FORTINET FGR-70G-5G DUAL FortiGate Rugged 70G 5G User Guide

May 15, 2024
FORTINET

FORTINET logo

QuickStart Guide
FortiGate Rugged 70G 5G Dual
FGR-70G-5G-DUAL

The Essentials

Default Logins
https://192.168.1.99
Username: admin
Password: leave blank

Fortinet Documents Library
For a detailed administration guide, up-to-date hardware manuals and reference materials, visit https://docs.fortinet.com/

Support Resources
Register for FortiGuard updates, cloud management, firmware upgrades, technical support and warranty coverage at https://support.fortinet.com

FortiExplorer Go
Rapidly provision, deploy, and monitor Security Fabric components using a mobile device.

Download FortiExplorer Go for your iOS device:
https://links.fortinet.com/fortiexplorer/downloads

Package Contents

FORTINET FGR 70G 5G DUAL FortiGate Rugged 70G 5G - Package
Contents

FortiGate Rugged 70G-5G-DUAL
FGR-70G-5G-DUAL

Power Installation

Warnings

  • The redundant DC inputs support negative ground (+12V to +125V DC) and positive ground (-12V to -125V DC), 3A Max
  • With the optional failover redundancy, if the primary DC input fails, the secondary DC input will supply power
  • DC1+ and DC2+ are the higher voltage potential pins and DC1- and DC2- are the lower voltage potential pins
  • Do not connect the DC+ terminal to a lower voltage potential than the DC- terminal
  • The voltage between DC+ and DC- must be +12V to +125V DC
  • The DC wire gauge maximum is 12 AWG; the minimum is 30 AWG
  • Consult a professional electrician to install the device and determine a suitable wire gauge and length

Connector Pinout
Connect DC1+ or DC2+ on the device terminal block to the DC power source, then connect the negative DC1- or DC2- on the terminal block.

DC Input Power DC+ Terminal DC- Terminal
Negative Ground +12V to +125V DC Ground
Positive Ground Ground -12V to -125V DC

Wiring

Grounding
Optional but recommended, connect earth ground using the lug plate or grounding screw. Grounding lug not included, sold separately.

Dimensions

FORTINET FGR 70G 5G DUAL FortiGate Rugged 70G 5G -
Dimensions

Mounting

FORTINET FGR 70G 5G DUAL FortiGate Rugged 70G 5G -
Mounting

Digital I/O Connector

Connector Description
NO2 Normally Open 2 Terminal
COM2 Common 2 Terminal
NC2 Normally Closed 2 Terminal SFP1
NO1 Normally Open Terminal
COM1 Common 1 Terminal
NC1 Normally Closed 1 Terminal
IN2+ Alarm Input 2
REF Alarm Input 1/2 Reference Ground
IN1+ Alarm Input 1

Micro SD Card Slot

Hot-swapping the Micro SD card is not supported. Power off the device before installing or uninstalling the Micro SD card. Micro SD card not included.
Refer to the Admin Guide for SD card details at https://docs.fortinet.com

Dual 5G Nano SIM Slots

SIM type is 4FF – Nano SIM. Industrial SIM cards recommended for extreme temperature environments. Refer to the datasheet for supported operating temperatures. For wireless configuration, visit https://docs.fortinet.com

Antenna Installation

Attach the supplied nine antennas to: ANT1-0, ANT1-1, ANT1-2, ANT1-3, ANT2-0, ANT2-1, ANT2-2, ANT2-3 & GPS.

FORTINET FGR 70G 5G DUAL FortiGate Rugged 70G 5G -
Installation

Setup

FortiExplorer Go
Enable Bluetooth on your mobile device for BLE.

FORTINET FGR 70G 5G DUAL FortiGate Rugged 70G 5G - QR Code
14https://links.fortinet.com/fortiexplorer/downloads

GUI
Configure the management computer with dynamic IP https://192.168.1.99 or static IP 192.168.1.x and subnet 255.255.255.0FORTINET FGR 70G 5G DUAL
FortiGate Rugged 70G 5G - GUI  CLI

FORTINET FGR 70G 5G DUAL FortiGate Rugged 70G 5G - CLI

FortiGate Cloud
Visit https://forticloud.com to leverage your FortiGate SD-WAN integrations and unified cloud management services.

Front FGR-70G-5G-DUAL

FORTINET FGR 70G 5G DUAL FortiGate Rugged 70G 5G -
DUAL

1. Antenna Connector (9x SMA)

2. 5G1, 5G2
Green: 5G connected
Amber: 4G/3G connected
Off: Not connected| SIM1, SIM2
Green: Detected
Off: Not detected
GPS
Green: On
Off: Off
---|---

3. 5G SIM slots (2x Nano 4FF)

4. Green: Alarm defined
Green: Alarm defined
Red: Alarm detected
Off: Alarm not defined| Alarm Output (OUT1, OUT2)
Green: Alarm defined
Red: Minor alarm detected
Flashing Red: Major alarm detected
Off: Output alarm not detected
---|---

5. Power Connector (DC1, DC2) Alarm disabled by default
Green: Power detected
Red: Alarm is on; no power detected
Off: No power detected

6. STA
Green: Operating normally
Red: Device error
Flashing Green: Booting up
Off: Device is off| HA
Green: HA enabled (normal)
Red: HA enabled (failover)
Off: HA disabled
---|---
ALM
Red: Major alarm detected
Amber: Minor alarm detected
Off: No alarm detected| PWR
Green: Power detected
Off: Power not detected

7. RST / BLE Press to enable BLE; press and hold for system reset when booting up
Blue: BLE connected
Flashing Blue: BLE in discovery
Off: BLE off
8. USB 2.0 port

9. CONSOLE (RJ45) CLI management SERIAL (RJ45) Data port

10.   Ports 1 to 4 (RJ45)
BYPASS Ports 1 & 2 only; bypass disabled by default
Green: Bypass off
Red: Bypass on

Speed (Left LED)
Green: 1 Gbps
Amber: 100 Mbps
ff: 10 Mbps or not connected| Activity/Link (Right LED)
Green: Link established
lashing Green: Data activity
Off: No link established
---|---

11.  Signed Firmware BIOS Security Level
Controlled by Signed Firmware Switch, see Admin Guide at https://docs.fortinet.com
Green: Security Level 2 (default)
Amber: Security Level 1
Red: Security Level 0

12. SFP1 & SFP2 (SFP)
Green: Link established
Flashing Green: Data activity
Off: No link established

13. BLE Antenna

14.   WAN1 (Top) & WAN2 (Bottom) (RJ45)

Speed (Left LED)
Green: 1 Gbps
Amber: 100 Mbps
Off: 10 Mbps or not connected| Activity/Link (Right LED)
Green: Link established
Flashing Green: Data activity
Off: No link established
---|---

Cautions and Warnings

Environmental specifications
Ambient operating temperature: -40°C to 75°C
Refer to specific Product Model Data Sheet for Environmental Specifications (Operating Temperature, Storage Temperature, Humidity, and Altitude)

Safety
Warning: Equipment intended for installation in Restricted Access Location.
A skilled person must install the equipment.
Warning: A readily accessible disconnect device shall be incorporated in the building installation wiring.
Warning: A UL Listed external disconnect device, i.e. circuit breaker or other, with over current protection suitable for local code(rated 15A recommended) shall be installed with this equipment
CAUTION: Shock Hazard. Disconnect all power sources.
Grounding — To prevent damage to your equipment, connections that enter from outside the building should pass through a lightning / surge protector, and be properly grounded. Use an electrostatic discharge workstation (ESD) and/or wear an anti-static wrist strap while you work. In addition to the grounding terminal of the plug, on the back panel, there is another, separate terminal for earthing.
This product has a separate protective earthing terminal provided on the back of the product in addition to the grounding terminal of the attachment plug. This separate protective earthing terminal must be permanently connected to earth with a green with yellow stripe conductor minimum size # 14 AWG and the connection is to be installed by a qualified service personnel.
Connect to NEC Class 2 power source

Regulatory Notices

Federal Communication Commission (FCC) – USA
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received; including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.

WARNING: Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Industry Canada Equipment Standard for Digital Equipment (ICES) – Canada

CAN ICES-003 (A) / NMB-003 (A)
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regula¬tions of the Canadian Department of Communications.

Innovation, Science and Economic Development (ISED) – Canada
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
This radio transmitter (IC: 7280B-21001T57) has been approved by ISED to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.

This device and it’s antennas(s) must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with IC multi-transmitter product procedures.

Antenna type Connector Gain (dBi) Network
Monopole I-PEX 1.53 Bluetooth

European Conformity (CE) – EU
This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.


The product transmits within the frequency ranges and less than or equal to the power listed below:

Standard Frequency Range Max. Transmit Power
Bluetooth 2402–2480 MHz 10 dBm (EIRP)

For FGR-70G-5G-DUAL:

Standard Frequency Range Transmit Power
WCDMA Band 1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink)
Band 8: 880-915MHz(Uplink);925-960MHz(Downlink) 24 dBm (Conducted)
LTE Band 1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink)

Band 3: 1710-1785MHz(Uplink); 1805-1880MHz(Downlink)
Band 7: 2500-2570MHz(Uplink); 2620-2690MHz(Downlink)
Band 8: 880-915MHz(Uplink);925-960MHz(Downlink)
Band 20: 832-862MHz(Uplink); 791-821MHz(Downlink)
Band 28: 703-748MHz(Uplink); 758-803MHz(Downlink)
Band 34: 2010-2025MHz
Band 38: 2570-2620MHz
Band 40: 2300-2400MHz
Band 41: 2496-2690MHz
Band 42: 3400-3600MHz
Band 43: 3600-3800MHz| 24 dBm (Conducted)
Band 41: 2496-2690MHz| 27 dBm (Conducted)
5G NR| n1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink)
n3: 1710-1785MHz(Uplink); 1805-1880MHz(Downlink)
n7: 2500-2570MHz(Uplink); 2620-2690MHz(Downlink)
n8: 880-915MHz(Uplink);925-960MHz(Downlink)
n20: 832-862MHz(Uplink); 791-821MHz(Downlink)
n28: 703-748MHz(Uplink); 758-803MHz(Downlink)
n38: 2570-2620MHz
n40: 2300-2400MHz
n41: 2496-2690MHz
n77: 3300-4200MHz
n78: 3300-3800MHz| 24 dBm (Conducted)
n41: 2496-2690MHz
n77: 3300-4200MHz
n78: 3300-3800MHz| 27 dBm (Conducted)

This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

Simplified EU Declaration of Conformity
This declaration is only valid for Fortinet products (including combinations of software, firmware and hardware) provided by Fortinet or Fortinet’s authorized partners to the end-customer directly for use within the EU or countries that have implemented the EU Directives and/or spectrum regulation. Any Fortinet products not obtained directly from Fortinet or Fortinet’s authorized partners may not comply with EU Directives and Fortinet makes no assurances for such products.

This product is in compliance with Directive 2014/53/EU.

Note: The full Declaration of Conformity for this product is available in the link below:
https://site.fortinet.com/ProductRegulatory/EU

Waste Electrical and Electronic Equipment (WEEE)
This symbol means that according to local laws and regulations your product and/or its battery shall be disposed of separately from household waste. When this product reaches its end of life, take it to a collection point designated by local authorities. Proper recycling of your product will protect human health and the environment.

UK Conformity Assessed (UKCA) – United Kingdom
The product transmits within the frequency ranges and less than or equal to the power listed below:

Standard Frequency Range Max. Transmit Power
Bluetooth 2402–2480 MHz 10 dBm (EIRP)
Standard Frequency Range Transmit Power
--- --- ---
WCDMA Band 1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink)
Band 8: 880-915MHz(Uplink);925-960MHz(Downlink) 24 dBm (Conducted)
LTE Band 1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink)

Band 3: 1710-1785MHz(Uplink); 1805-1880MHz(Downlink)
Band 7: 2500-2570MHz(Uplink); 2620-2690MHz(Downlink)
Band 8: 880-915MHz(Uplink);925-960MHz(Downlink)
Band 20: 832-862MHz(Uplink); 791-821MHz(Downlink)
Band 28: 703-748MHz(Uplink); 758-803MHz(Downlink)
Band 34: 2010-2025MHz
Band 38: 2570-2620MHz
Band 40: 2300-2400MHz
Band 41: 2496-2690MHz
Band 42: 3400-3600MHz
Band 43: 3600-3800MHz| 24 dBm (Conducted)
Band 41: 2496-2690MHz| 27 dBm (Conducted)
5G NR| n1: 1920-1980MHz(Uplink); 2110-2170MHz(Downlink)
n3: 1710-1785MHz(Uplink); 1805-1880MHz(Downlink)
n7: 2500-2570MHz(Uplink); 2620-2690MHz(Downlink)
n8: 880-915MHz(Uplink);925-960MHz(Downlink)
n20: 832-862MHz(Uplink); 791-821MHz(Downlink)
n28: 703-748MHz(Uplink); 758-803MHz(Downlink)
n38: 2570-2620MHz
n40: 2300-2400MHz
n41: 2496-2690MHz
n77: 3300-4200MHz
n78: 3300-3800MHz| 24 dBm (Conducted)
n41: 2496-2690MHz
n77: 3300-4200MHz
n78: 3300-3800MHz| 27 dBm (Conducted)

This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
This product is in compliance with Statutory Instrument 1206 Radio Equipment Regulations 2017
The full Declaration of Conformity for this product is available in the link below: https://site.fortinet.com/ProductRegulatory/UK

January 22, 2024
Copyright© 2024 Fortinet, Inc. All rights reserved. Fortinet®, FortiGate®, FortiCare® and FortiGuard®, and certain other marks are registered trademarks of Fortinet, Inc., in the U.S. and other jurisdictions, and other Fortinet names herein may also be registered and/or common law trademarks of Fortinet. All other product or company names may be trademarks of their respective owners. Performance and other metrics contained herein were attained in internal lab tests under ideal conditions, and actual performance and other results may vary. Network variables, different network environments and other conditions may affect performance results. Nothing herein represents any binding commitment by Fortinet, and Fortinet disclaims all warranties, whether express or implied, except to the extent Fortinet enters a binding written contract, signed by Fortinet’s General Counsel, with a purchaser that expressly warrants that the identified product will perform according to certain expressly-identified performance metrics and, in such event, only the specific performance metrics expressly identified in such binding written contract shall be binding on Fortinet. For absolute clarity, any such warranty will be limited to performance in the same ideal conditions as in Fortinet’s internal lab tests. In no event does Fortinet make any commitment related to future deliverables, features or development, and circumstances may change such that any forward-looking statements herein are not accurate. Fortinet disclaims in full any covenants, representations, and guarantees pursuant hereto, whether express or implied. Fortinet reserves the right to change, modify, transfer, or otherwise revise this publication without notice, and the most current version of the publication shall be applicable.

For Product License Agreement / EULA and Warranty Terms, visit https://www.fortinet.com/content/dam/fortinet/assets/legal/EULA.pdf
FGR-70G-5G-DUAL-QSG-20240122

FORTINET logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals