ELKAY VRCSM1311_1A Bottle Filler Retrofit Installation Guide

July 27, 2024
ELKAY

ELKAY VRCSM1311_1A Bottle Filler Retrofit

ELKAY VRCSM1311_1A Bottle Filler Retrofit

IMPORTANT

THIS IS AN INDOOR APPLICATION ONLY. ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON.

TOOLS REQUIRED

GLOVES
SAFETY GLASSES
5/16 NUT DRIVER (HIGHLY RECOMMENDED)
5/32” ALLEN WRENCH
FLAT HEAD SCREWDRIVER
LEVEL
PENCIL

IMPORTANT! INSTALLER PLEASE NOTE.

INSTALLER

To insure you install this Kit easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES

WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov

Product Description

Product Description Product
Description

Installation Procedure of Bottle Filler w/o Back Panel Assembly

  1. Turn off water supply and dispense water to relieve pressure of the fountain.

  2. Remove the two (2) mounting screws securing the top cover to the bottle filler with 5/32” Allen wrench. Remove the top cover.
    Note: Do not discard mounting screws, they willbe needed to reinstall the top cover.
    Installation Procedure

  3. Remove the wall mounting plate.
    Installation Procedure

  4. Loosen but do not remove two (2) mounting screws one on each side of the bottle filler and slide upwards to remove the bottle filler from drain tray assembly.
    Installation Procedure

  5. Place mounting plate and drain tray against wall on top of the fountain. Center the mounting plate and drain tray with the fountain. Mark the four (4) mounting holes and waterline hole with a pencil. Drill four (4) mounting holes and a 2” hole for waterline in the wall as per the markings.
    Installation Procedure

  6. Install the wall mounting plate and drain tray to the wall using four (4) 9/32” bolts (not supplied) through the mounting holes. Use appropriate fasteners for your wall type.
    Note: To prevent scratching the fountain, place a towel or soft cloth over the fountain.
    Installation Procedure

  7. Before reinstalling the bottle filler, install the provided poly lock clips. Refer to Figure:
    VRCSM1311, VRCSMM1311 plumbing for poly lock clip locations. Reinstall the bottle filler by aligning the slots to two (2) mounting screws one on each side of the bottle filler and slide down. Tighten the screws to secure the bottle filler.
    Symbol Do not over tighten screws.
    Installation Procedure
    Note: Make sure to route water line through the hole on the mounting plate before securing the bottle filler.

  8. Reinstall the top cover on the bottle filler using two (2) mounting screws.
    Installation Procedure

  9. Remove the two (2) mounting screws securing the bottom panel of the fountain. Remove bottom panel from the fountain basin.
    Note: Do not discard mounting screws, they will be needed to reinstall the top cover.
    Installation Procedure

  10. To connect the water supply and start the unit, follow the instructions in Section 2, from Step 11 to Step 17.

Installation Procedure of Bottle Filler with Back Panel Assembly

  1. To remove wall mounting plate and drain tray from the bottle filler, follow the instructions in Section 1 from Step 1 to Step 4.

  2. Unpack Back panel assembly from the box, peel off any protective wrap.

  3. Place the wall mounting plate and drain tray on the back panel. Align the holes as shown below and install using four (4) supplied screws.
    Installation Procedure

  4. Before reinstalling the bottle filler, install the provided poly lock clips. Refer to Figure:
    VRCSM1311, VRCSMM1311 plumbing for poly lock clip locations. Reinstall the bottle filler by aligning the slots to two (2) mounting screws one on each side of the bottle filler and slide down. Tighten the screws to secure the bottle filler.
    Symbol  Do not over tighten screws
    Installation Procedure
    Note: Make sure the water line is feed through hole on the bottle filler back panel before securing the bottle filler.

  5. Reinstall the top cover on the bottle filler using two (2) mounting screws
    Installation Procedure

  6. Loosen do not remove the mounting bolts of the fountain. Pull the fountain 1” away from the wall.
    Installation Procedure

  7. Remove P-trap from fountain drain. Remove water supply line from fountain to installing the Bottle filler.
    Note: Have container/bucket readily available to catch water from lines.
    Installation Procedure

  8. Install the bottle filler. Align the slots of back panel to mounting bolt of fountain and slide down the bottle filler. Push the fountain toward the back panel. Secure the fountain and bottle filler by tighten the mounting bolts.
    Symbol Do not over tighten screws.
    Installation Procedure

  9. Reinstall the P-trap to the fountain drain.

  10. Install 3/8” tee (not supplied) on the screwdriver stop valve of the fountain. Connect one end of tee to the fountain bubbler.

  11. Route the 3/8” water line of the bottle filler to one end of tee installed to the screwdriver stop of the fountain.

  12. Make final water supply connections.

  13. Turn water supply on and inspect for leaks. Fix all leaks before continuing.

  14. Verify proper dispensing from the bottle filler by placing a cup under the water dispenser spout and press the button on the front panel.
    Note: The first initial dispenses might have air in the line which may cause a sputter. This will be eliminated once all air is purged from the line. A steady stream of water assures all air is removed.

  15. Check stream height from the bubbler. Adjust valve for desired flow height. For additional details refer Haws 5874 series valve manual (not supplied) available on Haws website.
    Installation Procedure

  16. Reinstall the bottom panel of the fountain basin using two (2) mounting screws.

OPERATION OF QUICK CONNECT FITTINGS

  • SIMPLY PUSH IN TUBE TO ATTACH

  • TUBE IS SECURED IN POSITION

  • PUSH IN COLLET TO RELEASE TUBE

PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE

PARTS LIST

PARTS LIST

ITEM NO.| PART NO.| DESCRIPTION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28| 0000000178
10031C
100322740560
110041643890
110077043890
15007C
15040C
2000001099 2000001101 2000001103 2000001104 2000001105 2000001107
2000001110
45960C
28308C
40045C
45663C
45736C
50985C
56305C
56332C
61313C
75672C
75729C
75744C P05031 2000001102| “O”- Ring – 1.35” I.D. X 1.43” O.D.
1-1/8-24 Retaining Nut Gasket-Black 0.68 X 1.03 Nut-Hex
Washer-Plain Nipple-Bubbler (GF) Nozzle Assembly Back Plate VR BF
Filler Panel VR BF – Powder Coat Drain Tray – Powder Coat
Top Cover – Powder Coat
VR-BF Tower Assy – Powder Coat Tower Wrapper Mounting
Tower Lower Mtg. Assembly Button – Push W/Out Hole Washer-Spacer 2.00 O.D. Nut-Hex 1-5/16”
Sleeve – Push Button Guide Nut-Reg.
Mount
Holder-Regulator Gasket-VR Bubbler Snap Bushing 1-3/8 Regulator W/Spring Screw – Cap #6-32
1/4-20 X 0.75 Socket Button Head Screw
1/4-20 Cal Style Rivet Nut Full Flow Hidden Aerator
Back Panel Assy – Powder Coat

Figure: VRCSMM1311 Assembly

Parts List

Figure: VRCSM1311, VRCSMM1311 Plumbing
Note: Locking clips (item 29 and 30) are provided with unit, but not installed. Installer is responsible for assembly of locking clips.

PARTS LIST

ITEM NO.| PART NO.| DESCRIPTION
29
30
31
32
33| 2000001122
2000001123
55994C
56307C
70745C| 3/8” Red Locking Clip 1/4” Red Locking Clip Tube-Poly 1/4x.040 Wall Tube-Poly 3/8x.062 Wall 3/8 X 1/4 Union