RenewAire SL75 Energy Recovery Ventilator Installation Guide
- June 1, 2024
- RenewAire
Table of Contents
RenewAire SL75 Energy Recovery Ventilator
Note: There are multiple control options designed to address individual climate conditions. Please consult your local installer for the best installation controls for your climate.
SPECIFICATIONS
- Ventilation Type: Static plate, heat and humidity transfer
- Typical Airflow Range : 30–130 CFM
- Unit is HVI Tested/Certified per CSA C439 Protocol: Using one L-30-G5 Core
- Standard Features: White painted cabinet Line-cord power supply or hard-wired to junction box (H) Low-voltage circuit for controls Unit may be mounted in any orientation Cross-core differential pressure ports
- Dial-A-Flow: balance and airflow adjustment Variable speed Boost-mode
- Controls: Onboard digital controller with independent variable speeds
- Filters: Total qty. 2, MERV 8, spun-polyester media: 7 1/2″ x 10 1/2″ x 1″
- Unit Weight: 35 lbs.
- Max. Shipping Dimensions & Weight (in carton): 31 1/4″ L x 22 3/8″ W x 14 3/8″ H 41 lbs.
- Units Per Pallet: 10
- Motor(s): Qty. 2, 120V EC motorized impellers
Accessories
- Backdraft damper: 6″, 8″
- Automatic balancing damper: 4″, 5″, 6″
- Motorized dampers: 6″, 8″
- Concentric vent : 6″ (CV6-110)
- Louvered wall vent 6 “: white, brown
- Louvered wall vent 8″: taupe vinyl, galvanized, paintable galvanneal Louvered wall vent with 8″ round duct connection: 12″ W x 8″ H Digital time clock: wall mount (TC7D-W), in exterior enclosure (TC7D-E)
- Carbon dioxide sensor/control : wall mount (CO2-W)
- IAQ sensor: wall mount (IAQ-W)
- Motion occupancy sensor/control: ceiling mount (MC-C), wall mount (MC-W) Push-button boost timer (PBT) Percentage timer control (PTL) Percentage timer control with furnace interlock (FM) Push-button point-of-use controls (PBL), PTL req’d.
- MERV 13 filter: OA airstream (shipped loose) Wall bracket kit
- Electric duct heater: RH series (1–4 kW); designed for indoor ductwork installation only
EC MOTOR OPERATING RANGE AND CORE PERFORMANCE
- = Actual tested sample points
| = Operating curves, airflow is held constant as static pressure varies
Factory settings
- High speed set to top curve
- Low speed set to ~90CFM at 0.4 in. w.g. ESP
Airflow (CFM)
| External Static Pressure (Inches Water Column)| Unit Power Consumption (Watts)| ****
Sensible EFF%
| ****
Total EFF% Winter/Summer
---|---|---|---|---
Max. Speed
138| 0.10| 135| 62| 54/36
131| 0.20| 134| 64| 55/38
125| 0.30| 133| 65| 57/40
117| 0.40| 132| 66| 59/42
110| 0.50| 131| 68| 60/44
102| 0.60| 129| 69| 62/46
95| 0.70| 126| 71| 64/48
87| 0.80| 123| 72| 66/51
78| 0.90| 119| 74| 68/53
68| 1.00| 114| 76| 70/56
49| 1.20| 102| 79| 75/61
21| 1.40| 64| 85| 81/69
Min. Speed
26| 0.10| 11| 84| 80/68
11| 0.20| 9| 87| 83/72
Notes:
- Watts is for the entire unit.
- Airflow performance includes the effect of a clean, standard filter supplied with the unit.
- Refer to CORES for specific operating point electrical data.
- These are core-only ratings and are not HVI-certified. Total EFF% calculated at 35/33wb OA and 70/58wb RA (winter) and 95/78wb OA and 75/63wb RA (summer). HVI ratings apply to complete units only. This unit is HVI-certified. See HVI certified ratings on pg. 46 of Single/Multi-Family Catalog and at hvi.org.3
ELECTRICAL DATA
Watts
|
Volts
|
Hz
|
Phase
| FLA
per motor
|
Minimum Circuit Amps
| Max Overcurrent Protection Device
---|---|---|---|---|---|---
53| 120| 60| 1| 0.85| 15| 15
LOW-PROFILE MULTI-FAMILY RESIDENTIAL/LIGHT COMMERCIAL
AIRFLOW ORIENTATION
- Available as shown in the dimension drawing.
UNIT MOUNTING & APPLICATION
Can be mounted in any orientation. RA/EA airstream can be switched with OA/SA
airstream.
- Subject to change without notice: RENEWAIRE.COM | 1.800.627.4499
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>