FORTINET 80F Series Forti Gate WiFi Data Sheet User Guide
- June 2, 2024
- FORTINET
Table of Contents
FORTINET 80F Series Forti Gate WiFi Data Sheet
Before you begin
Register your device to access FortiGuard updates, cloud management, firmware
upgrades, technical support and warranty coverage.
https://support.fortinet.com
FortiExplorer App
Rapidly provision, deploy, and monitor Security Fabric components including
FortiGate and FortiWiFi devices from your mobile. Download now for free.
Scan the QR Code or visit
https://links.fortinet.com/fortiexplorer/downloads
The Essentials
Default Logins
https://192.168.1.99
Username: admin
Password: leave blank
Admin Guide
For a detailed Getting Started guide, setup and configuration information,
refer to the Admin Guide at https://docs.fortinet.com/
Customer Service
For contracts, licensing, product registration and account management, contact
FortiCare Support at https://www.fortinet.com/support/contact
Self-service Resources
Access our knowledge base, forums, videos and technical experts at
https://www.fortinet.com/support/support-services/forticare-support
Thank you for choosing Fortinet
Package Contents
FortiGate 80F Series
FG-80F, FG-81F, FG-80F-BYPASS, FG-80F-POE, FG-81F-POE, FG-80F-DSL
Quick Setup
Unpack the box, power the device, plug the Ethernet cable from a WAN port to
the Internet and launch FortiExplorer using one of the following:
BLE Auto Detection
- Enable Bluetooth on your Fortinet device and your mobile, then place them near each other
- FortiExplorer will automatically detect your device
- Follow the on-screen instructions to complete your setup
USB Connectivity
- Connect your mobile to your Fortinet device with a USB cable
- If the device is not detected, navigate to My Fabric, tap Add and follow the FortiExplorer’s on-screen instructions
FortiGate Cloud Key Registration
- Navigate to My Fabric, then tap Add
- Scan the FortiGate Cloud Key located on your Fortinet device
- Follow the on-screen instructions to complete your setup
Note: FortiExplorer can manage FortiGates without WiFi capabilities once they have been provisioned to allow HTTP/S admin access
Additional Setup Options
Set up your Fortinet device locally or connect using forticloud.com
GUI
Note: For static IP configuration, use 192.168.1.1 with a subnet mask 255.255.255.0
CLI
Note: For a detailed CLI guide, visit docs.fortinet.com
FortiGate Cloud Key (Connect a WAN port to the Internet)
- Go to forticloud.com and log in with your FortiCloud Credentials or Register
- Follow the on-screen instructions, then click Add FortiGate
- Enter the FortiGate Cloud Key located on the sticker of your device
Front – FG 80F Series
- Grounding Screw additional protective earth connection, reserved for applications where a permanent local connection of protective earth is required
- Console (RJ-45) CLI management computer interface USB (USB A) USB 3.0 server port|
- SFP Shared Ports 1 & 2 (SFP) 1 Gbps SFP interface
- WAN Shared Ports 1 & 2 (RJ45) 1 Gbps Ethernet interface
- BYPASS Port Pair (RJ45) 1 Gbps Ethernet interface (FG 80F-Bypass model only. WAN1 & Porti are the default configuration)
- Ports 1 to 6 (RJ-45) 1 Gbps Ethernet interface
- FortiLink Ports A & B (RJ-45) 1 Gbps Ethernet interface
- Power Input 12V DC 3A, 100-240V AC 50/60Hz (optional redundant power adapter and cable available for purchase)
Front – FG 80F-POE Series
Back – FG 80F-POE Series
- Grounding Screw additional protective earth connection, reserved for applications
- where a permanent local connection of protective earth is required Console (RJ-45)
- CLI management computer interface USB (USB A) USB 3.0 server port
- SFP Shared Ports 1 & 2 (SFP) 1 Gbps SFP interface
- WAN Shared Ports 1 & 2 (RJ45) 1 Gbps Ethernet interface
- Ports 1 to 6 (RJ-45) 1 Gbps Ethernet interface
- FortiLink Ports A & B (RJ-45) 1 Gbps Ethernet interface
- Power Input 54V DC 2.78A, 100-240V AC 50/60Hz (optional redundant power adapter and cable available for purchase)
Front – FG 80F-DSL Series
Back – FG 80F-DSL Series
- Grounding Screw additional protective earth connection, reserved for applications where a permanent local connection of protective earth is required
- Console (RJ-45) CLI management computer interface USB (USB A) USB 3.0 server port
- SFP Shared Ports 1 and 2 (SFP) 1 Gbps SFP interface
- WAN Shared Ports 1 and 2 (RJ45) 1000/100/10 Mbps Ethernet interface
- Ports 1 to 6 (RJ-45) 1000/100/10 Mbps Ethernet interface
- FortiLink Ports A and B (RJ-45) 1000/100/10 Mbps Ethernet interface
- Power Input 12V DC 3A, 100-240V AC 50/60Hz (optional redundant power adapter and cable available for purchase)
Environmental specifications
- Ambient operating temperature: 0°C to 40°C
- Refer to specific Product Model Data Sheet for Environmental Specifications
- (Operating Temperature, Storage Temperature, Humidity, and Altitude)
Safety
Battery – Risk of explosion if the battery is replaced by an incorrect type.
Do not dispose of batteries in a fire. They may explode. Dispose of used
batteries according to your local regulations. IMPORTANT: Switzerland: Annex
4.10 of SR814.013 applies to batteries.
CAUTION
- There is a danger of explosion if a battery is incorrectly replaced. Replace only with the same or equivalent type.
- Dispose batteries of according to the manufacturer’s instructions.
- Disposing of a battery in a fire, or a hot oven, mechanically crushing, or cutting it can result in an explosion.
- Leaving a battery in an extremely hot environment can result in leakage of flammable liquid, gas, or an explosion.
- If a battery is subjected to extremely low air pressure, it may result in leakage of flammable liquid, gas, or an explosion.
CAUTION
Shock Hazard. Disconnect all power sources
Caution
This equipment is to be used in a Network Environment 0 per IECTR 62101. This
product is connected only to PoE networks without routing to the outside
plant. This product has a separate protective earthing terminal provided on
the back of the product in addition to the grounding terminal of the
attachment plug. This separate protective earthing the terminal must be
permanently connected to earth with a green with yellow stripe conductor
minimum size #12AWG and the connection is to be installed by qualified service
personnel
Disconnect the ES2 (TNV) circuit connector before removing the cover
IMPORTANT SAFETY INSTRUCTIONS – When using your telephone equipment,
basic safety precautions should always be followed to reduce the risk of fire,
electric shock and injury to
persons, including the following:
- Do not use this product near water for example, near a bathtub, washbowl, kitchen sink or laundry tub, in a wet basement or near a swimming pool
- Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning.
- Do not use the telephone to report a gas leak in the vicinity of the leak
- Use only the power cord and batteries indicated in this manual. Do not dispose of batteries in a fire. They may explode. Check with local codes for possible special disposal instructions
CONSERVER CES INSTRUCTIONS
CAUTION: To reduce the risk of fire, use only No. 26 AWG or larger (e.g.,
24 AWG) UL Listed or CSA Certified Telecommunication Line Cord
Grounding — To prevent damage to your equipment, connections that enter from outside the building should pass through a lightning/surge protector, and be properly grounded. Use an electrostatic discharge workstation (ESD) and/or wear an anti-static wrist strap while you work.
In addition to the grounding terminal of the plug, on the back panel, there is another, separate terminal for earthing. This product has a separate protective earthing terminal provided on the back of the product in addition to the grounding terminal of the attachment plug. This separate protective earthing the terminal must be permanently connected to earth with a green with yellow stripe conductor minimum size # 12AWG and the connection is to be installed by qualified service personnel.
Warning
Equipment intended for installation in a Restricted Access Location.
Federal Communication Commission (FCC) – USA
This device complies with Part 15 of FCC Rules. Operation is subject to the
following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received; including interference
that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
B digital device, under Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in residential
installation. This equipment generates, uses, and can radiate radio frequency
energy, and if it is not installed and used by the instruction manual, it may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
WARNING: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
This equipment complies with ANSI TIA/EIA/968-B and Part 68 of the FCC rules and the requirements adopted by the ACTA. On the base of this equipment is a label that contains, among other information, a product identifier in the format US: AAAEQ##TXXXX. If requested, this number must be provided to the telephone company.
This equipment uses the following USOC jacks: RJ11. A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA. A compliant telephone cord and modular plug are provided with this product. It is designed to be connected to a compatible modular jack that is also compliant. See installation instructions for details.
The REN is used to determine the number of devices that may be connected to a telephone line. Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call. In most but not all areas, the sum of RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to a line, as determined by the total REN, contact the local telephone company. The REN for this product is separately shown on the label and also part of the product identifier that has the format US: AAAEQ##TXXXX. The digits represented by ## are the REN without a decimal point (e.g., 03 is a REN of 0.3).
If you experience trouble with this equipment, for repair or warranty
information, please refer to Fortinet’s End-User License Agreement which sets
forth the terms and limitations of Fortinet’s product warranty and contact the
following address and phone number for additional information. Fortinet, Inc.
899 Kifer Road, Sunnyvale, CA 94086 USA
1-866-393-9960 (US and Canada)
1-613-725-2466 (International)
http://www.fortinet.com
It is recommended that the customer install an AC surge arrester in the AC outlet to which this device is connected. This is to avoid damaging the equipment caused by local lightning strikes and other electrical surges. This equipment may not be used on the coin service provided by the telephone company. Connection to party line service is subject to state tariffs.
Industry Canada Equipment Standard for Digital Equipment (ICES) – Canada
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du
Canada.
Industry Canada (IC CS) – Canada
NOTICE: This product meets the applicable Industry Canada terminal
technical specifications. This is confirmed by the registration number. The
abbreviation, IC, before the registration number signifies that registration
was performed based on a Declaration of Conformity indicating that Industry
Canada’s technical specifications were met. It does not guarantee the
equipment will operate to the user’s satisfaction.
NOTICE: The Ringer Equivalence Number (REN) for this terminal equipment
is 0.1. The REN assigned to each terminal equipment indicates the maximum
number of
terminals allowed to be connected to a telephone interface. The termination on
an interface may consist of any combination of devices subject only to the
requirement that the sum of
the Ringer Equivalence Numbers of all the devices does not exceed five.
Innovation, Science and Economic Development (ISED) – Canada
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject
to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. This device and its antennas(s) must not be co-located or operating in conjunction with any other antenna or transmitter except by the IC multi-transmitter product procedures.
European Conformity (CE) – EU
This is a Class B product. In a domestic environment, this product may cause
radio interference, in which case the user may be required to take adequate
measures. The product transmits within the frequency ranges and less than or
equal to the power listed below:2402-2480MHz less than 20dBm. This equipment
should be installed and operated with a minimum distance of 20cm between the
radiator & your body.
Simplified EU Declaration of Conformity
This declaration is only valid for Fortinet products (including combinations
of software, firmware and hardware) provided by Fortinet or Fortinet’s
authorized partners to the end-customer
directly for use within the EU or countries that have implemented the EU
Directives and/or spectrum regulation. Any Fortinet products not obtained
directly from Fortinet or Fortinet’s authorized partners may not comply with
EU Directives and Fortinet makes no assurances for such products.
This product complies with Directive 2014/53/EU.
UK Conformity Assessed (UKCA) – United Kingdom
The product transmits within the frequency ranges and less than or equal to
the power listed below:2402-2480MHz less than 20dBm. This equipment should be
installed and operated with a minimum distance of 20cm between the radiator &
your body. This product complies with Statutory Instrument 1206 Radio
Equipment Regulations 2017 The full Declaration of Conformity for this product
is available in the link
below:https://site.fortinet.com/ProductRegulatory/UK
This document is prepared in English and French. In case of conflict between them, the English version shall prevail over the French version. This guide covers: FG-80F, FG-81F, FG-80F-Bypass, FG-80F-POE, FG-81F-POE, and FG-80F-DSL January 20, 2023
Copyright® 2022 Fortinet, Inc. All rights reserved. Fortinet®, FortiGate®, FortiCare® and FortiGuard®, and certain other marks are registered trademarks of Fortinet. All other product or company names may be trademarks of their respective owners. Performance and other metrics contained herein were attained in internal lab tests under ideal conditions, and actual performance and other results may vary. Network variables, different network environments and other conditions may affect performance results.
Nothing herein represents any binding
commitment by Fortinet and Fortinet disclaims all warranties, whether express
or implied, except to the extent Fortinet enters a binding written contract,
signed by Fortinet’s General Counsel, with a purchaser that expressly warrants
that the identified product will perform according to certain expressly
identified performance metrics and, in such event, only the specific
performance metrics expressly identified in such a binding written contract
shall be binding on Fortinet. For absolute clarity, any such warranty will be
limited to performance in the same ideal conditions as in Fortinet’s internal
lab tests.
In no event does Fortinet make any commitment related to future deliverables, features or development, and circumstances may change such that any forward- looking statements herein are not accurate. Fortinet disclaims in full any covenants, representations, and guarantees pursuant hereto, whether express or implied.
Fortinet reserves the right to change or modify. transfer, or otherwise revise this publication without notice, and the most current version of the publication shall be applicable. For Product License Agreement / EULA and Warranty Terms, visit https://www.fortinet.com/content/dam/fortinet/assets/legal/EULA.pdf
References
- LoginMgr
- Global Leader of Cybersecurity Solutions and Services | Fortinet
- Anatel — Agência Nacional de Telecomunicações
- Global Leader of Cybersecurity Solutions and Services | Fortinet
- Fortinet Document Library | Home
- Product Downloads | Fortinet Product Downloads | Support
- Welcome
- Fortinet Contact Support Information
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>