DEWERT OKIN HE150 Gardhen Bilance Instruction Manual
- July 31, 2024
- DEWERT OKIN
Table of Contents
- DEWERT OKIN HE150 Gardhen Bilance
- Installation Instructions
- General Information
- Safety notices
- Possible combinations
- Description
- Technical specifications
- Installation
- Information about creating your Operating Manual
- Troubleshooting
- Maintenance
- Disposal
- EU Declaration of Conformity
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DEWERT OKIN HE150 Gardhen Bilance
Installation Instructions
(Translation of the original installation instructions)
Foreword
Disclaimer and exclusion of liability
DewertOkin is not responsible for damage resulting from:
- failure to observe these instructions,
- changes made to this product that have not been approved by DewertOkin, or
- the use of replacement parts that have not been approved or manufactured by DewertOkin.
- We reserve the right to make unannounced technical changes in the course of our continual product improvement process!
Creation of a complete operating instruction manual for the entire end
product
These instructions are only intended to be used by the end-product
manufacturer. They should not be given to the operator of the end product. The
factual information contained within may be used as a basis when creating the
end-product manual. The warning and danger notices are best suited for use in
the end product’s manual. However, it is not sufficient to simply follow these
notices. You should also carry out an internal risk assessment for your end
product. This can then be used as the basis for the safety notices in your
manual. These installation instructions do not contain all the information
required to safely operate the end product. They only describe the
installation and operation of the product as partially completed machinery.
The instructions are intended for the technicians responsible for
manufacturing an end product and not for the operators of the end product.
Usage in medical products
The HE150 is not a medicinal product. If used in a medical end product, you
(the end manufacturer) are obliged to ensure compliance with EC directives and
to ensure that other pertinent medical product regulations are maintained.
General Information
About these installation instructions
To install the HE150 successfully and safely in the end product, these
installation instruc-tions must be observed. These instructions are not an
operating manual for the end product. These instructions will help you to
minimize danger, repair costs, and downtime. They will also help you to
increase the reliability and lifespan of the device.
CAUTION
The notices in these instructions must be followed! Follow the guidelines
during installation and connection procedures to minimize:
- the risk of accident and injury, and
- damage to the HE150 or the end product.
These installation instructions have been written with due care and attention. However, we cannot guarantee that the data, images, and drawings are complete and correct nor do we accept any liability for the information contained therein, unless required by law.
Conventions used
Notices which do not relate to safety are indicated in these instructions with
a symbol:
- Triangular notice symbol
Explanations of warning notices
- CAUTION indicates a hazardous situation that, if not avoided, could result in minor or moderate injury.
- NOTICE is used to address practices that are not related to personal injury but may result in damage to the product or surroundings.
Safety notices
Proper and intended usage
The HE150 is intended for use:
- as a control unit for suitable DewertOkin drive systems,
- for HOME applications (in beds, reclining chairs, etc.),
- with external power supply.
CAUTION
Risk of accident
The HE150 should only be used for the applications described above. Any other
use is forbidden. Improper usage can lead to accidents or destruction of the
unit. Such non-approved applications will lead immediately to the expiration
of all guarantee and warranty claims on the part of the end-product
manufacturer against the manufacturer.
Improper usage
Be sure to follow the notices below concerning improper usage. You should
include them in your product manual to inform the users of your end product.
The HE150 should not be used:
- in any environment where combustible or explosive gases or vapors (e.g., anaesthesiology) may be present,
- in the proximity of open fires or other heat sources (such as furnaces, ovens, or direct sunlight),
- as a power source for toys or games,
- in any application that will be cleaned with an automated washing system,
- in a moist environment, or
- outdoors.
The HE150 can be used by children of 8 years and older, persons with reduced physical, sensory, or mental capabilities, or persons with a lack of experience or knowledge when they are supervised or instructed concerning the safe use of the device and when they understand the resulting risks. Do not allow children to play with this device. The cleaning and user maintenance must not be carried out by children without supervision.
- You should only use spare parts that have been manufactured or approved by DewertOkin. Only these parts will guarantee a sufficient level of safety.
Selection and qualification of personnel
The HE150 should only be installed into the end product by someone who has
completed training in electronic motor assembly or has equivalent
qualifications. You should only install the HE150 when you are qualified to do
so. Otherwise, a properly qualified person should be found for this task.
Electrical safety
CAUTION
Electric shock
Be careful; there is a risk of electrical shock! Before installing, make sure
that you disconnect the external DewertOkin power supply for the HE150 from
the power outlet! The HE150 should not be opened! You must properly dispose of
malfunctioning or broken units.
Rating plate
- The rating plate shown is an example; The specifications for your HE150 may differ from this illustration.
Possible combinations
The HE150 can be used together with multiple individual drives, massage motors, and accessories that have been approved by DewertOkin. A tailored system consists of a combination of the control unit, single drive, massage motor, accessories, and a hand-held remote. DewertOkin has separate system instruction manuals containing the additional information and in-structions needed for these systems.
- Detailed information on combination possibilities can be requested directly from DewertOkin.
Description
The HE150 is a control unit and power supply for one or more DewertOkin drives. An external DewertOkin power supply unit is used to connect the HE150 to the main power. The HE150 is equipped with a built-in radio receiver.
Components
The housing of the HE150 has a connection for an external DewertOkin power
supply, as well as connections for single drives, massage motors, and various
accessories (refer to Chapter 3, “Possible combinations”).
- A Floor lighting (UBB, LED white)
- B Cable connection for POWER SUPPLY (e.g.: POWER SUPPLY HE-300 SMPS)
- C Connection for motor control cable (e.g.: OKIMAT 4 with single drive M1 /single drive M2)
- D Connection for single drive M3 (socket 4)
- E Connection for single drive M4 (socket 5)
- F Connection for massage motor (socket 6)
- G Multi-function port for optional accessories
- H Floor lighting (UBB, LED white) / Reset- / Pairing button BT-LED (LED blue)
- I Mounting plates (optional)
Technical specifications
Input voltage | 24 – 29 V DC |
---|---|
Current consumption at nominal operations | max. 6.0 A in intermittent duty, 2 |
min. ON / 18 min. OFF
max. 1.5 A in continuous duty (e.g. massage motors etc.)
Mode of operations 1)| Intermittent duty, 2 min. ON / 18 min. OFF
Protection class| III
Radiofrequency| 2.4 GHz
Protection degree| IP20
Dimensions and weight
Length x width x height| 196 mm x 116 mm x 40 mm
Weight| approx. 400 g
Ambient conditions for operation, storage, and transport
Transport/storage temperature| from -20 °C to +50 °C
from -4 °F to +122 °F
Operating temperature| from +10 °C to +40 °C
from +50 °F to +104 °F
Relative humidity| from 30% to 75%
Air pressure| from 800 hPa to 1060 hPa
Height| < 2000 m
- Mode of operation: intermittent duty 2 min. ON /18 min. OFF. This means that after the unit is operated with its rated load for up to two minutes it must then be paused for 18 minutes. The system can malfunction if this pause is not observed!
Installation
Safety notices to observe during installation
Basic safety rules must be followed to ensure that the end product can be
continually operated safely. These rules must be observed while using the end
product and while installing the HE150 in the end product.
Ensuring operational reliability during installation
The safety and reliability of the end product containing DewertOkin components
can be ensured by using the proper construction methods as described below.
Installation procedure
Before installing and connecting the HE150, make sure that you are observing
all of the safety notes found in the “Safety notice to observe during
installation” section.
Installation of the mounting plates
Screws should be screwed into the five mounting points on the two mounting
plates for attaching the HE150 to the end product. Two screws are used for
each of the two delivered mounting plates to attach them to the HE150.
- The drilling dimensions shown in Figure 5 only illustrate an example and are not necessarily authoritative for all applications.
CAUTION
You should only connect and disconnect the cables when they are completely
disconnected from any live current!
- Screw the mounting plates firmly onto the HE150 (as shown in Figure 6). Use at least two screws for each of the two mounting plates.
- A Mounting plates
- B Screws
- Mark the holes and drill the five screw points in the application.
- Tighten the screws on both mounting plates so the plates are firmly attached to the end product.
- Use screws meeting the requirements of DIN 7981 with 3.5 mm diameter and of suitable length (5 mm plus the screw-in depth into the end product, screw head: 5.5 mm diameter).
Mounting the HE150 to the OKIMAT 4
- A Mounting attachment
- B Guide for the HE150
- C Connection socket at the OKIMAT 4
- D Adapter
- E Cable guide
- F Junction cable
- G Adapter seat
- H HE150
- I Connection socket of the HE150
- Push the adapter’s locking clip into the OKIMAT 4’s mounting attachment (A) until you hear the clip snap in.
- Connect the connecting cable plug to the connecting socket of the OKIMAT 4 (C).
- Route the connecting cable (F) in the cable guide (E) of the adapter.
- Put the HE150 (from the top downwards) into the adapter’s guide (B).
- Connect the connecting cable plug to the connecting socket on the HE150 (H).
Electrical connection
CAUTION
Electric shock
Electrical components should be connected or disconnected only when the power
supply cord is unplugged.
- There is a delay after the supply voltage is applied before the device actually turns on. Wait at least 2 seconds before initial commissioning.
Routing the electrical cables
When routing the cables, be sure that:
- the cables cannot get jammed,
- no mechanical load (such as pulling, pushing or bending) will be put on the cables, and
- the cables cannot be damaged in any way.
Fasten all cables (especially the connecting cables) to the end product using sufficient kink prevention methods. Be sure that the design of the end product prevents the connecting cables from coming into contact with the floor during transport.
Connecting to the POWER SUPPLY
- A Cable connection for POWER SUPPLY (e.g.: POWER SUPPLY HE-300 SMPS)
- B Connection for motor control cable (e.g.: OKIMAT 4)
Information about creating your Operating Manual
The factual information contained within may be used when you are creating the end-product manual. The installation instructions do not contain all the information required for the safe operation of the end product. They only describe the assembly and operation of the HE150 as a partially assembled piece of machinery.
- When creating the operating instructions, remember that the installation instructions are intended for qualified specialists and are not for typical users of the end product.
General information
- You should only connect drives, massage motors, and accessories from DewertOkin to the HE150. Only DewertOkin components have been verified to work when combined together.
Avoiding damage caused by the floor lighting
CAUTION Risk of accident Do not look directly into this light and do not point the light into other people’s eyes.
Delayed start-up
After plugging the power plug into the power outlet:
- There is a delay after the supply voltage is applied before the device actually turns on. Wait at least 2 seconds before initial commissioning.
Avoiding electrical risks
CAUTION
Electric shock Make sure that all live (current-carrying) components and
connections on the control unit cannot be touched.
Power-on time / intermittent operations
The HE150 has been designed for intermittent operations. Intermittent
operation is an operational mode where the drive must pause after a specified
maximum period of operation (power-on time). This protects the drive from
overheating. Extreme overheating can cause a malfunction.
- The ratings plate specifies the maximum power-on time and the required pause intervals.
Avoiding electrical risks
CAUTION Risk of accident
Please follow these operating instructions carefully. You could be injured if
you do not follow these assembly instructions.
Emergency shut off of a connected drive or HE150
In an emergency, disconnect the power supply unit’s power plug to shut off the
connected drive. The power plug and the pluggable unit must always be
accessible during operations so that it is possible to shut down the drive or
HE150 at any time.
Avoiding cable damage
Be sure that your operating instructions inform the user about the possible
cable risks.
CAUTION Risk of accident The cables (particularly the connecting cable) should not be run over. To prevent injuries or damage to the drive and HE150, no mechanical strain should be placed on the cables.
Troubleshooting
This chapter describes troubleshooting methods for fixing problems. If you experience an error that is not listed in this table, please contact your supplier.
- Only qualified specialists who have received electrician training should carry out troubleshooting and repairs.
Problem | Possible cause | Solution |
---|---|---|
The drive, accessory or control unit is not functioning. | There is no mains | |
supply voltage. | Connect the mains power. |
Connect the connecting cable between the HE150 and the ex- ternal power supply
The drive, accessory or control unit is defective.| Please contact your
supplier or sales agent.
The hand-held remote control has not been programmed with the teach-in.| Carry
out the teach-in routine for the hand-held remote.
The hand-held remote batteries are empty.| Replace the batteries.
The drives or mas- sage motors are sud- denly not capable of movement.| The
overheating protection or sys- tem protection has been triggered.| Remove the
overload (change or remove the load).
Allow the system to rest for 20 to 30 minutes with the mains power unplugged.
Please contact your supplier or sales agent.
The unit’s fuse may have been trig- gered.| Please contact your supplier or
sales agent.
The hand-held remote batteries are empty.| Replace the batteries.
Radio interference| Try to re-establish the wireless connection.
There is no mains supply voltage.| Connect the mains power.
A cable has been disconnected (to the mains power, massage motors, drives or
accessory).| Check the cables and reinsert them, if required.
Maintenance
- The HE150 does not require maintenance.
Cleaning and care
- Clean the HE150 as needed using a dry antistatic cloth.
NOTICE
- Always disconnect the mains power plug from the power supply before you start to clean it.
- Never clean the HE150 in an automated washing system or with a high-pressure cleaner. Do not allow fluids to penetrate the lighting. Damage to the system could result.
- Do not use a cleanser that contains benzene, alcohol or similar solvents.
- Be sure that you do not damage the connecting cables during the cleaning.
Disposal
Packaging material
The packaging material should be sorted into recyclable components and then
disposed of in accordance with the appropriate national environmental
regulations (in Germany according to the recycling law KrWG from 01.06.2012;
internationally according to the EU Directive 2008/98/EC (Waste Framework
Directive WFD as of 12.12.2008)).
Components in the HE150
The HE150 consists of electronic components, cables and metal and plastic
parts. You should observe all corresponding national and regional
environmental regulations when disposing of the system. The disposal of the
end product is regulated in Germany by Elektro-G, internationally by the EU
Directive 2012/19/EC (WEEE) or by any applicable national laws and
regulations. The HE150 should not be disposed of with normal household waste!
EU Declaration of Conformity
- In compliance with Appendix IV of the EMC-Directive 2014/30/EU
- In compliance with Appendix IV of the LVD-Directive 2014/35/EU
- In compliance with Appendix VI of the EU RoHS Directive 2011/65/EU (incl. Commission delegated Directive (EU) 2015/863)
The manufacturer declares that the following product
HE150 with DewertOkin components
meets the requirements of the following EU directives: Electromagnetic Compatibility Directive 2014/30/EU Low Voltage Directive 2014/35/EU COMMISSION DELEGATED DIRECTIVE (EU) 2015/863 of 31 March 2015 amending Annex II to Directive 2011/65/EU of the European Parliament and of the Council as regards the list of restricted substances. Applied standards:
- EN 60335-1:2012/A11:2014
- EN 55014-1:2006/A1:2009/A2:2011
- EN 55014-2:1997/A1:2001/A2:2008
- EN 61000-3-2:2014
- EN 61000-3-3:2013
- EN 62233:2008
This declaration of conformity is no longer valid if constructional changes are made that significantly change the drive system (i.e., which influences the technical specifications found in the instructions or the intended use)!
- (Version 2.4GHz)
- In compliance with Appendix VI of the RED-Directive 2014/53/EU
- In compliance with Appendix VI of the EU RoHS Directive 2011/65/EU
- (incl. Commission delegated Directive (EU) 2015/863)
- The manufacturer: declares that the following product
HE150 with DewertOkin components
meets the requirements of the following EU directives:
RED Directive 2014/53/EU
COMMISSION DELEGATED DIRECTIVE (EU) 2015/863 of 31 March 2015 amending Annex
II to Directive 2011/65/EU of the European Parliament and of the Council as
regards the list of restricted substances.
Applied standards
- EN 60335-1:2012/A11:2014
- EN 55014-1:2006/A1:2009/A2:2011
- EN 55014-2:1997/A1:2001/A2:2008
- EN 61000-3-2:2014
- EN 61000-3-3:2013
- EN 62233:2008
- EN 62479:2010
- ETSI EN 300440 V2.1.1
- Draft ETSI EN 301489-1 V2.2.0
- Final Draft ETSI EN 301489-3 V2.1.1
This declaration of conformity is no longer valid if constructional changes are made that significantly change the drive system (i.e., which influences the technical specifications found in the instructions or the intended use)!
DewertOkin GmbH Weststraße 1 32278 Kirchlengern, Germany Phone: +49 (0)5223/979-0 Fax: +49 (0)5223/75182 http://www.dewertokin.de Info@dewertokin.de
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>