elero 28 120.0001 VarioTec Central Control Unit Instruction Manual
- June 3, 2024
- elero
Table of Contents
- Safety instructions
- Explanation of displays and buttons
- General information / Designated use
- Installation / Connection
- Explanation of functions
- Function menu/Explanation of functions
- Programming menu
- Programming
- Technical data / Cleaning / Troubleshooting
- General declaration of conformity
- Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
elero 28 120.0001 VarioTec Central Control Unit Instruction Manual
Safety instructions
Warning
Important safety instructions!
Always observe the following instructions.
Risk of injury by electric shock.
- All terminal connections to a 230 V network must be made by an authorised electrician.
- Before assembly, always disconnect the mains lead from the power supply.
- The provisions of the local public utilities and stipulations for wet and damp rooms in accordance with VDE 100 must be observed during system installation.
- For use in dry rooms only.
- Use unmodified elero original parts only.
- Keep persons away from the systems guide track.
- Keep children away from controls.
- Always comply with national stipulations.
- If the system is controlled by one or more devices, the system guide track must be visible during operation.
- Only cables with sufficient electric strength may be used to connect control cables (protective low voltages).
- The equipment contains small parts that could be swallowed.
Explanation of displays and buttons
Explanation of displays
Buttons under the cover
Encoding switch (located on back of device)
-
Upper position → Alarm signal function OFF.
Lower position → Alarm signal function ON. -
Upper position → Group controller
Lower position → Driver controller -
Upper position → Venetian blind mode
Lower position → Roller shutter/ awning mode
General information / Designated use
General information
The Vario Tec device operates your roller shutters/sun protection systems on the basis of manual or external control commands.
The Vario Tec device can be operated manually at all times.
The Vario Tec is characterized by its user-friendly operation.
Designated use
The Vario Tec may be used to operate roller shutters/sun protection systems
only.
This device may only be used in connection with equipment from other
manufacturers following consultation with your local retailer.
Installation / Connection
Installation
Note: The encoding switch located on the back of the VarioTec device can be used to select group or drive control.
Connection as a drive controller
For details on suitable control systems, please refer to the control product
catalogue.
Risk of injury by electric shock!
Warning
- **** Terminal connections must be carried out by an authorised electrician!
- If more than one drive is operated using the Vario Tec, the drives must be decoupled by relay controls.
- The switched current of the device must be observed at all times!
- Remove the protective caps.
- Connect.
Note:
Always use a shielded control wire . . . 0.8 mm or JY-ST telephone line . . .
0.6 mm.
- Replace the protective caps on the power supply unit.
- Secure the power supply unit in the box.
- Insert the operating device into the frame and plug it into the power supply unit.
Connection as a group controller
You can find the structure of a controller on elero.com in the download area
unter „Installation instructions and circuit diagrams“.
Risk of injury by electric shock!
Warning
- Terminal connections must be carried out by an authorised electrician!
-
Remove the protective caps.
-
Connect
Note:
Always use a shielded control wire . . . 0.8 mm or JY-ST telephone line . . . 0.6 mm. -
Replace the protective caps on the power supply unit.
-
Secure the power supply unit in the box.
-
Insert the operating device into the frame and plug it into the power supply unit.
Explanation of functions
Factory settings
Encoding switch factory setting
1 | Lower position | Alarm signal function ON. |
---|---|---|
2 | Lower position | Driver controller. |
3 | Lower position | Roller shutter/awning mode. |
Manual/Automatic sliding switch
In the “MANUAL “ mode, only manual control commands and alarm signals are
executed (e.g.: by pressing UP, STOP, DOWN buttons and alarm button).
When the sliding switch is set to “AUTO”, automatic control commands are
carried out (e.g. control signals via group control inputs.)
Alarm signal control light
An alarm signal is a continuous switching signal at the group or individual
control inputs which lasts for more than 5 seconds.
If the alarm signal control light is illuminated, this indicates an alarm
signal. The encoding switch 1 can be used to switch the alarm signal function
on or off.
Reset button:
Press the Reset button (with a ballpoint pen or similar object) to delete the
intermediate position and the ventilation/reverse position.
POS ∇:
The Pos ∇ button can be used to programmed an intermediate position.
POS ∆:
The Pos ∆ button can be used to program a ventilation/reverse position.
Group control:
Group control refers to the simultaneous operation of several drives.
Intermediate position:
The intermediate position lies between the upper and lower limits of the
roller shutters/sun protection system and can be freely selected. The roller
shutters/sun protection system can be moved into this position from the upper
end limit after programming. To do so, press the DOWN button twice in
quick succession.
When the system is in venetian blind mode, it is also possible to programme a
reverse position. In this case, this command will be automatically executed
following the intermediate position command.
Ventilation/reverse:
The ventilation/reverse position lies between the upper and lower limits of
the roller shutters/sun protection system and can be freely selected. Your
roller shutters can be moved into this position from the lower end limit until
the ventilation slats are open.
In venetian blind mode, the blind slats are turned.
To do so, press the UP button twice in quick succession.
Function menu/Explanation of functions
Drive controller:
If the VarioTec device is being used as a drive controller, the drive is
directly connected to the VarioTec device, in which case external signals are
converted into control commands. Encoding switch 2 must be set to the lower
position.
Group controller:
If the VarioTec device is being used as a group controller, additional group
and drive control devices can be connected. Encoding switch 2 must be set to
the upper position.
Selecting roller shutter/awning or venetian blind:
Encoding switch 3 is used to select roller shutter/awning mode (lower
position) or venetian blind mode.
In venetian blind mode, the blind moves in non-maintained command mode to
ensure that the slats are positioned accurately.
Press and hold any control button for more than 1 second to operate the
venetian blind in maintained command mode.
Functions
Manual operation functions
- UP, STOP, DOWN
- Adjustment to intermediate position
- Adjustment to ventilation/reverse position
- Alarm signals
Automatic operation functions
In automatic mode, both manual and external control commands are executed:
- External automatic control commands
- UP, STOP, DOWN
- Adjustment to intermediate position
- Adjustment to ventilation/reverse position
- Alarm signals
Programming menu
Programming
Programming the intermediate position
Prerequisite: The shutter/curtain/blind is in the upper end limit position.
-
Press and hold the Pos ∇ programming button.
-
Keeping this button pressed, then press the DOWN button until the desired intermediate position has been reached.
Use the UP or DOWN button to make any necessary adjustments. -
Release the Pos ∇ the programming button. The intermediate position is now stored.
The control light will flash 3 times briefly.
Programming the ventilation/reverse position
Prerequisite: The shutter/curtain/blind is in the lower end limit position.
-
Press and hold the Pos ∆ programming button.
-
Keeping this button pressed, then press the UP button until the desired ventilation/reverse position has been reached.
Use the UP or DOWN button to make any necessary adjustments. -
Release the Pos ∆ programming button. The ventilation/ reverse position is now stored.
The control light will flash 3 times briefly.
Programming
Adjustment to intermediate position
The shutter/curtain/blind can only be moved into the intermediate position
from the upper end limit position.
- Press the DOWN button twice in quick succession.
The shutter/curtain/blind is adjusted into the stored
intermediate position.
Adjustment to ventilation position (roller shutters)
Roller shutters can only be moved into the ventilation position from the lower
end limit position.
- Press the UP button twice in quick succession. The shutters are adjusted into the stored ventilation position.
Adjustment to reverse position (venetian blinds)
The venetian blind slats must be closed before the blind can be adjusted into
the reverse position.
- Press UP button twice in quick succession.
The venetian blind is adjusted into the stored reverse position.
When the blind reaches the stored intermediate position the blind slats are turned automatically (provided a reverse position has been pre-programmed).
Deleting intermediate position
- Press and hold the Pos ∇ programming button for more than 5 seconds. The intermediate position is now deleted.
The control light will flash 3 times briefly.
Deleting ventilation/reverse position
Press and hold the Pos ∆ programming button for more than 5 seconds. The
ventilation/reverse position is now deleted.
The control light will flash 3 times briefly.
Technical data / Cleaning / Troubleshooting
Technical data
Nominal voltage | 230-240 V AC / 50-60 Hz |
---|---|
Switched current | 5 A /250 V AC for cos j |
System of protection | IP 20 |
Protection class
The protection class II is guaranteed installation.
| II
only after a correct
Permissible ambient temperature| 0 to +55 °C
Type of installation| Concealed: 0 58 mm wall mounted
Exposed: in appropriate exposed casing
Cleaning
Clean the device with a damp cloth only. Do not use a cleansing agent as doing so may damage the plastic.
Troubleshooting
Problem | Cause | Remedy |
---|---|---|
Drive is not functioning. | Faulty connection. | Check connection. |
Drive moves in the wrong direction. | Faulty connection. | Exchange A and V |
wires in the power supply unit.
Vario Tec does not carry out external control commands.|
- Device is set to “MANUAL r‘; ” mode.
- Alarm signal is active.2.
|
- Set the device to “AUTO” mode.
- Wait until alarm signal disappears or rectify problem causing signal.
General declaration of conformity
The company elero GmbH hereby declares that the VarioTec device complies with
the basic requirements and other relevant regulations of the EC Directive
2014/35/EU.
elero GmbH hereby declares that the radio system type VarioTec is in
compliance with directive 2014/53/EU. The complete text of the EU declaration
of conformity is available at the following address:
www.elero.com/downloads/
Support
elero GmbH
Antriebstechnik
Maybachstr. 30
73278 Schlierbach
info@elero.de
www.elero.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>