound active mode and the sensitivity (Sen000 ~ Sen100)
Static C
| To set static colors: Static Color R, G, B, W, A, U, GB, RB, RG, RGB, RW, GW, BW, WA, RA, GA, BA, RGW, RBW, GBW,
RGBW,GBA,BWA,RGA,GWA,RWA,RGBA,GBWA,RBWA,RGWA,RGBQA,RU,GU,AU,RAU,RGBWAU
Manual C| To set the user mode intensity of each colour separately for color mixing and strobe rate
Auto Pro
| To set built-in automatic programs (Pr 01 ~ Pr 05) and speed from Sp000 to Sp100 To set sound active mode (Pr 06) and sound sensitivity from Sen000 to Sen100
To set multi fixture chases (Pr 07)
Mas/Sla| To set Master/Slave modes
Reset| To reset the factory default setting
DMX Addressing:
After selecting the “DMX Add” and pressing “Enter”, use the “Up” and “Down”
buttons to select the desired DMX address press “Enter” to save the new
setting
DMX Modes
After selecting the “DMX Cha” and pressing “Enter”, use the “Up” and “Down”
buttons to select the desired DMX mode, press “Enter” to save a new setting
Dimmer Speed Setting:
After selecting the “Dimmer” and pressing “Enter”, use the “Up” and “Down”
buttons to select the desired dimmer curves,
Sound Mode
Entered “sound” mode, use the “Up” and “Down” buttons to select the
sensitivity Sen000-Sen100, and press “Enter” to save the new setting
Manual Color Mo de
Set the intensity of each color separately to get endless color mixing from
the control panel with the strobe function.
Entered “Manual C” mode, use the “Up” and “Down” buttons to select each color
(RGBW or RGBWAUV) intensity from 000 to 255 and strobe (S) speed from S000 to
S100. (S000 is freeze and S001 to 100 is from slow to fast) Press “Enter” to
save a new setting
Setting Static Colour
Entered “Static C” mode, you can select the desired solid color via the
“UP” or “DOWN” buttons, and press “Enter” to save the new setting
Value: | Function: |
---|---|
R | Red |
G | Green |
B | Blue |
W | White |
A | Amber |
UV | UV |
GB | Green + Blue |
RG | Red + Green |
RB | Red + Blue |
RW | Red + White |
GW | Green + White |
BW | Blue + White |
WA | White + Amber |
RA | Red + Amber |
GA | Green + Amber |
BA | Blue + Amber |
RGB | Red +Green + Blue |
RGW | Red + Green + White |
RBW | Red + Blue + White |
GBW | Green + Blue + White |
GBA | Green + Blue + Amber |
BWA | Blue + White + Amber |
RIGA | Red + Green + Amber |
GWA | Green + White + Amber |
RWA | Red + White + Amber |
RGBA | Red + Green + Blue + Amber |
GBWA | Green + Blue + White + Amber |
RGBW | Red + Green + Blue + White |
RBWA | Red + Blue + White + Amber |
REWA | Red + Green + White + Amber |
EGBWA | Red + Green + Blue + White + Amber |
RU | Red + UV |
GU | Green + UV |
AU | Amber + UV |
RAU | Red + Amber + UV |
… | …. |
RGBWAU | Red + Green + Blue + White + Amber + UV |
Automatic & Sound Mode
- This fixture has 7 built-in programs.
- Entered “Auto Pro” mode, use the “Up” and “Down” buttons to select the built-in programs “Pr 01 ~ Pr 07” then press the “Enter” to confirm.
- Use the “Up” and “Down” buttons to select the operating speed of the program (Value: S000 ~ S100, Freeze, Slow ~ Fast), and press “Enter” to save the new setting.
Mode:|
---|---
Auto Program
| Value:| Function:
Pr 01| RGBWAU Model R G B W A UV colour-switching
Pr 02| RGBWAU Model 36 colour switching
Pr 03| RGBWAU Model R G B W A U color fading
Pr 04| RGBWAU Model 36 colour fading
Pr 05| Color Macros Fading
Pr 06| Sound active mode
Pr 07| Multi fixture chases
To set sound to active mode Pr 06
- Entered “Auto Pro” mode, use the “Up” and “Down” buttons to select the built-in program “Pr 06”, and press “Enter” to confirm.
- Use the “Up” and “Down” buttons to select the sensitivity Sen000 ~ Sen100, and press “Enter” to save the new setting
To set multi fixture chases Pr 07
Before starting, go to each fixture and reset the menu to fixture defaults.
- On the master unit, set the DMX address to the total number of fixtures in the string. For example, you may have a total of 20 par cans including the master, so the DMX address should be set to “20”.
- On the master unit, go to the master/slave menu setting and set the unit to master
- On the master unit, set the unit to “Auto Mode” “Pr 07” which supports multi-fixture chases.
- On each slave unit, set the DMX address to the fixture position in the string. For example, if this unit is the 2nd unit in the string including the master, then set the DMX address to 2. If this is the last unit of 20, then the DMX address should be set to 20. It is possible to double up fixture positions as well as fixture 1.
- On each slave, go to the master/slave menu setting and set it to slave.
Master/Slave Operation
- Set the master fixture to one of the standalone operating modes: automatic, sound, static color, or manual color modes
- Set the slaves, enter “Mas/Sla” mode, set to “S”, press “Enter”
DMX Chart
2 channels Mode
Channel | Value | Function |
---|---|---|
1 | 000-255 | Warm white to cool white |
2 | 000-255 | dimmer 0% ~ 100% |
3 channels Mode
Channel | Value | Function |
---|---|---|
1 | 000-255 | Red: 0% ~ 100% |
2 | 000-255 | Green: 0% ~ 100% |
3 | 000-255 | Blue: 0% ~ 100% |
6 channels Mode
Channel | Value | Function |
---|---|---|
1 | 000-255 | Red: 0% ~ 100% |
2 | 000-255 | Green: 0% ~ 100% |
3 | 000-255 | Blue: 0% ~ 100% |
4 | 000-255 | White: 0% ~ 100% |
5 | 000-255 | Amber: 0% ~ 100% |
6 | 000-255 | UV: 0% ~ 100% |
8 channels Mode
Channel | Value | Function |
---|---|---|
1 | 000-255 | Red: 0% ~ 100% |
2 | 000-255 | Green: 0% ~ 100% |
3 | 000-255 | Blue: 0% ~ 100% |
4 | 000-255 | White: 0% ~ 100% |
5 | 000-255 | Amber: 0% ~ 100% |
6 | 000-255 | UV: 0% ~ 100% |
7 | 000-255 | Master DIMMER 0% ~ 100% |
8
| 000-009| No function
010-019| Sound Active
020-255| Strobe : Slow ~ Fast (1~30Hz)
12 channels Mode
Channel | Value | Function |
---|---|---|
1 | 000-255 | Red: 0% ~ 100% |
2 | 000-255 | Green: 0% ~ 100% |
3 | 000-255 | Blue: 0% ~ 100% |
4 | 000-255 | White: 0% ~ 100% |
5 | 000-255 | Amber: 0% ~ 100% |
6 | 000-255 | UV: 0% ~ 100% |
7 | 000-255 | Master DIMMER 0% ~ 100% |
8 | 000-009 | Strobe OFF |
010-255 | Strobe (slow-fast 1-30Hz) |
9
| 000-019| No Function
020-039| RED 100% / GREEN 0% ~ 100% / BLUE 0%
040-059| RED 100% ~ 0% / GREEN 100% / BLUE 0%
060-079| RED 0% / GREEN 100% / BLUE 0% ~ 100%
080-099| RED 0% / GREEN 100% ~ 0% / BLUE 100%
100-119| RED 0% ~ 100% / GREEN 0% / BLUE 100%
120-139| RED 100% / GREEN 0% / BLUE 100% ~ 0%
140-159| RED 100% / GREEN 0% ~100% / BLUE 0% ~ 100%
160-179| RED 100%~ 0% / GREEN 100% ~ 0% / BLUE 100%
180-200| RED 100% / GREEN 100% / BLUE 100% /WHITE 100%
201-204| Color Temperature 1| ****
205-209| Color Temperature 2
210-214| Color Temperature 3
215-219| Color Temperature 4
220-224| Color Temperature 5
225-229| Color Temperature 6
230-234| Color Temperature 7
235-239| Color Temperature 8
240-244| Color Temperature 9
245-249| Color Temperature 10
250-255| Color Temperature 11
10
| 000-009| No Function
010-049| R G B W A UV color switching
050-090| 36 colour switching
091-131| R G B W A U color fading
132-172| 36 colour fading
173-213| Color Macros Fading
214-255| Sound active mode
11| 000-255| Speed of auto programs (slow ~ fast) or sound sensitivity
12
| 000-009| Use a dimmer curve from the setting of the control board
010-057| 16 bits Linear dimmer 1
058-106| 16 bits Non-linear dimmer 2
107-155| 16 bits Non-linear dimmer 3
| 156-204| 16 bits Non-linear dimmer 4
---|---|---
205-255| 8 bits Linear dimmer 5
TECHNICAL SPECIFICATIONS
Model | PAR5x12 | PAR12x12 |
---|
Dimensions and Weight
Overall size LxWxH (mm)| 207x227x120| 263x293x98
Weight (kg)| 1.9| 3.2
Power
Power Supply| 100~240V AC, 50/60 Hz
Power Consumption (w)| 50| 120
Fuse| T 1 A, 250 V| T 2 A, 250 V
LED| 5pcs 12W RGBWA+UV 6 in 1 LED| 12pcs 12W RGBWA+UV 6 in 1 LED
Operation Modes| DMX, auto run, sound active, master/slave, manual color
control, static
colour control
Beam Angle| 30°
Refresh Rate| 2940Hz
DMX Channel mode| 2, 3, 6, 8,12
Power Input| Neutrik® Powercon
Power Output| Neutrik® Powercon
WARRANTY
Please contact your local Kookaburra Account Manager.
FAQ
- Q: What should I do if the device is not powering on?
- A: Check the power source and ensure it is within the specified voltage range. Verify that the fuse is intact and replace it if necessary following the provided instructions.
- Q: How do I change the DMX address of the device?
- A: Use the control board to set the DMX address by selecting the desired address and saving the new setting as per the user manual instructions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>