ABOUT THIS MANUAL
This user manual is intended for the user and enables safe and appropriate handling of the product. It gives a general overview, as well as important technical data and safety information about the product. Before using the product, the user should read and understand the content of this user manual.
For the sake of better understanding and readability, this user manual might
contain exemplary pictures, drawings, and other illustrations. Depending on
your product configuration, these pictures might differ from the actual design
of your product.
1.2 ELATEC SUPPORT
In case of any technical questions, refer to the ELASTIC website (www.elatec.com) or contact ELASTIC technical support at: support- rfid@elatec.com
In case of questions regarding your product order or if you wish additional copies of this user manual, contact your Sales representative or ELASTIC customer service at: info-rfid@elatec.com
1.3 REVISION HISTORY
VERSION
| CHANGE DESCRIPTION|
EDITION
---|---|---
03| The chapter “Safety Information” updated| 08/2021
02| Editorial changes (layout, new template), product name update(“M” added)|
02/2021
01| First edition| 06/2020
INTENDED USE
TWN4 MultiTech 3 M LF integrates RFID (125 kHz) capabilities into a compact
but powerful reader. Its reduced size combined with excellent read/write
performance makes it the perfect reader for all applications where small size
and full performance matters, e.g. print solutions, healthcare applications,
driver identification, POS integration, and much more. Furthermore, TWN4
MultiTech 3 M LF provides access to most common host interfaces such as USB,
serial (TTL), or I²C which are readily accessible through an onboard
connector.
The product is intended to be integrated into a host device.
Any use other than the intended use described in this section, as well as any
failure to observe the safety information listed in this document, will be
considered misuse and will void the warranty. ELASTIC is not responsible for
any damage or injuries resulting from any misuse of the product.
SAFETY INFORMATION
Installation
- The installation of the product should be done by trained and qualified personnel only. Do not install the product by yourself.
- Metallic materials on or in direct vicinity to the product might reduce the reading performance of the product. In some circumstances, plastic screws should be preferred to metallic screws when installing the product. Refer to the installation instructions or integration manual of the product for more information.
Handling
-
Depending on your product configuration, the product might be equipped with one or more light-emitting diodes (LED).
Avoid direct eye contact with the blinking or steady light of the light- emitting diodes. -
The product has been designed for use under the following conditions:
- Temperature range: -25 °C – 80 °C (operating conditions)
- Relative humidity: 5% – 95% (non-condensing)
- Integration into a host device.
Any use of the product under different conditions might damage the product or alter its reading performance.
-
The use of other RFID readers or reader modules in direct vicinity to the product, or in combination with the product might damage the product or alter its reading performance. In case of doubts, contact ELATEC for more information.
-
The user is liable for the use of spare parts or accessories other than the ones sold or recommended by ELASTIC. ELASTIC is not responsible for any damage or injuries resulting from the use of spare parts or accessories other than the ones sold or recommended by ELASTIC.
-
Like most electronic devices, RFID systems generate electromagnetic waves that can vary in amplitude and frequency. It is generally known and accepted that some RFID devices might potentially interfere with personal medical devices, like pacemakers or hearing aids.
Users with a pacemaker or any other medical device should use TWN4 MultiTech 3 M LF carefully and refer to the information given by the manufacturer of their medical devices before using TWN4 MultiTech 3 M LF or any host device containing TWN4 MultiTech 3 M LF.
Maintenance and cleaning
-
Any repair or maintenance work should be done by trained and qualified personnel only.
Do not try to repair or carry out any maintenance work on the product by yourself.
Do not allow any repair or maintenance work on the product by an unqualified or unauthorized third party. -
The product does not need any special cleaning.
Do not use any detergents or other cleaning agents on the product.
Disposal
- The product must be disposed of in accordance with the EU directive on waste electrical and electronic equipment (WEEE) or
other applicable local regulations.
Product modifications
- The product has been designed, manufactured, and certified as defined by ELASTIC.
Any product modifications not expressly approved by ELATEC, including – but not limited to – modifications of antennas or other radio-related components, is not allowed and will void the warranty and all approvals granted to the product.
If you are unsure about any part of the safety information above, contact
ELASTIC support.
Any failure to observe the safety information above will be considered misuse
and will void the warranty. ELASTIC is not responsible for any damage or
injuries resulting from any misuse of the product.
TECHNICAL DATA
The reader module is equipped with the following antenna:
TWN4 MultiTech 3 M LF – bottom view
LF antenna (125 kHz)
Dimensions: 49 x 34 mm / 1.93 x 1.34 inch
Number of turns: 3
For more information, refer to the related product data sheet or other
technical documents.
MODE OF OPERATION
5.1 OPERATING MODE
In order to start operating TWN4 MultiTech 3 M LF, it simply has to be connected directly to a host device.
5.2 POWER-UP
In case of an external power supply unit is used, the following requirements
must be satisfied:
- Limited power source according to the safety norms listed in the respective declaration(s) of conformity
- Short-circuit current < 8 A
Once TWN4 MultiTech 3 M LF is connected to the host, it detects the type of communications cable (e.g. USB or RS-232), with which it is connected to the host. In the case of RS-232: Additionally, the RS-232 is sending a version string via RS-232 to the host.
5.3 ENUMERATION
This is only applicable for the USB version: Once the device has been powered
up, it is waiting for completion of the enumeration by
the USB host. As long as the device is not enumerated, it is entering a
minimum power consumption mode, where both LEDs are
turned off.
5.4 INITIALIZATION
After powering up and enumeration (in USB mode), the device is turning on the built-in transponder-reader logic. The green LED is turned on permanently. Some reader modules need some kind of initialization, which is performed in this step. After successful initialization, the device sounds like a short sequence, which consists of a lower tone followed by a higher tone.
5.5 NORMAL OPERATION
As soon as the reader module has completed the initialization, it is entering normal operation. During normal operation, the reader module is searching for a transponder continuously.
5.6 DETECTION OF A TRANSPONDER
If a transponder is detected by the reader module, the following actions are performed:
- Send the ID to the host. By default, the USB device sends by emulating keystrokes of a keyboard. An RS-232 device sends the ASCII code of an ID.
- Sound a beep.
- Turn off the green LED.
- Blink the red LED for two seconds.
- Turn on the green LED.
Within the two seconds timeout, where the red LED is blinking, the
transponder, which just has been recognized will not be accepted again. This
prevents the reader module from sending identical IDs more than one time to
the host.
If during the two seconds timeout of the red LED a different transponder is
detected, the complete sequence restarts immediately.
5.7 SUSPEND MODE
The USB version of the reader supports the USB suspend mode. If the USB host is signaling to suspend via the USB bus, the reader is turning off most of its power-consuming peripherals. During this operation mode, no detection of transponders is possible and all LEDs are turned off. Once the host is resuming to normal operation mode, this is also signaled via the USB bus. Therefore, the reader will resume normal operation, too.
COMPLIANCE STATEMENTS
6.1 EU
TWN4 MultiTech 3 M LF is in compliance with the EU directives and
regulations as listed in the respective declaration of conformity.
6.2 FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation.
Caution
The Federal Communications Commission (FCC) warns the users that changes or
modifications to the unit not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
FCC §15.105 (b)
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC ID: WP5TWN4F8
6.3 IC
This device complies with Industry Canada’s license-exempt RSS. Operation is
subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may
cause undesired operation of the device.
IC: 7948A-TWN4F8
6.4 RF EXPOSURE COMPLIANCE
RF exposure statement (mobile and fixed devices)
This device complies with the RF exposure requirements for mobile and fixed
devices. However, the device shall be used in such a manner that the potential
for human contact during normal operation is minimized.
APPENDIX
A – TERMS AND ABBREVIATIONS
TERM
|
EXPLANATION
---|---
FCC| Federal Communications Commission
IC| Industry Canada
LF| low frequency
RFID| radio frequency identification
WEE| Waste of electrical and electronic equipment.
Refers to Directive 2011/65/EU of the European Parliament and of the Council
of the European Union
B – RELEVANT DOCUMENTATION
ELASTIC documentation
- ELASTIC quick start guide
- TWN4 MultiTech 3 M LF data sheet
- TWN4 MultiTech 3 M LF integration manual
- TWN4 MultiTech 3 technical handbook
RFID Systems
ELATEC GMBH
Zeppelinstr. 1 • 82178 Puchheim • Germany
P +49 89 552 9961 0 • F +49 89 552 9961 129 • E-mail: info-
rfid@elatec.com
elatec.com
Elatec reserves the right to change any information or data in this document without prior notice. Elatec declines all responsibility for the use of this product with any other specification but the one mentioned above. Any additional requirement for a specific customer application has to be validated by the customer himself at his own responsibility. Where application information is given, it is only advisory and does not form part of the specification. Disclaimer: All names used in this document are registered trademarks of their respective owners. © 2021 ELATEC GmbH – TWN4 MultiTech 3 M LF user manual DocRev3 – 08/2021
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>