Fortinet FAP-441K Wireless Access Point User Guide

June 1, 2024
FORTINET

FAP-441K Wireless Access Point

“`html

Specifications

  • Model: FortiAP 441K, 443K

  • Device Types: FAP-441K, FAP-443K

  • Power Options: 802.3af/at PoE injector, FortiGate PoE port,
    optional 12V 4A power adapter

  • Antenna Installation: Available for FAP-443K only

  • Interfaces: LED Status, Optional Power 12V DC 4A adapter,
    Reset, Console (RJ45), LAN2/PoE 10G (RJ45), LAN1/PoE 10G (RJ45),
    GPS (SMA)

Product Usage Instructions

FortiLAN Cloud Setup

  1. Connect FortiAP LAN Port to Ethernet Cable.

  2. Access https://fortilan.forticloud.com and log in with
    FortiCloud credentials.

  3. Click Inventory, Import AP Key, and enter the Cloud Key from
    the device sticker.

Direct Connection Setup

  1. Connect FortiAP LAN Port to Ethernet Cable.

  2. Connect the other end of the cable to FortiGate Ethernet
    Port.

  3. Preauthorize the FortiAP on your FortiGate or wait for it to
    appear on the Managed FortiAP page in FortiOS.

Network Connection Setup

  1. Connect FortiAP LAN Port to Ethernet Cable.

  2. Connect the other end to FortiGate Ethernet Port.

  3. Access 192.168.1.2 using username ‘admin’ and set a
    password.

  4. Specify the FortiGate IP using command: cfg -a
    AC_IPADDR=0.0.0.0

Bracket and Antenna Installation

  1. Mount the FortiAP on a ceiling using the provided T-rail
    mounting brackets (1.43cm or 2.38cm).

  2. For FAP-443K, insert antennas into the appropriate mounts and
    secure them.

  3. Position the device against the ceiling T-rail and snap it into
    place.

Frequently Asked Questions (FAQ)

How do I access the device’s default logins?

You can access the device with the following default
logins:
https://192.168.1.2 Username: admin Password: leave blank
https://fortilan.forticloud.com Username: user-defined Password:
user-defined

Where can I find detailed setup and configuration

information?

You can refer to the Admin Guide available at
https://docs.fortinet.com/product/fortiap for detailed setup and
configuration instructions.

How can I register for updates and support resources?

To register for FortiGuard updates, cloud management, firmware
upgrades, technical support, and warranty coverage, visit
https://support.fortinet.com

“`

QuickStart Guide
FortiAP 441K, 443K
FAP-441K, FAP-443K

The Essentials

Default Logins

https://192.168.1.2 Username: admin Password: leave blank

https://fortilan.forticloud.com Username: user-defined Password: user-defined

Admin Guide
For a detailed FortiAP setup and configuration information, refer to the Admin Guide on https://docs.fortinet.com/product/fortiap
Support Resources
Register for FortiGuard updates, cloud management, firmware upgrades, technical support and warranty coverage at https://support.fortinet.com

Thank you for choosing Fortinet

Package Contents
FortiAP 441K / 443K FAP-441K*, FAP-443K**

QuickStart Guide

FortiAP Device*

FortiAP Antenna Device**

9/16″ Ceiling Mounting Bracket

15/16″ Ceiling Mounting Bracket

8x Mounting Screws with 8x Anchors

10x Antennas**

2

3

Setup Options
Power the FortiAP device with a 802.3af/at PoE injector, FortiGate PoE port or the optional (not included) 12V 4A power adapter.

FortiLAN Cloud
1
FortiAP LAN Port

2
Ethernet Cable (not included)

3
FortiLAN Cloud
https://fortilan.forticloud.com

Note: Use your FortiCloud credentials to log in, then click Inventory, Import AP Key and enter the Cloud Key on the device sticker

Direct Connection
1

FortiAP LAN Port

2
Ethernet Cable (not included)

3
FortiGate Ethernet Port

Note: To self-configure, preauthorize the FortiAP on your FortiGate Otherwise once connected, wait for the FortiAP to appear on the Managed FortiAP page in FortiOS.

4

Network Connection
1

FortiAP LAN Port

2
Ethernet Cable (not included)

3

4

Same Network

FortiGate Ethernet Port

Note: Connect to the FortiAP using 192.168.1.2 with username admin and set a password. Specify the FortiGate IP using:
cfg -a AC_IPADDR=0.0.0.0
cfg -c where 0.0.0.0 is the FortiGate IP.

5

Bracket Installation
The FortiAP mounts on a ceiling using the provided T-rail mounting brackets which come in two standard sizes: 1.43cm (9/16in) and 2.38cm (15/16in).
1. Select the bracket for the T-rail size: 1.43cm (9/16in) or 2.38cm (15/16in) 2. With the ports facing you, slide the bracket left to right

Antenna Installation (FAP-443K only)
1. Insert the antenna base firmly into the appropriate antenna mount 2. Securely hand tighten the antenna fastening collar 3. Repeat for the remaining antennas

A4 – 2.4/5GHz

A5 – 6Ghz

A5 – 6Ghz

A7 – 2.4/5Ghz

3. Hold the device against the ceiling T-rail and push until it snaps into place

A3 -2.4/5/6GHz A2 – 6GHz

A1 – 2.4/5GHz

A8 – 2.4/5/6Ghz A9 – 6Ghz
A10 – 2.4/5Ghz

6

7

Interfaces – FAP 441K / 443K
1 234 5 6 7
8

1 LED STATUS
Power Off: Device off Green: Device on and connected to a controller Amber: Device on and not connected to a controller LAN Off: Not connected Green: Connected Blinking Green: Data activity WiFi Off: WiFi not broadcasting Green: SSID broadcasting Blinking Green: Data activity
2 OPTIONAL POWER 12V DC 4A adapter
3 RESET system reset
4 CONSOLE (RJ45) CLI management
5 LAN2 / POE 10G (RJ45) 10 Gbps 802.3at/802.3bt PoE Ethernet interface
6 LAN1 / POE 10G (RJ45) 10 Gbps 802.3at/802.3bt PoE Ethernet interface
7 GPS (SMA) Multi-GNSS connection
9

Cautions and Warnings
Environmental specifications
Ambient operating temperature: 0°C to 50°C
Refer to specific Product Model Data Sheet for Environmental Specifications (Operating Temperature, Storage Temperature, Humidity, and Altitude) Référez à la Fiche Technique de ce produit pour les caractéristiques environnementales (Température de fonctionnement, température de stockage, humidité et l’altitude).
Safety
Caution: This equipment is to be used in a Network Environment 0 per IECTR 62101. This product is connected only to PoE networks without routing to the outside plant. Attention: Ce matériel doit être utilisé dans un Environnement Réseau 0 par IECTR 62101. Ce produit est uniquement connecté aux réseaux PoE sans installation externe de routage.
This product is intended to be supplied by a Listed Direct Plug-In Power Unit marked LPS or Class 2 and rated 12Vdc, 4A or by 54Vdc from PoE source. Le produit doit être alimenté par un bloc d’alimentation à courant continu homologué UL de 12Vdc, 4A nominal marqué LPS ou Class 2 ou par une source d’alimentation par Ethernet de 54 Vdc (PoE).
Regulatory Notices
Federal Communication Commission (FCC) ­ USA
This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received; including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
WARNING: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 53 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Caution: For 6ID (Indoor Access Point) & UNII-4 (Indoor AP) a. FCC regulations restrict the operation of this device to indoor use only. b. The operation of this device is prohibited on oil platforms, cars, trains, boats, and aircraft, except that operation of this device is permitted in large aircraft while flying above 10,000 feet. c. Operation of transmitters in the 5.925-7.125 GHz band is prohibited for control of or communications with unmanned aircraft systems.
This device meets all the other requirements specified in Part 15E, Section 15.407 of the FCC Rules.
Industry Canada Equipment Standard for Digital Equipment (ICES) ­ Canada
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
Innovation, Science and Economic Development (ISED) ­ Canada
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licenceexempt RSS(s). Operation is subject to the following two conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: 1. L’appareil ne doit pas produire de brouillage; 2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
For product available in the USA/Canada market, only channel 1~11 can be operated. Selection of other channels is not possible.
Pour les produits disponibles aux États-Unis / Canada du marché, seul le canal 1 à 11 peuvent être exploités. Sélection d’autres canaux n’est pas possible.
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 31 cm between the radiator & your body.
Cet équipement est conforme aux limites d’exposition aux rayonnements ISED établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 31 cm de distance entre la source de rayonnement et votre corps.
10

Antenna

Port

1

1

2

2

3

3

4

4

5

1

6

2

7

3

8

4

9

1

10

2

11

1

12

1

13

2

2.4G 2.95 3.38 2.05 2.18
1.76 1.17 –

Max Gain (dBi)

5G

6G

BT/Zigbee

5.28

2.9

6.22

4.55

4.26

5.89

5.27

4.86

5.11

4.41

2.91

4.43

4.5

GPS –
-0.5 1.4

The maximum antenna gain permitted for devices in the band 5725-5850 MHz shall be such that the equipment still complies with the e.i.r.p. limits specified for point-to-point and non-point-to-point operation as appropriate. Le gain maximal d’antenne permis (pour les dispositifs utilisant la bande 5725-5850 MHz) doit se conformer à la limite de p.i.r.e. spécifiée pour l’exploitation point à point et non point à point, selon le cas.
The worst-case tilt angle(s) necessary to remain compliant with the e.i.r.p. elevation mask requirement set forth in Section 6.2.2(3) shall be clearly indicated. Les pires angles d’inclinaison nécessaires pour rester conforme à l’exigence de la p.i.r.e. applicable au masque d’élévation, et énoncée à la section 6.2.2 3), doivent être clairement indiqués.
Caution: The device for the band 5150-5250 MHz is only for indoor usage to reduce potential for harmful interference to co-channel mobile satellitesystems. Attention: Le dispositif de la bande 5150-5250 MHz est réservé à un usage intérieur afin de réduire l’interférence nuisible potentielle aux systèmes mobiles par satellite co-canal.
Caution: The maximum antenna gain permitted for devices in the bands 5250-5350 MHz and 5470-5725 MHz shall comply with the e.i.r.p. limit; and the maximum antenna gain permitted for devices in the band 5725-5825 MHz shall comply with the e.i.r.p. limits specified for point-to-point and non point-to-point operation as appropriate. Attention: Le gain maximal d’antenne permis pour les dispositifs utilisant les bandes 5 250-5 350 MHz et 5 470-5 725 MHz doit se conformer à la limite de p.i.r.e.; le gain maximal d’antenne permis (pour les dispositifs utilisant la bande 5 725-5 825 MHz doit se conformer à la limite de p.i.r.e. spécifiée pour l’exploitation point à point et non point à point, selon le cas.
This device has been designed to operate with an antenna having a maximum gain of 3.38 dBi for 2.4GHz, 6.22 dBi for 5GHz and 5.89 dBi for 6GHz. Antenna having a higher gain is strictly prohibited per regulations of ISED. The required antenna impedance is 50 ohms. Under ISED regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by ISED. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotopically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
Ce dispositif a été conçu pour fonctionner avec une antenne ayant un gain maximal de 3.38 dBi for 2.4GHz, 6.22 dBi for 5GHz and 5.89 dBi for 6GHz pour 5GHz. Une antenneayant un gain supérieur sont strictement interdites par la réglementation d’ISED. L’impédance d’antenne requise est de 50 ohms. Conformément à la réglementation d’ISED, cet émetteur radio peut fonctionner seulement avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par ISED. Dans le but de réduire les risques de brouillage radioélectrique aux autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication réussie.
This radio transmitter (IC: 7280B-512178E8741) has been approved by ISED to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
Le présent émetteur radio (IC: 7280B-512178E8741) a été approuvé par ISED pour fonctionner avec les types d’antenne énumérés ci-dessous et ayant un gain admissible maximal et l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur.
This device and it’s antennas(s) must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with IC multi-transmitter product procedures. Cet appareil et son antenne (s) ne doit pas être co-localisés ou fonctionnement en association avec une autre antenne ou transmetteur.
Devices shall not be used for control of or communications with unmanned aircraft systems. Operation shall be limited to indoor use only. Operation on oil platforms, automobiles, trains, maritime vessels and aircraft shall be prohibited except for on large aircraft flying above 3,048 m (10,000 ft).
Les dispositifs ne doivent pas être utilisés pour commander des systèmes d’aéronef sans pilote ni pour communiquer avec de tels systèmes. Leur utilisation doit être limitée à l’intérieur seulement. Leur utilisation à bord de plateformes de forage pétrolier, d’automobiles, de trains, de navires maritimes et d’aéronefs doit être interdite, sauf à bord d’un gros aéronef volant à plus de 3 048 m (10 000 pi) d’altitude.

.

11

European Conformity (CE) ­ EU This is a Class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Simplified EU Declaration of Conformity This declaration is only valid for Fortinet products (including, combinations of software, firmware and hardware) provided by Fortinet or Fortinet’s authorized partners to the end customer directly for use within the EU or countries that have implemented the EU Directives and/or spectrum regulation. Any Fortinet products not obtained directly from Fortinet or Fortinet’s authorized partners may not comply with EU Directives and Fortinet makes no assurances for such products. 2014/53/. Cesky Tento produkt je v souladu se smrnicí 2014/53/EU. Dansk Dette produkt er i overensstemmelse med direktiv 2014/53/EU. Deutsch Dieses Produkt entspricht der Richtlinie 2014/53/EU. Eesti See toode vastab direktiivile 2014/53/EL. English This product is in compliance with Directive 2014/53/EU. Español Este producto cumple con la Directiva 2014/53/UE. 2014/53/. Français Ce produit est conforme à la Directive 2014/53/UE. Hrvatski Ovaj proizvod je u skladu s Direktivom 2014/53/EU. Italiano Questo prodotto è conforme alla Direttiva 2014/53/EU. Latviski Sis produkts atbilst Direktvai 2014/53/EU. Lietuvi Sis gaminys atitinka direktyv 2014/53/ES. Malti Dan il-prodott huwa konformi mad- Direttiva 2014/53/UE. Magyar Ez za termék megfelel a 2014/53/EU irányelvnek. Nederlands Dit product is in overeenstemming met Richtlijn 2014/53/EU. Norsk Dette produktet er i samsvar med direktiv 2014/53/EU. Polski Ten produkt jest zgodny z dyrektyw 2014/53/UE. Português Este produto está em conformidade com a Diretiva 2014/53/UE. Rumunski Acest produs este în conformitate cu Directiva 2014/53/UE. Slovensky Tento produkt je v súlade so smernicou 2014/53/EÚ. Slovensko Ta izdelek je v skladu z Direktivo 2014/53/EU. Suomi Tämä tuote on direktiivin 2014/53/EU mukainen. Svenska Denna produkt överensstämmer med direktiv 2014/53/EU. Note: The full declaration of conformity for this product is available at the link below: https://site.fortinet.com/ProductRegulatory/EU
12

The device is restricted to indoor use only when operating in the 5150 to 5350 MHz and 6GHz frequency range in the following countries:

Compliance with 2014/53/EU Radio Equipment Directive (RED)
In accordance with Article 3.1(a) , 3.1(b) , 3.2of the RED, the following table provides information on the frequency bands used and the maximum RF transmit power of the product for sale in the EU:

Frequency Range (MHz) Bluetooth: 2402-2480MHz
Zigbee: 2405-2480MHz WLAN 2.4GHz: 2412-2472MHz WLAN 5GHz: 5180-5320MHz WLAN 5GHz: 5500-5700MHz WLAN 6GHz: 5725-5875MHz WLAN 6GHz: 5955-6415MHz

Max. Transmit Power (dBm) 10 10 20 23 30 14 23

UK Conformity Assessed (UKCA) ­ United Kingdom The product transmits within the frequency ranges and less than or equal to the power listed below:

Frequency Range (MHz) Bluetooth: 2402-2480MHz
Zigbee: 2405-2480MHz WLAN 2.4GHz: 2412-2472MHz WLAN 5GHz: 5180-5320MHz WLAN 5GHz: 5500-5700MHz WLAN 6GHz: 5725-5875MHz WLAN 6GHz: 5955-6415MHz

Max. Transmit Power (dBm) 10 10 20 23 30 14 23

This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This product is in compliance with Statutory Instrument 1206 Radio Equipment Regulations 2017 Operations in the 5.15-5.35GHz and 5925-6425MHz band are restricted to indoor usage only. The full Declaration of Conformity for this product is available in the link below: https://site.fortinet.com/ProductRegulatory/UK
National Telecommunications Commission (NCC) ­ Taiwan
.

13

14

15

November 30, 2023
Copyright© 2023 Fortinet, Inc. All rights reserved. Fortinet®, FortiGate®, FortiCare® and FortiGuard®, and certain other marks are registered trademarks of Fortinet, Inc., in the U.S. and other jurisdictions, and other Fortinet names herein may also be registered and/or common law trademarks of Fortinet. All other product or company names may be trademarks of their respective owners. Performance and other metrics contained herein were attained in internal lab tests under ideal conditions, and actual performance and other results may vary. Network variables, different network environments and other conditions may affect performance results. Nothing herein represents any binding commitment by Fortinet, and Fortinet disclaims all warranties, whether express or implied, except to the extent Fortinet enters a binding written contract, signed by Fortinet’s General Counsel, with a purchaser that expressly warrants that the identified product will perform according to certain expressly-identified performance metrics and, in such event, only the specific performance metrics expressly identified in such binding written contract shall be binding on Fortinet. For absolute clarity, any such warranty will be limited to performance in the same ideal conditions as in Fortinet’s internal lab tests. In no event does Fortinet make any commitment related to future deliverables, features or development, and circumstances may change such that any forward-looking statements herein are not accurate. Fortinet disclaims in full any covenants, representations, and guarantees pursuant hereto, whether express or implied. Fortinet reserves the right to change, modify, transfer, or otherwise revise this publication without notice, and the most current version of the publication shall be applicable.
For Product License Agreement / EULA and Warranty Terms, visit https://www.fortinet.com/content/dam/fortinet/assets/legal/EULA.pdf
FAP-441K-443K-QSG-20231129

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FORTINET User Manuals

Related Manuals