- Please follow the local building code and electrical code to install the device.
- Suggest installing the device with a bottom line 45~55 inches (1.2~1.4 meters) above the ground lever.
- Please avoid dropping or vigorous vibrating of the device.
- Please keep the device away from a strong electromagnetic field or explosive atmosphere.
- Do not open or install the device in a damp environment. Avoid using the device in a very low or high-temperature environment.
- Recommend to seal the frame or wall gap with silicone or another sealant after installation to avoid inside water leaking.
- Remove the electrostatic adsorption protective plastic film after all installations/configurations to avoid lens cover contamination or scratch.
- Please refer to the Grnadstream website for more updated Online Documents like:
QIG:
www.grandstream.com/sites/default/files/
Resources/GDS3705_QIG.pdf
www.grandstream.com/sites/default/files/
Resources/GDS3710_QIG.pdf
User Manual:
www.grandstream.com/sites/default/files/
Resources/GDS3705_UserManual.pdf
www.grandstream.com/sites/default/files/
Resources/GDS3710_UserManual.pdf
FAQ:
www.grandstream.com/our-products
The warranty not apply to defects and failures as a result of improper
installation.
The manufacturer is neither liable for damages caused by theft within an area
that is accessible after the attached electric lock is switched. The product
is not designed as a burglar protection device except when used in combination
with a standard lock.
If the proper mounting instructions not met, water might get in and destroy
the electronics as the internal circuits are under continuous operation.
The manufacturer’s warranty shall be void for products damaged in this way.
This guide applies to both GDS3705 and GDS3710, with GDS3710 in the
illustration.
PACKAGE CONTENTS
Solid Wall Installation
Please follow below steps to install the device into a solid wall.
Step 1 : Use provided Drill Template to mark boundary then drill holes
for the 6 mounting screws and the circular hole for wiring. (drilling or dig
tools not provided) Then dig a rectangle hole for the box with a depth around
38~43 mm (or 1.50~1.69 inch), refer to mark in the template (rotating it to
measure if necessary).
Step 2 : Mount the Installation Bracket into the Plastic Box using supplied Screws( 2 ).
Step 3 : Use provided Anchor/Screw( 1 ) to mount the Plastic Box inside the hole just digged.
Step 4 : Remove the frame back cover (designed for Surface/ OnWall Installation).
Step 5 : Follow GDS37XX QIG and User Manual to connect wires to the PoE switch or PoE Injector. Connect the Electrical Lock wiring according to its document.
Step 6 : Align the GDS37XX with the bracket, press, and push down the GDS37XX into place.
Step 7 : Install the Cover Plate and fix it using the Hex Key with the Anti-Tamper Screws( 5 ) provided.
Stud Installation
Please follow below steps to install the device at the stud of a new building
open wall, or a finished wall.
Step 1 : For the finished wall, use provided Drill Template to mark a
boundary and dig a rectangle hole into the wall. For open the wall, skip and
go to the next step.
Step 2 : Install the Metal Frame with a short edge to the stud using the set of Anchor/Screw( 1 ) provided.
Step 3 : Mount the Installation Bracket into the Plastic Box using supplied Screws( 2 ).
Step 4 : Use provided Screws and Nuts( 3 )( 4 ) to install the Plastic Box on the long edge of the Metal Frame. Choose either set of Nuts( 4 ) with convenience.
Step 5 : Remove the frame back cover (designed for Surface/ OnWall Installation).
Step 6 : Follow GDS37XX QIG and User Manual to connect wires to the PoE switch or PoE Injector. Connect the Electrical Lock wiring according to its document.
Step 7 : Align the GDS37XX with the bracket, press, and push down the
GDS37XX into place.
Step 8 : Install the Cover Plate and fix it using the Hex Key with the
Anti-Tamper Screws( 5 ) provided.
Drywall (Hollow Wall) Installation
Please follow below steps to install the device on drywall or hollow wall. The
thickness of the wall where the clamps can handle is 6.2 ~ 24 mm (or 0.24 ~
0.94 inch )
Step 1 : Use provided Drill Template to mark the boundary then cut the
opening on the drywall. Do NOT overcut. (wall cutting tools not provided)
Step 2 : Mount the Installation Bracket into the Plastic Box using supplied Screws( 2 ).
Step 3 : Insert the Plastic Box into the cutted hole properly.
Step 4 : Tighten the four clamps alternately in diagonal to mount the Plastic Box on the wall. Please do NOT over-tighten to avoid damaging the wall or clamp.
Step 5 : Remove the frame back cover (designed for Surface/ OnWall Installation).
Step 6 : Follow GDS37XX QIG and User Manual to connect wires to the PoE switch or PoE Injector. Connect the Electrical Lock wiring according to its document.
Step 7 : Align the GDS37XX with the bracket, press, and push down the GDS37XX into place.
Step 8 : Install the Cover Plate and fix it using the Hex Key with the Anti-Tamper Screws( 5 ) provided.
Grandstream Networks, Inc.
126 Brookline Ave, 3rd Floor
Boston, MA 02215. USA
Tel : +1 (617) 566 – 9300
Fax: +1 (617) 249 – 1987
www.grandstream.com
For Warranty and RMA information, please visit
www.grandstream.com
Documents / Resources
|
GRANDSTREAM GDS3710-3705 In-Wall Mounting
Kit
[pdf] User Guide
GDS3710-3705, In-Wall Mounting Kit
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>