RenewAire EV 300 Indoor Unit Residential Light Commercial Owner’s Manual

July 31, 2024
RenewAire

RenewAire EV 300 Indoor Unit Residential Light Commercial

Note : There are multiple control options designed to address individual climate conditions. Please consult your local installer for the best installation controls for your climate.

ELECTRICAL DATA

HP Volts Hz Phase Watts FLA
0.2 120 60 Single 315 @ 297 CFM 3.3

SPECIFICATIONS

  • Ventilation Type:
    Static plate, heat and humidity transfer
    Typical Airflow Range: 150–300 CFM

  • Unit is HVI Tested/Certified per CSA C439 Protocol:
    Using one L-100-G5 Core

  • Standard Features:
    White painted cabinet
    Line-cord power supply
    Low-voltage circuit for controls
    Unit may be mounted in any orientation
    Cross-core differential pressure ports

  • Controls :
    Onboard 24VAC transformer/relay package

  • Filters :
    Total qty. 2, MERV 8, spun-polyester media: 10 1/2″ x 21 3/4″ x 1″

  • Unit Weight: 72 lbs.

  • Max. Shipping Dimensions & Weight (on pallet):
    34″ L x 44″ W x 34″ H
    115 lbs.

  • Units Per Pallet: 4

  • Motor(s):
    Qty. 1, Double-shaft standard motor

  • Accessories:

    • Backdraft damper: 8″

    • Automatic balancing damper: 4″, 5″, 6″

    • Motorized Dampers: 8″

    • Louvered wall vent 8″: taupe vinyl, galvanized, paintable galvanneal

    • Louvered wall vent with 8″ round duct connection: 12″ W x 8″ H

    • Hooded wall vent 8″: galvanized, paintable galvanneal

    • Digital time clock: wall mount (TC7D-W), in exterior enclosure (TC7D-E)

    • Carbon dioxide sensor/control: wall mount (CO2-W), duct mount (CO2-D)

    • IAQ sensor: wall mount (IAQ-W), duct mount (IAQ-D)

    • Motion occupancy sensor/control: ceiling mount (MC-C), wall mount (MC-W)
      Percentage timer control (PTL)
      Push-button point-of-use controls (PBL), PTL req’d.
      Percentage timer control with furnace interlock (FM)

    • MERV 13 filter: OA airstream (shipped loose)
      Electric duct heater: RH series (1–10 kW); designed for indoor ductwork installation only

UNIT PERFORMANCE

Airflow (CFM)| External Static Pressure (Inches Water Column)
---|---
170| 1.00
191| 0.90
214| 0.80
256| 0.70
278| 0.60
295| 0.50
311| 0.40

CORE PERFORMANCE

Airflow (CFM) Temp EFF% Total EFF% Winter/Summer
170 78 73/59
191 77 71/57
214 75 69/55
256 73 66/51
278 71 65/49
295 70 63/47
311 69 62/46

Note : These are core-only ratings and are not HVI certified. Total EFF% calculated at 35/33wb OA and 70/58wb RA (winter) and 98/78wb OA and 75/63wb RA (summer). HVI ratings apply to com-plete units only. This unit is HVI certified. See HVI certified ratings on pg. 48 of Single/Multi-Family Catalog and at hvi.org.

UNIT DIMENSIONS

AIRFLOW ORIENTATION
Available as shown in dimension drawing.

UNIT MOUNTING & APPLICATION
Can be mounted in any orientation. RA/EA airstream can be switched with OA/SA airstream.

ABBREVIATIONS

  • EA: Exhaust Air to outside
  • OA: Outside Air intake
  • RA: Room Air to be exhausted
  • SA: Supply Air to inside

INSTALLATION ORIENTATION
Unit may be installed in any orientation.

NOTE

  1. UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE ROUNDED TO THE NEAREST EIGHTH OF AN INCH.
  2. SPECIFICATIONS MAY BE SUBJECT TO CHANGE WITHOUT NOTICE.

Subject to change without notice: RENEWAIRE.COM | 1.800.627.4499