FORTINET FG-90G Forti Gate User Guide
- June 1, 2024
- FORTINET
Table of Contents
QuickStart Guide
FortiGate 90G Series
FG-90G, FG-91G
FG-90G Forti Gate
Before you begin
Register your device to access FortiGuard updates, cloud management, firmware
upgrades, technical support, and warranty coverage.
https://support.fortinet.com
FortiExplorer App
Rapidly provision, deploy, and monitor Security Fabric components including
FortiGate and FortiWiFi devices from your mobile. Download now for free.
Download FortiExplorer for your OS:
https://links.fortinet.com/fortiexplorer/downloads
This guide covers: FG-90G, FG-91G
January 25, 2024
Copyright© 2024 Fortinet, Inc. All rights reserved. Fortinet®, FortiGate®,
FortiCare® and FortiGuard®, and certain other marks are registered trademarks
of Fortinet, Inc., in the U.S. and other jurisdictions, and other Fortinet
names herein may also be registered and/or common law trademarks of Fortinet.
All other product or company names may be trademarks of their respective
owners. Performance and other metrics contained herein were attained in
internal lab tests under ideal conditions, and actual performance and other
results may vary. Network variables, different network environments and other
conditions may affect performance results. Nothing herein represents any
binding commitment by Fortinet, and Fortinet disclaims all warranties, whether
express or implied, except to the extent Fortinet enters a binding written
contract, signed by Fortinet’s Chief Legal Officer, with a purchaser that
expressly warrants that the identified product will perform according to
certain expressly-identified performance metrics and, in such event, only the
specific performance metrics expressly identified in such binding written
contract shall be binding on Fortinet. For absolute clarity, any such warranty
will be limited to performance in the same ideal conditions as in Fortinet’s
internal lab tests. In no event does Fortinet make any commitment related to
future deliverables, features or development, and circumstances may change
such that any forward-looking statements herein are not accurate. Fortinet
disclaims in full any covenants, representations, and guarantees pursuant
hereto, whether express or implied. Fortinet reserves the right to change,
modify, transfer, or otherwise revise this publication without notice, and the
most current version of the publication shall be applicable.
For Product License Agreement / EULA and Warranty Terms, visit
https://www.fortinet.com/content/dam/fortinet/assets/legal/EULA.pdf
The Essentials
Default Logins
https://192.168.1.99
Username: admin
Password:(leave blank)
Admin Guide
For a detailed Getting Started guide, setup, and configuration information,
refer to the Admin Guide on https://docs.fortinet.com/
Customer Service
For contracts, licensing, product registration, and account management,
contact FortiCare Support at https://www.fortinet.com/support/contact
Self-service Resources
Access our knowledge base, forums, videos and technical experts at
https://www.fortinet.com/support/support-services/forticare-support Thank
you for choosing Fortinet
Contents
FortiGate 90G Series
FG-90G, FG-91G
Setup
Unpack the box, power the device and choose one of the following options:
FortiExplorer
https://links.fortinet.com/fortiexplorer/downloads
Note: Enable Bluetooth on your mobile device for BLE or connect your mobile USB cable into the device
Note: Configure the management computer with IP 192.168.1.x and subnet 255.255.255.0
Note: For a detailed CLI guide, visit https://docs.fortinet.com
FortiGate Cloud
Note: Browse to https://forticloud.com and follow the on-screen instructions
Front FG-90G
-
BLE LED
Flashing Blue: Discovery mode
Blue: BLE connected
Off: BLE off -
RESET Reset and BLE management button
-
HA
Green: Operating in an HA cluster
Amber: HA failover
Off: Not in an HA cluster
POWER
Green: Both PSUs functioning
Amber: One PSU functioning
Off: Power is off
STATUS
Flashing Green: Booting up
Green: Operating normally
Off: Device is off -
USB (USB A) USB 3.0 server port
CONSOLE (RJ45) CLI management connection, default IP 192.168.1.99 -
SFP+ Ports (x2) shared with WAN ports
Green: Connected at 10Gbps
Flashing Green: Data activity
Off: No link established -
WAN Ports (x2) shared with SFP+ ports
LINK/ACT (Left LED)
Green: Connected
Flashing Green: Data Activity
Off: No activity
SPEED (Right LED)
Green: 10Gbps
Amber: 5/2.5/1Gbps
Off: 100Mbps or off -
Ports 1 to 6 and FortiLink Ports A & B
LINK/ACT (Left LED)
Green: Connected
Flashing Green: Data Activity
Off: No activity
SPEED (Right LED)
Green: 1Gbps
Amber: 100Mbps
Off: 10Mbps or off
Rear FG-90G
Power Input 12VDC 3A, 100-240VAC 50/60Hz (optional redundant power adapter and cable available for purchase)
Cautions and Warnings
Environmental specifications
Ambient operating temperature: 0°C to 40°C
Rack Mount Instructions – The following or similar rack-mount instructions are
included with the installation instructions:
Instructions de montage en rack – Les instructions de montage en rack
suivantes ou similaires sont incluses avec les instructions d’installation:
Elevated Operating Ambient – If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be
greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum ambient
temperature (Tma) specified by the manufacturer.
Reduced Air Flow – Installation of the equipment in a rack should be such that
the amount of air flow required for safe operation of the equipment is not
compromised.
Mechanical Loading – Mounting of the equipment in the rack should be such that
a hazardous condition is not achieved due to uneven mechanical loading.
Circuit Overloading – Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the
circuits might have on overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be used when addressing
this concern.
Refer to specific Product Model Data Sheet for Environmental Specifications
(Operating Temperature, Storage Temperature, Humidity, and Altitude)
Safety
Battery – Risk of explosion if the battery is replaced by an incorrect type.
Do not dispose of batteries in a fire. They may explode. Dispose of used
batteries according to your local regulations. IMPORTANT: Switzerland: Annex
4.10 of SR814.013 applies to batteries.
CAUTION: Shock Hazard. Disconnect all power sources.
This product is intended to be supplied by a Listed Direct Plug-In Power Unit
marked LPS or Class 2 and rated 12 Vdc, 3 A.
Grounding — To prevent damage to your equipment, connections that enter
from outside the building should pass through a lightning / surge protector,
and be prgrounded. Use an electrostatic discharge workstation (ESD) and/or
wear an anti-static wrist strap while you work. In addition to the grounding
terminal of the plug, oback panel, there is another, separate terminal for
earthing.
This product has a separate protective earthing terminal provided on the back
of the product in addition to the grounding terminal of the attachment plug.
This separate protective earthing terminal must be permanently connected to
earth with a green with yellow stripe conductor minimum size #12AWG and the
connection is to be installed by a qualified service personnel.
Regulatory Notices
Federal Communication Commission (FCC) – USA
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received; including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
WARNING: Any changes or modifications to this unit not expressly approved
by the party responsible for compliance could void the users authority to
operate the equipment
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance of 20cm between the radiator and your body. This transmitter
must not be co-located or operating in conjunction with any other antenna or
transmitter.
Industry Canada Equipment Standard for Digital Equipment (ICES) – Canada
This Class B digital apparatus complies with Canadian ICES-003.
Innovation, Science and Economic Development (ISED) – Canada
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s).
Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
This equipment complies with ISED radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance of 20cm between the radiator & your body.
This radio transmitter (IC:7280B-111T17) has been approved by ISED to operate
with the antenna types listed below with the maximum permissible gain and
required antenna impedance for each antenna type indicated. Antenna types not
included in this list, having a gain greater than the maximum gain indicated
for that type, are strictly prohibited for use with this device.
This device and it’s antennas(s) must not be co-located or operating in
conjunction with any other antenna or transmitter except in accordance with IC
multi-transmitter product procedures.
Antenna | Manufacturer | Model | Antenna Type | Connector | Antenna Peak Gain |
---|---|---|---|---|---|
1 | JOYMAX | IHF-2120MPX9-W018 | Monopole | I-PEX MHF1 | 1.53 dBi for 2.4GHz(BT) |
European Conformity (CE) – EU
This is a Class B product. In a domestic environment, this product may cause
radio interference, in which case the user may be required to take adequate
measures.
The product transmits within the frequency ranges and less than or equal to
the power listed below: 2402-2480MHz less than 20dBm
This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.
Simplified EU Declaration of Conformity
This declaration is only valid for Fortinet products (including combinations
of software, firmware and hardware) provided by Fortinet or Fortinet’s
authorized partners to the end-customer directly for use within the EU or
countries that have implemented the EU Directives and/or spectrum regulation.
Any Fortinet products not obtained directly from Fortinet or Fortinets
authorized partners may not comply with EU Directives and Fortinet makes no
assurances for such products.
This product is in compliance with Directive 2014/53/EU.
Note: The full Declaration of Conformity for this product is available in
the link below: https://site.fortinet.com/ProductRegulatory/EU
Voluntary Control Council for Interference (VCCI) – Japan
Product Safety Electrical Appliance & Material (PSE) – Japan
Bureau of Standards Metrology and Inspection (BSMI) – Taiwan
https://www.fortinet.com/bsmi
National Telecommunications Commission (NCC) – Taiwan
UK Conformity Assessed (UKCA) – United Kingdom
The product transmits within the frequency ranges and less than or equal to
the power listed below: 2402-2480MHz less than 20dBm
This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.
This product is in compliance with Statutory Instrument 1206 Radio Equipment
Regulations 2017
The full Declaration of Conformity for this product is available in the link
below: https://site.fortinet.com/ProductRegulatory/UK
References
- Global Leader of Cybersecurity Solutions and Services | Fortinet
- Anatel — Agência Nacional de Telecomunicações
- Fortinet Document Library | Home
- LoginMgr
- Product Downloads | Fortinet Product Downloads | Support
- Welcome
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>