BEOK CONTROLS BOT-323W Series Boiler Thermostat Instruction Manual
- July 8, 2024
- BEOK CONTROLS
Table of Contents
- BEOK CONTROLS BOT-323W Series Boiler Thermostat Instruction Manual
- Product Summary
- Technical Parameter
- Main Button Instruction
- User Interface Explanation
- Wiring Diagram
- Operation Instruction
- Default Program Data
- Advanced Setting
- Installation
- Read More About This Manual & Download PDF:
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BEOK CONTROLS BOT-323W Series Boiler Thermostat Instruction Manual
Product Summary
BOT-323W series boiler thermostats are with LCD digital display screen, and it is developed according to the market’s requirements. This series of thermostats are easy to operate and with complete functions. It can be used to control boilers, motorized ball valves, motorized valves, electric valves, solenoid valves, etc.
Technical Parameter
Main Button Instruction
User Interface Explanation
Wiring Diagram
- NC: Normally Closed Interface (Boller or Loading);
- COM: Common Interface (Boiler or external power input) ;
- NO: normally open Interface (Boiler or Loading) ;
Alt: installation wires should be changed to be 1. 5-2. 5mm• hard line. Please rightly connect the wires strictly according to the connection diagram. Don’t make water, mud and other debris into the thermostat, otherwise, It wlll damage the thermostat.
Operation Instruction
Time Setting
Press(9 , the time area will display Minute, Hour end Week, then press A or vto modify time.
Programmable Period Temperature Setting
The first step, long press(), screen display LooP(Cycling Control), screen displays 12345 (From Monday to Friday); PreasA one time, it displays 12345B(From Monday to Saturday); Press A two times, ii displays 12345lllil(From Monday to Sunday);
Second slap, time, and temperature setting in every period. When screen display 12345 or 123.for 12345111121, press()to enter temperature setting. Press (9 to enter lime satti ng. To modify and save throughAor’7. Att: When auto-control, If user needs to reset the temperature, II can be changed to temporary manual control. Temporary manual control means when the thermostat is in auto-control mode(program mode), user press A or ‘<? to modify the temperature setting, thermostat now Is In a temporary manual control state. Whan next periods comas, the thermostat will automatically return to acquiescent period program control mode.
If you want to make temporary adjustment in any period, press() then i!:’ will flash. When finish setting, all will confirm automatically. Press () to switch operation between manual mode and programmable mode. Alt: While in automatic control, ~will disappear, the temperature must be reset during automatic control, press A.or “‘v’ to adjust (It is a temporary manual mode and the next time period will automatically run to the automatic mode).
Period Temperature Setting
First press(), then press (910 change to time options, user can modify time in the period.
Default Program Data
Attention
- The default temperature values of 3 and 4 periods in the workday are the same as 2 periods. If the user need it, please change this default temperature.
- Setting temperature is 00, it means this period Is powered off.
Advanced Setting
- Firstly, Press the down button
- Then, press the power button
- After entering the advanced setting, press to choose next parameter changing.
In the state of power-off, long press and hold then press(!) into advanced setting mode. Then press o to set relative item.
Installation
-
See figure 1, mounted on the wall with a pitch of 86mm screw expansion sleeve.
-
See figure 2, open the surface shell and the bottom shell, according to the alignment direction, route the desired wire through the back of the case to the wire slot, and according to the actual situation to set aside about 20CM length.
-
See figure 3, fix the bottom shell on the wall, terminal fixed wire, cover the bottom shell with the surface shell.
ATT
Thank you for buying this product! Please read this manual for complete instructions on installing and operating your thermostat. If you require further assistance, please feel free to contact us.
In the box you will find
Our Service
We offer a warranty of 24 months from the sales day. During the warranty, if it belongs to the quality issue, we will fix or replace them for you for free after testing them. If it is not a quality problem or beyond the warranty time, we will charge for the after-sales service.
Warning
The symbol means the unit is being installed, it may cause electrical shock hazards during maintenance, so please make sure it is operated by a professional technical worker.
BEOK BOT-323W Thermostat User Manual
Read More About This Manual & Download PDF:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>