FORTINET FortiWiFi 50G DSL Network Security Gateway User Guide
- July 29, 2024
- FORTINET
Table of Contents
Quick Start Guide
FortiWiFi 50G DSL
FWF-50G-DSL
The Essentials
FortiCare
Register your device to activate FortiCare Support at
https://support.fortinet.com
WiFi
- Connect to the default fortinet wireless network
- Open a browser to https://192.168.1.99
LAN
- Connect Port 1 to an Ethernet port or USB-RJ45 adapter on your computer using the provided Ethernet cable
- Open a browser to https://192.168.1.99
CLI
- Connect a console cable (not included) to the Console Port
- Open a Terminal app using 9600-8-N-1
Default Logins
| https://192.168.1.99
Username: admin
Password: leave blank| | SSID: fortinet
Password: fortinet
---|---|---|---
Fortinet Documents Library
For getting started documentation, admin guides, up-to-date hardware manuals
and reference resources, visit https://docs.fortinet.com/
FortiGate Cloud
Experience simplified cloud provisioning, security analytics, remote access,
hosted log retention and reporting at https://fortigate.forticloud.com
FortiExplorer Go
Rapidly provision, deploy and manage your Fortinet Security Fabric Platform,
free on iOS and Android: https://docs.fortinet.com/product/fortiexplorer-go/
Package Contents
FortiWiFi 50G DSL
FWF-50G-DSL
Setup
FortiExplorer Go
FortiGate Cloud
Flow Control: None
Login to https://fortigate.forticloud.com using your Fortinet Credentials,
then click Add FortiGate and enter the Cloudkey
Front FWF-50G-DSL
-
BLE / RESET Press to enable BLE; press and hold for system reset
Blue: BLE connected
Flashing Blue: BLE in discovery
Off: BLE not connected -
Signed Firmware BIOS Security Level
Controlled by Signed Firmware Switch, see Admin Guide at https://docs.fortinet.com
Green: Security Level 2 (default)
Amber: Security Level 1
Red: Security Level 0 -
PWR
Green: Power detected
Off: Power not detected
LINK/ACT
Green: DSL connected
Flashing Green: DSL activity
Off: DSL not connected
STATUS
Green: Operating normally
Flashing Green: Booting up
Off: Device is off
xDSL
Green: VDSL connection
Amber: ADSL connection
Off: No DSL connection
HA
Green: HA enabled (normal)
Amber: HA enabled (failover)
Off: HA disabled
WIFI
Green: WiFiis on
Flashing Green: WiFi activity
Off: WiFi is off -
Ports
LINK/ACT
Green: Connected
Flashing Green: Data activity
Off: Not connected
SPEED
Green: 1 Gbps
Amber: 100 Mbps
Off: 10 Mbps or not connected
Rear FWF-50G-DSL
- Power Input 12V DC, 100-240V AC, 50/60Hz adapter
- USB 3.0 Port (USB-A)
- CONSOLE Port (RJ-45) CLI management
- Signed Firmware Switch
- DSLPort (RU-11)
- Ports (5x RJ-45) WAN, A – FortiLink, 3, 2,1
- Antenna Connector (3x SMA)
Cautions and Warnings
Environmental specifications
Ambient operating temperature: O°C to 40°C
Refer to specific Product Model Data Sheet for Environmental Specifications
(Operating Temperature, Storage Temperature, Humidity, and Altitude)
Safety
Battery – Risk of explosion if the battery is replaced by an incorrect
type. Do not dispose of batteries in a fire. They may explode. Dispose of used
batteries according to your local regulations. IMPORTANT: Switzerland: Annex
4.10 of SR814.013 applies to batteries.
This product is intended to be supplied by a Listed pluggable A via Class |
external power supply adapter by means of a power cord connected to a socket-
outlet with earthing connection.
Grounding — To prevent damage to your equipment, connections that enter
from outside the building should pass through a lightning / surge protector,
and be properly grounded. Use an electrostatic discharge workstation (ESD)
and/or wear an anti-static wrist strap while you work. In addition to the
grounding terminal of the plug, on the back panel, there is another, separate
terminal for earthing.
This product has a separate protective earthing terminal provided on the back
of the product in addition to the grounding terminal of the attachment plug.
This separate protective earthing terminal must be permanently connected to
earth with a green with yellow stripe conductor minimum size #
22AWG and the connection is to be installed by a qualified service personnel.
Warning: Equipment intended for installation in Restricted Access Location.
Disconnect ES2 (TNV) circuit connector before removing cover.
IMPORTANT SAFETY INSTRUCTIONS – When using your telephone equipment, basic
safety precautions should always be followed to reduce the risk of fire,
electric shock and injury to persons, including the following:
- Do not use this product near water for example, near a bathtub, washbowl, kitchen sink or laundry tub, in a wet basement or near a swimming pool.
- Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning.
- Do not use the telephone to report a gas leak in the vicinity of the leak.
- Use only the power cord and batteries indicated in this manual. Do not dispose of batteries in a fire. They may explode. Check with local codes for possible special disposal instructions.
SAVE THESE INSTRUCTIONS
CAUTION: To reduce the risk of fire, use only No. 26 AWG or larger
(e.g., 24 AWG) UL Listed or CSA Certified Telecommunication Line Cord
Regulatory Notices
Federal Communication Commission (FCC) – USA
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received; including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Ciass B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
WARNING: Any changes or modifications to this unit not expressly approved
by the party responsible for compliance could void the user’s authority to
operate the equipment
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and Operated with
minimum distance 20cm between the radiator and your body. This transmitter
must not be co-located or operating in conjunction with any other antenna or
transmitter.
This device meets all the other requirements specified in Part 15E, Section
15.407 of the FCC Rules.
This equipment complies with ANSI TIAVEIA/968-B and Part 68 of the FCC rules
and the requirements adopted by the ACTA. On the base of this equipment is a
label that contains, among other information, a product identifier in the
format US: AAAEGHH#NOOX. If requested, this number must be provided to the
telephone company.
This equipment uses the following USOC jacks: RJ11.
A plug and jack used to connect this equipment to the premises wiring and
telephone network must comply with the applicable FCC Part 68 rules and
requirements adopted by the ACTA. A compliant telephone cord and modular plug
is provided with this product. It is designed to be connected to a compatible
modular jack that is also compliant. See installation instructions for
details.
The REN is used to determine the number of devices that may be connected to a
telephone line. Excessive RENs on a telephone line may result in the devices
not ringing in response to an incoming call. In most but not all areas, the
sum of RENs should not exceed five (5.0). To be certain of the number of
devices that may be connected to a line, as determined by the total REN,
contact the local telephone company. The REN for this product is separately
shown on the label and also part of the product identifier that has the format
US: AAAEQ##TOOX. The digits represented by ## are the REN without a decimal
point (e.g., 03 is a REN of 0.3).
If you experience trouble with this equipment, for repair or warranty
information, please refer to Fortinet’’s End-User License Agreement which set
forth the terms and limitation of Fortinet’s product warranty and contact the
following address and phone number for additional information.
Fortinet, Inc.
899 Kifer Road, Sunnyvale, CA 94086 USA
1-866-393-9960 (US and Canada)
1-613-725-2466 (International
http://www.fortinet.com
It is recommended that the customer install an AC surge arrester in the AC
outlet to which this device is connected. This is to avoid damaging the
equipment caused by local lightning strikes and other electrical surges.
This equipment may not be used on coin service provided by the telephone
company. Connection to party line service is subject to state tariffs.
Innovation, Science and Economic Development (ISED) – Canada
This Ciass B digital apparatus complies with Canadian ICES-003.
This device contains licence-exempt transmitter(s/receiver(s) that compty with
Innovation, Science and Economic Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
For product available in the USA/Canada market, only channel 1~11 can be
operated. Selection of other channets is not possible.
This equipment complies with ISED radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
The maximum antenna gain permitted for devices in the band 5725-5850 MHz shall
be such that the equipment still complies with the e.i.r.p. limits Specified
for point-to-point and non-point-to-point operation as appropriate.
The maximum antenna gain permitted for devices in the bands 5250-5350 MHz and
5470-5725 MHz shall comply with the e.i.r.p. limit; and
The worst-case tilt angle(s) necessary to remain compliant with the e.i.rp.
elevation mask requirement set forth in Section 6.2.2(3) shall be clearly
indicated.
Caution: The device for the band 5150-5250 MHz is only for indoor usage to
reduce potential for harmful interference to co-channel mobile satellite
systems.
Caution: The maximum antenna gain permitted for devices in the bands 5250-5350
MHz and 5470-5725 MHz shall comply with the e.i.rp. limit; and the maximum
antenna gain permitted for devices in the band 5725-5825 MHz shall comply with
the e.i.p. limits specified for point-to-point and non point-to-point
operation as appropriate.
This radio transmitter (IC: 7280B-3901M12 / Model: FWF-50G-DSL) has been
approved by ISED to operate with the antenna types listed below with the
maximum permissible gain and required antenna impedance for each antenna type
indicated. Antenna types not included in this list, having a gain greater than
the maximum gain indicated for that type, are strictly prohibited for use with
this device.
This device and it’s antennas{s) must not be co-located or operating in
conjunction with any other antenna or transmitter except in accordance with IC
multi-transmitter product procedures.
Antenna No.| Manufacturer| Model| Antenna Type|
Connector| Antenna Peak Gain
---|---|---|---|---|---
1| Speed| F-OQ-FS-6156-001-00| Dipole| SMA| 0.31 dBi for 2.4GHz(WLAN)
2.54 dBi for 5GHz
2| Speed| F-OQ-FS-6156-001-00| Dipole| SMA| 0.31 dBi for 2.4GHz(WLAN)
2.54 dBi for 5GHz
3| Speed| F-OQ-FS-6156-001 -00| Dipole| SMA| 0.31 dBi for 2.4GHz(WLAN)
2.54 dBi for 5GHz
4| Joymax| IHF-2120MPX9-W018| Monopole| iPex MHF1| 1.53 dBi for 2.4GHz(BLE)
IMPORTANT: The device must be professionally installed and must use the
supplied antenna.
Professional Installation Instruction
-
Installation personnel
This product is designed for specific application and needs to be installed by qualified personnel who has RF and related rule knowledge. The general user shall not attempt to install or change the settings. -
Installation location
The product shall be installed at a location where the radiating antenna can be kept 20cm from nearby person in normal operation condition to meet Regulatory RF exposure requirement. The installation applies to indoor location. -
External antenna(s)
Use only the antenna(s) that have been approved by the manufacturer. The non- approved antenna(s) may produce unwanted spurious or exces- sive RF transmitting power that may lead to the violation of FCC/ISED limit and is prohibited. -
Warning
Please carefully select the installation position and ensure that the final output power does not exceed the limit set forth in relevant rules. The violation of the rule could lead to serious federal penalty.
NOTICE: This product meets the applicable Industry Canada terminal
technical specifications. This is confirmed by the registration number. The
abbreviation, IC, before the registration number signifies that registration
was performed based on a Declaration of Conformity indicating that Industry
Canada technical specifications were met. It does not guarantee the equipment
will operate to the user’s satisfaction.
NOTICE: The Ringer Equivalence Number (REN) for this terminal equipment
is 0.1. The REN assigned to each terminal equipment provides an indication of
the maximum number of terminals allowed to be connected to a telephone
interface. The termination on an interface may consist of any combination of
devices subject only to the requirement that the sum of the Ringer Equivalence
Numbers of all the devices does not exceed five.
European Conformity (CE) – EU
This is a Class B product. In a domestic environment, this product may
cause radio interference, in which case the user may be required to take
adequate measures.
This equipment should be installed and operated with minimum distance 20cm
between the radiator and your body.
Simplified EU Declaration of Conformity
This declaration is only valid for Fortinet products (including
combinations of software, firmware and hardware) provided by Fortinet or
Fortinet’s authorized partners to the end-customer directly for use within the
EU or countries that have implemented the EU Directives and/or spectrum
regulation. Any Fortinet products not obtained directly from Fortinet or
Fortinet’s authorized partners may not comply with EU Directives and Fortinet
makes no assurances for such products.
This product is in compliance with Directive 2014/53/EU.
Note: The full Declaration of Conformity for this product is available in
the link below: https://site.fortinet.com/ProductRegulatory/EU
The device is restricted to indoor use only when operating in the 5150 to
53850 MHz frequency range in the following countries:
| AT| BE| BG| HR| CY| CZ| DK
---|---|---|---|---|---|---|---
EE| Fl| FR| DE| EL| HU| IE
IT| LV| LT| LU| MT| NL| PL
PT| RO| SK| SI| ES| SE| UK (NI)
Compliance with 2014/53/EU Radio Equipment Directive (RED)
In accordance with Article 10.8(a) and 10.8(b) of the RED, the following table
provides information on the frequency bands used and the maximum RF transmit
power of the product for sale in the EU:
STANDARD | FREQUENCY RANGE | TRANSMIT POWER |
---|---|---|
Bluetooth | 2402-2480MHz | Less than 10dBm (EIRP) |
WLAN | 2412-2472MHz | Less than 20dBm (EIRP) |
5180-5240MHz | Less than 23dBm (EIRP) | |
5260-5320MHz | Less than 23dBm (EIRP) * | |
5500-5700MHz | Less than 30dBm (EIRP) * | |
5745-5825MHz | Less than 14dBm (EIRP) |
Note: * Only with DFS bands certification
UK Conformity Assessed (UKCA) – United Kingdom
The product transmits within the frequency ranges and less than or equal to
the power listed below:
STANDARD | FREQUENCY RANGE | TRANSMIT POWER |
---|---|---|
Bluetooth | 2402-2480MHz | Less than 10dBm (EIRP) |
WLAN | 2412-2472MHz | Less than 20dBm (EIRP) |
5180-5240MHz | Less than 23dBm (EIRP) | |
5260-5320MHz | Less than 23dBm (EIRP) * | |
5500-5700MHz | Less than 30dBm (EIRP) * | |
5745-5825MHz | Less than 14dBm (EIRP) |
Note: * Only with DFS bands certification
This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.
This product is in compliance with Statutory Instrument 1206 Radio Equipment
Regulations 2017
The full Declaration of Conformity for this product is available in the link
below:
https://site.fortinet.com/ProductRequlatory/UK
The device is restricted to indoor use only when operating in the 5150 to 5350
MHz frequency range in the following countries:
| UK
---|---
April 30, 2024
Copyright © 2024 Fortinet, Inc. All rights reserved. Fortinet®, FortiGate®,
FortiCare® and FortiGuard®, and certain other marks are registered trademarks
of Fortinet, Inc., and other Fortinet names herein may also be registered
and/or common law trademarks of Fortinet. All other product or company names
may be trademarks of their respective owners. Performance and other metrics
contained herein were attained in internal lab tests under ideal conditions,
and actual performance and other results may vary. Network variables,
different network environments and other conditions may affect performance
results. Nothing herein represents any binding commitment by Fortinet, and
Fortinet disclaims all warranties, whether express or implied, except to the
extent Fortinet enters a binding written contract, signed by Fortinet’s Chief
Legal Officer, with a purchaser that expressly warrants that the identified
product will perform according to certain expressly-identified performance
metrics and, in such event, only the specific performance metrics expressly
identified in such binding written contract shall be binding on Fortinet. For
absolute clarity, any such warranty will be limited to performance in the same
ideal conditions as in Fortinet’s internal lab tests. Fortinet disclaims in
full any covenants, representations, and guarantees pursuant hereto, whether
express or implied. Fortinet reserves the right to change, modify, transfer,
or otherwise revise this publication without notice, and the most current
version of the publication shall be applicable.
For Product License Agreement / EULA and Warranty Terms, visit
https://www.fortinet.com/content/dam/fortinet/assets/leqal/EULA.pdf
FWF-50G-DSL-QSG-20240430
FWF-50G-DSL-QSG-20240430.indd 16
4/30/2024 2:34:22 PM
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>