MAJESTIC EYF18 Gas Log Set
Product Information
Specifications :
- Model: MAJESTIC EYF30-R
- Types: Unvented Gas Log Heater or Vented Decorative Appliance
- Models: EYF18, EYF24
- Control Type: Manual or Millivolt
- Fuel Type: Natural Gas or Propane/LPG
Product Usage Instructions
Important Safety Information:
It is crucial to follow all safety instructions provided in the manual to
prevent fire hazards and ensure user safety. Please read and understand all
warnings before proceeding with the installation.
-
Getting Started:
Before using the appliance, carefully read through the installation and operation instructions in the manual. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. -
General Installation Information:
Ensure that provisions for adequate combustion and ventilation air are provided when installing the unvented gas log heater. Refer to Page 6 of the manual for detailed instructions on ventilation requirements.
Operating Instructions :
Follow the specific lighting instructions based on the control type of your
appliance:
- Manual Control Lighting Instructions: Follow the steps outlined in the manual for manually lighting the gas log set.
- Millivolt Control Lighting Instructions: Refer to the manual for lighting instructions specific to millivolt control.
- Match Lighting Instructions: Detailed instructions for match lighting can be found in the manual.
Maintenance :
Regular maintenance is essential for optimal performance. Refer to the
maintenance section in the manual for guidance on cleaning and upkeep of your
gas log set.
Troubleshooting :
If you encounter any issues with your appliance, refer to the troubleshooting
section in the manual for common problems and solutions
Replacement Parts:
If replacement parts are needed, consult the manual for a list of genuine
replacement parts suitable for your MAJESTIC EYF30-R gas log set.
Frequently Asked Questions (FAQ):
-
Q: Can I use this gas log set with both natural gas and propane/LPG?
A: Yes, the MAJESTIC EYF30-R is compatible with both natural gas and propane/LPG fuel types. Ensure to follow the specific instructions for each fuel type as outlined in the manual. -
Q: How often should I perform maintenance on the gas log set?
A: Regular maintenance should be conducted as per the guidelines provided in the manual. It is recommended to clean and inspect the appliance periodically to ensure proper functioning. -
Q: What should I do if I smell gas when operating the appliance?
A: If you detect a gas odor, immediately turn off the appliance, ventilate the area, and contact a qualified technician to inspect for any leaks or issues with the gas log set.
This Owner’s Manual is provided and hosted by Appliance Factory Parts.
MAJESTIC EYF30-R Owner’s Manual
Shop genuine replacement parts for MAJESTIC EYF30-R
Find Your MAJESTIC Fireplace Parts – Select From 585 Model
Unvented Gas Log Heater or Vented Decorative Appliance
Installation and Operating Instructions
- Models: EYF18, EYF24
- Natural Gas or Propane/LPG Control Type : Manual or Millivolt
WARNINGS
- If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
- This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Page 6.
- INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
- Thank you and congratulations on your purchase of a Gas Log Set
- PLEASE READ THE INSTALLATION AND OPERATION INSTRUCTIONS BEFORE USING THE APPLIANCE!IMPORTANT: Read all instructions and warnings carefully before starting installation.
- Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
IMPORTANT SAFETY INFORMATION
-
INSTALLER
Please leave these instructions with the appliance. -
OWNER
Please retain these instructions for future reference. -
WARNING
-
Any change to this heater or its controls can be dangerous.
-
Improper installation or use of the heater can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning.
-
Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns.
-
Do not use a blower insert, heat exchanger insert or other accessory, not approved for use with this heater where applicable.
-
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
-
Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition.
-
Young children should be carefully supervised when they are in the same room with the appliance.
-
Do not place clothing or other flammable material on or near the appliance.
-
Any safety screen or guard removed for servicing an appliance, must be replaced prior to operating the heater.
-
Installation and repair should be done by a qualified service person.
-
To prevent malfunction and/or sooting, an unvented gas heater should be cleaned before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is imperative that control compartments, burners and circulating air passageways be kept clean.
-
For propane/LP insert, do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.
-
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.l/NFPA54.
-
This unit complies with the latest edition of ANSI Z21.11.2, Unvented Heaters and also complies with ANSI Z21.60 Decorative Vented Appliances for Solid Fuel Burning Fireplaces. State and local codes may only allow operation of this appliance in a vented con-figuration. Check your state or local codes. For vented operation, see Vented Instructions in this manual.
-
Do not install the heaters in a bathroom or bedroom.
-
Correct installation of the ceramic fiber logs, proper location of the heater, and annual cleaning are neces-sary to avoid potential problems with sooting. Sooting, resulting from improper installation or operation, can settle on surfaces outside the fireplace. See log place-ment instructions for proper installation.
-
Avoid any drafts that alter burner flame patterns. Do not allow fans to blow directly into fireplace. Do not place a blower inside burn area of firebox. Ceiling fans may create drafts that alter burner flame patterns. Sooting and improper burning will occur.
-
CAUTION : Candles, incense, oil lamps, etc. produce combustion by-products including soot. Vent-free appliances will not filter or clean soot produced by these types of products. In addition, the smoke and/or aromatics (scents) may be reburnt in the vent-free ap-pliance which can produce odors. It is recommended to minimize the use of candles, incense, etc. while the vent-free appliance is in operation.
-
This is an unvented gas-fired heater. It uses air (oxy-gen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Page 6
CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, the insert may not have been installed properly. Get fresh air at once! Have the insert inspected and serviced by a qualified service person. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes. Propane/LP gas and natural gas are both odorless. An odor-making agent is added to each of these gases. The odor helps you detect a gas leak. However, the odor added to these gases can fade. Gas may be present even though no odor exists. -
Keep room area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
-
Unvented gas heaters are a supplemental zone heater. They are not intended to be a primary heating appliance. Water vapor produced by an unvented heater can create moisture problems in a home when operated for extended periods of time.
-
During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or bonding agents. These chemicals are not harmful but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance; possibly causing headaches or eye or lung irritation. This is a normal and temporary occurrence. The initial break-in operation should last two to three hours with the burner at the highest setting. Provide maximum ventilation by opening windows or doors to allow odors to dissipate. Any odors remaining after this initial break-in period will be slight and will disappear with continued use.
-
Input ratings are shown in BTU per hour and are for elevations up to 2,000 feet. For elevations above 2,000 feet, input ratings should be reduced 4 percent for each 1,000 feet above sea level. See the National Fuel Gas Code.
- We recommend that our gas hearth products be installed and serviced by professionals who are certified in the U.S. by the National Fireplace Institute® (NFI) as NFI Gas Specialists.
- Attention Massachusetts Residents:
- This product must be installed by a licensed gas fitter.
-
The heater and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
-
The heater must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).22. Do not use this room heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.
-
This appliance must not be used with glass doors in the closed position. This can lead to pilot outages and severe sooting outside the fireplace.
-
Never burn solid fuels in a fireplace where a unvented room heater is installed.
-
Always have a fireplace screen in place when the appliance is in operation and , unless other provisions for combustion air are provided, the screen shall have an opening(s) for induction of combustion air.
This appliance may be installed in an after-market, permanently located,
manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases.
WARNING
Never connect unit to private (non-utility) gas wells. This gas is commonly
known as wellhead gas.
CODES
- Adhere to all local codes or, in their absence, the latest edition of THE NATIONAL FUEL GAS CODE ANSI Z223.1 or NFPA54 which can be obtained from…
- American National Standards Institute, Inc. 1430 Broadway
- New York, NY 10018 or National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269
GETTING STARTED – FEATURES and SPECIFICATIONS
- WARNING
- Gloves are recommended when handling ceramic fiber logs to prevent skin irritation from loose fibers.
- Logs are fragile – handle with care.
MAKE SURE YOU HAVE RECEIVED ALL PARTS:
- Check your packing list to verify that all listed parts have been received. You should have the following:• Unvented gas log burner assembly
- Plastic bag containing crushed volcanic rock
- Installation/operating instructions
- Two (2) anchoring screws
- Ceramic Fiber or Refractory Cement Logs
- Grate
- The millivolt controlled version of this heater is the only style designed to be operated with optional devices for ON/OFF functions. The following options may be used with the millivolt controlled heater. These options are not packaged with the log set.
- Hand held Remote with receiver
- Wall thermostat with 15′ wire
- Wall switch with 15′ wire
- Hand held Thermostat Remote with receiver
- Carefully inspect the contents for shipping damage. If any parts are missing or damaged, immediately inform the dealer from whom you purchased the appliance. Do not attempt to install any part of the appliance unless you have all parts in good condition.
WHAT YOU WILL NEED FOR INSTALLATION:
- You must have the following items available before pro-ceeding with installation:
- External regulator (for propane/LPG and 1/2 lb. natural gas systems only)
- Piping which complies with local codes
- Screwdriver
- Drill with 5/32 bit
- Manual shutoff valve
- Pipe sealant approved for use with propane/LPG (Resistant to sulfur compounds)
- Pipe wrench or appropriate size crescent wrench set
- Tee joint.
- Sediment trap
GAS PRESSURES
Control | Fuel | Manual | Millivolt |
---|---|---|---|
Regulator Pressure | Nat. | 4.0” w.c. | 3.5” w.c. |
Pilot Regulator | Nat. | n/a | 3.5” w.c. |
Max. Inlet Pressure | Nat. | 10.5” w.c. | 10.5” w.c. |
Min. Inlet Pressure | Nat. | 5.0” w.c. | 5” w.c. |
Regulator Pressure | LP | 10.0” w.c. | 10.0” w.c. |
Max. Inlet Pressure | LP | 13.0” w.c. | 13.0” w.c. |
Min. Inlet Pressure | LP | 11.0” w.c. | 11.0” w.c. |
NOTE : An external regulator is required to reduce supply pressure to a
maximum of 13” w.c.
GAS SPECIFICATIONS
| | | Gas Rate
---|---|---|---
Max.Input| Min. Input
Model| Fuel| Control| BTU/h| BTU/h
EYF18NM| Nat.| Manual| 30,000| 18,000
EYF18PM| LP| Manual| 30,000| 22,500
EYF18NV| Nat.| Millivolt| 30,000| 20,000
EYF18PV| LP| Millivolt| 30,000| 24,500
EYF24NM| Nat.| Manual| 36,000| 19,000
EYF24PM| LP| Manual| 36,000| 25,000
EYF24NV| Nat.| Millivolt| 36,000| 24,000
EYF24PV| LP| Millivolt| 36,000| 29,000
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches or
batteries.
Manual control has three (3) positions:
- OFF – All gas to the gas logs is shut off at the valve. IGN – Valve position to light/maintain a standing pilot. HI/LOW – Variable position corresponding to desired flame height (heat input)
- Millivolt control has four (4) positions:
- OFF – All gas to the gas logs is shut off at the valve. IGN – Valve position to light/maintain a standing pilot. ON – Valve position to turn ON/OFF log set with remote switch/thermostat.
- HI/LOW – Variable position to control flame height (heat output).
- PILOT
- The gas log heater is fitted with a specially designed safety pilot light (ODS assembly) which senses the amount of oxygen available in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot can only be relit when adequate fresh air is available.
THERMAL GENERATOR
The millivolt gas log pilot is fitted with a millivolt generator to provide
power for remote activation.
- ADEQUATE COMBUSTION AND VENTILATION AIR
- This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.
- The National Fuel Gas Code, (ANSI Z223.1/NFPA54), defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 BTU per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space, and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 BTU per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space.
UNUSUALLY TIGHT CONSTRUCTION IS DEFINED AS CONSTRUCTION WHERE:
- walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of 1 perm (6 x 1011 kg per pa/sec-m2) or less with openings gasketed or sealed;
- weather striping has been added on openable windows and doors, and
- caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.
- The following formula can be used to determine the maximum heater rating per the definition of unconfined space:
- Consider two connecting rooms with an open area between, with the following dimensions:
- L1 = 15Z\x Ft., L2 = 12 Ft., W = 12 Ft., H = 8 Ft.
- If there were a door between the two rooms the calculation would be based only on the room with the heater.
WARNING
If the area in which the heater may be operated is smaller than that defined as
an unconfined space or if the building is of unusually tight construction,
provide adequate combustion and ventilation air by one of the methods
described in the National Fuel Gas Code, ANSI Z223.1/NFPA54, Air for
Combustion and Ventilation or applicable local codes.
FIREPLACE and HEARTH DIMENSIONS
- WARNINGThis appliance has been specifically tested and design certified for installation only in a solid-fuel burning fireplace including factory-built UL127 fireplaces and masonry fireplaces, or in a listed ventless firebox (see below).
- Exception: DO NOT install this appliance in a factory-built fireplace that includes instructions stating that it has not been tested or should not be used with unvented gas logs. v
- Use manufacturer’s installation and clearance requirements as defined in their manual.
- The EYF Series unvented room heater is approved for installation into the following unvented fireplaces:
- GCUF(32,36,42) and VFR(32,36,42) Series Fireboxes
- The EYF Series unvented room heater may also be in-stalled into a Ventless Firebox Enclosure for Gas Fired Decorative Type Unvented Room Heaters per ANSI Z21.91b.2004, as long as firebox hearth dimensions meet the minimum hearth dimensions shown below.
Figure 2 – Hearth Minimum Dimension for Solid Fuel Burning Fireplaces and
UL127 Factory Built Fireplaces
WARNING
Barriers such as the bottom of a glass door frame placed in front of a gas
log set can change the air flow characteristics of the fireplace which in turn
can cause the unit to overheat and malfunction.
- IMPORTANT INFORMATION FOR THE INSTAL- LATION OF THIS GAS LOG SET IN A FIRE- PLACE WITH A RESTRICTIVE BARRIER
- The following are guidelines for placing a gas log set in a fireplace that has a restrictive barrier along the bottom front opening of the fireplace. Some examples of barri-ers are glass/screen door frames and sunken/recessed fireplaces.
- Height of Restriction (x)
- No Restriction 1/2” to 1Z\x”
- Greater than 1Z\x” to 3” Greater than 3”
- Minimum Depth of Fireplace/Firebox 13”
- 16”
- 16”
-
- Any barrier greater than 3” placed in front of the gas log set is not recommended by the manufacturer.
- NOTE: Non combustible material such as refractory brick may be used to line the floor of the fireplace in order to raise the height of the gas log set in relation to a restrictive barrier. If the unit is raised, the minimum height dimension listed in the homeowner’s manual must not be exceeded.
- NOTE: If the log set is equipped with a remote receiver, a restrictive barrier may reduce the battery life by increasing the ambient temperature inside the fireplace. Placement of the receiver outside of the fireplace will extend the battery life.
CLEARANCE and HEIGHT REQUIREMENTS
WARNING
-
The dimensions shown in Figures 4 through 10 and defined in the fireplace manufacturer’s instructions are minimum clearances to maintain when installing this heater. Left and right clearances are determined when facing the front of the heater.
-
When heater is installed into a ventless firebox, minimum clearances, as specified by the ventless firebox manufacturer, must be met.
-
Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard.
-
Sidewall and ceiling clearances: The sides of the fire-place opening must be at least 16″ from any combustible wall. The ceiling must be at least 42″ from the top of the fireplace opening.
-
Heat resistant material (minimum requirements) with no wooden mantel or other combustible projection:
-
To install the gas logs into a fireplace with no wooden mantel, shelf or other combustible projection above the fireplace opening, measure the heat resistant material height, per
-
Figure 5, then see TABLE A.
-
Heat resistant materials such as slate and marble must be at least 1/2″ thick. Sheet metal should not be installed onto combustible material.
-
IMPORTANT: If you cannot meet these minimum clearances you must operate the heater with chimney flue damper open. See Installing Vented Applications found on page 16.
Table A –
Heat Resistant Material Requirements with Nao Mantel or Combustible Projection
Heat Resistant Material Measurement| EYF24/18 Requirements for Safe
Installation
---|---
20″ or more| Hood not required
8″ to less than 20″| Extend heat resistant material to 20″ or install hood.
Figure 6
Less than 8″| Extend heat resistant material to at least 8″ and install hood.
Figure 6. OR, extend heat resistant material to a height of at least 20″.
INSTALLATION
Heat resistant material (minimum requirements) with wooden mantel or other combustible projection: To install the heater with a wooden mantel, shelf or other combustible projection above, first measure the heat resistant material shown in Figure 6, then refer to Table B.
Table B –
Heat Resistant Material Heights and Mantel Location
Heat Resistant Material Measurement| EYF24/18 Requirements for Safe
Installation with Wooden Mantel, Shelf or Other Combustible Projection
---|---
20″ or more| Hood not required. Figure 6
8″ to less than 20″| Install hood (CABR/CABL) and refer to Figure 7 ; OR
extend heat resistant material to at least 12″ and refer to Figure 8.
Less than 8″|
- Extend heat resistant material to at least 8″ and install hood (CABR/CABL), refer to
- Figure 6. OR, extend heat resistant material to a height of at least 12″ and refer to Figure 8
Example: A mantel may project from the wall a maximum of 2Z\x” at a minimum of 13″ above the opening and a maximum of 10″ at a minimum of 18″ above the opening.
Example: The bottom of the mantel may project from the wall a maximum of 10″ at a minimum of 32″ above the opening.
EYF Series Unvented Gas Log Set
FLOOR CLEARANCE
- The gas log heater must be installed at least 5″ above any combustible flooring material, such as carpeting or tile, which is closer than 14″ to the base of the fireplace. The minimum distance must be maintained from the top surface of carpeting, tile, etc. Figure 9 OR,
- The gas log heater may be installed nearer to the floor if a minimum of 14″ of noncombustible material such as slate or marble is installed between the base of the fireplace and the combustible flooring. Figure 10
FIREPLACE PREPARATION
-
WARNING
Before installing in a solid fuel burning fireplace, The chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. -
WARNING
This appliance is for installation only in a solid fuel burning fireplace (masonry fireplace or manufactured fireplace) with a working flue and constructed of noncombustible material.
Exception: DO NOT install this appliance in a factory-built fireplace that includes instructions stating that it has not been tested or should not be used with unvented gas logs. -
BEFORE FULLY INSTALLING THE UNIT:
-
Turn OFF the gas supply to the fireplace or firebox.
-
Seal any fresh air vents and/or ash clean-out doors located on the floor or wall of the fireplace. If left un-sealed, drafting may cause pilot outage or sooting. Use a heat resistant sealant. Do not seal the chimney flue damper.
-
INSTALLING VENTED APPLICATIONS
-
Manual and millivolt controlled gas logs may be installed as a vented decorative log set in compliance with ANSI Z21.60 and National Fuel Gas Code, Section 6.6 Since, the gas logs are operated with the damper open, non-combustible material and minimum mantel requirements do not apply.
BEFORE INSTALLING THE APPLIANCE:
- Turn off gas supply to fireplace or firebox.
- Have the fireplace floor and chimney professionally cleaned to remove ashes, soot, creosote or other ob-structions. Have this cleaning performed annually after installation.
- Seal any fresh air vents or ash clean-out doors located on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat-resistant sealant. Do not seal chimney flue damper.
- Install and operate the appliance as directed in this manual.
DAMPER STOP INSTALLATION:
- A damper stop must be provided with the unit. Contact your dealer to obtain one. The damper stop must be installed as shown in Figure 11 to prevent full closure of the fireplace damper blade and provide a minimum 29 square inch flue opening.
WARNING
The fireplace and gas logs function as a system. If the fireplace is spilling
into the room (check with a match or a smoke stick), repos damper clamp until
a positive draft i ed by opening the damper. If negative pressure in home
prevents having a positive draft, contact your dealer for assistance.
PLACE and SECURE APPLIANCE ASSEMBLY PROCEDURE:
Figure 12
- Center the gas log unit in the fireplace or firebox.
- Install Grate: Insert longest middle grate bar in one of the two square holes in control panel. Be sure grate is centered. Sit horizontal bar inside two (2) hooks on front of control panel. Make certain front feet of grate are located inside front edge of fireplace or firebox.
- Anchor holes are located on the flange of the unit. After centering the burner correctly, mark the hole positions on the fireplace/firebox floor. Drill two (2) 5/32″ diameter holes approximately 1Z\x” deep.
- Anchor the unit to the fireplace/firebox floor using the screws provided.
WARNING
- You must secure the gas log heater to the fireplace floor. If not, the entire unit may move when you adjust the controls. Movement of unit may cause shifting of the gas logs which leads to sooting and improper burning.
- Special care is required if you are installing the unit into a sunken fireplace. You must raise the fireplace floor to allow access to gas log controls. This will insure adequate air flow and guard against sooting. Raise the fireplace floor using noncombustible materials, as described in Placement in a Fireplace with Restrictive Barrier on Page 10.
WARNING
- Use new black iron or steel pipe. Internally tinned copper or copper tubing can be used per National Fuel Code, section 2.6.3, providing gas meets hydrogen sulfide limits, and where permitted by local codes. Gas piping system must be sized to provide minimum inlet pressure (Listed on Data Plate) at the maximum flow rate (BTU/Hr). Undue pressure loss will occur if the pipe is too small.
- A manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8″ NPT pressure tapping point should be installed upstream of the appliance. Figure 13
- NOTICE: A qualified gas appliance installer must connect the heater to the gas supply. Consult all local codes.
- IMPORTANT: Hold heater valve firmly with a wrench to prevent movement when connecting to inlet pipe.
Always use an external regulator for all propane/LPG heaters and high pressure one to two-pound systems only, to reduce the supply tank pressure to a maximum of 13″ w.c. This is in addition to the internal regulator in the heater valve.
WARNING
CHECK GAS TYPE: The gas supply must be the same as stated on the heater’s
rating plate. If the gas supply is different, DO NOT INSTALL THE HEATER.
Contact your dealer for the correct model.
WARNING
Connecting directly to an unregulated propane/LPG tank can cause an
explosion.
The heater gas inlet connection is a 3/8″ NPT at the valve. All units have the
inlet connection on the right side, when you face the unit. To connect from
the opposite side, route the pipe under the rear portion of the unit.
When tightening up the joint to the valve, hold the valve securely to prevent
movement.
MANUAL CONTROL
Figure 14
The pressure regulator is preset and locked to dis-courage tampering. If the
pressure is not as specified, replace the regulator with the correct part from
the parts list in this manual.
MILLIVOLT CONTROL
Figure 15
- The valve regulator controls the burner pressure which should be checked at the pressure test point.
- Turn captured screw counter clockwise two or three turns and then place tubing to pressure gauge over test point (Use test point “OUT” closest to control knob). After taking pressure reading, be sure and turn captured screw clockwise firmly to re-seal. Do not over torque. Check for gas leaks.
ELECTRICAL WIRING – MILLIVOLT
- WARNING
- Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
CONNECTING OPTIONAL WALL SWITCH OR THERMOSTAT
- Use 18 AWG, two-wire cable, 20 feet maximum length.
- At one end of the cable, connect both wires to the wall switch or thermostat. At the other end, connect one wire to TP/TH and one wire to TH. The color of the wires does not matter. Or you can hook the wall switch or thermostat to wires on the unit.
CONNECTING OPTIONAL REMOTE RECEIVER
FOLLOW INSTRUCTIONS SUPPLIED WITH THE REMOTE
- Connect the wires to the two .25″ male connectors located on the left side of the valve when facing the unit. Page 19, Figure 16. Do not let wire touch grate or burner.
- Stick velcro pads with self-adhesive backing to the right side of remote receiver and to the left side of the unit. Figure 17
- Attach remote receiver with velcro pads. Control switch must face forward.
NOTE: Heat reduces battery life. You can protect the receiver and extend battery life by mounting the receiver in a wall or other location outside the fireplace.
CHECKING SYSTEM OPERATION
The millivolt system and individual components may be checked with a millivolt
meter having a 1-1000 mV range. Conduct each check shown in chart by
connecting meter test leads to terminals as indicated.
- Complete Millivolt System Check (“A” Reading – Thermostat contacts CLOSED – Control knob “ON” – Main burner should turn ON)
- If reading is more than 175 millivolts and the automatic valve still does not come on, replace the control.
- If the closed circuit reading (“A” reading) is less than 175 millivolts, determine cause for low reading, proceed to Section B.
- Thermopile Output Reading Check(“B” Reading – thermostat contacts OPEN – Main burner OFF
- Check gas pressure to the unit. If gas pressure is within minimum and maximum on data plate, then check pilot voltage, 500 millivolts minimum. If the minimum millivolt reading is not obtainable, replace pilot.
Check Test| To Test| Connect Meter Leads To
Terminals| Switch or Thermostat Contacts| Meter Reading Should
Be
---|---|---|---|---
A| Complete System| 2 & 3| Closed| Minimum 175
B| Thermopile Output| 1 & 2| Open| Minimum 500
LOG PLACEMENT
WARNING
-
The positioning of the logs is critical to the safe and clean operation of this heater. Sooting and other problems may result if the logs are not properly and firmly positioned in the appliance. Never add additional logs or embellishments such as pine cones, vermiculite or rock wool to the heater. Only use the logs supplied with the unit.
Failure to position the parts in accordance with diagrams below or to use only parts specifically approved for this heater may result in property damage or personal injury. -
Before you begin — This unit is supplied with a four ceramic fiber log units. Do not handle the log unit with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After handling the log unit, wash your hands gently with soap and water to remove any traces of fibers.
INSTALL EYF24-F LOG UNIT ON BURNER Figure 18
- Install Main Log (#1) on middle and rear supports of base. Tabs should fit inside log center opening. Check log position and stability.
- Install Front Log (#2) in front of burner and behind grate.
- Rest rear end Top Left Log (#3) in the indention on the main log. Line up hole in bottom of Top Left Log (#3) with slot on Front Log.
- Position rear end of Top Right Log (#4) on indention of main log. Rest front end of Top Right Log (#4) on front lot.
PLACE THE DECORATIVE ROCKWARNING
WARNING
- DO NOT sprinkle volcanic rock on the logs or around the pilot or the main burner. This may cause sooting. Only place volcanic rock on the floor of the fireplace.
- During initial operation of the new heater, burning logs will give off a paper burning smell and orange flames will be present. Simply open the windows for a few hours to vent the odor.
PLACE EYF18-R LOGS
- Place Rear Log (#1) on rear support. Figure 19
- Place Middle Log (#2) on middle support. Figure 20
- Place Front Log (#3) in between burner and grate. Figure 21
- Rest Top Log (#4) in front and middle log cutouts. Figure 22
NOTE: Logs #1, #2 and #3 have ridges on the bottom which secure the logs to burner frame. After installing each log, check to be sure it is stable.
PLACE EYF24-R and EYF30-R LOG SETS
- Place Rear Log (#1) on rear support. Figure 24
- Place Middle Log (#2) on middle support. Figure 25
- Place Front Log (#3) in between burner and grate. Figure 26
- Place Top Right Log (#4) in bottom log cutouts. Figure 27
- Rest Top Left Log (#5) in front and middle log cutouts. Figure 28
NOTE: Logs #1, #2 and #3 have ridges on the bottom which secure the logs to burner frame. After installing each log, check to be sure it is stable.
NOTE: Installation instructions are the same for 24″ and 30″ log sets. Illustrations shown are for the 24″ models. Some variations may exist between the images and the set included with this manual.
- Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed. In addition, periodically check the flames visually during operation.
CHECK THE PILOT FLAME
- The pilot flame must always be present when the heater is in operation. It should just touch the top of the thermocouple tip for natural. Refer to Figures 29 & 30 for correct pilot flame.
- If the pilot flame does not touch the thermocouple, then the main burner cannot function reliably. Refer to Figures 29 & 30 for incorrect shape of pilot flame.
MILLIVOLT CONTROL
Millivolt Control Pilot Flame Appearance
MANUAL & HI/LO CONTROL
FLAME APPEARANCE
- In normal operation at full rate after 15 minutes, the following flame appearances should be observed:
The left and right flames should be yellow and extend 1″ to 2″ above the log top surfaces. The yellow flames should not contact the logs.
OPERATING INSTRUCTIONS
- Avoid any drafts that alter burner flame patterns. Do not allow fans to blow directly into the fireplace. Do not place a blower inside the burn area of the firebox. Ceiling fans may create drafts that alter flame patterns. Sooting and improper burning will result.
During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or bonding agents. These chemicals are not harmful, but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance, possibly causing headaches or eye or lung irritation. This is a normal and temporary occurrence.
The initial break-in operation should last two to three hours with the burner at the highest setting. Provide maximum ventilation by opening windows or doors to allow odors to dissipate. Any odors remaining after this initial break-in will be slight and will disappear with continued use.
This appliance must not be used with glass doors in the closed position. This can lead to pilot outages and severe sooting outside the fireplace. 65D1009
FOR YOUR SAFETY, READ BEFORE LIGHTING
-
WARNING
If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. -
This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.
-
BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
- Do not attempt to light any appliance.
- Do not touch any electric switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
- Use only your hand to push in, or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it. Call a qualified service technician.
- Force or attempted repair may result in a fire or explosion.
- Do not use this appliance if any part of it has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.
OPERATING INSTRUCTIONS
MANUAL CONTROL LIGHTING INSTRUCTIONS
-
STOP! Read the safety information.
-
Make sure the manual shutoff valve is fully open.
-
This heater is equipped with an ignition device (piezo) which automatically lights the pilot.
-
Refer to Page 22, Figure 37 for the location of the piezo ignitor and control knob. Push in gas control knob slightly and turn control knob clockwise to the OFF position.
NOTE: Knob cannot be turned to OFF unless knob is pushed in slightly. Do not force. -
Wait 5 minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas STOP! Follow the instructions under “What to Do if You Smell Gas”, Page 20. If you do not smell gas, go to the next step.
-
From OFF position, push in gas control knob slightly and turn counterclock-wise to the IGN position. Figure 33. Push in and hold control knob for 5 seconds.
NOTE: If you are running the heater for the first time, it will be necessary to press in the control knob for 30 seconds to allow air to bleed out of the gas piping. -
With the control knob pushed in, push and release the piezo ignitor button to light the ODS pilot. The pilot is located on the left side of the heater, behind the middle log and in front of the back log. If piezo ignitor does not light the pilot, refer to “Match Lighting Instructions”, Page 23.
-
Hold the control knob in for an additional 10 seconds to prevent the ODS pilot from shutting off the gas while the thermocouple is warming up.
-
Release the control knob.
- If the knob does not pop out when released, stop and immediately call your service technician or gas supplier.
- If the ODS pilot will not stay lit after several tries, push and turn the gas control knob clockwise to OFF and wait 15 seconds. Repeat steps 6 through 9.
-
Push in control knob and turn counterclockwise to the HIGH setting. At this location the control knob will pop out when positioned correctly. The knob can now be positioned at any position between HIGH and LOW. Figures 34 and 35
WARNING
Wait 30 seconds before readjusting the heater when the control knob has
been turned down to a lower setting.
TO TURN OFF GAS TO HEATER
- Turn control knob clockwise to OFF position to completely shut off the heater.
- If applicable: Turn off all electric power to the heater.
MILLIVOLT CONTROL LIGHTING INSTRUCTIONS
- STOP! Read the safety information label.
- Make sure the manual shutoff valve is fully open.
- This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo ignitor does not light the pilot, refer to instructions for Match Lighting Instructions, Page 26.
- Turn gas control knob clockwise to the OFF position, set thermostat to lowest setting and turn ON/OFF switch to OFF position.
- Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow What to Do if You Smell Gas, Page 20. If you don’t smell gas, go to next step.
- From OFF position, turn the gas control knob counterclockwise to IGN position. Push in control knob for 5 seconds.
- With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.
- Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from shut-ting off the gas while the probe is warming up. Release the control knob.
- Turn gas control knob counterclockwise to the ON position.
- After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to ON position or adjust thermostat to desired setting.
- If the gas logs will not operate, follow the instructions To Turn Off Gas To Heater below and call your service technician or gas supplier.
TO TURN OFF GAS TO HEATER
- Turn control knob clockwise to OFF position to completely shut off the heater.
- If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.
- If applicable: Turn off all electric power to the heater.
OPERATING INSTRUCTIONS and MAINTENANCE
MATCH LIGHTING INSTRUCTIONS
- Remove any items necessary for easy access to the pilot (for example: logs, screens, etc.).
- Follow appropriate lighting instructions found previously. Instead of pushing and releasing the piezo button, light a match and hold the flame to the end of the pilot and ignite the pilot.
- After control knob has been released and pilot stays lit, reinstall any items that were removed for pilot access.
- Call a qualified service technician for repair or replacement of the piezo ignitor.
WARNING
- Turn off heater and allow to cool before cleaning.
- Disconnect electrical power (optional blower) before cleaning or servicing.
MAINTENANCE
Remove logs carefully by holding gently at each end. Gloves are recommended to
prevent skin irritation from ceramic fibers. If skin becomes irritated, wash
gently with soap and water. Refer to Log Placement, Pages 15-17 for correct
log placement.
PERIODIC CLEANING – Refer to the parts diagram for location of items discussed
below.
- Do not use cleaning fluid to clean logs or any part of heater.
- Brush logs with soft bristle brush or vacuum with brush attachment.
- Vacuum loose particles and dust from the front and rear burner, control and piezo covers and grate weldment.
- Inspect and clean burner air intake holes. Remove lint or particles with vacuum, brush, or pipe cleaners. Failure to keep air intake holes clean will result in sooting and poor combustion.
- External case should be dusted and wiped with a wet soapy cloth.
ANNUAL CLEANING/INSPECTION – Refer to the parts diagram for location of items discussed below.
- Inspect and clean burner air intake holes. Remove lint or particles with vacuum, brush or pipe cleaners. Failure to keep air intake holes clean will result in sooting and poor com-bustion.
- Inspect and clean all burner ports.
- Inspect ODS pilot for operation and accumulation of lint at air intake holes.
- Verify flame pattern and log placement for proper operation.
- Verify smooth and responsive ignition of main burner and rear burner.
TROUBLESHOOTING
- WARNING
- Turn off appliance and allow to cool before cleaning.
- Only a qualified service person should service and repair the heater.
NOTE: All troubleshooting items are listed in order of operation.
Problem | Possible Cause | Solution |
---|---|---|
When ignitor button is pressed, there is not spark at ODS/pilot. | Ignitor | |
electrode positioned wrong. | Replace ignitor. | |
Ignitor electrode is broken. | Replace ignitor. | |
Ignitor electrode not connected to ignitor cable. | Reconnect ignitor cable. | |
Ignitor cable pinched or wet. Keep ignitor cable dry. | Free ignitor cable if |
pinched by any metal or tubing.
Broken ignitor cable.| Replace ignitor cable.
Bad piezo ignitor.| Replace piezo ignitor.
Appliance produces un- wanted odors.| Appliance burning vapors from paint,
hair spray, glues, etc.| Ventilate room. Stop using odor causing products
while heater is running.
Gas leak.| Locate and correct leaks.
Initial burn off.| Ventilate room and turn unit on high until odor is gone.
Odor should be gone after 6 hours of continuous use.
Appliance shuts off during
use.
| Not enough fresh air is available for ODS/pilot to operate.| open window
and/or door for ventilation.
Low line pressure.| Contact local gas company.
ODS/pilot is partially clogged.| Clean ODS/pilot.
Defective thermopile.| Check wire connections. Check output should be 500 mV
across TH/TP and TP terminals with ON/OFF switches off.
Restrictions in incoming air flow.| Check for bottom riser on glass door,
sunken fireplace, excessive lava rock/ cinders densely packed against grate.
Gas odor even when control knob is in OFF position.| Gas leak.| Locate and
correct all leaks.
Control valve defective.| Replace control valve.
When ignitor button is pressed, there is spark at ODS/pilot, but no ignition.|
Gas supply turned off or manual shutoff valve closed.| Turn on gas supply or
open manual shutoff valve.
Control knob not in PILOT position.| Turn control knob to PILOT position.
Control knob not pressed in while inPILOT position.| Press in control knob
while in PILOT position.
Air in gas lines when installed.| Continue holding down control knob. Repeat
igniting operation until air is removed.
ODS/pilot is clogged.| Replace ODS/pilot assembly or get it services.
Gas regulator setting is not correct.| Check incoming pressure. Replace gas
regulator.
Problem| Possible Cause| Solution
---|---|---
ODS/pilot lights, but flame goes out when control knob is released.| 1.
Control knob not fully pressed in.| 1. Press in control knob fully.
2. Control knob not pressed in long enough.| 2. After ODS/pilot lights, keep
control knob pressed in for 30 seconds.
3. Manual shutoff valve not fully open.| 3. Fully open manual shutoff valve.
4. Thermocouple connection loose at control valve.| 4. Hand tighten
thermocouple connection until snug, then tighten 1/4 turn more.
5. Pilot flame not touching thermo- couple, which allows thermocouple to
cool, causing pilot flame to go out. This problem could be caused by either
low gas pressure, or a dirty or partially clogged ODS/pilot.| 5. Contact
local gas company.
6. Thermocouple damaged.| 6. Replace thermocouple.
7. Control valve damaged.| 7. Replace control valve.
Burner does not light after
ODS/pilot is lit.
| 1. Burner orifice is clogged.| 1. Clean burner or replace burner orifice.
2. Burner orifice diameter is too small.| 2. Replace burner orifice.
3. Inlet gas pressure is too low.| 3. Contact qualified service person.
Burner backfires during combustion.| 1. Manifold Pressure is too low.| 1.
Contact local gas company.
2. Burner orifice is clogged.| 2. Clean burner or replace burner orifice.
Slight smoke or odor during initial operation.| 1. Burner orifice is clogged
or dam- aged.| 1. Clean burner or replace burner orifice.
2. Burner is damaged.| 2. Replace burner.
3. Gas regulator is defective.| 3. Replace gas regulator.
Logs appear to smoke after initial operation.| 1. Vapors from paint or curing
process of logs.|
- Problem will stop after a few hours of operation. Run the heater with the damper open if you have one, or open a window for the first few hours.
- Log heater is intended to be smoke- less. Turn OFF heater and call qualified service person.
Heater produces a whis- tling noise when burner is lit.| 1. Turning control
knob to HIGH posi- tion when burner is cold.| 1. Turn control knob to LOW
position and let warm up for a minute.
2. Air in gas line.| 2. Operate burner until air is removed from line. Have
gas line checked by local gas company.
3. Dirty or partially clogged burner orifices.| 3. Clean burner or replace
burner orifice.
No gas to pilot.| 1. LP regulator shut down due to inlet pressure too high.|
- 1. Verify LP tank regulator is installed and set at 11” to 13” w.c.
- 2. Replace regulator on heater.
WARNING
If the gas quality is bad, your pilot may not stay lit, the burners may
produce soot and the heater may backfire when lit. If the gas quality or
pressure is low, contact your local gas supplier immediately.
REPLACEMENT PARTS
WARNING
Failure to position the parts in accordance with these diagrams or failure
to use only parts specifically approved with this appliance may result in
property damage or personal injury.
Ref.
| ****
Description
| ****
Qty.
| EYF18
Natural
| ****
Propane
| EYF24
Natural
| ****
Propane
---|---|---|---|---|---|---
1.| Burner| 1| 65D1053| 65D1054| 65D1055| 65D1056
2.| Piezo Ignitor| 1| 14D0503| 14D0503| 14D0503| 14D0503
Manual Control
3. Injector| 1| 58D0051| 20H3144| 70D0064| 57D0612
4. ODS Pilot Assy.| 1| 26D2529| 14D0476| 26D2529| 14D0476
5. Piezo Wire| 1| 00K0632| 00K0632| 00K0632| 00K0632
6. Knob Control| 1| 18D0603| 18D0603| 18D0603| 18D0603
7. Control Valve| 1| 30D0201| 30D0202| 30D0201| 30D0202
8. Regulator| 1| 24D0305| 24D0306| 24D0305| 24D0306
Regulator to Valve Tube| 1| 65D1004| 65D1004| 65D1004| 65D1004
Valve to Burner Tube| 1| 65D1005| 65D1005| 65D1006| 65D1006
Pilot Tube| 1| 49D0050| 49D0050| 49D0050| 49D0050
Pilot Regulator| 1| 14D0469| —| 14D0469| —
Millivolt Control
3. Injector| 1| 58D0051| 20H3144| 57D0209| 57D0612
4. ODS Pilot Assy.| 1| 14D0473| 14D0477| 14D0473| 14D0477
5. Piezo Wire| 1| 00K0632| 00K0632| 00K0632| 00K0632
7. Control Valve| 1| 14D0467| 14D0468| 14D0467| 14D0468
9. Knob Extension – ON/OFF| 1| 37D0010| 37D0010| 37D0010| 37D0010
10. Knob Extension – Hi/Lo| 1| 37D0011| 37D0011| 37D0011| 37D0011
11. On/Off Switch| 1| 32D0232| 32D0232| 32D0232| 32D0232
Valve to Burner Tube| 1| 65D1007| 65D1007| 65D1008| 65D1008
Pilot Tube| 1| 49D0050| 49D0050| 49D0050| 49D0050
Pilot Regulator| 1| 14D0469| —| 14D0469| —
Ref.| Description| Qty.| EYF18-R| EYF24-F|
EYF24-R| EYF30-R
---|---|---|---|---|---|---
1.| Main Log| 1| —| 65D0006K| —| —
2.| Front Log| 1| 65D1038K| 65D1030K| 65D1033K| 65D1501K
3.| Top Left Log| 1| —| 65D0008K| 65D1035K| 65D1035K
4.| Top Right Log| 1| —| 65D0009K| 65D1034K| 65D1034K
5.| Rear Log| 1| 65D1036K| —| 65D1031K| 65D1031K
6.| Middle Log| 1| 65D1037K| —| 65D1032K| 65D1500K
7.| Top Log| 1| 65D1039K| —| —| —
WARNING
Failure to position the parts in accordance with these diagrams or failure
to use only parts specifically approved with this appliance may result in
property damage or personal injury.
Massachusetts Residents Only – Please read and follow these special requirements
- NOTE REGARDING VENTED PRODUCTS
- This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.
- Any residence with a direct vent product must have a CO detector installed in the residence.
- Installation of the fireplace or vented gas log in the State of Massachusetts requires the damper to be permanently removed or welded in the fully open position.
- In addition, a naturally vented gas log may not be installed in a bedroom or bathroom in the State of Massachusetts.
- Flex line installation must not exceed 36 inches and must have a T shutoff valve.
- NOTE REGARDING VENT FREE PRODUCTS
- This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.
- In addition, vent free products may not be installed in a bedroom or bathroom regardless of size or type in the State of Massachusetts.
- Flex line installation must not exceed 36 inches and must have a T shutoff valve.
- CARBON MONOXIDE DETECTOR REQUIREMENTS
Revise 10.8.3 by adding the following additional requirements:
For all side wall horizontally vented gas fueled equipment installed in
every dwelling, building or structure used in whole or in part for residential
purposes, including those owned or operated by the Commonwealth and where the
side wall exhaust vent termination is less than seven (7) feet above finished
grade in the area of the venting, including but not limited to decks and
porches, the following requirements shall be satisfied:
- Installation of carbon monoxide detectors. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors
- In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
- In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.
- Approved Carbon Monoxide Detectors. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
- Signage. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.”
- Inspection. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.(b) Exemptions: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
- The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and
- Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.
- Manufacturer requirements — Gas Equipment Venting System Provided. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
- Detailed instructions for the installation of the venting system design or the venting system components; and
- A complete parts list for the venting system design or venting system.
- Manufacturer requirements — Gas Equipment Venting System Not Provided. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems,” the following requirements shall be satisfied by the manufacturer:
- The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and
- The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.
- A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design
Gas Logs Limited Warranty
What is covered and for How Long
MHSC will make available replacement parts for parts that are defective
according to the following terms.
Logs – A free replacement will be made available at our factory for any logs
if they fail due to deterioration within two (2) years of the verified
purchase.
Steel Burner – A free replacement will be made available at our factory for
the burner if it fails to deterioration within 10 years of the verified
purchase date.
All Other Parts – A free replacement will be made available at our factory for
any part that is defective within two (2) years of the verified purchase date.
What is Not Covered
- Removal and re-installation costs.
- Labor costs for replacement or repairs beyond our published warranty labor program.
- Transportation or shipping cost.
- The cost of a service call to diagnose trouble.
- Painted surfaces.
- Damage or defect caused by improper installation, accident, misuse, abuse or alteration.
- Replacement of rusted burner combustion chamber resulting from improper storage.
Limitations and Exclusions
- No one has authority to add to or vary this limited warranty, or to create for MHSC any other obligation or liability in connection with this heater/decorative gas appliance.
- Any implied warranty applicable to this heater/decorative gas appliance is limited in duration to the same period of time as this written warranty. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
- MHSC shall not be liable for incidental, consequential, special or contingent damages you might suffer as a result of its breach of written warranty or any implied warranty. Some states do not allow the exclusion or limitation of indicental or consequential damages, so the above limitation or exclusion may not apply to you.
- This warranty applies only to the original purchaser and may not be transferred.
- This warranty applies only to a gas heater/decorative gas appliance used as a residential appliance.
- If you cannot verify the purchase date of the heater/decorative gas appliance, the warranty period will begin on the date the heater/decorative gas appliance was manufactured. replacement or repair parts are warranted for the remaining period of the original part warranty. Warranty parts must be obtained through authorized dealers of the product and/or MHSC who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty.
This heater/decorative gas appliance must be installed by a qualified
installer, operated and maintained in accordance with all applicable codes and
the instructions furnished with it.
IF WARRANTY SERVICE IS NEEDED…
- Contact your supplier. Make sure you have your warranty, your sales receipt and the model/serial number of your MHSC product.
- DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF.
149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com