BEOK CONTROLS TCR8 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual

August 2, 2024
BEOK CONTROLS

TCR8 IPS Colorful LCD Screen Smart Thermostat

“`html

Specifications:

  • Supply voltage: AC100~240V 50/60Hz
  • Power consumption: Wi-Fi 3W Max
  • Temperature setting range: 5~95°F (41~203°F)
  • Floor limited range: 20~90°F (68~194°F)
  • On/off deviation: 0.5~10°F (1~10°F)
  • Ambient temperature: -5~50°C (23~122°F)
  • Protection level: IP20
  • Shell material: Anti-Flammable PC

Product Overview:

This series of thermostat offers Floor Heating, Fan Coil, and
Integrated versions, suitable for various scenarios.

Product Usage Instructions:

1. Voice Control:

The device can be controlled by voice through Amazon Alexa and
Google Assistant.

2. Programmable Settings:

The thermostat is programmable with multiple periods allowed to
be set per day.

3. Display Symbols:

The display shows time, date, week, outdoor temperature, outdoor
humidity, Fan Coil valve status, Floor Heating valve status, mode,
and menu options.

4. Temperature Control Modes:

  • Auto Mode: Automatically adjusts temperature based on
    settings.

  • Child-lock Mode: Locks the thermostat to prevent unintended
    changes.

  • Frost Protection: Activates to prevent freezing
    temperatures.

5. User Operation:

Press the buttons to switch between modes and adjust settings.
Use the knob for manual temperature control.

6. Wi-Fi and Bluetooth Settings:

Configure Wi-Fi settings for remote control capabilities.
Bluetooth Mode and Access Point Mode are also available for network
connectivity.

7. Timer Task Setting:

Set schedules by entering the menu page, selecting Auto Mode,
choosing Schedule, and adjusting parameters before saving.

8. Advanced Settings:

For professional technicians, access the Engineer Mode to adjust
settings like Handwheel, ModBus Address, Sensor Calibration, and
Temperature Differential.

FAQ:

Q: Can this thermostat be controlled remotely?

A: Yes, the thermostat can be controlled remotely through Wi-Fi
and voice assistants like Amazon Alexa and Google Assistant.

Q: What is the temperature setting range of this

thermostat?

A: The temperature setting range is from 41°F to 203°F (5°C to
95°C).

Q: How do I set a schedule on this thermostat?

A: Press the designated buttons to access the menu, select Auto
Mode, choose Schedule, adjust the parameters using the knob, and
save by pressing Home.

“`

IPS Colorful LCD Screen Smart Thermostat

03.11 Thur

18:00

Fair 22
Humidity 68%

68% ROOM

18.5

25.5

next

enter

home

back

Programmable device, multiple periods allowed to set per day.

The device can be controlled by voice through Amazon Alexa and Google Assistant

Parameter

Supply voltage Power consumption Temp. setting range Floor limited range On/off deviation Ambient temperature Protection level Shell material

AC100~240V50/60Hz Wi-Fi 3W Max 5~9541~203 20~9068~194 0.5~101~10Factory setting 1 -5~5068~122 IP20
Anti-Flammable PC

Version:TCR8 1.1(12/2022)

Product Overview
This series of thermostat has Floor Heating, Fan Coil, and Integrated version, meeting the requirements under different scenarios.

Version

System mode Model

Application

EP

Built-in & floor sensor, floor limit sensor + Weekly programming

Floor heating Floor heating

WP A NC/NO dual-output + Weekly programming

WPB

A NC/NO dual-output + Weekly programming+ Potential-free output

AC2 Timer task + 2-pipe system

Fan Coil

Heating /Cooling / Ventilation

AC2-485

Timer task + 2-pipe system + Timer task + Potential-free output + 485Modbus (optional) + Room card (optional)

AC4

Timer task + 4-pipe system + Timer task + Potential-free output + 485Modbus (optional) + Room card (optional)

Fan-Coil with

Floor heating & fan coil, weekly programming +

Integrated

Floor-Heating AWY Potential-free output + Timer task +

air condition system

485Modbus (optional) + Room card (optional)

Display Symbols

Time Display
Date Week Outdoor temp.
Outdoor humidity Fan Coil valve
Floor Heating valve Mode Menu

03.11 Thur

18:00

Fair 22
Humidity 68%

68% ROOM

18.5

25.5

next

enter

home

back

Fan Speed Temperature Control Mode(Floor Heating/Integrated)
Auto Mode

Child-lock Mode Frost Protection Wi-Fi Room humidity Set Temp.
Working mode Fan Auto Mode Manual Mode Temporary Mode
Knob

Manual Mode Thermostat works based on manually-set temperature, disconnecting from auto mode. Temporary Mode Thermostat works based on manually-set temperature temporarily and then shifts back to auto mode till next event. User Operation
Temp setting: Rotate handwheel” “to change setting temperature by 0.5°C. System mode: Press ” ” shortly to switch cooling/heating/ventilation. (Fan Coil)
Press ” ” shortly to switch cooling/heating/ventilation/floor heating/floor heating + heating. (Integrated) Temp control mode:

Wi-Fi setting

Wi-Fi setting Bluetooth Mode(Suggest) Access Point Mode

Bluetooth Mode
Bluetooth Mode

Access Point Mode
Access Point Mode

Please don’t leave, Bluetooth is in the network…

Please don’t leave, Access Point is in the network…

Timer Task Setting (Fan Coil/Integrated)

Press” “to enter the menu page. Turn the knob” “, choose “Auto Mode”, and then choose ” Schedule “. Set the parameters by turning the knob, then press ” Home “to save and exit to home page.

Time Setting Repeat Action

00:00 Everyday
OFF

Schedule

00:00

ON

OFF Everyday

Add

Advanced Setting (Usually for Professional Technicians)
Under power-on status, long press menu button ” ” to enter the menu page, choose Engineer Mode, enter the advanced setting page. After setting the parameters, press menu button ” ” to save and exit.

function list

Handwheel ” ”

ModBus Address Sensor Calibration Temp. Dif.

Adjustment range 0~250
-9.9~9.9(-9.9~9.9) 0.5~10(1~10)

Max Setting Value 5~95(41~203)

Min Setting Value 5~47(41~117)

Anti-Freeze Protection ON/OFF

Temperature Unit /

Default Integrated Fan Coil Floor Heating

Value

AWY AC2- AC4 AC2 EP WP WPB

485

0

×

0

1

50

5

OFF

Sensor Mode Floor limited Value

Built-in sensor Floor sensor Built-in Control & Floor Limitation
20~90(68~194)

IN 35

× × × × × ×

Monday to Friday Monday to Satuiday Monday to Sunday

2-day × × ×

Fan control settings

00: Fan speed controllable 01: Fan speed uncontrollable

00

×× ×

Linkage Time Delay 0~5min

0min × × ×

None Lock All All but power

None

Function Off Function On Function Saved Air-Condition Mode All/Cold Only

Temp Control

Manual/Auto

Reset All Settings Yes/No

Last

All

×× ×

Manual × × × × × ×

/

Enter menu: Press ” ” enter the menu interface. Child-lock: Press ” ” + ” ” for 3 seconds to activate child-lock.

IPS Colorful LCD Screen Smart Thermostat Auto-mode Setting (Fan Coil/Integrated)

Events

Workdays Weekends

Sunrise Morning Nooning Afternoon Evening
Night
Sunrise Night

Time Default value Modify
06:00 08:00 11:30 12:30 17:00 22:00 08:00 22:00

Default value 20 15 15 15 22 15 20 15

Dimensions (Unit: mm)

Floor Heating

11 32.6

51

EP

WP

WPB

Fan Coil

AC2

Rotate handwheel Rotate handwheel

Modify 51

Fan Coil #AC2-485 #AC4 Integrated #AWY

11 2 4

64 66

Mounting Steps
The thermostat adopt pre-guide and limited snap-fit design. It is easy to mount. 1Release front cover by inserting a head screw-driver into bottom crack.

2Insert the wires and then fix these wires with screws. Suggested wire- stripping length is 7-9mm.
3Mount backing plate into wall-cassette, put screws and then fix thermostat. Make sure that the thermostat is fixed without deformation. Suggested torque is 0.2~0.4N.m (2.0~4. 1kgf.cm).

4Re-mount the front cover via snap-fit connection.
Sensor failure

Installation instructions
Connecting Diagram
The thermostat operates in full capacity in areas with the altitude of less than 2500 above sea level. Power rating of external load should be less than or equal to 80% rated power of the thermostat in areas with altitude of 2500m to 4200m.

Floor Heating

TCR8-WIF-EP # TCR8-EP

L N N1 L1 AC100~240V

TCR8-WIFI-WP # TCR8-WP #TCR8-WIFI-WPB # TCR8-WPB

LN AC100~240V Normally-closed
electric actuator

NTC
PC1 PC2
Potential-free (Potential-free output, for model WPB only)
Dry contact signal to control boiler

Linkage control; delay time of linkage control is adjustable
PC1 PC2

L

N

AC100~240V

Normally-open electric actuator

Potential-free (Potential-free output, for model WPB only)
Dry contact signal to control boiler

Linkage control; delay time of linkage control is adjustable
PC1 PC2

LN AC100~240V

Potential-free
Three-wire (Potential-free output, for model WPB only) electrical ball valve Dry contact signal
to control boiler

Fan Coil

Linkage control; delay time of linkage control is adjustable
L N HI MED LOW OPEN CLOSE

TCR8-WIFI-AC2 # TCR8-AC2

TCR8-WIFI-AC2-485 # TCR8-AC2-485

LN AC100~240V
N

Fan

Air conditoner

valve

N

CLOSE OPEN HI MED LOW L

89

N

Air conditoner

valve

N

PC1 PC2

Linkage control; delay time of linkage control is adjustable

16 15

CARD
14 13

Fan

L

AC100~240V

RG A B
12 11 10

TCR8-WIFI-AC4

Room card

Dry contact signal room card linkage

to control heat pump

(optional)

485A 485B (optional)

N CLOSE OPEN CLOSE OPEN HI MED LOW L

89

TCR8-AC4 N

N
Linkage control; delay time of linkage control is adjustable

L

Heat valve Cool valve

Fan AC100~240V

PC1 PC2 CARD

RG A B

16 15 14 13 12 11 10

Room card

Dry contact signal room card linkage

to control heat pump

(optional)

485A 485B (optional)

Integrated

TCR8-WIFI-AWY # TCR8-AWY

N CLOSE OPEN CLOSE OPEN HI MED LOW L
89

N

Floor system Air conditoner

valve

valve

Fan

L

AC100~240V

N

PC1 PC2 CARD RS RG A B

Linkage control; delay time of 16 15 14 13 12 11 10
linkage control is adjustable

Dry contact signal to control heat pump

NTC Room card

485A 485B (optional)

room card linkage(optional)

Read User Manual Online (PDF format)