EVENT LIGHTING lite PAR12X12L 12x 12W LED RGBWAU Parcan with IR Remote User Manual

June 5, 2024
EVENT LIGHTING lite

EVENT LIGHTING lite PAR12X12L 12x 12W LED RGBWAU Parcan with IR Remote

For your safety, please read this user manual carefully before use. Event Lighting reserves the right to revise the manual at any time. Information and specifications within this manual are subject to change without notice. Event Lighting assumes no liability or responsibility for any errors or omissions. Please consult Event Lighting for any clarification or information regarding this item.

Safety Instructions

Warning

  • Do not open this device, there are no user serviceable parts inside. Risk of electric shock.
  • Do not look directly at the light source from close range.
  • Avoid contact with the unit during operation, as the housing may become hot. Allow the fixture to cool for at least 15 minutes after turning off before touching.
  • Install this device in a location with adequate ventilation, at least 50cm from adjacent surfaces.
  • Do not operate this device, or connect this device to power, within 50cm of any flammable material.
  • Use a safety chain when mounting this device overhead.
  • Do not operate this device outdoors where excessive dust, heat, water, or humidity may affect it.
  • Do not operate this device if the housing, lenses, or cables appear damaged.
  • Do not connect this device to a dimmer or rheostat.
  • Do not operate this device at temperatures higher than 40°C (104°F).
  • Only connect this device to a grounded and protected circuit.
  • Only use the hanging bracket to carry this device.
  • Stop using this device immediately if a serious operating problem becomes apparent.

Coin/Button Cell Battery Safety Information
This product includes an IR remote that contains a coin/button cell battery. If the battery is swallowed, it can cause severe internal burns and, in extreme cases, can lead to death. Keep batteries away from children.

Product Installation

PAR12X12L can be mounted in many orientations, provided each individual device is secured by the use of the correct mounting bracket. Use a safety chain when mounting PAR12X12L overhead.

Dimensions

Lux Chart

Control Board Operation

Menu Map

Static Colour Mode

Value Function
C1 Red
C2 Green
C3 Red+Green
C4 Blue
C5 Blue+Red+UV
C6 Green+Blue
C7 Red +Green+Blue+Amber+UV
C8 White
C9 Red+White
C10 Green+White
C11 Red+Amber
C12 Blue+White+UV
C13 Red + Blue+White+UV
C14 Red + Blue+White
C15 Red+Green+Blue+White+Amber+UV

DMX Chart

6 Channel Mode

Channel Value Function
1 000-255 Red: 0% ~ 100%
2 000-255 Green: 0% ~ 100%
3 000-255 Blue: 0% ~ 100%
4 000-255 White: 0% ~ 100%
5 000-255 Amber: 0% ~ 100%
6 000-255 UV: 0% ~ 100%

11 Channel Mode

Channel Value Function Note
1 000-255 Master DIMMER 0% ~ 100%
2 000-255 Red: 0% ~ 100%
3 000-255 Green: 0% ~ 100%
4 000-255 Blue: 0% ~ 100%
5 000-255 White: 0% ~ 100%
6 000-255 Amber: 0% ~ 100%
7 000-255 UV: 0% ~ 100%
8 000-012 Strobe OFF
013-255 Strobe (slow-fast)







9

| 000-009| No Function|
010-019| Program 1|
020-029| Program 2|
030-039| Program 3|
040-049| Program 4|
050-059| Program 5|
060-069| Program 6|
070-079| Program 7|
080-089| Program 8|
090-099| Program 9|
100-109| Program 10|
110-119| Program 11|
120-129| Program 12|
130-139| Program 13|
140-255| Sound active mode|
10| 000-255| Speed of auto programs (slow

~ fast)

| Ch9 must be set between

10-139

11| 000-255| Colour fade time (jump ~ fade)| Mode must be set to “nod0”

IR Remote

  • In order to use the IR Remote, PAR12X12L must be in DMX mode without an active DMX connection. If a DMX signal is received, PAR12X12L will prioritise the DMX signal and ignore the IR Remote.
  • Use On/Off to turn PAR12X12L on or off. The current IR settings will be saved automatically when PAR12X12L is powered off and reloaded when it is turned on again. To reset to the factory default Blackout mode, long press Off.
  • Press R/G/B/W/A/U to light up the LEDs in red, green, blue, white, amber or UV respectively. Press a number 0-9 in the orange shaded area to select a pre-set colour.
  • Press + to increase the intensity of the selected colour and – to decrease the intensity of the selected colour.
  • Press Auto/Sound/Strobe to switch on or off Auto mode, Sound Active mode and Strobe mode, respectively.
  • Press Blackout to clear all the remote settings and blackout PAR12X12L.

Technical Specifications

Photometric

  • Light Source: 12x 8W RGBWAU 6-in-1 LEDs
  • Beam Angle: 40°
  • PWM: 20,000Hz
  • LED Lifespan: 50,000hours

Effects

  • Dimming: 0~100%
  • Strobe: 1 – 20 Hz

Power

  • Input Voltage: 100~240V AC, 50/60Hz
  • Power Consumption: 60W
  • Connection: IEC in/out

Control

  • Operation Modes: DMX, manual, auto, sound active, IR remote, master/slave
  • DMX channels: 6/11

Housing

  • Cooling: Fanless Cooling
  • Net weight: 1.85kg

Warranty

Please refer to your local dealer or contact Event Lighting.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

EVENT LIGHTING lite User Manuals

Related Manuals