RenewAire EV130 Energy Recovery Ventilator Instruction Manual

May 15, 2024
RenewAire

RenewAire EV130 Energy Recovery Ventilator Instruction Manual
RenewAire EV130 Energy Recovery Ventilator

Note: There are multiple control options designed to address individual climate conditions. Please consult your local installer for the best installation controls for your climate.

ELECTRICAL DATA

HP Volts Hz Phase Watts FLA
0.1 120 60 Single 102 @ 130 CFM 1.3

SPECIFICATIONS

Ventilation Type: Static plate, heat and humidity transfer
Typical Airflow Range: 50–140 CFM

Unit is HVI Tested/Certified per CSA C439
Protocol: Using one L-50-G5 Core

Standard Features:
White painted cabinet Line-cord power supply Low-voltage circuit for controls Unit may be mounted in any orientation Cross-core differential pressure ports

Controls:
Onboard 24VAC transformer/relay package

Filters:
Total qty. 2, MERV 8, spun-polyester media: 10 1/2″ x 10 1/2″ x 1″
Unit Weight: 48 lbs.

Max. Shipping Dimensions & Weight (in carton):
32″ L x 22″ W x 18″ H 60 lbs.

UNIT PERFORMANCE

Airflow (CFM)| External Static Pressure (Inches Water Column)
---|---
78| 0.60
104| 0.50
125| 0.40
136| 0.30
153| 0.20
163| 0.10

Units Per Pallet: 8
Motor(s):
Qty. 1, Double-shaft standard motor

Accessories:

Backdraft damper: 6″, 8″
Automatic balancing damper: 4″, 5″, 6″
Motorized Dampers: 6″, 8″
Concentric Vent: 6″ (CV6-110)
Louvered wall vent 6″: white, brown
Digital time clock: wall mount (TC7D-W), in exterior enclosure (TC7D-E)
Carbon dioxide sensor/control: wall mount (CO2-W), duct mount (CO2-D)
IAQ sensor : wall mount (IAQ-W), duct mount (IAQ-D)

Motion occupancy sensor/control:
ceiling mount (MC-C), wall mount (MC-W)

Percentage timer control (PTL)
Push-button point-of-use controls (PBL), PTL req’d.
Percentage timer control with furnace interlock (FM)
MERV 13 filter: OA airstream (shipped loose)
Electric duct heater: RH series (1–5 kW); designed for indoor ductwork installation only

CORE PERFORMANCE

Airflow (CFM) Temp EFF% Total EFF% Winter/Summer
78 78 73/59
104 75 69/54
125 72 66/50
136 71 64/48
153 68 61/45
163 67 59/42

Note : These are core-only ratings and are not HVI certified. Total EFF% calculated at 35/33wb OA and 70/58wb RA (winter) and 98/78wb OA and 75/63wb RA (summer). HVI ratings apply to complete units only. This unit is HVI certified. See HVI certified ratings on pg. 47 of Single/Multi-Family Catalog and at hvi.org.

UNIT DIMENSIONS

AIRFLOW ORIENTATION
Available as shown in dimension drawing.

UNIT MOUNTING & APPLICATION
Can be mounted in any orientation. RA/EA airstream can be switched with OA/SA airstream.

**TOP VIEW
Dimension
LEFT VIEW
Dimension
FRONT VIEW
Dimension
RIGHT VIEW

**

ABBREVIATIONS

EA: Exhaust Air to outside
OA: Outside Air intake
RA: Room Air to be exhausted
SA: Supply Air to inside

INSTALLATION ORIENTATION

Unit may be installed in any orientation.

NOTE

  1. UNLESS OTHERWISE SPECIFIED, DIMENSIONS ARE ROUNDED TO THE NEAREST EIGHTH OF AN INCH.
  2. SPECIFICATIONS MAY BE SUBJECT TO CHANGE WITHOUT NOTICE