TFC GROUP TRADE03 Magnetic Filter 22mm Isolation Valve Instruction Manual

July 30, 2024
TFC Group

TFC GROUP TRADE03 Magnetic Filter 22mm Isolation Valve

Product Information

Specifications

  • Product No.: TRADE03
  • Product Name: Magnetic Filter for Central Heating Systems
  • Valve Size: 22mm
  • Manufacturer: TFC Group
  • Address: Tower House, Vale Rise, Tonbridge, Kent TN9 1TB
  • Contact: Telephone – 01732 351680, Fax – 01732 354445
  • Website: www.tfc-group.co.uk

Instructions

  • Only a qualified heating engineer should install the device.
  • Locate a suitable site for the filter for access and servicing.
  • Release and drain the heating system pressure.
  • Mark and cut 190mm out of the marked pipe section, and remove burrs.
  • Fit isolating valves on inlet and outlet pipes.
  • Introduce the diverter following the system flow direction, and tighten the nuts.
  • Fit filter body vertically, hand tighten locking collar.
  • Open isolation valves and turn on the heating system. Vent as needed.

Annual Servicing Requirement

  1. Isolate the heating system, and close both isolating valves.
  2. Unscrew the top knurled molding, and withdraw the magnetic bar with caution.
  3. Drain the filter chamber using the drain-off valve into a bucket.
  4. Clean filter body, plastic filter, and magnet cover with soapy water.
  5. Reassemble parts, and ensure a watertight seal.
  6. Bleed air from the inlet valve and air vent, check for leaks.

FAQ

  • Q: How often should I clean the filter?
  • A: It is recommended to clean the filter annually to maintain optimum efficiency.
  • Q: Can I install the filter myself?
  • A: Only a competent person like a qualified heating engineer should install the device for proper installation and safety reasons.

Component parts

a magnetic bar b filter body c cleaning cover
d filter body e drain-off valve f O ring
j colour cap h O ring i plastic filter
k rotating joint l snap ring m air-vent
n 22mm isolation valve r shim S spanner

Installation Instructions

Only a competent person such as a qualified heating engineer should install the device.

  1. Locate a suitable site for the filter to allow access and servicing. Return pipe is recommended, do not fit it between the boiler and the overflow on the open-vented systems.

  2. Release and drain the heating system pressure.

  3. Mark the pipe, using a suitable tool to cut 190mm out of the marked section and remove burrs.

  4. Fit the isolating valves provided onto both inlet and outlet pipes.

  5. Introduce the diverter, ensuring the arrow direction follows the heating system flow. Fit the diverter using the provided flat washers, and tighten the inner nuts fully. After that, tighten the outer compression nuts on the valves to ensure a watertight seal.

  6. Fit the filter body to the diverter and hand-tighten the locking collar (Do not over-tighten).
    The Filter body must be installed vertically.
    This filter’s magnetic bar is removable.

  7. Open the isolation valves and turn on the heating system.

  8. Vent as required by using the Top Air Bleed Valve.

Annual Servicing Requirement

To maintain optimum efficiency, annually cleaning is recommended.

  1. Isolate the heating system and close both of the two isolating valves. Prepare a suitable bucket to collect spillage.

  2. Unscrew the knurled molding at the top of the filter and withdraw the magnetic bar.
    CAUTION
    The bar is a very powerful 12000-gauss magnet. Keep away from personnel with heart pacemakers, any sensitive electronic devices, storage media, or magnetic bank cards.

  3. Drain the filter chamber into the bucket using the drain-off valve (e)

  4. Use the castellated wrench (s) supplied (or a strap wrench) to loosen the lower body (d) of the filter chamber. Unscrew the filter body fully, clean the body (d), the plastic filter (I), and the magnet cover (c) using hot, soapy water, and rinse with fresh water.

  5. Re-assemble the body (d) to the upper section (b), taking care to fit the plastic mesh filter (I) centrally inside body (d), and O-ring (f) onto the recess above the female threaded section of body (d). Fully hand-tighten the lower body (d) to the upper body (b). Ensure the drain-off valve is closed.

  6. Partly open the inlet valve (according to the flow direction arrow on the rotating joint (k)) and the brass air vent bleed screw, until all air is removed. Close the bleed screw, then fully open the inlet and outlet valves and check for leaks.

  7. Start the heating system.

WARNING: Please observe the safety instructions provided in this document. This filter contains a strong magnet. Care and attention should be taken at all times during installation and servicing. Do not place the magnetic core on any ferrous surfaces or near ferrous items.

Chemical dosing

  1. Isolate the boiler and close both isolating valves. Release air pressure by opening the Top Air Bleed valve. Prepare a suitable bucket to collect spillage.
  2. Drain the filter fully via the drain-off valve (e).
  3. Unscrew and remove filter body (d) as per 4. above. Fill body (d) with water treatment chemical (capacity 300ml). Re-assemble body (d) to body (b) as per 5. Above.
  4. Re-connect the filter to the heating system as per 6. above.
  5. Run the system for approximately 5 minutes to disperse chemical additives into the system. Repeat 1. – 5. if necessary to add any further water treatment chemicals into the system.

Attention: Do not allow chemicals to remain static in the filter for long periods.

Troubleshooting

Troubleshooting and problem-solving

Problem 1: Water is leaking from the filter
Solution: Turn off the system, and close the isolating valves. Perform the following checks:

  • Check all seals for location and condition.
  • Check the isolating valve nuts to ensure they are fully tightened.
  • Check the converter locking collar is firmly tightened and not cross-threaded.

Problem 2: Poor flow through the filter
Solution: Clean the filter when reduced flow is noted.

CONTACT

  • TFC Group Tower House, Vale Rise, Tonbridge, Kent TN9 1TB
  • Telephone: 01732 351680 Fax: 01732 354445 Web: www.tfc-group.co.uk

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals